ITT neo-dyn 100p, neo-dyn 101p, neo-dyn 110p, neo-dyn 180p, neo-dyn 200p Installation And Operation Manual

...
NEO-DYN
MODELS 100P, 101P, 110P, 180P, 200P, 201P
ADJUSTABLE PRESSURE SWITCHES;
MODEL 160P
ADJUSTABLE DIFFERENTIAL PRESSURE SWITCHES,
PN 610-0008 Rev E
INSTALLATION AND
OPERATION MANUAL
Manual No. 610-0008 REV E
Neo-Dyn®
28150 Industry Drive
Valencia, CA 91355 Tel: (661) 295-4000 Fax: (661) 294-1750
World Wide Web: www.neodyn.com
©Copyright 2002
ITT Industries
Important Information
The product warranty applicable to this ITT Neo-Dyn® instrument is as stated on page the last page of this manual.
Should any after-delivery problems arise, please contact ITT Neo-Dyn’s Customer Service using the information above. Our normal business hours are weekdays, 7:00 am to 3:30 PM, Pacific Time.
Before installing this Pressure Switch, become familiar with the installation and adjustment instructions in Chapters 2 and 3
WARNING Indicates a hazard which can cause severe personal injury, death, or substantial
property damage if the warning is ignored.
CAUTION Indicates a hazard which will or can cause minor personal injury or property damage if the
caution is ignored.
NOTE Indicates additional information about a particular item necessary to the operation of the unit.
This document contains proprietary information, which is the property of Neo-Dyn®, a unit of ITT industries. This document may not be reproduced, either in part or in full, without the consent of ITT industries.
Enclosure 3X Pressure Switches Page i
TABLE OF CONTENTS
CHAPTER 1 INTRODUCTION ............................................................................................................ 1
CUSTOMER SERVICE .................................................................................................................... 2
OTHER CONFIGURATIONS .......................................................................................................... 2
CHAPTER 2 INSTALLATION ............................................................................................................. 3
MOUNTING ..................................................................................................................................... 3
PROCESS CONNECTIONS ............................................................................................................. 4
PROCESS MEDIA ............................................................................................................................ 4
POTENTIALLY EXPLOSIVE ATMOSPHERES (HAZARDOUS LOCATIONS) ...................... 4
ELECTRICAL CONNECTIONS...................................................................................................... 5
CHAPTER 3 ADJUSTMENTS AFTER INSTALLATION .................................................................. 6
SETPOINT ADJUSTMENT ............................................................................................................. 6
CHAPTER 4 TROUBLESHOOTING ................................................................................................... 7
CHAPTER 5 SPECIFICATIONS .......................................................................................................... 8
WARRANTY INFORMATION .......................................................................................................... 14
Enclosure 3X Pressure Switches Page ii
CHAPTER
1
INTRODUCTION
The Neo-Dyn® Enclosure 3X Switches described in this manual are weather-proof, electromechanical sensing devices designed for a wide range of applications in pneumatic and hydraulic systems up to 10,000 psig. Models 100P, 101P, 110P, 200P, and 201P are gauge pressure switches, Model 180P is a vacuum switch, and Model 160P is a differential pressure switch.
The most common wetted materials of these pressure and vacuum switches include a polyimide (Kapton) sensing diaphragm, nitrile O-ring, and aluminum alloy or corrosion resistant steel (CRES) pressure port. CRES diaphragms and all-welded constructions are also available in some models for corrosive pressure media and are standard on the temperature switches.
Setpoint adjustments are easily made through the adjustable range by turning an adjustment nut located inside the housing. On Models 101P and 201P this adjustment is external.
The standard configuration of these switches will switch up to 15 amp at up to 250 VAC in a single-pole configuration, and up to 11 amp at up to 250 VAC in a double-pole configuration. When ordered with M Option, the switch is rated for currents to one amp, but its bifurcated gold contacts will reliably switch currents in the milliampere and microampere ranges.
These switches have CE Mark, and they all have weatherproof enclosures with IP66 ingress protection and that meet the requirements of NEMA 3. 3R, 3S, 4, 4X and 13. The internal switch elements are UL and CSA recognized components.
Enclosure 3X Pressure Switches Page 1
ADJUSTMENT KNOB, MODELS 101P, 201P
PRESSURE
PORT
CONDUIT FITTING, 1/2-14 NPT FEMALE ALTERNATE LOCATION (SEE BELOW)
CONDUIT FITTING 1/2-14 NPT FEMALE STANDARD LOCATION (SEE BELOW)
HOUSING COVER
4X COVER SCREW
LOW-PRESSURE PORT, MODELS 152P, 160P VACUUM PORT, MODEL 180P 1/4-18 NPT FEMALE
Figure 1. Models 100P, 101P, 110P, 160P, 180P,
200P, 201P: Enclosure 3X Adjustable Pressure Switches
Pressure Port Configurations Vary with Model and Range
Hidden lines indicate mounting holes under the cover (see Mounting in Chapter 2).
Chapter 5 contains complete specifications for these Adjustable Pressure Switches.
CUSTOMER SERVICE
If you have any questions about these Pressure and Temperature Switches that are not covered in this manual, you can contact Neo-Dyn® or our representatives in several ways.
The Neo-Dyn® customer service phone number is (661) 295-4000. Our customer service department is open from 7:00 am to 3:30 p.m. Pacific Time.
Our Internet site is www.neodyn.com; it includes lists of sales representatives and distributors.
OTHER CONFIGURATIONS
WARNING The models described in this manual are also available in special and factory-set
configurations. For these units, follow the installation and operating instructions herein, except adhere to the pressure and electrical limits marked on the units.
Enclosure 3X Pressure Switches Page 2
Installation of these Neo-Dyn® Enclosure 3X pressure switches is straightforward. However, they must be installed by a qualified electrician, in compliance with all local and national electrical codes.
WARNING Electrical hazard WARNING Do not make electrical connections while power is on. WARNING Always check for multiple circuits. WARNING Always make sure grounding is adequate. WARNING Do not remove switch while under pressure.
MOUNTING
CHAPTER
2
INSTALLATION
The Pressure Switch can be mounted directly to the process connection if there is no significant vibration and the fluid lines are capable of supporting the weight. It can also be attached to a flat surface, such as a wall or panel, using .250 in. diameter or M6 socket-head cap screws through the mounting holes that are accessed by removing the housing cover; allow .5 in. (12.7 mm) screw length above the mounting surface. These holes are located on two corners of a 2.72 inch (6.91 cm) square, or 3.85 inches (9.77 cm) apart on a 45° diagonal. Do not over tighten the screws when replacing the cover.
Note that on certain models and ranges the housing of the pressure fitting has a large outside diameter that extends below the mounting surface, requiring either a cutout in that surface, or having the pressure fitting overhang an edge. These models are 100P and 101P, Range 1; 110P; 142P; 152P; 160P; and 180P
Enclosure 3X Pressure Switches Page 3
Loading...