ITT Bell & Gossett ZoneTrol II Z-1, ZS-1, McDonnell & Miller ZoneSmart Installation, Operation And Service Instructions

Instruction Manual 210711
U
L
®
C
US
LISTED
REVISION A1
Bell & Gossett®ZoneTrol II
Model Z-1
McDonnell & Miller ZoneSmart
Model ZS-1
Installation, Operation and Service Instructions
INSTALLER: PLEASE LEAVE THIS MANUAL FOR THE OWNER’S USE.
SAFETY INSTRUCTION
This safety alert symbol will be used in this manual and on the unit safety instructions decal to draw attention to safety related instructions. When used, the safety alert symbol means ATTEN-
TION! BECOME ALERT! YOUR SAFETY IS INVOLVE D! FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN A SAFETY HAZARD.
DESCRIPTION
The Bell & Gossett ZoneTrol II and McDonnell & Miller Zone­Smart Pump Controllers are designed to control 120 VAC circulating pumps in hydronic systems.
Max.
T-stat Number of Max.
Model Current Zones HP/Pump
Z-1 / ZS-1 0.085 1 1/3
LED DEFINITION
Power LED will illuminate when input power is applied to the controller. Zone LED will illuminate when relay is energized.
MECHANICAL INSTALLATION INSTRUCTIONS
The pump controller should be securely mounted on a wall near the pumps using four #8 screws (not included).
ELECTRICAL INSTALLATION INSTRUCTIONS
WARNING: Electrical Shock Hazard
Electrical connections are to be made by a qualified electrician in accordance with all applicable codes, ordi­nances and good practices Disconnect and lock out the power before making electrical connections. Failure to fol­low these instructions could result in serious personal injury and/or death.
1. Disc onnec t the elec trica l sup ply to the pump befo re installing the controller.
2. Refer to the applicable wiring diagram
- Figure 1: Cold Start Boiler
- Figure 2: Tankless Coil
3. Verify that the circulator(s) do not exceed the electrical rat­ing of the controller.
4. Make electrical connections according to the applicable wiring diagram. Run the pump power through the holes in the controller chassis to the applicable L/N terminals. Keep 120 VAC and 24 VAC wiring separate. All 120 VAC wiring should be 14 AWG (minimum) copper electrical. Perform all wiring in accordance with applicable codes.
5. Run the thermostat wires through the grommet(s) in the controller chassis and connect to the appropriate R/W ter­minals. Keep 24 VAC wiring separate from 120 VAC wiring.
WARNING: Electrical Shock Hazard
When wiring per the Tankless Coil Application, pump controller and boiler aquastat must be on the same circuit and have a common disconnect. Failure to follow these instructions may introduce a secondary source of power resulting in personal injury or death.
}
}
To TT on boiler
To
circulator
Input
Power
120/1/60
Factory
Installed
Jumper
6
NO
56NC4NC4NO3HNG
}
}
To
thermostat
T/W T/RC
To ZC
To
circulator
}
}
Input
Power
120/1/60
Remove
Factory
Installed
Jumper
6NO6NC4NC4NO3HNG5
TYPICAL WIRING SCHEMATICS
Figure 1: Cold Start Boiler
When a thermostat calls for heat, the corresponding circulator will start and the 5-6 NO end switch will close to enable the boiler.
Figure 2: Tankless Coil (Remove Jumper)
When a thermostat calls for heat, the corresponding circulator will start when the boiler temperature reaches the low limit setting