Sleeve-mount repeater installation depends on the type of meter socket.
Mount
Meter Socket TypeDescription
RinglessA ringless mounted meter installs under the meter
box lid, which is hinged at the top of the box.
RingedA rimmed meter box
Required ToolsThe following tools are necessary for sleeve-mount repeater installation:
•Tamper seals and associated meter installation/removal tools
•Panduit Wave-Ty installation tool (optional). This tool cuts excess cable
and applies tension to the tension band.
Installing on a
Ringless Meter
Socket
A ringless meter s ocket does not use a mete r seal ring between th e meter and th e
meter socket. Instead, the meter is secured in the meter socket by a lid. To install
a repeater on a ringless meter socket, do the following steps.
IMPORTANTThe followin g inst ructi ons sho uld be cons idere d s upplement al to
the meter installation and removal procedures for your utility. Follow all applicable procedures and regulations when performing meter installation.
StepAction
1Remove tamper seals.
2Verify that th e service is compatible with the repeater.
3Remove the meter socket lid.
4Pull the meter from the socket.
5Insert the repeater into the socket.
DRAFT
Chapter 2 - Repeater Installation9
TDC-0613-000 10/04
Page 2
Sleeve-Mount Repeaters
StepAction
6Replace the meter socket lid.
NOTEIf needed, trim the breakaway rim on the repea ter sleev e using
diagonal so that the socket lid will fit over the repeater.
7Place the antenna cover over the antenna on the top of the repeater
sleeve.
8Secure the band around the repeater, pulling to tighten.
9Tighten the tension band using a tension setting tool.
10Clip off the extra band material.
11S nap the mete r into the repeater socket.
12Attach the ring making sure to catch the antenna cover lip under the
ring band.
Catch
cover lip
under ring
10Fixed Network Repeater Installation Guide
TDC-0613-000 10/04
13Install a tamper seal in the ring band and on the meter socket lid.
DRAFT
Page 3
Sleeve-Mount Repeaters
Installing on a
Ringed Meter Socket
A ringed meter socket uses a meter sealing ring to secure the meter to the socket.
To install a repeater on a ringed meter socket, do the following steps.
StepAction
1Remove tamper seals.
2Verify that the service is compatible with the re peater.
3Remove the meter seal ring.
4Pull the meter from the socket.
5Insert the repeater sleeve into the meter socket.
6Secure a meter seal ring between the repeater and the meter socket.
DRAFT
Chapter 2 - Repeater Installation11
TDC-0613-000 10/04
Page 4
Sleeve-Mount Repeaters
StepAction
7Place the antenna cover over the antenna on the top of the repeater.
8Secure the antenna cover band around the repeater, pulling to tighten.
9Tighten the tension band using a tension setting tool.
10Clip off the extra band material.
11Insert the meter into the repeater socket.
12Fixed Network Repeater Installation Guide
TDC-0613-000 10/04
DRAFT
Page 5
Sleeve-Mount Repeaters
StepAction
12Attach the meter seal ring making sure to catch the antenna cover lip
under the ring band.
Catch
cover lip
under ring
13Replace the tamper seals.
DRAFT
Chapter 2 - Repeater Installation13
TDC-0613-000 10/04
Page 6
Sleeve-Mount Repeaters
14Fixed Network Repeater Installation Guide
TDC-0613-000 10/04
DRAFT
Page 7
Chapter 3
Repeater Configuration
Getting Started
OverviewRepeater configuration and troubleshooting is performed in the field using two
components:
•
Repeater Programmer communicates with repeaters and endpoints. You
can use the progra mmer in the f ield to t roublesho ot repeat er probl ems and
optimize network performance. The programmer is connected to your
computer using a serial cable and powered by a 5 volt power cord.
•
Itron QuickTerminal is a terminal emulation application, similar to Hyper-
Terminal or ProComm.
Navigating in
QuickTerminal
QuickTerminal displays three windows: the Data window, the Control Panel,
and the Remote Unit Connection wind ow . The Remote Unit Connection window
appears following a successful connection with a repeater.
Data
window
Control
Panel
DRAFT
Chapter 3 - Repeater Configuration15
TDC-0613-000 10/04
Page 8
Installing QuickTerminal
Installing QuickTerminal
OverviewQuickTerminal may be installed directly on your machine or run directly from
the CD. Note that running QuickTerminal from the CD will result in some performance and speed loss.
RequirementsThe following software and hardware requirements must be met to run Quick-
Terminal.
RequirementDescription
Microsoft WindowsWindows XP, 2000, 98, ME, or NT Service
Pack 6a
Microsoft .NET FrameworkVersion 1.1. Available as part of Windows XP
and 2000, or available from Microsoft.
http://windowsupdate.microsoft.com
Serial PortAvailable serial port capable of communi-
cating at 38400 baud rate
Serial Port AdapterOptional
If your computer does not have a serial port,
you may need to use a USB serial port adapter .
Installing
QuickTerminal
Power Ada pterOptional
A power adapter for the 5 volt power cord is
required to operate the programmer in a
vehicle.
Itron recommends installing QuickTerminal directly on your configuration
machine. To install QuickTerminal, do the follo wing steps.
StepAction
1Insert the QuickTerminal CD.
2Navigate to the Install folder and double-click setup.exe.
The QuickTerminal setup wizard launches.
16Fixed Network Repeater Installation Guide
TDC-0613-000 10/04
DRAFT
Page 9
Installing QuickTerminal
StepAction
3Click Next to accept the de fault insta llation pat h or browse for an
alternate path.
4Click Next to confirm ins tallation. QuickTerminal installs.
Running
QuickTerminal from
CD
DRAFT
5Click Close.
The QuickTerminal icon will appear on your desktop and in the Start
menu.
To run QuickTerminal directly from the CD, do this.
•Insert the QuickTerminal CD.
•Navigate to the Run folder and double-click
QuickTerminal.exe.
Chapter 3 - Repeater Configuration17
TDC-0613-000 10/04
Page 10
Communicating with a Repeater
Launching
QuickTerminal
To launch the QuickTerminal application, do this.
•Double-click the QuickTerminal icon on your desktop or select
QuickTerminal
.
Communicating with a Repeater
Setting
Communication
Options
You may need to adjust the COM port or baud rate settings for communicating
with the repeater. To set communication options, do the following steps.
StepAction
1Connect the programmer to your computer using the serial cable.
2Launch QuickTerminal.
3Press F2.
NOTETo view or minimize the Control Panel, press F2. To enter
command mode, press
4From Settings, select a COM port. The default is COM port 1.
5Select a baud rate setting. The default baud rate is 38400.
6Click Connect.
•If the COM port is available, the message
appears. As the programmer begins to read ERT endpoints and
repeaters, data will appear.
•If the COM port is avail able but th e repeater is not co nnected, the
port will open but no data will appear.
Start >
ESC three times.
COM1 opened OK
Connecting to a
Remote Repeater
•If the COM port is not available or not pr esent on the machi ne, an
error message appears.
NOTEData may not immediately display if the programmer is not
able to read nearby endpoints or repeaters. If no data displays, check
that the repeater is connected by removing and re-inserting the power
cord into the repeaters. A status message should appear.
An All Call (ACALL) command causes all of the repeaters in communication
distance to move to a single frequen cy. You must perform a remot e call prior to
communicating with a repeater. To connect to a remote repeater, do the following ste ps.
StepAction
1
From the Co ntrol Panel, click Remote Call. The remote call processes
and available repeat ers display.
2In the data window, enter the password.
3Press Enter to accept the command channel frequency.
NOTE If your util ity has opted t o use a frequen cy other than t he standard
frequency of 9100, enter your frequency.
18Fixed Network Repeater Installation Guide
TDC-0613-000 10/04
DRAFT
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.