CAUTION – RISK OF SHOCK – Disconnect Power at the main
circuit breaker panel or main fuse box before starting and during
the installation.
1) Pass fixture electrical wire and ground wire through desired
amount of stems D & E and screw together using supplied
threaded nipples into coupler on top of fixture. NOTE: one
(1) 12 inch stem minimum is required during mounting for
safety.
2) Screw in two (2) canopy mounting screws into the mounting
strap and connect mounting strap to outlet box.
3) Connect the two (2) loops, chain link with two (2) threaded
nipples to the canopy using the lockwasher and hexnut
supplied.
4) Route wires and ground wire through chain link and through
canopy into the electrical box. Connect the D & E stems to
the lower loop.
5) Grounding instructions: (See Illus. A or B).
A) On fixtures where mounting strap is provided with a hole
and two raised dimples. Wrap ground wire from outlet
box around green ground screw, and thread into hole.
B) On fixtures where a cupped washer is provided. Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
If fixture is provided with ground wire. Connect fixture
ground wire to outlet box ground wire with wire connector
(not provided.) after following the above steps. Never
connect ground wire to black or white power supply wires.
CANOPY
OUTLET BOX
COUVERCLE
LOOP / BOUCLE
CHAIN LINK / MAILLON DE CHAÎNE
LOOP / BOUCLE
NIPPLE / RACCORD FILETÉ
WIRE CONNECTORS / CONNECTEURS DE FIL
STRAP MOUNTING SCREWS / VIS DE L'ÉTRIER DE MONTAGE
MOUNTING STRAP / ÉTRIER DE MONTAGE
MOUNTING SCREWS / VIS DE MONTAGE
HEXNU T / ÉCROU HEXAGONAL
LOCKWASHER / RONDELLE DE BLOCAGE
(2) LOCKWASHER / RONDELLE DE BLOCAGE
(2) LOCK-UP KNOBS / BOULES DE BLOCAGE
E
A
OUTLET BOX
GROUND
GREEN GROUND
SCREW
WIRE CONNECTOR
FIXTURE
GROUND
DIMPLES
OUTLET BOX
GROUND
GREEN GROUND
SCREW
B
FIXTURE
GROUND
CUPPED
WASHER
6) Make wire connections (connectors not provided).
Reference chart below for correct connections and wire
accordingly.
Connect Black or
Red Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Insulated wire (other than green)
with copper conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Insulated wire (other than green)
Connect
White Supply Wire to:
Clear, Brown, Gold or Black
with tracer
with silver conductor
Neutral Wire
7) Use the (2) two ball knobs and two (2) lockwashers to secure
canopy after wire connections are completed per below.
8) Install approved bulb, item C, not supplied.
**MINIMUM OF ONE 12" STEM
REQUIRED FOR MOUNTING.** /
**UN MINIMUM D'UNE TIGE DE 12"
NÉCESSAIRE POUR LE MONTAGE.**
D
E
C
BULB NOT
INCLUDED /
AMPOULE
INSTRUCTIONS
For Assembling and Installing Fixtures in Canada Pour
L’assemblage et L’installation Au Canada
1) Passer le fil électrique du luminaire et le fil de terre par le
nombre de tiges D et E et les visser ensemble à l’aide des
raccords filetés (fournis) dans l’accouplement en haut du
luminaire. REMARQUE : une (1) tige de 30 cm minimum est
requise pendant le montage pour la sécurité.
2) Visser deux (2) vis de montage du couvercle dans l’étrier de
montage et raccorder l’étrier de montage à la boîte à prises.
3) Connecter les deux (2) boucles, le maillon de chaîne avec
deux (2) raccords filetés au couvercle en utilisant la rondelle
de blocage et l’écrou hexagonal fournis.
4) Acheminer les fils et le fil de terre par le maillon de la chaîne
puis le couvercle dans le boîtier électrique. Connecter les
tiges D et E à la boucle inférieure.
5) Établir les connexions de fil conformément aux instructions
ci-dessous.
Connecter le fil noir ou
rouge de la boite
A Noir A Blanc
*Au cordon parallèle (rond et lisse)
Au bransparent, doré, marron, ou
noir sans fil distinctif
Fil isolé (sauf fil vert) avec
conducteur en cuivre
*Remarque: Avec emploi d’un fil paralléle
(SPT I et SPT II). Le fil neutre est á angles
droits ou strié et l’autre fil doit étre rond ou
lisse (Voir le schéma).
Connecter le fil blanc de la boîte
*Au cordon parallele (à angles droits el strié)
Au transparent, doré, marron, ou
noir avec un til distinctif
Fil isolé (sauf fil vert) avec
conducteur en argent
Fil Neutre
6) Utiliser les deux (2) boules à billes et les deux (2) rondelles
de blocage pour fixer le couvercle après avoir établir les
connexions de fils conformément aux instructions ci-des
sous.
7) Installer l’ampoule approuvée, élément C (non fourni).