ITT Neo-Dyn 100T, 100TC Installation And Operation Manual

NEO-DYN
MODELS 100T AND 100TC
ADJUSTABLE TEMPERATURE SWITCHES,
ENCLOSURE 6N FOR EXPLOSIVE ATMOSPHERES
OPERATION MANUAL
PN 610-0014 E
Enclosure 6N Temperature Switches Page i
WARNING
CAUTION
NOTE
Manual No. 610-0014 Re v E
Neo-Dyn
28150 Industry Drive
Valencia, CA 91355 Tel: (661) 295-4000
World Wide Web: www.neodyn.com
Copyright 2002
ITT Industries
Important Information
The product warranty applicable to this ITT Neo-Dyn® instrument is as stated on page 12 of this manual.
Should any after-delivery problems arise, please contact ITT Neo-Dyn’s Customer Service using the information above. Our normal business hours are weekdays, 7:00 am to 3:30 PM, Pacific Time.
Before installing this Temperature Switch, become familiar with the installation and adjustment instructions in Chapters 2 and 3.
Indicates a hazard which can cause severe personal injury, death, or substantial property damage if the warning is ignored.
Indicates a hazard which will or can cause minor personal injury or property damage if the caution is ignored.
Indicates additional information about a particular item necessary to the operation of the unit.
The Electrical Snap Switch Assemblies shall be installed such that the equipment wiring is protected from mechanical damage by the use of metal conduit or a method providing equivalent protection. The equipment wiring must not be subjected to tension or torque. If it is to be terminated within a potentially explosive atmosphere, a suitably certified termination facility must be used.
This document contains proprietary information, which is the property of Neo-Dyn, a unit of ITT Industries. This document may not be reproduced, either in part or in full, without the consent of ITT Industries.
SPECIAL
CONDITIONS
FOR SAFE USE
Page ii Installation and Operation Manual
TABLE OF CONTENTS
PAGE
CHAPTER 1 INTRODUCTION ................................................. 1
OTHER CONFIGURATIONS .................................................. 2
CUSTOMER SERVICE ............................................................ 2
CHAPTER 2 INSTALLATION AND OPERATION ................. 3
MOUNTING ............................................................................. 3
PROCESS CONNECTIONS .................................................... 4
PROCESS MEDIA ................................................................... 4
ELECTRICAL CONNECTIONS ............................................. 4
POTENTIALLY EXPLOSIVE ATMOSPHERES
(HAZARDOUS LOCATIONS) ................................................ 5
ALLOWABLE PRESSURES AND TEMPERATURES ......... 5
CHAPTER 3 ADJUSTMENTS AND TROUBLESHOOTING . 7
SETPOINT ADJUSTMENT ..................................................... 7
TROUBLESHOOTING ............................................................ 8
CHAPTER 4 SPECIFICATIONS ............................................... 9
STANDARD ............................................................................. 9
OPTIONS ................................................................................ 11
WARRANTY INFORMATION ................................................. 12
Enclosure 6N Temperature Switches Page 1
CHAPTER
1
INTRODUCTION
The Neo-Dyn® Enclosure 6N Temperature Switches described in this manual are weather and explosion-proof, electromechanical sensing devices designed for a wide range of applications in pneumatic and hydraulic systems up to 1500 psig, and for use in Zone 1 Potentially Explosive Atmospheres (Division 1 hazardo us locations). Model 100T has its temperature sensor mounted on its case, while Model 100TC has a remote sensor, mounted at the end of a flexible capillary.
The wetted materials of both models include a welded corrosion-resistant steel (CRES) temperature sensor. Model 100T has a Teflon seal, while Model 100TC has a graphite-filled non-asbestos packing.
Setpoint adjustments are easily made through the adjustable range by turning an adjustment nut located inside the housing.
The standard configuration of these switches will switch up to 11 amp at 125 or 250 VAC, 5 amp resistive at 28 VDC, or 0.5 amp resistive at 125 VDC. When ordered with M Option, the switch is rated for currents to one amp, but its bifurcated gold contacts will reliably switch currents in the milliampere and microampere ranges.
These switches have CE Mark, and they have weatherproof enclosures with IP66 ingress protection and that meet the requirements of NEMA 3. 3R, 3S, 4, 4X and 13. The electrical subassemblies are listed by Underwrites Laboratories, CSA International, Factory Mutual and ATEX.