I-View SDCI-220 User Manual

1
F
CC Statement
This equipment has been strictly tested and reached to Class A,
pursuant to part 15 of the FCC rules, which focus on providing
reasonable protection against harmful exterior interference when
the equipment is operated in a commercial environment. While
wave with constant frequency, which may interrupt the radio
communication if the user does not installed and used in
accordance with the product user manual.
Warning
Changes or modifications not expressly approved by the
manufacturer could void the user’s authority to operate the
equipment.
This device may not cause harmful interference, and this device
must accept any interference received, including interference
that may cause undesired operation.
Shielded cables and I/O cords must be used for this equipment
to comply with relevant FCC regulations.
Caution
Do NOT use power sources other than that specified.
Do NOT expose this appliance to rain or moisture.
2
Table of Content
I. Points for Attention…………………………………………………...4
II. Description of Functions…………………………………………….6
III. Settings of Special Camera…………………………………………8
IV. Steps of Installation………………………………………………...13
V. Menu System…………………………………………………………..15
VI. Specification………………………………………………………….16
VI. Analysis of Normal Troubles………………………………………...17
3
I. Points for Attention
1. Before installing the omni bearing intelligent unit, please read the
operation manual carefully.
2. The camera takes power supply of DC12V/2A. You should assure
that the power supply of the product has an input voltage with load
about 12V rather than a unload voltage of 12V, otherwise the
camera couldn’t work normally.
3. During the process of transportation, storage and installation, the
dome should be avoided of incorrect operations such as heavy
pressing, strong vibration etc. that can cause damage of product as
there are sophisticated optical and electronic devices inside the
machine.
4. Do not attempt to disassemble the camera. In order to prevent
electric shock, do not remove screws or covers. There are no user
serviceable parts inside and only qualified personnel are to service
the unit.
5. Always follow all electrical standards for safety when it is in
operation. Adopt the particular power supply, which is provided
with the dome. RS-485 and video signal should keep enough
distance with high voltage equipments and cables when they are in
transmission. Precautions for anti-lightning and anti-surging should
be taken if necessary.
6. The product should be indoor installed and operated to avoid rain
and moisture. Do not use it in wet places.
If outdoor installation is needed, the closed protect cover should be used
4
and it is absolutely prohibited to use it in open air independently.
7. Do not operate it in case temperature, humidity and power supply are
beyond the limited stipulations.
8. Do not let the video camera aim at the sun or the object with extreme
light whatsoever it is switched on or not. Do not let the video camera
aim at or monitor bright and standstill object for a long time.
9. Do not use aggressive detergent to clean the main body of the video
camera. Wipe dirt with dry cloth. If needed, mild detergent can be used
suitably.
10. Operate the intelligent high-speed spherical video camera with great
care to avoid shock or vibration. It operate incorrectly, machine could
be damaged.
11. Install the video camera in the place where endurance should be enough
large.
12. Should be dust on the lens, you should wipe it with special lens tissue.
5
II. Description of Functions
The speed dome camera is a hi-tech CCTV product, which incorporates
color TV, omni-bearing dome P/T and multifunctional decoder into a whole.
It can largely reduce connection and installation processes of components in
the system, rise up reliability of the system and facilitate installation and
maintenance. Therefore it has advantages of beautiful appearance, compact
structure and easy operation.
1. Integrated Multi-Protocol Decoder
With built-up decoder and integrated multi-protocol, it can integrate many
kinds of communication protocols in maximum. As its baud rate of
communication can be adjusted, it is compatible with main domestic and
foreign systems by easy setting inside the spherical camera, so it has
stronger versatility.
RS485 serial control: addresses of the dome camera 1-1023.
2. Integrated Omni bearing dome P/T
Turning 360º horizontally and continuously with unlimited positions. PAN
speed range:015º/s (constant speed dome PAN: 15º/s); turning 090º
vertically with a speed 015º/s (constant speed dome TILT: 15º/s).
Running stably at low speed with super lower noise. Pictures have
shaking. T
3. High Intelligent Degree
4. Newly-Added Functions
6
he location precision up to ±0.2
a. Support the dome camera to scan horizontally between two points
and scan speed can be modified.
b. Data can be stored with powerless memory.
°.
no
Flexible and Convenient Application: there are many communications
ON ON ON ON ON ON ON ON ON
protocols integrated inside the spherical camera and the baud rates can
be selected from 24000 bps to 19200 bps.
Settings of Addresses of dome Cameras
ID
DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6 DIP-7 DIP-8 DIP-9 DIP-10
0 ON OFF OFF OFF OFF OFF OFF OFF OFF OFF 1 OFF ON OFF OFF OFF OFF OFF OFF OFF OFF 2 ON ON OFF OFF OFF OFF OFF OFF OFF OFF 3 OFF OFF ON OFF OFF OFF OFF OFF OFF OFF 4 ON OFF ON OFF OFF OFF OFF OFF OFF OFF 5 OFF ON ON OFF OFF OFF OFF OFF OFF OFF 6 ON ON ON OFF OFF OFF OFF OFF OFF OFF 7 OFF OFF OFF ON OFF OFF OFF OFF OFF OFF 8 ON OFF OFF ON OFF OFF OFF OFF OFF OFF 9 OFF ON OFF ON OFF OFF OFF OFF OFF OFF
10 ON ON OFF ON OFF OFF OFF OFF OFF OFF
11 OFF OFF ON ON OFF OFF OFF OFF OFF OFF 12 ON OFF ON ON OFF OFF OFF OFF OFF OFF 13 OFF ON ON ON OFF OFF OFF OFF OFF OFF 14 ON ON ON ON OFF OFF OFF OFF OFF OFF 15 OFF OFF OFF OFF ON OFF OFF OFF OFF OFF
1023
States of Coding Switches
Table 1
ON
If you use the FSKY-100 Joystick that the selection ID address must be
match the SDCI-220. The ID address of SDCI-220 must plus “1”
when you use the DVR to control the SDCI-220. i.e. The ID of
SDCI-220 is “ 4 “ and the DVR must select “ Camera 5 “ to control the
PTZ camera which with Pelco “P” protocol.
7
III. Settings of Special Camera
Before installing the spherical camera, please confirm the communication
protocol and baud rate the master controller in the system uses, then set the
coding switches on the back of the camera to be identical with that of the
system in which SW1 is for address of the spherical camera and SW2 is for
communication protocol and baud rate (see attached tables 1,2 and 3).
JP1 is jumper for the terminal resistor.
JP1 is the 120 Ω terminal resistor for RS485 Bus. When short-circuit
terminal is set between “1-2”, the 120 Ω terminal resistor is opened while
it is set between “2-3”, the resistor is connected. Take care that on RS 485
Bus only one farthest spherical camera has the terminal resistor connected
while other devices should have their terminal resistors opened.
SW2
ON
1 2 3 4 5 6
Protocol Select
120Ω term inal resistor is opened for RS485 bus
120Ω term inal resistor is connected on RS485 B us
Speed Dome Address Select
2
2
SW1
ON
1 2 3 4 5 6 7 8 9 10
31
JP
31
JP
8
ID-CODE Set
System
control wire
For Example:
ON
1 2 3 4 5 6 7 8 9 10
Speed Dome Address=1
ON
1 2 3 4 5 6 7 8 9 10
Speed Dome Address=4
ON
1 2 3 4 5 6 7 8 9 10
Speed Dome Address=2
ON
1 2 3 4 5 6 7 8 9 10
Speed Dome Address=18
ON
1 2 3 4 5 6 7 8 9 10
Speed Dome Address=3
ON
1 2 3 4 5 6 7 8 9 10
Speed Dome Address=1023
Notes:
1. Addresses of the dome cameras are denoted by binary code system. ON
means “1” while OFF means “0”.
2. Above coded addresses are only from no.1 to no.20. The codes of
addresses from no.21 to no.1023 can be deduced by analogue.
3. The range of addresses of the spherical cameras is from 1 to 1023.
Settings of communication protocol of the dome camera (DIP1-DIP4
of SW2) and its default baud rate (DIP5-DIP6 of SW2). In case the
default baud rate of the dome camera is not in accordance with that of
the controller, please reset it as per the Table 3 ( means the protocol
has been done).
9
Protocols
Integrated
Samsung ON OFF OFF OFF ON ON B01 ON OFF OFF OFF OFF ON NEON ON OFF OFF OFF OFF ON Santachi OFF ON OFF OFF OFF ON PELCO-D ON ON OFF OFF OFF OFF
PELCO-P PANASONIC ON OFF ON OFF OFF ON Longcomity OFF ON ON OFF OFF ON HUNDA600 ON ON ON OFF OFF ON LILIN OFF OFF OFF ON OFF ON VICON ON OFF OFF ON ON OFF MOLYNX OFF ON OFF ON OFF ON KALATEL ON ON OFF ON ON OFF VCL OFF OFF ON ON OFF ON Reserved ON OFF ON ON OFF ON ALEC OFF ON ON ON OFF ON Utralk ON ON ON ON OFF ON
Protocols mentioned above are suitable for the dome camera. Among them
“Santachi”, “ PELCO-D” and “PELCO-P” have no corresponding orders for
some special functions in the protocols. In order to control some special
functions of the spherical camera, we make some functional transformation
upon some common orders. Normally we take “Call Preset Position / Set
Preset position” to transform, and contents of order transformation are
listed below.
DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6
OFF OFF ON OFF OFF ON
Table 2
Protocol
10
Number
Control Object
Control Object
Control ObjectControl Object
Definition of Keypad Operation
51
52
53
54
55
56
57
58
59
60
61
62
63
Call No. N Preset
Point
Start Scan (low
Supplementary
Control of dome
Power Supply of
Camera
BLC
Zero Illuminance
Screen Display *
D-Zoom On Off
Focus Automatic Manual
Iris Automatic Manual
Mode of White
Balance *
Speed)
Start Scan (middle
Speed)
Start Scan (high
Speed)
Power Supply On Power Supply Off
On Off
On Off
On Off
Automatic Manual
Interior Exterior
ATW One Push WB
Set No. N Preset
Set Start Position of
Set End Position of
Point
Start Patrol
Scan
Scan
Notes:
1. Those Items with “*” have memory function even the dome is switched
off.
2. For those cameras with “menu”, you can use “Screen Display ON” to
control the Menu ON/OFF, and use “Screen Display OFF” to control
Screen Display ON/OFF.
3. For those cameras, which have no “Zero Illuminance” or the function
11
of “Zero Illuminance”, is automatically switched without control, and
then above “Zero Illuminance” is invalid.
4. Notes to “Patrol” Function of the dome camera:
Automatically scan from no.1 to no.16 preset points one by one.
If some points do not have been preset or are cleared out after
presetting, they will be bypassed when patrol is carrying out.
The dwelling time between to preset points is 4 seconds.
The “Patrol” function of the dome camera can be carried out by
presetting no.51 position.
1. Notes to “Scan (auto pan)” Function of the dome camera:
The dome camera makes automatic scan between two specified
positions.
The speeds of scan are divided into three levels. You can call no.
51, 52 and 53 preset position to start scan at speed of 1.5°/ sec,
5°/ sec and 10°/ sec separately.
The dwelling time between the “Start Point” and “End Point” of
scan is 3 seconds.
2. All notes mentioned above are supplementary descriptions under high
speed. All original operations of the control system are unchanged.
Settings of Communication Baud Rate of the dome Camera.
Dip
switch
Baud Rate
1 2 3 4 5 6
2400 bps - - - - OFF OFF 4800 bps - - - - ON OFF 9600 bps - - - - OFF ON
19200 bps - - - - ON ON
12
IV. Steps of Installation
Red : DC12V+ Black : GND
Orange : RS485+ Yellow : RS485-
1.
M ounting Base
2. O uter Tube
3. Shading C over
4. O uter C over
5. Cam era
6. Connecting C able
VIDEO
13
Dimension Drawing
1. Carefully read the operation manual and the points for attention.
2. Carefully set the communication code, baud rate and address of the
dome camera and make confirmation they are correct.
3. Take out the plug of the dome camera and connect external power
supply, RS485 and video wires as per marks on the plug. Take care that the
power supply of the dome camera is DC12V/1.2A and adopt the particular
power supply, which comes with the camera.
Take out the mounting base from the spherical camera; thread the
connecting wire from behind through the central hole of the base. Fix the
base by three screws on the ceiling as per the drawing, and connect the wire
with the ball. Aim the latch in the ball with the notch on the base as per the
drawing, and mount the ball upward to the position and turn it clockwise
until the spring sheet on the base takes effect. In case the wire could not
come out from behind the ceiling, please open a hole on the edge of the
casing for the wiring.
14
V. Menu System
Menu Operation
Setup Preset 57 + [PRESET] or Press [MENU] button of the Joystick controller to
enter the Main Menu. The [FAR] Button of keyboard is the button for confirmation.
1.) The items with “←→ ” are the submenu (See diagram 1). The item with
flashing ”
2.) The items without “←→” are for parameters setting. The item with flashing
first character means being selected.
Move [WIDE] button to up for change selection, move [TELE] button to down
for change selection. Press [FAR] button to enter the needed item. Now
“ icon ”will flash. In the item submenu, move the joystick down to change the
selection.
3.) Press [FAR] button to confirm the changing. After confirmation, “:”of current
item will be flashing, which means the item was selected. Then move the
joystick down to change the parameters.
4.) After modification, press [FAR] button to confirm, then ":" will stop flashing,
and the first character of the selected item will be flashing again, means that the
modification finished and exit available.
5.) <RETURN> is available for each menu page. Select it, and then press [FAR]
button to back to superior menu.
6.) Select <EXIT>, and then press [FAR] button. The screen will show
<EXIT>WAIT, few seconds later, the menu will be closed, and the dome exits
←→
the programming menu
15
VI. Specification
Model SDCI-220N SDCI-220P
Image Sensor
S/N Ratio
Resolution
Lens
Digital Zoom
Shooting Distance
Min Illumination
Tilt /Pan Speed
Scan
Preset:
Protocol
Interface/ Baud Rate
SONY 1/3” Exview II Color CCD
More Than 50dB (AGC Off)
Horizontal: 650 TV Lines
22x Optical Zoom (F1.6, f=3.9~85.8mm)
10x (Setup from factory)
Min. 1 cm (Wide) / 1 meter (Tele)
0..1 Lux. @F1.6
15 degrees/second
360 degrees continuously/90 degrees
64 presets
Multi protocol select by dipswitch
RS-485 / 2400, 4800, 9600 selectable.
Mount type
Power supply
Dimension/Weight
Temperature
16
Ceiling mount for indoor use
DC 12/1.25A; Max. 20 W
Diameter 6 inch/ Approx. 2 Kg
-10 degree C to 50 degree C
VI. Analysis of Normal Troubles
Problems Possible Causes Remedies
No action and images when power is switched on
Abnormal self-inspection. Images with roaring sound of the motor
Normal self-inspection but no images
Successful self-inspection but out of control
Images unstable
Dome Camera out of control
Power supply damaged
or insufficient power Wrong connection of
power supply
Faults in engineering
circuits
Mechanical fault Repair
Tilting camera Place uprightly
Insufficient electrical
power
Wrong connection of
VF circuit
Bad connection of VF
circuit
Camera damaged Replace
Wrong connection of
control signal wire
Mismatched address of
spherical camera
Mismatched protocol
Bad connection of VF
circuit
Insufficient electrical
power
Abnormal
self-inspection
Bad connection of
control wire
Replace
Correct
Remove
Replace with
qualified power
supply and let it close
to the spherical
camera
Correct
Remove
Correct
Reselect
Adjust protocol to
match with the
controller and switch
on again Remove
Replace
Switch on again
Remove
17
Problems on main
frame
Switch on the main
frame
Connect 120Ω
Too heavy load or
longer distance of
communication
resistor to the farthest
camera and let other
cameras to be broken
Increase code
distributor.
Normal problems and their causes and remedies mentioned above are
for reference only. Should you meet other special problems and you can
ask for support from your dealer.
18