I-View FDMO-36XIR, FDMO-27XIR, FDMO-22XIR, FDMO-18XIR User Manual

1
Version: 3.30 Doc. No: 2012092501
2
This equipment has been strictly tested and reached to Class A, pursuant to part 15 of the FCC rules, which focus on providing reasonable protection against harmful exterior interference when the equipment is operated in a commercial environment. While the equipment running, it maybe cause a strong electromagnetic wave with constant frequency, which may interrupt the radio communication if the user does not installed and used in accordance with the product user manual.
Warning
Changes or modifications not expressly approved by the manufacturer could void the user’s
authority to operate the equipment.
This device may not cause harmful interference, and this device must accept any interference
received, including interference that may cause undesired operation.
Shielded cables and I/O cords must be used for this equipment to comply with relevant FCC
regulations.
Caution
Do NOT use power sources other than that specified. Do NOT expose this appliance to rain or moisture.
3
Table of Content
Table of Content
About This Guide ............................................................................................................... 4
Important Safeguards and Warning ................................................................................ 5
Chapter 1 Product Introduction ....................................................................................... 6
1-1. Product Package Content .................................................................................... 6
1-2. Product Overview ................................ ................................................................ 7
1-3. Product Features .................................................................................................. 8
Chapter 2 Installation ........................................................................................................ 9
2-1. Specification ................................ ................................................................ ........ 9
2-2. Outlet Cables Connections ................................................................................ 10
2-3. Baud Rate Setup ................................................................................................ 11
2-4. Camera Address Setup ...................................................................................... 11
2-5. Product with Ceiling Mount Installation ........................................................... 14
Chapter 3 Operation ........................................................................................................ 16
3-1. General Operation ............................................................................................. 16
3-2. Menu System ................................ ................................ ................................ ..... 18
4
About This Guide
About This Guide
Conventions used in this guide
To make sure that you perform certain tasks properly, take note of the following symbols to use throughout this manual.
WARNING: Information to prevent injury to yourself when trying to complete a task.
CAUTION: Information to prevent damage to the components when trying to complete a
task.
IMPORTANT: Information that you must follow to complete a task.
NOTE: Tips and additional information to aid in completing a task.
5
Important Safeguards and Warning
Important Safeguards and Warning
It is not recommended to install this product by unqualified person.
The method and material of installation should be insured for the weight of the product
and enclosure as pan/tilt, camera lens, and so on
Stop using and power off the product if any unusual smell or smoke comes from the camera.
Do not install the camera in an intermittent lighting environment.
Do not aim the camera at the sun or any other strong light source
Do not install the camera where it might be exposed to rain or water.
Do not drop the camera or examine it in severe shocks or vibrations.
Do not touch the front glass of the camera with a dirty or coarse stuff.
Do not install the product under humid conditions, near flammable or explosive gases.
6
Chapter 1: Product Introduction
Chapter 1 Product Introduction
Characterized as fast speed, high decision, low noise and long life, High-speed dome is being popular more and more, it has being the best choice of retail, business, industry, government and entertainment field depending on its good construction, convenient installation and widen range of surveillance.
1-1. Product Package Content
Please check the package content by the following list.
7
Chapter 1: Product Introduction
1-2. Product Overview
Parts Name Description A. Screw holes for speed dome camera bracket B. Speed dome power and RS485 connecting wires
Blue color: RS485 + (Rx +) Yellow color: RS485 – (Rx -) Black color: Revise Red color: Revise
The Blue color wire RS485 + (Rx +) & Yellow
color wire RS485 – (Rx -) for Speed dome controller.
C. BNC video output connector D. Surge protection cable (Yellow Color): Connect to the ground for surge protection
function.
E. Screw hole for Safety-wire connection. F. Camera Cover G. Power core with DC jack for DC 12V input.
Brown color: power DC 12V(+) Blue color: power DC 12V (-)
8
Chapter 2: Installation
1-3. Product Features
Optical Zoom: 36X (f = 3.4mm122.4mm) optical zoom. Day & Night: Switches from color mode to B/W mode automatically. Weatherproof: IP66 and build in fan /heater for all weatherproof environmental structure. Illumination: Super sensitivity of 0.05 lx (color mode) / 0.0015 lx (B/W mode). Resolution: 540-TV line at color imaging horizontal resolution. Masking: 24 Privacy zone masking enables users to veil unwanted zones. Image Freeze: Hold last image during panning. Image Stabilizer: Build in image stabilizer engine. Protocol: Detect Pelco P and D protocol automatically. Speed and Dwell Time: 360 ° per second panning speed and dwell time can be selectable. Home Position: Turn to home position when speed dome inactivate for a while. Tour Group: Provide 8 programmable tour groups. Pan/Tilt scan: 360˚ continuous pan, 90˚ in tilt and 180˚ in auto flip. Preset: Max 128 programmable presets position. Scanning: Three-dimensional scan between two presets. OSD: Support On Screen Menu Display. Remote Addressing: Support remote setup ID address function via RS-485. Default Setup: Support restores function. Proportional: Proportional controlling function. Surge Protection: Inner mounts preventing from surge or lightning strike. Power Protection: Auto protection when power plugs wrong power polarity. Digital I/O: Provide 4 digital inputs and 1 relay output. (Optional). Patrol-learn mode: Patrol-learn mode repetitive use for field application.
9
Chapter 2: Installation
Item/Model
FDMO-36X
FDMO-35X
FDMO-22X
Image Sensor
1/4" SONY Ex-view CCD
1/3“ SONY EXview
HAD CCD II (Effio-E)
Optical Lens
36x (f= 3.4122.4mm)
35x (f= 3.6126mm)
22x (f=3.9~85.8mm)
Digital Zoom
16x
None
Resolution
530 TV lines
650 TV lines
650 TV lines
Video Output
1.0 Vp-p /75Ω (Composite)
S/N
52 dB (AGC Off)
52 dB (AGC Off)
52 dB (AGC Off)
Minimum Illumination
1.4 Lux. (F1.6; IRE50)
0.5 Lux. (F1.6, Color)
0.01 Lux. (F1.6, B/W)
0.03Lux (F1.0/color)
0.01 Lux ( F1.0/B/W)
Day/Night
Auto /Color / B/W
BLC
Multi / Center / Off
Focus
Auto / One-push AF / Menu
AGC
Low / Normal / Middle / High / Off
White Balance
ATW / Menu / Push-look / Indoor / Outdoor / Florescent
Shutter Speed
NTSC: 1/601/10,000 second PAL: 1/501/10,000 second
Image Stabilizer
On / Off
None
Image Freeze
On / Off
None
Privacy Masking
24 Masked locations
None
Panning Speed
5°~360° / Second
Horizontal Scan
360 degree continuously
Vertical Scan
90 degree
Preset
128
Chapter 2 Installation
2-1. Specification
10
Chapter 2: Installation
ID address
S/W: 256; DIP Switch: 64
Interface
RS-485; Half-Simplex
Baud Rate
1200 / 2400 / 4800 / 9600 BPS (Selectable)
Protocol
Pelco P and Pelco D auto detection
Housing
Aluminum
Mount Type
Wall / Ceiling (Optional)
Weatherproof
IP 66 / Build in Fan & Heater
Dimension
6 inches
Environmental
DC12V/3A
Dimension
-35℃~50
Weight
5 Kg
Cable Color
Function Description
Data
Note
Blue
For RS-485 control
RS485 + (Rx +)
Speed dome control.
Yellow
For RS-485 control
RS485 – (Rx -)
Power core
Power input
DC12V
Plug DC12V/3A
power supply
Black
BNC Video cable
Video
2-2. Outlet Cables Connections
11
Chapter 2: Installation
Pin 7
Pin 8
1200/bps
OFF
OFF
2400/bps
ON
OFF
4800/bps
OFF
ON
9600/bps
ON
ON
ID (Pelco P)
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
0
ON
OFF
OFF
OFF
OFF
OFF
1
OFF
ON
OFF
OFF
OFF
OFF
2
ON
ON
OFF
OFF
OFF
OFF
3
OFF
OFF
ON
OFF
OFF
OFF 4 ON
OFF
ON
OFF
OFF
OFF
5
OFF
ON
ON
OFF
OFF
OFF
6
ON
ON
ON
OFF
OFF
OFF
7
OFF
OFF
OFF
ON
OFF
OFF
8
ON
OFF
OFF
ON
OFF
OFF
9
OFF
ON
OFF
ON
OFF
OFF
10
ON
ON
OFF
ON
OFF
OFF
ON
1 2 3 4 5 6 7 8
2-3. Baud Rate Setup
There is an 8-pins switch (Red one) on PCB as showing below:
Baud Rate (Pin 7 and 8 are the selectors for baud rate)
2-4. Camera Address Setup
Address List (Pin 1-6 address selectable)
12
Chapter 2: Installation
11
OFF
OFF
ON
ON
OFF
OFF
12
ON
OFF
ON
ON
OFF
OFF
13
OFF
ON
ON
ON
OFF
OFF
14
ON
ON
ON
ON
OFF
OFF
15
OFF
OFF
OFF
OFF
ON
OFF
16
ON
OFF
OFF
OFF
ON
OFF
17
OFF
ON
OFF
OFF
ON
OFF
18
ON
ON
OFF
OFF
ON
OFF
19
OFF
OFF
ON
OFF
ON
OFF
20
ON
OFF
ON
OFF
ON
OFF
21
OFF
ON
ON
OFF
ON
OFF
22
ON
ON
ON
OFF
ON
OFF
23
OFF
OFF
OFF
ON
ON
OFF
24
ON
OFF
OFF
ON
ON
OFF
25
OFF
ON
OFF
ON
ON
OFF
26
ON
ON
OFF
ON
ON
OFF
27
OFF
OFF
ON
ON
ON
OFF
28
ON
OFF
ON
ON
ON
OFF
29
OFF
ON
ON
ON
ON
OFF
30
ON
ON
ON
ON
ON
OFF
31
OFF
OFF
OFF
OFF
OFF
ON
32
ON
OFF
OFF
OFF
OFF
ON
33
OFF
ON
OFF
OFF
OFF
ON
34
ON
ON
OFF
OFF
OFF
ON
35
OFF
OFF
ON
OFF
OFF
ON
36
ON
OFF
ON
OFF
OFF
ON
37
OFF
ON
ON
OFF
OFF
ON
38
ON
ON
ON
OFF
OFF
ON
39
OFF
OFF
OFF
ON
OFF
ON
40
ON
OFF
OFF
ON
OFF
ON
41
OFF
ON
OFF
ON
OFF
ON
42
ON
ON
OFF
ON
OFF
ON
43
OFF
OFF
ON
ON
OFF
ON
Loading...