Installing 40W and 50W ERT® Modules
Revision B
Page 2
ii
®
Installing 40W and 50W ERT
PUB-0126-001 4/04
Trademark Notice
®
ERT
, Itron, and ReadOne are registered trademarks of Itron, Inc. All other product names and logos in this manual are used for
identification purposes only and may be trademarks or registered trademarks of their respective companies.
Copyright Notice
Copyright © 2003 by Itron, Inc. All Rights Reserved. Your company has the right to reproduce this contract document, provided that such reproduction shall be subject to the same use and disclosure restrictions contained in the Confidentiality and Non-Disclosure paragraphs in the Sales Contract.
Compliance Statement FCC ID: EO940GN-1 CANADA: 864-K1124
This equipment has been tested and found to comply with Part 15 of the FCC rules and R.S.S.-210 of Industry and Science Canada. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference that may cause undesired operation of the device. Complies with IC: CNR-210; en conformite´ avec IC: CNR-210.
Transportation Classification Itron classifies and ships model 40W and 50W ERT modules as non-hazardous material. The proper shipping name is Lithium Batteries contained in Equipment, Class 9, UN3091, Packing Group II.
Modules
The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, the model 40W and 50W ERT modules are considered operating transmitters and receivers and cannot be shipped by air.
Applicable Patents
U.S. Patent numbers: 4,614,945; 4,733,169; 4,799, 059; 4, 786, 903; 4, 876, 700. Canadian Patent numbers: 1,254, 949; 1, 267, 936; 1, 282, 118.
Warning
Only authorized Itron personnel should attempt repairs on Itron equipment. Attempts to do so by others might void the warranty and/or any maintenance contract with your company. Unauthorized service personnel might also be subject to shock hazard on some Itron equipment if removal of protective covers is attempted.
Related Documents
ReadOne Pro
®
ERT Programming Guide TDC-0027
Water ERT Ordering Guide PUB-0063-001
Contact Information
If you have suggestions on how we can improve this document, please send them to:
Itron, Inc. 2401 North State Street Waseca, MN 56093 Phone 1-800-392-3185
Printed in the U.S.A.
Installing 40W and 50W ERT Modules
Page 3
iii
TABLE OF CONTENTS
Section Page
Section 1 INTRODUCTION
1.1 Installation Features ........................................................................................................................... 1–1
1.2 Physical Features .............................................................................................................................. 1–1
1.3 Functional Features ........................................................................................................................... 1–1
1.4 Meter-ERT Compatibility ..................................................................................................................... 1–2
1.5 40W and 50W ERT Configurations .................................................................................................... 1–3
1.5.1 Badger RTR and ADE .............................................................................................................. 1–3
1.5.2 ABB Digital, Scancoder and InVISION .................................................................................. 1–3
1.5.3 Hersey Translator .................................................................................................................... 1–4
1.5.4 Hersey ER ................................................................................................................................ 1–4
1.5.5 Schlumberger ARB V and ProRead ........................................................................................ 1–5
1.5.6 Sensus ECR and ICE .............................................................................................................. 1–5
1.6 Installation Kits .................................................................................................................................... 1–6
1.7 Tools and Materials You Must Supply ................................................................................................. 1–7
Section 2
INSTALLING THE BADGER DIRECT-MOUNT ............................................................................................... 2–1
Section 3
INSTALLING THE AMCO InVISION, DIGITAL OR SCANCODER DIRECT-MOUNT ....................................... 3–1
Section 4
INSTALLING THE SHLUMBERGER ARB V OR PROREAD REGISTER-MOUNT ......................................... 4–1
Section 5
INSTALLING THE SENSUS ECR REGISTER-MOUNT .................................................................................. 5–1
Section 6
INSTALLING A REMOTE-MOUNT ................................................................................................................... 6–1
Section 7
PIPE MOUNT (AND REGISTER-MOUNTS REQUIRING A BAND CLAMP) .................................................... 7–1
Appendix A
CONNECTING CABLE WIRES WITH GEL CONNECTORS ......................................................................... A–1
Appendix B
ITRON INSTALLATION KITS (ILLUSTRATED) .............................................................................................. B–1
REVISION HISTORY ...................................................................................................................................... R–1
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 4
1-1
SECTION 1. INTRODUCTION
This section overviews the installation procedures, and the physical and functional features of the 40W and 50W ERT modules. This section also lists the specific meters that are compatible with these modules and illustrates their various configurations. Finally, this section lists the available installation kits and the tools and materials you’ll need to install the 40W and 50W modules.
1.1 Installation Procedures
INSTALLATION PROCEDURES FOR THE 40W AND 50W ARE IDENTICAL
1.2 Physical Features
The only visible difference is that the 40W contains one battery, and the 50W contains two batteries.
The 40W contains one battery
The 50W contains two batteries
1.3 Functional Features
The 50W ERT module can be programmed two ways:
1. Wake-Up Mode: A “wake-up” signal is sent from the meter-reading device* to the ERT module, which responds with data transmission. This configuration requires an FCC license.
2. “Bubble-Up” Mode. In this mode, the FCC requires that no wake-up signal be sent. The transmission of data from the ERT module occurs at preset times. No wake-up signal is needed and no FCC license is required for this type of installation. To turn off the transmitter from the meter­reading device, refer to the operating instructions for that device.
The 40W ERT module functions only in the “wake-up” mode.
*Such as a Data Command Unit (DCU) or DataPac
Installing 40W and 50W ERT Modules
Page 5
1.4 Meter-ERT Compatibility
Before you install a 40W or 50W ERT module, make sure it is the correct one for the meter. Match the part number in Table 1-1 with the meter. Refer to Water ERT® Meter Compatibility list for details and exceptions.
Table 1-1. Meter-ERT Compatibility
40W PART NUMBER
ERW-0008-001
ERW-0008-002
50W PART NUMBER
ERW-1008-501
ERW-1008-502
ERW-1008-506
INSTALL ON THESE METERS
BADGER RTR
• Direct-Mount
• Remote-Mount
AMCO (ABB) DIGITAL
• Direct-Mount
• Remote-Mount
AMCO (ABB) SCANCODER
• Direct-Mount
• Remote-Mount
AMCO InVISION
• Remote-Mount
• Register-Mount
1-2
SCHLUMBERGER ARB V
ERW-0008-003
ERW-0008-004
ERW-0008-005
ERW-1008-503
ERW-1008-504
ERW-1008-505
ERW-1008-505
ERW-1008-501
• Remote-Mount
• Register-Mount
SCHLUMBERGER PROREAD
• Remote-Mount
• Register-Mount
SENSUS ECR,ICE BADGER ADE
• Remote-Mount • Remote-Mount
• Register-Mount • Direct-Mount
HERSEY TRANSLATOR
• Remote-Mount
• Register-Mount
HERSEY ER
• Remote-Mount
• Register-Mount
CAUTION: The 50W ERT for Hersey ER, Precision, and AMCO Digital registers must be programmed to the appropriate meter type to prevent the possibility of reporting inaccurate consumption values. To perform this function, refer to the instructions supplied with the ReadOne® Pro ERT Programming Guide TDC­0027-005 (or higher). Also, verify that the ReadOne Pro used for programming is software version 5.0 or higher, and your ROCL is base VO9 or higher. Each of these attributes can be verified from the various screens on the ReadOne Pro.
(Note: ReadOne Pro software version 5.0 does not support 25G ERT modules. Contact Customer Care at 1-800-635-8725 for additional information.)
NOTE: Although all procedures are illustrated with photos of the 40W module, the installation procedure for the 50W is exactly the same.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 6
1-3
1.5 40W & 50W ERT Configurations
The next three pages illustrate the installation configurations described in this manual.
1.5.1 Badger
0109001092
DIRECT-MOUNT. The ERT module mounts directly on the bracket supplied by Badger.
REMOTE-MOUNT. The ERT module is wired to the unterminated cable, which can be up to 500 feet in length. Three feet to 100 feet can be ordered from Badger (typically 25 feet is supplied by Badger). The remote can be mounted on a pipe or flat surface.
1.5.2 AMCO (ABB) Digital, Scancoder and InVISION
01545
DIRECT MOUNT. The AMCO Digital, Scancoder or InVISION ERT module mounts directly on the bracket supplied by AMCO.
01265F
REMOTE-MOUNT. The ERT module is wired to the cable, which can be up to 300 feet in length. The remote can be mounted on a pipe or flat surface.
CAUTION: Be sure to attach correct ERT module to appropriate meter register.
Installing 40W and 50W ERT Modules
Page 7
1.5.3 Hersey Translator
1-4
01863
REMOTE-MOUNT. The ERT module is wired to the cable, which can be up to 300 feet in length. The remote can be mounted on a pipe or flat surface.
1.5.4 Hersey ER
01872
REMOTE-MOUNT. The ERT module is wired to either the 5 foot or 25 foot ER cable assembly. The remote can be mounted on a pipe or flat surface.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 8
1-5
1.5.5 SCHLUMBERGER ARB V and ProRead
01342F
The illustration shows a remote-mount on a Neptune T-10 meter equipped with a ProRead register. The ARB V register is similar in appearance to the ProRead register. The remote can be mounted on a pipe or flat surface, with a cable up to 300 feet in length. A band clamp is used to mount the ERT module to the register.
CAUTION: Be sure to attach an ARB V register to an ARB V ERT and a ProRead register to a ProRead ERT. ARB V and ProRead ERTs do not have the same part number.
1.5.6 SENSUS ECR OR ICE
01349e
Sensus meters must be equipped with ECR or ICE registers. The remote-mount cable can be up to 300 feet in length. The remote can be mounted on a pipe or flat surface. A band clamp is used to mount the ERT module to the register.
Installing 40W and 50W ERT Modules
Page 9
1–6
1.6 Installation Kits
Configuration Kit (part number CFG-0067-001). This kit contains the accessories for remote-mounting a 40W or 50W Scancoder ERT module to an adapter plate, wood, or sheet metal surface. The contents of this kit are illustrated in Appendix B.
Configuration Kit (part number CFG-0067-002). This kit contains the accessories for remote-mounting all other 40W or 50W ERT modules (including the ABB Digital ERT) described in this manual to adapter plates, wood, or sheet metal surfaces. The contents of this kit are illustrated in Appendix B.
40W & 50W Pipe Mount and Register-Mount Installation Kit. Use this kit to remote-mount the 40W or 50W ERT module on a pipe, or to direct-mount the 40W or 50W ERT module on a register. One of these kits can be ordered for each ERT module. These kits come with a choice of three band clamp sizes. To select the correct size, see Water ERT Ordering Guide (PUB-0063-001). The contents of this kit are illustrated in Appendix B. NOTE: There is an additional charge for this kit.
To order the above kits, see the Water ERT Ordering Guide (PUB-0063-001).
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 10
1–7
1.7 Tools and Materials You Must Supply
The tools and material required depend on whether you are installing a direct-mount ERT module or a remote­mount ERT module; and if it is remote, the way it is mounted (pipe or flat surface). You must supply some or all of the tools and material listed in Tables 1–2 and 1-3 below. Also, If you remove and replace registers, you might need tools specified by register manufacturer.
NOTE: For remote-mount installations, customer-supplied cable is required (Badger supplies 3 feet to 100 feet, typically 25 feet); cable length should not exceed 300 feet (Badger 500 feet). Itron recom­mends 19-26 gauge, pre-bonded or solid conductor wire with a maximum diameter of .082" (individual wire with insulation).
Table 1-2. Suggested Tool List
Tool or Material Required
Klein model D234-6C pliers, 3M ScotchLok® Model E-9C Cartridge Tool, or similar tool for crimping wire connectors
Side-cutting pliers for cutting wires, remote cables, and cable ties (NOTE: Klien model D234-6C pliers satisfy this require­ment).
Torx® screwdriver, size T-10 security head, for the RTR mounting setscrew (Badger only)
Torx screwdriver, size T-15 for the screws that attach ERT modules to integral RTRs and Remote Mounting Brackets
ReadOne® Pro unit for programming and checking ERT modules
Medium flat-blade screwdriver for band clamps
Medium flat-blade, for the screws that attach adapter plates to pipe brackets and the screws that attach remote mounting brackets to adapter plates
Required for Direct-Mount or Integral ERT Modules
XX
X
Required for Remote ERT Modules
Mounted on Pipe
Mounted on Wood or Sheet Metal
X
X
X
XXX
X
XX
X
X
X
X
X
Cable ties for securing remote cables to pipes or other supports
Standard or long-nose pliers for pulling cable ties tight
1/4-inch nut driver other tool for seating tamper seals
Medium Phillips screwdriver for the screws that attach remote mounting brackets to wood or sheet-metal surfaces
1/16-inch awl for removing tamper seals
Wire strippers for removing insulation from cables and wires
Installing 40W and 50W ERT Modules
X
X
X
X
X
X
X
XX X
X
XX
Page 11
Table 1-3. Screw Anchors for Masonry Surfaces
1-8
Description
Plastic-Lipped Anchor
Lead-Lipped Anchor
Solid Masonry Anchor
All Purpose Masonry Anchor
Length
0.875
1.00 inch
1.375 inch
Hole Size
3/16 inch drill
5/16 drill
5/16 drill x 5/8 inch deep
Flange or Flush Mount
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 12
2-1
SECTION 2. INSTALLING THE BADGER DIRECT-MOUNT
Check the part number on the label to make sure the ERT module matches the meter (reference Table 1-1).
UP
Always install an ERT module right side up, as indicated by the on the label.
Make sure you have a Badger register with a direct-mount bracket (as shown in Section 1).
CAUTION: If an ERT module is dropped from a height of 3 feet or more, there may be damage to the circuit board. DO NOT install the ERT module.
NOTE
The register may or may not be mounted on the meter when performing the following steps.
2-1
Obtain an ERT module for the Badger
register. ERT modules have three
wires:
one wire with green insulation
one wire with red insulation
one wire with black insulation
2-2
Connect the black wire from the register to the black wire from the ERT module with a gel connec­tor, as described in Appendix A of this manual. Do the same with the red wire. The green wire is not used.
01547
NOTE: Fold the unused green wire down into the ERT module housing.
Installing 40W and 50W ERT Modules
01547a
Page 13
01547b
2-2
2-3
Push the gel connectors down into the ERT module housing here.
2-4
Place the ERT module in the slot of the bracket.
The edge of the ERT module housing should be against the ribbed side in the slot.
NOTE: A gasket is not required.
Obtain four Torx-head ERT module mount­ing screws.
2-5
Install the mounting screws as shown. Hand tighten each screw.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 14
2-3
01079
2-6
If you have not already done so, con­nect the register to the water meter and fully tighten the mounting screw as directed by Bad­ger Meter.
NOTE
The register can be installed on the meter in four different positions with respect to the direction of water flow (refer to the directions that come with the meter or register).
If the standard Torx screw is used (as shown), a wire seal is not necessary.
2-7
If the optional slotted and drilled RTR screw is used,
install a wire seal through the drilled screw from here to here,
or as specified by utility policy.
To complete the installation:
Program and check the ERT module as described in ReadOne Pro® Programming Guide (TDC-0027-XXX).
01080
Installing 40W and 50W ERT Modules
Page 15
SECTION 3. INSTALLING THE AMCO (ABB) SCANCODER, InVISION, OR DIGITAL DIRECT-MOUNT
Check the part number on the label to make sure the ERT module matches the meter (reference Table 1-1).
UP
Always install an ERT module right side up, as indicated by the on the label.
CAUTION: If an ERT module is dropped from a height of 3 feet or more, there may be damage to the circuit board. DO NOT install the ERT module.
NOTE: The direct-mount bracket must be ordered from AMCO.
Direct-mount bracket
3-1
01545F
AMCO Scancoder/Digital or InVISION with a direct-mount bracket.
completely out of its location
and separate the
ERT module mounting bracket
meter register collar.
NOTE
The register may or may not be mounted on the meter when performing the following steps.
3-1
Push this
hollow pin
from the
01535
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 16
3-2
3-2
Obtain the correct ERT module for
use with the InVISION or Scancoder
register.
Obtain a 40W or 50W AMCO Digital
ERT module if connecting to a
Digital register.
01547z
00219
3-3
Strip 1/2-inch of insulation from the end of the black, red and green wires.
3-4
Place the ERT module mounting bracket on the work surface with its inside up.
01551Z
Installing 40W and 50W ERT Modules
Page 17
01557
3-3
3-5
Place the ERT module on the mounting bracket.
NOTE: A gasket is not required.
00983
3-6
Bring the red, black and green ERT module
wires out the wire exit hole in the ERT module
mounting bracket.
01722
3-7
Obtain four Torx-head ERT module mounting screws. These screws are shipped in the same box with AMCO Scancoder ERTs, and in a separate box for AMCO Digital ERTs. The screws are shown here approximately actual size.
3-8
Install all four ERT module mounting screws
as shown. Hand tighten each screw.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 18
3-4
01541
Install the green wire under this register screw head. Tighten the screw fully.
3-9
Install the black wire under this register screw head. Tighten the screw fully.
Install the red wire under this register screw head. Tighten the screw fully.
IMPORTANT Be sure to install the wires around the screws in a clockwise direction, as shown. If you don't, the wires may par­tially or completely come out from under the screw heads as you tighten them. Also, make sure no insulation is com­pressed under the screw head, or the wire might not make good contact.
Install the ERT module and mounting bracket on the meter register adapter collar.
01558x
3-10
01542
Installing 40W and 50W ERT Modules
Page 19
3-11
Replace this hollow pin
where you removed it from in
step 3-1
3-5
01535
The meter and ERT module
assembly should now look like this.
To complete the installation:
Program and check the ERT module as described in ReadOne Pro® Programming Guide (TDC-0027-XXX).
See programming Caution on
01546F
page 1-2.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 20
4-1
SECTION 4. INSTALLING THE SCHLUMBERGER ARB V OR PROREAD REGISTER-MOUNT
Check the part number on the label to make sure the ERT module matches the meter (reference Table 1-1).
Always install an ERT module right side up, as indicated by the on the label.
CAUTION: If an ERT module is dropped from a height of 3 feet or more, there may be damage to the circuit board. DO NOT install the ERT module.
NOTE: Schlumberger's ProRead register must be programmed with a Schlumberger ProRead Programmer as 3-wire to work properly with the ERT. Schlumberger ARB V registers are not programmable.
01342z
UP
4-1
Schlumberger ARB V Register (ProRead is similar)
Pull the bottom edge of the
wire terminal enclosure cover
out and down as shown .
01547z
Installing 40W and 50W ERT Modules
01672
4-2
Obtain a 40W or 50W Schlumberger ARB V ERT module if connecting to an ARB V register.
Obtain a 40W or 50W Schlumberger ProRead ERT module if connecting to a ProRead register.
Page 21
4-4
Connect the cable wires from the
ERT to the register screw termi-
nals as shown at right.
4-2
4-3
Strip 1/2-inch of insulation from end of black, green and red wires on ERT.
Connect the black cable wire to
this screw.
Connect the green cable wire to
this screw.
Connect the red cable wire to
this screw.
IMPORTANT Be sure to install the wires around the screws in a clockwise direc­tion, as shown. If you don't, the wires may partially or completely come out from under the screw heads as you tighten them. Also, make sure no insulation is com­pressed under the screw head, or the wire might not make good contact.
01681F
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 22
4-3
4-5
Put the wire terminal enclosure cover back on the register.
When you have finished, the register and wires should look like this.
01681x
01551
Installing 40W and 50W ERT Modules
4-6
Place the ERT module mounting bracket on the work surface with its inside up.
Page 23
4-7
Place the ERT module on the
mounting bracket as shown, with
the wires in the remote mounting
bracket cable exit notch..
4-4
4-8
The ERT module and mounting
bracket should look like this.
01552
01014
4-9
Make sure the register wires are still positioned in the exit notch.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 24
4-5
4-10
Get four Torx-head mounting screws from the bulk supply. The screws are shown at right approximately actual size.
00983
01016
4-11
Install the Torx-head mounting screws here.
Hand tighten each screw.
NOTE Refer to Section 7 for instructions on how to install the ERT module to the register.
Installing 40W and 50W ERT Modules
Page 25
5-1
SECTION 5. INSTALLING THE SENSUS ECR OR ICE REGISTER MOUNT
Check the part number on the label to make sure the ERT module matches the meter (reference Table 1-1). Always install an ERT module right side up, as indicated by the “UP” symbol on the label. CAUTION: If an ERT module is dropped from a height of 3 feet or more, there may be damage to the circuit board. DO NOT install the ERT module.
NOTE The register may or may not be mounted
on the meter when performing the following steps.
01547x
Sensus ECR register
Invensys ICE register
01547
5-1
To remove the cable entrance cover from the meter register, turn it coun­terclockwise approximately 1/4 turn.
01547y
5-2
Obtain a 40W or 50W Sensus ECR/ ICE ERT.
5-3
Strip 1/2-inch of insulation from the end of the black, green and red wires on ERT.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 26
5-2
5-4
Install the black wire from the ERT under the
register screw head marked "B"
on the top of the register. Tighten the screw fully.
Install the red wire under the register
screw head marked "R"
on the top of the register. Tighten the screw fully.
Install the green wire under the register
screw head marked "G"
on the top of the register. Tighten the screw fully.
01548x
IMPORTANT Be sure to install the wires around the screws in a clockwise direction, as shown. If you don't, the wires may partially or completely come out from under the screw heads as you tighten them. Also, make sure no insulation is compressed under the screw head, or the wire might not make good contact.
01558x
5-5
To reinstall the cable bracket on the meter register, place it over the wires, push down and turn clock­wise until it lines up as shown.
01549x
Installing 40W and 50W ERT Modules
Page 27
5-6
Place the ERT module mounting bracket on the work surface with its inside up.
5-3
01551
Place the ERT module on the
mounting bracket the way shown
here, with the
in the remote mounting bracket
cable exit notch.
5-7
wires
01552x
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 28
5-4
5-8
The ERT module and mounting
bracket should look like this.
01014
01015
5-9
Make sure the register wires are still in the mounting bracket exit notch.
Installing 40W and 50W ERT Modules
Page 29
5-10
Get four Torx-head mounting
screws
from the bulk supply. The screws
are shown approximately actual
size.
5-5
5-11
Install the Torx-head screws here.
Hand tighten every screw.
NOTE Refer to Section 7 for instructions on how to install the ERT module to the register.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 30
6-1
SECTION 6. INSTALLING A REMOTE MOUNT
Check the part number on the label to make sure the ERT module matches the meter (reference Table 1-1).
Always install an ERT module right side up, as indicated by the on the label.
CAUTION: If an ERT module is dropped from a height of 3 feet or more, there might be damage to the circuit board. Do not install the ERT module.
NOTE: All 40W & 50W ERT modules can be remote mounted above grade outside.
Get a supply of 19-26 gauge, pre-bonded or solid conductor wire with a maximum diameter of .082" (individual wire with insulation). Note the Badger RTR register and the ADE register come with 3 feet to 100 feet of cable (typically 25 feet). All other cable is to be supplied by the customer. Total cable length should not exceed 300 feet (500 feet for Badger).
INSTALLATION TIP: Some installers prefer to first run the wire from the water meter to the point where the ERT will be installed and then connect the wire to the register, and lastly connect the other end of the wire to the ERT. Any order is acceptable, and this is simply installer preference. If you use existing wire, do a continuity check first.
NOTE: If customer-supplied wire is not color coded red, green, and black, care must be taken that each of the 3 individually colored wires is installed correctly. For example, if customer supplied wire is pink, gray and yellow, and the installer connects at the register the pink wire to the register's red (R), the gray wire to the register's black (B), and the yellow wire to the register's green (G), then the installer must connect the other end of those wires to the ERT as follows:
• Pink wire to ERT red wire
• Gray wire to ERT black wire
• Yellow wire to ERT green wire.
UP
The register may or may not be mounted on the meter when performing the following steps.
Installing 40W and 50W ERT Modules
NOTE
6-1
Obtain adequate supply of wire (in­staller supplied).
Using a wire stripper, remove about 3" of the outer insulation from the wire.
Strip 1/2-inch of insulation from each of the three color coded wires.
Page 31
TO CONNECT TO AMCO (ABB) DIGITAL, InVISION, OR SCANCODER REGISTER
6-2
Remove the terminal cover from the
register.
Connect the red wire to the terminal
labeled “R”.
Connect the green wire to the
terminal labeled “G”.
Connect the black wire to the
terminal labeled “B”.
6-2
See programming CAUTION on page 1-2
TO CONNECT TO BADGER RTR AND ADE REGISTERS:
6-3
There is no need to attach wire, since it is already factory installed and supplied with the Badger RTR and ADE registers.
If more cable is needed, use gel connectors, as described in Appendix A. Do not exceed 500
01090
feet in total length.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 32
6-3
TO CONNECT TO HERSEY TRANSLATOR REGISTER:
6-4
Remove the screw terminal
cover from the register. Install
the red wire under
this screw head.
Tighten the screw fully.
Install the green wire
under this screw head.
Tighten the
screw fully.
Install the black wire under
this screw head.
Tighten the screw fully.
Install the screw terminal cover.
IMPORTANT
Be sure to install the wires around the screws in a clockwise direction, as shown. If you don’t, the wires may partially or completely come out from under the screw heads as you tighten them. Also, make sure no insulation is compressed under the screw head, or the wire might not make good contact.
6-5
To assemble the ER pickup assembly follow the instructions furnished with the meter register. Refer to section 6.14 to connect the cable to the ERT module.
Installing 40W and 50W ERT Modules
01873
Page 33
TO CONNECT TO SCHLUMBERGER ARB V OR PROREAD REGISTERS:
6-6
Remove the screw terminal cover. Install the black wire under this screw head. Tighten the screw fully.
Install the green wire under this screw head. Tighten the screw fully.
Install the red wire under this screw head. Tighten the screw fully.
6-4
Install the screw terminal cover.
TO CONNECT TO SENSUS ECR OR ICE REGISTERS:
6-7
Remove the screw terminal cover. Install the black wire under this screw head. Tighten the screw fully.
Install the green wire under this screw head. Tighten the screw fully.
Install the red wire under this screw head. Tighten the screw fully.
IMPORTANT
Be sure to install the wires around the screws in a clockwise direction, as shown. If you don’t, the wires may partially or completely come out from under the screw heads as you tighten them. Also, make sure no insulation is compressed under the screw head, or the wire might not make good contact.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 34
6-5
TO CONNECT THE ERT MODULE TO THE METER REGISTER USING GELCAP CONNECTORS:
6-8
G
B
R
To connect A 40W or 50W ERT module to the meter register (other than Badger), connect the wires as follows:
• Black to black
• Green to green
• Red to red
NOTE: For instructions on how to connect gelcap connectors, see Appendix A.
6-9
B
Bare
01549XY
Installing 40W and 50W ERT Modules
G
To connect a 40W or 50W ERT mod­ule to a Badger register with a black­insulated cable, connect as follows:
• Red to red
R
Black
• Black to black
• Green to bare wire
NOTE: For instructions on how to connect gelcap connectors, see Appendix A.
This configuration does cut cable feature (Badger register equipped with a brown-insulated cable does support cut cable).
not support the
Page 35
G
6-6
6-10
To connect a 40W or 50W ERT module to a Badger register with a brown-insu­lated cable, connect as follows:
Bare
B
Brown
R
• Red to red
• Green to green
• Black to black
• Fold the unused bare wire backward along the brown cable, as shown.
This configuration supports the cut cable feature (Badger register equipped with a black-insulated cable does not support cut cable).
NOTE: The 40W must have 3 wires to support the cut cable feature.
6-11
To connect a 40W or 50W ERT module to a Hersey ER register
R
connect as follows:
R
Bare
B
B
G
Black
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
• Red to black
• Bare to green
• Black to red
NOTE: For instructions on how to connect gelcap connectors, see Appendix A.
Page 36
6-7
Wiring Instructionsfor 6-11:
1. Cut black connector off the end of pulser assembly about 1” from end. (See Picture)
2. Install the white cable tie about 2” from the end of the pulser assembly that was just cut and properly tighten.
3. Remove about 1 1/2 inches of the cables outer jacket and separate the 3 wires.
4. Place the Black wire from the ERT and the Red wire from the pulser assembly into a gel connector and properly crimp down on the connector. See Appendix A.
5. Place the Red wire from the ERT and the Black wire from the pulser assembly into a second gel connector and properly crimp down on the connector.
6. Place the Green wire from the ERT and the Bare wire from the pulser assembly (remember to tightly twist bare wire) into a third gel connector and properly crimp down on the connector.
01874
Remove
Push the connectors and ERT
module wires down into the ERT
module housing.
Installing 40W and 50W ERT Modules
6-12
01549
Page 37
01551
6-13
Place the ERT module mounting bracket on the work surface with its inside up.
6-14
Place the ERT module on the
mounting bracket as shown, with
the cable routed through the exit
notch.
6-15
The ERT module and mounting
bracket should now look like this.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
01552F
01014G
Page 38
01015
6-8
6-16
Make sure the register cable is still in the mounting bracket cable exit notch.
6-17
Get four Torx-head ERT module
mounting screws from the bulk
supply. The screws are shown
approximately actual size.
00983
6-18
Install the Torx-head ERT module mounting screws where shown.
Hand tighten every screw.
01016
Installing 40W and 50W ERT Modules
Page 39
6-9
6-19
Drill three pilot holes in the mounting surface the proper size for the mounting screws, as shown.
CAUTION Make sure that you do not damage anything on the other side of the surface you are going to mount the remote mounting bracket on when you drill the holes and install the screws.
IMPORTANT The holes for the bottom two screws must be on a horizontal line.
00498
1-21/32"
3-3/8"
DRILLING TEMPLATE--ACTUAL SIZE
If you have several installations, you can make a durable template as follows:
Drill a hole through the lug slot of a mounting bracket, where indicated, to mark the position of that screw. Keep this permanent template for future use.
NOTE
If you do not use the mount­ing screws furnished with the ERT module, be sure to use screws that have the same size head as those furnished with the ERT module.
INSTALLATION TIP
00222F
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 40
6-20
Get three mounting screws from
the configuration kit.
The screws are shown approxi-
mately actual size.
6-21
Screw the top mounting screw part way into the mounting surface.
6-10
00499
01022
01022
6-22
Continue to drive the screw into the mounting surface until the back side of the mounting lug recess on the ERT module remote mounting bracket will just barely slide under the screw head.
01015
Installing 40W and 50W ERT Modules
Page 41
6-11
6-23
Push the ERT module upward until the screw head is all the way into the mounting lug recess.
01023
01020F
6-24
Install and fully tighten these two mounting screws.
6-25
Get two new tamper seals
from the 40W/50W Configuration
Kit.
01026
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 42
01359F
6-12
6-26
Place a new tamper seal over each of these mounting screws.
Push both tamper seals all the way
1/4-inch nut driver
Installing 40W and 50W ERT Modules
6-27
into place with a
or similar tool.
01360F
Page 43
6-13
6-28
When a tamper seal is fully seated,
top of the tamper seal
is about 3/32-inch below the
top of the screw recess.
the
01029F
6-29
After the plastic tamper seals have been
installed, the ERT module should look
like this.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
01352
ERT module on wood or sheet metal surface.
Page 44
SECTION 7. PIPE MOUNTS (AND REGISTER MOUNTS REQUIRING A BAND CLAMP)
7-1
Always install an ERT module right side up, as indicated by the on the label.
UP
NOTE: Use this section to install an ERT module on a Schlumberger or Sensus register.
7-1
Get a bracket
and a band clamp
from the pipe mount/
register mount
installation kit.
00864x
00775x
7-2
Loosen the
band-clamp screw
until the
end of the band
comes loose from the
screw assembly.
00867
7-3
Push the end of the band through this hole in the bracket.
00787
Installing 40W and 50W ERT Modules
Page 45
7-2
7-4
Place the band clamp around the pipe on which you want to mount the bracket. Push the end of the band through this hole in the band clamp.
00788
If mounting to a register, install a 4-1/2-inch band clamp around the Schlumberger or Sensus register.
7-5
Push the
end of the band
clamp into the
entrance to
the screw
assembly.
00789
00460
7-6
Start tightening the
band clamp screw.
00790
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 46
00791
7-3
7-7
When the end of the band gets about this far out of this side of the screw assembly, push it through this hole in the pipe bracket.
Then tighten the band-clamp screw three or four more turns to make sure the end of the band does not pop back out on this side of the pipe bracket.
00792
7-8
Position the pipe bracket where you want it on the pipe.
Position the band clamp as shown. Then fully tighten the band clamp screw.
When the band clamp screw is fully tightened, the band clamp and bracket should look like this.
00865
Installing 40W and 50W ERT Modules
Page 47
7-4
7-9
Place an adapter plate on the bracket.
This adapter-plate screw boss goes into this bracket recess.
This adapter-plate screw boss goes into this bracket recess.
00869
00868
7-10
When the adapter plate is properly positioned on the pipe bracket, it looks like this.
7-11
Obtain two adapter-plate mounting screws
(shown here actual size) from the pipe
mount/register mount Installation kit.
00779
7-12
00797
Install the adapter-plate mount­ing screws in these holes.
Hand tighten both screws.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 48
7-13
Install the two
remote mounting screws
to attach the ERT module to the
adapter plate.
7-5
01353
01354
7-15
Installing 40W and 50W ERT Modules
Install two plastic tamper seals as described in Steps 6-21 through 6-24.
7-14
The ERT module installation should now look like this.
Page 49
A-1
APPENDIX A. CONNECTING CABLE WIRES WITH GEL CONNECTORS
A-1
Push the wires that are to be con­nected together as far as possible into the connector.
00653
CAUTION Do not strip any insulation from the ends of the wires before you push them into the connector.
00984
00985
00978
A-2
Place the connector (with wires) into the jaws of the crimping tool.
A-3
Crimp the connector by squeezing the handles until the connector looks like this. Continue to apply pressure for three seconds.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 50
00654
A-2
00664
A-4
If using a 3M Scotchlok Model E-9C Cartridge Tool, push the ends of the wires to be connected into the connector at the end of the crimping tool, as shown.
Then squeeze the crimping tool handle until it pushes the connector (now crimped) out of the tool when you release the handle.
00659x
A connector is crimped properly if the top of the movable, yellow center part
is flush with the
top of the connector body.
00665
CAUTION Crimping the connectors sometimes squeezes some sealant out of them. The sealant protects the inside of the connector against insects, moisture, and other contaminants.
The sealant may cause minimal eye and skin irrita­tion. Avoid eye contact. Avoid prolonged or re­peated skin contact.
Installing 40W and 50W ERT Modules
Page 51
B-1
APPENDIX B. ITRON INSTALLATION KITS
Configuration Kit (part number CFG-0067-001)
Remote Mounting Bracket
3 Mounting Screws
2 Plastic Tamper Seals
3 Gel Connectors
2 Cable Ties
01787
NOTE: Configuration kits are shipped in bulk, with 30 kits per box.
Refer to Water ERT Ordering Guide (PUB-0063-001) for part numbers of all components.
Specifications for the installation kit screws used to attach 40W/50W ABB Scancoder ERT modules to wood, sheet metal, or masonry surfaces are given at right. The screws are shown approximately actual size.
10-12 x 1 1/2 Phillips Pan Head Tapping Screw, Corrosion Resistant Steel
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 52
Remote Mounting Bracket
4 Remote Mounting
Bracket Screws
3 Mounting Screws
2 Plastic Tamper Seals
3 Gel Connectors
2 Cable Ties
B-2
Configuration Kit (part number CFG-0067-002)
01788
NOTE: Configuration kits are shipped in bulk, with 30 kits per box.
Refer to Water ERT Ordering Guide (PUB-0063-001) for part numbers of all components.
Specifications for the screws used to attach remote mounting brackets to wood or sheet metal surfaces are given at right. The screws are shipped in bulk. The screws are shown here approximately actual size.
10-12 x 1 1/2 Phillips Pan Head Tapping Screw, Corrosion Resistant Steel
Installing 40W and 50W ERT Modules
Page 53
B-3
40W/50W Pipe Mount and Register Mount Installation Kit
Adapter Plate
00775
Two screws for attaching an ERT module to the adapter plate
Pipe Bracket
Band Clamp for attaching the pipe bracket to a pipe or for installing an ERT module to a Schlumberger or Sensus register (see Section 7)
Two screws for attaching the adapter plate to the pipe bracket
Specifications for the screws supplied in the Pipe/Register Mount Installation Kit are given below. The screws are shown approximately actual size.
For Mounting Adapter Plates on Pipe Brackets For Mounting 40W/50W ABB Scancoder
ERT Modules on Adapter Plates
8-16 x 1/2 Type AB slotted pan head tapping screw, corrosion resistant steel
8-16 x 1 Type AB slotted pan head tapping screw, corrosion resistant steel
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 54
R-1
REVISION HISTORY
(PUB-0126-001)
REV
A 45015 Initial Release
A1 45701 Added installation instructions for the 50W ERT
CCO
Description of change
DATE
1-4-01
APPROVALS
Engineering
Marketing
Engineering
Marketing
Tim Muotka
1-4-01
Janet Penz
1-4-01
A2 Added Hersey Translator Register
A3 Added programming Caution.
47127
47890
10-05-02
10-22-02
9-15-03
9-15-03
Engineering
Tim Muotka
Marketing
Janet Penz
Engineering
Joe Fritz
Marketing
Allen Rogers
Installing 40W and 50W ERT Modules
Page 55
REVISION HISTORY
(PUB-0126-001)
R-2
REV
CCO
Description of change
A4 47998 Added Badger ADE.
A5 48088 Added AMCO InVISION and Invensys ICE registers.
DATE
10-23-03
10-22-03
12-17-03
12-10-03
APPROVALS
Engineering
Marketing
Engineering
Tim Muotka
Marketing
Allen Rogers
Joe Fritz
Allen Rogers
B
48449
Added Hersey ER registers.
5-4-04
5-4-04
Engineering
Tim Muotka
Marketing
Allen Rogers
Engineering
Marketing