Attention: Your product is
marked with this symbol. It
means that used electrical
and electronic products
should not be mixed with
general household waste.
There is a separate
collection system for these
products.
A. Information on Disposal for Users (private households)
1. In the European Union
Attention: If you want to dispose of this equipment, please do not use the ordinary dust
bin!
Used electrical and electronic equipment must be treated separately and in
accordance with legislation that requires proper treatment, recovery and recycling of
used electrical and electronic equipment.
Following the implementation by member states, private households within the EU
states may return their used electrical and electronic equipment to designated
collection facilities free of charge*. In some countries* your local retailer may also
take back your old product free of charge if you purchase a similar new one.
*) Please contact your local authority for further details.
If your used electrical or electronic equipment has batteries or accumulators, please
dispose of these separately beforehand according to local requirem ents .
By disposing of this product correctly you will help ensure that the waste undergoes
the necessary treatment, recovery and recycling and thus prevent potential negative
effects on the environment and human health which could otherwise arise due to
inappropriate waste handling.
2. In other Countries outside the EU
If you wish to discard this product, please contact your local authorities and ask for the
correct method of disposal.
For Switzerland: Used electrical or electronic equipm ent can be returned free of
charge to the dealer, even if you don’t purchase a new product. Further collection
facilities are listed on the homepage of
www.swico.chor www.sens.ch.
. Information on Disposal for Business Users.
B
1. In the European Union
If the product is used for business purposes and you want to discard it:
Please contact your SHARP dealer who will inform you about the take-back of the
product. You might be charged for the costs arising from take-back and recycling.
Small products (and small amounts) might be taken back by your local collection
facilities.
For Spain: Please contact the established collection system or your local authority for
take-back of your used products.
2. In other Countries outside the EU
If you wish to discard of this product, please contact your local authorities and ask for
the correct method of disposal.
CONTENTS
• IMPORTANT SAFETY INSTRUCTIONS..E-1
• PART NAMES...........................................E-3
Do not pull or deform the power supply cord. Pulling and misuse of the power supply cord
1
can result in damage to the unit and cause electrical shock.
E-19
Be careful not to expose your body directly to the outlet air for a long time. It may affect
2
your physical conditions.
When using the air conditioner for infants, children, elderly, bedridden, or disabled people
3
make sure the room temperature is suitable for those in the room.
Never insert objects into the unit. Inserting objects can result in injury due to the high
4
speed rotation of internal fans.
Ground the air conditioner without fail. Do not connect the grounding wire to gas pipe,
5
water pipe, lightning rod or telephone grounding wire. Incomplete grounding may cause
electric shock.
If anything is abnormal with the air conditioner (ex. a burning smell), stop the operation
6
immediately and turn the circuit breaker OFF.
The appliance shall be installed in accordance with national wiring regulations.Improper
7
cable connection can cause the power supply cord, plug and the electrical outlet to
overheat and cause fire.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent
8
or a similarly qualified person in order to avoid a hazard. Use only the manufacturespecified power cord for replacement.
WARNINGS FOR INSTALLATION / REMOVAL / REPAIR
• Do not attempt to install/remove/repair the unit by yourself. Incorrect work will cause electric
shock, water leak, fire etc. Consult your dealer or other qualified service personnel for the
installation/removal/repair of the unit.
This equipment complies with the requirements of Directives 89/336/EEC and 73/23/
EEC as amended by 93/68/EEC.
E-1
IMPORTANT SAFETY INSTRUCTIONS
CAUTIONS FOR USE
Open a window or door periodically to ventilate the room, especially when using gas
1
appliances. Insufficient ventilation may cause oxygen shortage.
Do not operate the buttons with wet hand. It may cause electric shock.
2
For safety, turn the circuit breaker off when not using the unit for an extended period of
3
time.
Check the outdoor unit mounting rack periodically for wear and to make sure it is firmly
4
in place.
Do not put anything on the outdoor unit nor step on it. The object or the person may fall
5
down or drop, causing injury.
This unit is designed for residential use. Do not use for other applications such as in a
6
kennel or greenhouse to raise animals or grow plants.
Do not place a vessel with water on the unit. If water penetrates into the unit, electrical
7
insulations may deteriorate and cause electric shock.
Do not block the air inlets nor outlets of the unit. It may cause insufficient performance
8
or troubles.
Be sure to stop the operation and turn the circuit breaker off before performing any
9
maintenance or cleaning. A fan is rotating inside the unit and you may get injured.
10
11
Do not splash or pour water directly on the unit. Water can cause electrical shock or
equipment damage.
This appliance is not intended for use by young children or infirm persons without
supervision.
Young children should be supervised to ensure that they do not play with the appliance.
CAUTIONS FOR LOCATION / INSTALLATION
• Make sure to connect the air conditioner to power supply of the rated voltage and
frequency.
Use of a power supply with improper voltage and frequency can result in equipment
damage and possible fire.
• Do not install the unit in a place where inflammable gas may leak. It may cause fire.
Install the unit in a place with minimal dust, fumes and moisture in the air.
• Arrange the drain hose to ensure smooth drainage. Insufficient drainage may cause wetting
of the room, furniture etc.
• Make sure a leak breaker or a circuit breaker is installed, depending on the installation
location, to avoid electrical shock.
E-2
PART NAMES
INDOOR UNIT
1
1 Inlet (Air)
2
3
4
5
6
7
8
9
0
q
w
e
2 PLASMACLUSTER Lamp
(blue)
3 DEODORANT DUST COL-
LECTION FILTER
(non-washable)
4 Open Panel
5 Air Filters
6 AUX. Button
7 Indicator
8 Power Supply Cord
9 Vertical Adjustment Louvres
0 Horizontal Adjustment
Louvres
q Outlet (Air)
w RECEIVER Window
e Remote Control
(Open Panel Closed)
OUTDOOR UNIT
r
t
y
u
i
o
p
a
r OUTDOOR Temp. Lamp
(green )
t ROOM Temp. Lamp
(green )
y TEMPERATURE INDICATOR
u TIMER Lamp (orange )
i OPERATION Lamp (red )
o Inlet (Air)
p Refrigerant Tube and
Interconnecting Cord
a Drainage Hose
s Outlet (Air)
NOTE: Actual units might vary slightly from those shown above.
s
E-3
PART NAMES
REMOTE CONTROL
DISPLAY
MODE
FAN
SWING
1h
CLEAN
SET/C
1
2
3
4
5
6
7
8
9
0
q
w
e
r
t
y
u
i
o
p
a
1 TRANSMITTER
2 DISPLAY (Liquid Crystal Display)
3 PLASMACLUSTER Button
4 DISPLAY Button
5 ON/OFF Button
6 THERMO. (Thermostat) Button
7 FULL POWER Button
8 PROGRESSIVE AIRFLOW Button
9 MODE Button
0 TIMER ON Button (for setting the timer)
q TIMER OFF Button (for setting the timer)
w ONE-HOUR OFF TIMER Button
e TIME ADVANCE Button
r TIME REVERSE Button
t SELF CLEAN Button
y TIMER SET/CANCEL Button
u Indicates BATTERY COMPARTMENT is
below this mark
i 10°C Button
o CLOCK Button
p FAN Button
a SWING Button
L.C.D. REMOTE CONTROL DISPLAY
s PROGRESSIVE AIRFLOW SYMBOL
d SELF CLEAN SYMBOL
f PLASMACLUSTER SYMBOL
g MODE SYMBOLS
: AUTO: DRY
: HEAT: COOL
h THERMOSTAT SETTING FOR AUTO AND
DRY MODES
j TEMPERATURE INDICATOR
k TRANSMITTING SYMBOL
l FULL POWER SYMBOL
; FAN SPEED SYMBOLS
: AUTO: LOW
: HIGH: SOFT
E-4
s
d
f
g
31
TIMER ON INDICATOR/CLOCK
Indicates the on timer preset time or current
time.
32
TIMER OFF INDICATOR
Indicates the preset time for off timer or onehour off timer.
h
j
k
l
;
31
32
SETTING DEODORANT DUST COLLECTION FILTER
The deodorant dust collection filters are packed as accessory of this unit. During
operation of the air conditioner, the filters remove dust and tobacco smoke from the
air and discharges clean air.
Take out the air filters.
1
1 Open the open panel.
2 Push the air filters up slightly to
unlock them.
1
2
3
Filter stopper
3 Pull the air filters down to remove
them.
Set the deodorant dust collection filter
2
under the filter stoppers located on
the air filter.
Deodorant dust
collection filter
Air filter
3
2
1
Reinstall the air filters
3
1 Reinstall the air filters in the origi-
nal positions.
2 Close the open panel.
3 Push the arrow-marked of the
panel firmly to lock it in place.
Precautions
• The filters are sealed in a plastic bag to keep their dust collection effect.
Do not open the bag until using the filters. (Otherwise the filters life may get shorter.)
• Do not expose the filters to direct sunlight. (Otherwise they may deteriorate.)
E-5
USING THE REMOTE CONTROL
LOADING BATTERIES Use two size-AAA (R03) batteries.
Remove the remote control
1
cover.
Insert batteries in the compart-
2
ment, making sure the ± and
— polarities are correctly
aligned.
• The display indicates "AM
6:00" when batteries are properly installed.
Remote control
cover
Reinstall the cover.
3
-
+
+
-
NOTES:
• The battery life is approximately one year in normal use.
• When you replace the batteries, always change both batteries, and make sure
they are the same type.
• If the remote control does not operate properly after replacing the batteries, take
out the batteries and reinstall them again after 30 seconds.
• If you will not be using the unit for a long time, remove the batteries from the
remote control.
HOW TO USE THE REMOTE CONTROL
Point the remote control towards
the unit’s signal receiver window
and press the desired button. The
unit generates a beep when it receives the signal.
• Make sure there is no curtain or other
object between the remote control and the
unit.
• The remote control can send signals from
up to 7 metres away.
E-6
CAUTION
• Do not allow the signal receiver window to receive strong direct sunlight, since it can
adversely affect its operation. If the signal receiver window is exposed to direct sunlight,
close a curtain to block the light.
• Using a fluorescent lamp with a quick starter in the same room may interfere with
transmission of the signal.
• The unit can be affected by signals transmitted from the remote control of a television,
VCR or other equipment used in the same room.
• Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit
and remote control from moisture and shock which can discolour or damage them.
SET CURRENT CLOCK TIME
There are two clock modes:
12-hour mode and 24-hour
mode.
MODE
FAN
SWING
1h
CLEAN
SET/C
2
3
Example: 5 o'clock in the afternoon
ClockDisplay
12-hour modePM 5:00
24-hour mode17:00
1
2
1
3
To set to the 12-hour mode, press the
CLOCK button once in the first step.
To set to the 24-hour mode, press the
CLOCK button twice in the first step.
Press the TIME ADVANCE or REVERSE
button to set the current time.
• Keep the button pressed to advance or
reverse the time display quickly.
Press the SET/C button.
• The colon (:) blinks to indicate that the
clock is functioning.
NOTE:
• The current time cannot be set when the
timer is operating.
E-7
BASIC OPERATION
1
Press the MODE button to select the operation mode.
AUTOHEATCOOLDRY
DISPLAY
MODE
FAN
SWING
1h
CLEAN
SET/C
2
5
3
1
4
2
3
4
Press the ON/OFF button to start operation.
• The red OPERATION lamp ( ) on the unit
will light.
Press the THERMO. button to set the desired temperature.
• In the AUTO and
DRY mode, the temperature can be
changed in 1°C increments within the
range of 2°C higher
to 2°C lower from the
temperature automatically determined
by the air conditioner.
• In the COOL and
HEAT modes, the
temperature can be
set within the range
of 18 to 32°C
(Example: 1°C higher)
C
(Example: 2°C lower)
C
Press the FAN button to set the desired fan
speed.
AUTOSOFTLOWHIGH
TIPS ABOUT AUTO MODE
In the AUTO mode, the temperature setting and mode are automatically selected according to
the room temperature and outdoor temperature when the unit is turned on.
Modes and Temperature Settings
During operation, if the outdoor temperature
changes, the temperature settings will automatically slide as shown in the chart.
5
• In the DRY mode, the fan speed is preset to
AUTO and cannot be changed.
To turn off the unit, press the ON/OFF button again.
• The red OPERATION lamp ( ) on the unit
will turn off.
the figures in ( ) are temperature settings
E-8
TIPS ABOUT INDICATOR PANEL
The indicator panel will change each time you press
the DISPLAY button in the following manner.
The room temperature is displayed.
temperature
Indiactor
temperature
Indiactor
NOTES:
• The displayed temperatures are rough estimates and may vary from the actual temperatures.
• Temperature display ranges
Room temperature: 0°C ~ 40°C ( is displayed when less than 0°C and when higher
than 40°C)
Outdoor temperature: -9°C ~ 45°C ( is displayed when less than -9°C and when higher
than 45°C)
•
is displayed during the first 60 seconds of operation while the temperatures are being
detected.
• Only the room temperature can be displayed for 5 seconds when the unit is not in operation.
• During SELF CLEAN operation, the indicator panel will display remaining time of the
operation. Room and outdoor temperature will not be displayed even if you press the
DISPLAY button.
Room Temp.
Lamp
Outdoor Temp.
Lamp
The outdoor
temperature is
displayed.
No display.
DISPLAY
PROGRESSIVE AIRFLOW
Press the PROGRESSIVE AIRFLOW button during cooling or dry operation when you do
not want to feel cold air.
Vertical adjustment louvre is set obliquely upward to deliver cool air to the ceiling.
Press the button during heating operation.
Vertical adjustment louver is set downward to deliver the warm air down to the floor and
warm you.
During operation, press the PROGRESSIVE
1
AIRFLOW button.
• The remote control will display .
AM
DISPLAY
1
TO CANCEL
Press the PROGRESSIVE AIRFLOW button.
NOTES:
• The Progressive Airflow setting is cancelled when you
press FULL POWER button while Progressive Airflow is
set.
• If you want Progressive Airflow operation in Full Power
mode, press PROGRESSIVE AIRFLOW button during
Full Power operation.
E-9
ADJUSTING THE AIR FLOW DIRECTION
VERTICAL AIR FLOW DIRECTION
The air flow direction is automatically preset in each mode as follows for optimum
comfort:
COOL and DRY modes Horizontal air flow
HEAT
mode Diagonal air flow
HOW TO ADJUST THE AIR FLOW DIRECTION
Press the SWING button on the
remote control once.
• The vertical adjustment louvre
will change its angle continuously.
COOL and DRY modes
Press the SWING button again
when the vertical adjustment
louvre is at the desired position.
• The louvre will stop moving within
the range shown in the diagram.
• The adjusted position will be
memorized and will be automatically set to the same position
when operated the next time.
Adjustment range
HEAT mode
HORIZONTAL AIR FLOW DIRECTION
Hold the horizontal adjustment
louvre as shown in the diagram
and adjust the air flow direction.
CAUTION
Never attempt to adjust the vertical adjustment louvres manually.
• Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction
when the remote control is used for adjustment.
• When the vertical adjustment louvre is positioned at the lowest position in the COOL or
DRY mode for an extended period of time, condensation may result.
Do not adjust the horizontal adjustment louvre to the extreme left or right in the COOL mode
with the fan speed set to "SOFT(
Condensation may form on the louvres.
)" for an extended period of time.
E-10
10°C OPERATION
Heating operation with 10°C set temperature will be performed.
Press the MODE button and select HEAT mode.
1
Press the ON/OFF button to start HEAT operation.
2
AM
Press the 10°C button.
3
• The remote control will display 10°C .
TO CANCEL
DISPLAY
MODE
FAN
SWING
1h
CLEAN
1
SET/C
Press the 10°C button again.
• 10°C operation will also be cancelled when the
operation mode is changed, or when the unit is
turned off.
NOTE:
• 10°C operation will not be available with heating
operation automatically selected by AUTO mode.
FULL POWER OPERATION
In this operation, the air conditioner works at maximum power to make the room cool
or warm so rapidly that you can use it just after you come home.
AM
DISPLAY
1
To activate the FULL POWER operation, press the
1
FULL POWER button during operation.
• The remote control will display .
• The temperature display will go off.
TO CANCEL
Press the FULL POWER button again.
• FULL POWER operation will also be cancelled when
the operation mode is changed, or when the unit is
turned off.
NOTE:
• You can not set the temperature or fan speed during
the FULL POWER operation.
E-11
ONE-HOUR OFF TIMER
When the ONE-HOUR OFF TIMER is set, the unit will automatically turn off after one
hour.
Press the ONE-HOUR OFF TIMER button.
1
• The remote control displays “ ”.
• The orange TIMER lamp ( ) on the unit will light up.
• The unit will stop operating after one hour.
TO CANCEL
Press the TIMER CANCEL (SET/C) button.
MODE
FAN
1h
CLEAN
1
NOTES:
• The ONE-HOUR OFF TIMER operation has priority over TIMER ON and TIMER OFF
operations.
• If the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit will operate
for an hour at the formerly set condition.
• If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER is
activated, press the ONE-HOUR OFF TIMER button again during operation.
• If TIMER ON and/or TIMER OFF are set, TIMER CANCEL button cancels every setting.
• The orange TIMER lamp ( ) on the unit will turn off.
Alternatively, turn the unit off by pressing the ON/
OFF button.
• The red OPERATION lamp ( ) and the orange
TIMER lamp ( ) on the unit will turn off.
E-12
PLASMACLUSTER OPERATION
The Plasmacluster Ion generator inside the air conditioner will release positive and
negative plasmacluster ions into the room.
Approximately the same numbers of positive and negative ions released into the air will
reduce some airborn mold.
During operation, press the PLASMACLUSTER button.
1
• The remote control will display “ ”
• The blue PLASMACLUSTER lamp on the unit will light up.
TO CANCEL
Press the PLASMACLUSTER button again.
• The PLASMACLUSTER lamp on the unit will turn off.
1
DISPLAY
NOTES:
• Use of the PLASMACLUSTER operation will be memorized, and it will be activated the next
time you turn on the air conditioner.
• To turn off the PLASMACLUSTER lamp, press the DISPLAY button.
• When the PLASMACLUSTER button is pressed while the unit is not operating, the
PLASMACLUSTER operation will be performed without accompanying air conditioning mode
(eg, HEATING or COOLING).
The mode symbol of the remote control will go off and the fan speed can not be set AUTO.
SELF CLEAN OPERATION
SELF CLEAN operation will provide effect to reduce the growth mold fungus with
Plasmacluster ions, and to dry inside of the air conditioner unit. This operation is
accompanied by FAN or HEAT mode. Utilize the operation at seasonal change over
terms. Mold fungus already grown can not be eliminated by this operation.
Press the SELF CLEAN button when the unit is not
1
operating.
• The remote control displays " ".
• The blue PLASMACLUSTER lamp on the unit will light up.
• The unit will stop operation after forty minutes.
• The remaining operation time will be indicated on the
TEMPERATURE INDICATOR of the indoor unit in minute
decrements.
TO CANCEL
MODE
FAN
NOTE:
• You cannot set the temperature, fan speed, air flow direction or timer setting during the SELF
CLEAN operation.
1h
CLEAN
Press the SELF CLEAN button.
1
Alternatively, turn the unit off by pressing the ON/OFF
button.
• The blue PLASMACLUSTER lamp on the unit will turn off.
E-13
TIMER OPERATION
NOTE:
Before setting the timer, make sure the clock is properly set with the current time.
TIMER OFF
Press the TIMER OFF ( ) button.
1
The TIMER OFF indicator will blink; press the
2
TIME ADVANCE or REVERSE buttons to set
the desired time. (The time can be set in 10minute increments.)
Point the remote control at the signal receiver
3
window on the unit and press the TIMER SET
(SET/C) button.
DISPLAY
MODE
1h
• The orange TIMER lamp ( ) on the unit will
light.
• The unit will generate a beep when it receives the
signal.
CLEAN
FAN
SWING
SET/C
TIPS ABOUT TIMER OFF OPERATION
1
2
3
When the TIMER OFF mode is set, the
temperature setting is automatically
adjusted to prevent the room from
becoming excessively hot or too cold
while you sleep. (Auto Sleep function)
COOL/DRY MODE:
• One hour after the time operation begins,
the temperature setting rises 1°C higher
than the original temperature setting.
HEAT MODE:
• One hour after the timer operation begins,
the temperature setting drops 3°C lower
than the original temperature setting.
TO CANCEL TIMER MODE
Press the TIMER CANCEL (SET/C) button.
• The orange TIMER lamp ( ) on the unit will
turn off.
• The current clock
time will be displayed on the remote control.
MODE
FAN
SWING
1h
CLEAN
SET/C
NOTE:
• If any TIMER ON, TIMER OFF and ONE-HOUR
OFF TIMER are set, the TIMER CANCEL button cancels all settings.
TO CHANGE TIME SETTING
Cancel the TIMER setting first, then set it
again.
E-14
TIMER ON
DISPLAY
MODE
FAN
SWING
1h
CLEAN
SET/C
1
2
3
Press the TIMER ON ( ) button.
1
The TIMER ON indicator will blink; press the
2
TIME ADVANCE or REVERSE buttons to set
the desired time. (The time can be set in 10minute increments.)
Point the remote control at the signal receiver
3
window on the unit and press the TIMER SET
(SET/C) button.
• The orange TIMER lamp ( ) on the unit will light.
• The unit will generate a beep when it receives the
signal.
Select the operation condition.
4
• The unit will turn on prior to the set time to allow
the room to reach the desired temperature by the
programmed time. (Awaking function)
COMBINED USE OF ON AND OFF TIMERS
You can use the ON and OFF timers in combination.
Example:
To stop operation at 11:00 p.m. and resume operation (With the same mode and temperature settings)
to bring the room temperature to the desired level
by 7:00 a.m.
Set the TIMER OFF to 11:00 p.m. during opera-
1
tion.
Set the TIMER ON to 7:00 a.m.
2
The arrow (
indicator and the TIMER OFF indicator shows which
timer will activate first.
or ) between the TIMER ON
NOTES:
• You cannot programmed the ON-TIMER and OFF-TIMER to operate the unit at different
temperatures or other settings.
• Either timer can be programmed to activate prior the other.
E-15
AUXILIARY MODE
Use this mode when the remote control is not available.
TO TURN ON
Lift the front panel of the indoor unit and press the AUX.
button on the operation panel.
• The red OPERATION lamp ( ) on the unit will light and the
unit will start operating in the AUTO mode.
• The fan speed and temperature setting are set to AUTO.
TO TURN OFF
Press the AUX. button on the operation panel again.
• The red OPERATION lamp ( ) on the unit will turn off.
NOTE:
If the AUX. button is pressed during normal operation, the unit will turn off.
MAINTENANCE
Be sure to disconnect the power cord from the wall outlet or turn off the circuit
breaker before performing any maintenance.
CLEANING THE FILTERS
1
2
3
3
The air filters should be cleaned every two weeks.
TURN OFF THE UNIT
1
REMOVE THE FILTERS
2
1 Lift the open panel.
2 Push the air filters up slightly to unlock them.
3 Pull the air filters down to remove them.
TAKE OFF THE DEODORANT DUST
3
COLLECTION FILTERS FROM THE AIR
FILTERS
CLEAN THE FILTERS
4
Use a vacuum cleaner to remove dust. If the
filters are dirty, wash them with warm water
and a mild detergent. Dry filters in the shade
before reinstalling.
REINSTALL THE DEODORANT DUST
5
COLLECTION FILTERS
2
1
REINSTALL THE FILTERS
6
1 Reinstall the filters in the original positions.
2 Close the front panel.
3 Push the arrow-marked of the panel firmly
to lock it in place.
E-16
MAINTENANCE
CLEANING THE UNIT AND THE REMOTE CONTROL
• Wipe them with a soft cloth.
• Do not directly splash or pour water on them. We can cause electrical shock or
equipment damage.
• Do not use hot water, thinner, abrasive powders or strong solvents.
MAINTENANCE AFTER AIR
CONDITIONER SEASON
Operate the unit in the SELF
1
CLEAN OPERATION to allow the
mechanism to thoroughly dry.
Stop the operation and unplug the
2
unit. Turn off the circuit breaker, if
you have one exclusively for the
air conditioner.
Clean the filters, then reinstall
3
them.
MAINTENANCE BEFORE
AIR CONDITIONER SEASON
Make sure that the air filters are
1
not dirty.
Make sure that nothing obstructs
2
the air inlet or outlet.
Check the outdoor mounting rack
3
periodically for wear and to make
sure it is firmly in place.
CHANGING THE DEODORANT DUST COLLECTION FILTER
The filter should be changed every 3~6 months
REMOVE THE AIR FILTER
1
Filter stopper
NOTE:
• The dirty deodorant dust collection filter is not washable for reuse.
The new filter is available at your nearest dealer.
Replacement filter: Type AZ-F900DN
Disposal of Filters
Please dispose of replaced filters according to the local disposal laws and regulations.
DEODORANT DUST COLLECTION Filter materials:
• Filter: Polypropylene
• Frame: Polyester
CHANGE THE DEODORANT DUST
2
COLLECTION FILTER
1 Take off the old deodorant dust collection
filter from the air filter.
2 Set the new deodorant dust collection fil-
ter, under the filter stoppers located on the
air filter.
REINSTALL THE AIR FILTER
3
E-17
MAINTENANCE
CLEANING THE INTERIOR OF AIR CONDITIONER UNIT
Be sure to disconnect the power
1
cord from the wall outlet or turn
off the circuit breaker.
REMOVE THE VERTICAL
2
ADJUSTMENT LOUVRE
1 Pull the left cover open.
2 Open the lower louver slightly
and rotate the upper louvre until it stops.
3 Hold the left side of the lower
louvre and pull it frontward.
Remove it to the lower left direction.
NOTE:
Only the lower louvre can be removed.
Left Cover
Vertical Adjustment Louvre
(Upper side)
Vertical Adjustment Louvre
(Lower side)
1
2
2
1
Shaft Receiver
3
CLEAN THE INTERIOR OF THE
3
AIR CONDITIONER UNIT
make sure the fan inside is not
rotating.
Remove the dust using a vacuum
cleaner or wipe with dry cloth.
REINSTALL THE VERTICAL
4
ADJUSTMENT LOUVRE
1 Insert the shaft at the right of
the louvre into the hole of the
unit.
2 Put the shaft at the left of the
louvre in the shaft receiver of
the unit.
Make sure the shaft at the center of the louvre is placed in the
center shaft receiver of the air
outlet.
3 Close the left cover until it
clicks.
2
Shaft
Shaft
Hole
1
Shaft Receiver
2
Connect the power cord to the
5
wall outlet or turn on the circuit
breaker.
3
Cover
E-18
ADDITIONAL NOTES ON OPERATION
OPERATING TEMPERATURE RANGE
INDOOR TEMP. OUTDOOR TEMP.
upper limit
COOLING
lower limit
HEATING
D.B. = Dry-bulb W.B. = Wet-bulb
upper limit
lower limit
32˚C D.B.43˚C D.B.
23˚C W.B. -
21˚C D.B.21˚C D.B.
15˚C W.B. -
27˚C D.B.24˚C D.B.
-18˚C W.B.
20˚C D.B.-8.5˚C D.B.
--9.5˚C W.B.
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to store settings when a power failure occurs.
After power recovery, the unit will automatically re-start in the same settings which were active before
the power failure, except for timer settings.
If the timers were set before a power failure, they will need to be re-set after power recovery.
PREHEATING FUNCTION
In the HEAT operation, the indoor fan may not start for two to five minutes after the unit is turned on
to prevent cold air from blowing out of the unit.
• The built-in protective device may prevent the unit
from operating when used
out of this range.
• Condensation may form on
the air outlet if the unit operates continuously in the
COOL or DRY mode when
humidity is over 80 percent.
DE-ICING FUNCTION
• When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an
automatic de-icer provides heat for about 5 to 10 minutes to remove the ice. During de-icing, the
inside and outside fans stop operating.
• After de-icing is completed, the unit automatically resumes operation in the HEAT mode.
HEATING EFFICIENCY
• The unit employs a heat pump that draws heat from the outside air and releases it into the room.
The outside air temperature therefore greatly affects the heating efficiency.
• If the heating efficiency is reduced due to low outside temperatures, use an additional heater.
• It takes time to warm up and heat the entire room because of the forced air circulation system.
TIPS ON SAVING ENERGY
Below are some simple ways to save energy when you use your air conditioner.
SET THE CORRECT TEMPERATURE
• Setting the thermostat 1°C higher than the desired temperature in the COOL mode and 2°C lower
in the HEAT mode will save approximately 10 percent in power consumption.
• Setting the temperature lower than necessary during cooling operation will result in increased
power consumption.
BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS
• Blocking direct sunlight during cooling operation will reduce power consumption.
• Close the windows and doors during cooling and heating operations.
SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR
CIRCULATION
KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION
MAKE MOST OF THE TIMER OFF FUNCTION
DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN
EXTENDED PERIOD OF TIME
• The indoor unit still consumes a small amount of power when it is not operating.
E-19
BEFORE CALLING FOR SERVICE
The following conditions do not denote equipment malfunctions
UNIT DOES NOT OPERATE
The unit will not operate if it is turned on immediately
after it is turned off. The unit will not operate
immediately after the mode is changed. This is to
protect the internal mechanisms. Wait 3 minutes
before operating the unit.
UNIT DOES NOT SEND OUT WARM AIR
The unit is preheating or de-icing.
ODORS
Carpet and furniture odors that entered into the
unit and the air conditioner's inner component
odors at the early stage of installation may be sent
out from the unit.
CRACKING NOISE
The unit may produce a cracking noise. This sound
is generated by the friction of the front panel and
other components expanding or connecting due to a
temperature change.
A LOW BUZZING NOISE EMITTED
This is a sound emitted when the unit is generating
Plasmacluster ions.
SWISHING NOISE
The soft, swishing noise is the sound of the refrigerant flowing inside the unit.
WATER VAPOUR
• In the COOL and DRY operation, water vapour
can sometimes be seen at the air outlet due to
the difference between the room air temperature and the air discharged by the unit.
• In the HEAT operation, water vapour may flow
out of the outdoor unit during de-icing.
THE OUTDOOR UNIT DOES NOT
STOP
After stopping the operation, the outdoor unit will
rotate its' fan for about a minute to cool down the
unit.
ODOR EMITTED FROM THE
PLASMACLUSTER AIR OUTLET
This is the smell of ozone generated from the
Plasmacluster Ion generator. The ozone
concentration is very small, posing no adverse
effect on your health. The ozone discharged into
the air rapidly decomposes, and its density in the
room will not increase.
If the unit appears to be malfunctioning, check the following points before calling for
service.
IF THE UNIT FAILS TO OPERATE
Check to see if the circuit breaker has tripped or the fuse has blown.
IF THE UNIT FAILS TO COOL (OR HEAT) THE ROOM EFFECTIVELY
Check the filters. If dirty, clean
them.
Make sure windows and doors
are closed tightly.
Check the outdoor unit to make
sure nothing is blocking the air inlet or outlet.
A large number of people in the
room can prevent the unit from
achieving the desired temperature.
Check the thermostat is proper
setting.
Check whether any heat-generating appliances are operating in the room.
IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL
Check whether the remote control batteries have become old
and weak.
Try to send the signal again with
the remote control pointed properly towards the unit’s signal receiver window.
Check whether the remote control batteries are installed with
the polarities properly aligned.
Please call for service when TEMPERATURE INDICATOR on the indicator panel blink.
E-20
Printed in China
TINSEA416JBRZ 05B- CN 1
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.