Itron INTELISG Users Manual

OpenWay® Riva Intelis Gas Meter
Installation Guide
Technical
Communications
knowledge to shape your future
Identification
OpenWay® Riva Intelis Gas Meter Installation Guide
23 May 2018
Copyright
© 2018 Itron, Inc. All rights reserved.
Confidentiality Notice
The information contained herein is proprietary and confidential and is being provided subject to the condition that (i) it be held in confidence except to the extent required otherwise by law and (ii) it will be used only for the purposes described herein. Any third party that is given access to this information shall be similarly bound in writing.
Trademark Notice
Itron is a registered trademark of Itron, Inc.
All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.
Suggestions
For more information about Itron or Itron products, see www.itron.com.
If you have questions or comments about the software or hardware product, contact Itron Technical Support Services.
Contact
• Email: support@itron.com
• Internet: support.itron.com
• Telephone Itron Technical Support North America: 1-877-487-6602
For technical support contact information by region, go to www.itron.com and select your country and language.

Contents

Chapter 1 Important Safety and Compliance Information.............................. 1
USA, FCC Part 15 compliance............................................................................................................................. 1
Canada, ISED compliance.................................................................................................................................... 2
RF Exposure (FCC/ISED)...................................................................................................................................... 2
Electromagnetic compatibility...............................................................................................................................2
Intrinsic safety.......................................................................................................................................................3
Lithium battery...................................................................................................................................................... 3
Transportation classication................................................................................................................................. 3
Electrostatic discharge..........................................................................................................................................3
Electrostatic ignition hazard..................................................................................................................................3
Device cleaning.....................................................................................................................................................4
Do Not Drop .........................................................................................................................................................4
Product notication...............................................................................................................................................5
Chapter 2 The OpenWay® Riva Intelis Gas Meter........................................... 6
OpenWay Riva Intelis Gas Meter models............................................................................................................. 6
Intelis meter components..................................................................................................................................... 6
OpenWay Riva Intelis Gas Meter LCD....................................................................................................... 7
Integrated 500G ERT module.....................................................................................................................8
Internal shut off valve................................................................................................................................. 8
Auto disconnect conguration............................................................................................................9
Intelis meter specications................................................................................................................................... 9
Intelis meter dimensions .................................................................................................................................... 10
Chapter 3 Installing the Intelis Meter.............................................................. 11
Prior to start-up...................................................................................................................................................11
Start-up...............................................................................................................................................................11
The Intelis meter capacity and pressure loss test.............................................................................................. 12
Chapter 4 Proving and Calibrating the Intelis Meter......................................13
Prover types........................................................................................................................................................13
Proving operations..............................................................................................................................................14
Conguring Test Mode.............................................................................................................................14
Entering Test Mode.................................................................................................................................. 14
Recording prover consumption................................................................................................................15
Exiting Test Mode.....................................................................................................................................15
Adjusting the Intelis meter calibration......................................................................................................15
Chapter 5 OpenWay Riva Intelis Gas Meter Maintenance.............................16
OpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 iii
Proprietary and Confidential
Chapter 1 Important Safety and Compliance Information
This section provides important information for your safety and product compliance.
USA, FCC Part 15 compliance
This device complies with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Operation is subject to the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference that may cause undesirable operation.
This device must be installed to provide a separation distance of at least 20 centimeters (7.9 inches) from all persons to be compliant with regulatory RF exposure.
USA, FCC Class B-Part 15
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio or TV technician for help.
Modifications and Repairs
To ensure system performance, this device and antenna shall not be changed or modified without the express approval of Itron. Per FCC rules, unapproved modifications or operation beyond or in conflict with these instructions for use could void the user's authority to operate the equipment.
OpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 1
Proprietary and Confidential
Important Safety and Compliance Information
Canada, ISED compliance
Compliance Statement Canada Déclaration de Conformité
This device complies with Innovation, Science and Economic Development Canada (ISED) license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Under Innovation, Science and Economic Development Canada (ISED) regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.
RF Exposure (FCC/ISED)
This equipment complies with radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Cet équipement est conforme aux limites d'exposition aux radiations dans un environnement non contrôlé. Cet équipement do it être installé et utilisé à distance minimum de 20 cm entre le radiateur et votre corps. Cet émetteur ne doit pas être co-localisées ou opérant en conjonction avec tout autre antenne ou transmetteur.

Electromagnetic compatibility

Caution
high quality, shielded, and correctly terminated. Unapproved modifications or operation beyond or in conflict with these use instructions may void the authority's authorization to operate the equipment.
: Use only approved accessories with this equipment. All cables must be
OpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 2
Proprietary and Confidential

Intrinsic safety

Warning: Substitution of components may impair intrinsic safety.

Lithium battery

Warning: Follow these procedures to avoid injury to yourself or others.
• The lithium battery may cause a fire or chemical burn if it is not disposed of properly.
• Do not recharge, disassemble, heat above 100°C Celsius (212°Fahrenheit), crush, expose to water, or incinerate the lithium battery. Fire, explosion, and severe burn hazard.
• The battery used in this device may present a risk of fire or chemical burn if mistreated.
• Keep the lithium battery away from children.
• Batteries must not be replaced or modified in any way.
Important Safety and Compliance Information
Transportation classification
The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, the Itron device is considered an operating transmitter and receiver and cannot be shipped by air. All product returns must be shipped by ground transportation.

Electrostatic discharge

Warning
Before installation, discharge electrostatic buildup by touching a metal pipe or other earth-grounded metal object prior to touching the meter body, register housing, or Itron device.
: Internal circuit components can be sensitive to electrostatic discharge.

Electrostatic ignition hazard

Warning
touching the Itron device.
: Verify the area is not hazardous when installing, servicing, cleaning, or
OpenWay® Riva Intelis Gas Installation Guide TDC-1782-000 3