This equipment has been tested and found to comply with Part 15 of the FCC rules and R.S.S.-210 of Industry and Science Canada.
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference that may cause undesired operation of the device. Complies with IC: CNR-210; en conformite´ avec IC: CNR-210.
Transportation Classification
Itron classifies and ships model 40W and 50W ERT modules as non-hazardous material. The proper shipping name is Lithium
Batteries contained in Equipment, Class 9, UN3091, Packing Group II.
Modules
The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, the
model 40W and 50W ERT modules are considered operating transmitters and receivers and cannot be shipped by air.
Only authorized Itron personnel should attempt repairs on Itron equipment. Attempts to do so by others might void the warranty and/or
any maintenance contract with your company. Unauthorized service personnel might also be subject to shock hazard on some Itron
equipment if removal of protective covers is attempted.
Related Documents
ReadOne Pro
®
ERT Programming GuideTDC-0027
Water ERT Ordering GuidePUB-0063-001
Contact Information
If you have suggestions on how we can improve this document, please send them to:
Itron, Inc.
2401 North State Street
Waseca, MN 56093
Phone 1-800-392-3185
Printed in the U.S.A.
Installing 40W and 50W ERT Modules
Page 3
iii
TABLE OF CONTENTS
SectionPage
Section 1
INTRODUCTION
1.1 Installation Features ........................................................................................................................... 1–1
1.2 Physical Features .............................................................................................................................. 1–1
1.3 Functional Features ........................................................................................................................... 1–1
REVISION HISTORY ...................................................................................................................................... R–1
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 4
1-1
SECTION 1. INTRODUCTION
This section overviews the installation procedures, and the physical and functional features of the 40W
and 50W ERT modules. This section also lists the specific meters that are compatible with these
modules and illustrates their various configurations. Finally, this section lists the available installation
kits and the tools and materials you’ll need to install the 40W and 50W modules.
1.1 Installation Procedures
INSTALLATION PROCEDURES FOR THE 40W AND 50W ARE IDENTICAL
1.2 Physical Features
The only visible difference is that the 40W contains one battery, and the 50W contains two batteries.
The 40W contains one battery
The 50W contains two batteries
1.3 Functional Features
The 50W ERT module can be programmed two ways:
1. Wake-Up Mode: A “wake-up” signal is sent from the meter-reading device* to the ERT module,
which responds with data transmission. This configuration requires an FCC license.
2. “Bubble-Up” Mode. In this mode, the FCC requires that no wake-up signal be sent. The
transmission of data from the ERT module occurs at preset times. No wake-up signal is needed
and no FCC license is required for this type of installation. To turn off the transmitter from the meterreading device, refer to the operating instructions for that device.
The 40W ERT module functions only in the “wake-up” mode.
*Such as a Data Command Unit (DCU) or DataPac
Installing 40W and 50W ERT Modules
Page 5
1.4Meter-ERT Compatibility
Before you install a 40W or 50W ERT module, make sure it is the correct one for the meter. Match
the part number in Table 1-1 with the meter. Refer to Water ERT® Meter Compatibility list for details
and exceptions.
Table 1-1. Meter-ERT Compatibility
40W PART NUMBER
ERW-0008-001
ERW-0008-002
50W PART NUMBER
ERW-1008-501
ERW-1008-502
ERW-1008-506
INSTALL ON THESE METERS
BADGER RTR
• Direct-Mount
• Remote-Mount
AMCO (ABB) DIGITAL
• Direct-Mount
• Remote-Mount
AMCO (ABB) SCANCODER
• Direct-Mount
• Remote-Mount
AMCO InVISION
• Remote-Mount
• Register-Mount
1-2
SCHLUMBERGER ARB V
ERW-0008-003
ERW-0008-004
ERW-0008-005
ERW-1008-503
ERW-1008-504
ERW-1008-505
ERW-1008-505
ERW-1008-501
• Remote-Mount
• Register-Mount
SCHLUMBERGER PROREAD
• Remote-Mount
• Register-Mount
SENSUS ECR,ICE BADGER ADE
• Remote-Mount • Remote-Mount
• Register-Mount • Direct-Mount
HERSEY TRANSLATOR
• Remote-Mount
• Register-Mount
HERSEY ER
• Remote-Mount
• Register-Mount
CAUTION: The 50W ERT for Hersey ER, Precision, and AMCO Digital registers
must be programmed to the appropriate meter type to prevent the possibility of
reporting inaccurate consumption values. To perform this function, refer to the
instructions supplied with the ReadOne® Pro ERT Programming Guide TDC0027-005 (or higher). Also, verify that the ReadOne Pro used for programming
is software version 5.0 or higher, and your ROCL is base VO9 or higher. Each
of these attributes can be verified from the various screens on the ReadOne
Pro.
(Note: ReadOne Pro software version 5.0 does not support 25G ERT modules. Contact Customer
Care at 1-800-635-8725 for additional information.)
NOTE: Although all procedures are illustrated with photos of the 40W module, the installation procedure for
the 50W is exactly the same.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 6
1-3
1.540W & 50W ERT Configurations
The next three pages illustrate the installation configurations described in this manual.
1.5.1 Badger
0109001092
DIRECT-MOUNT. The ERT module mounts
directly on the bracket supplied by Badger.
REMOTE-MOUNT. The ERT module is wired to
the unterminated cable, which can be up to 500
feet in length. Three feet to 100 feet can be
ordered from Badger (typically 25 feet is supplied
by Badger). The remote can be mounted on a
pipe or flat surface.
1.5.2 AMCO (ABB) Digital, Scancoder and InVISION
01545
DIRECT MOUNT. The AMCO Digital, Scancoder
or InVISION ERT module mounts directly on the
bracket supplied by AMCO.
01265F
REMOTE-MOUNT. The ERT module is wired to
the cable, which can be up to 300 feet in length.
The remote can be mounted on a pipe or flat
surface.
CAUTION: Be sure to attach correct ERT module to appropriate meter register.
Installing 40W and 50W ERT Modules
Page 7
1.5.3 Hersey Translator
1-4
01863
REMOTE-MOUNT. The ERT module is wired to the cable, which can be up to 300 feet in
length. The remote can be mounted on a pipe or flat surface.
1.5.4 Hersey ER
01872
REMOTE-MOUNT. The ERT module is wired to either the 5 foot or 25 foot ER cable assembly.
The remote can be mounted on a pipe or flat surface.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 8
1-5
1.5.5 SCHLUMBERGER ARB V and ProRead
01342F
The illustration shows a remote-mount on a Neptune T-10 meter equipped with a ProRead
register. The ARB V register is similar in appearance to the ProRead register. The remote can
be mounted on a pipe or flat surface, with a cable up to 300 feet in length. A band clamp is
used to mount the ERT module to the register.
CAUTION: Be sure to attach an ARB V register to an ARB V ERT and a ProRead register
to a ProRead ERT. ARB V and ProRead ERTs do not have the same part number.
1.5.6 SENSUS ECR OR ICE
01349e
Sensus meters must be equipped with ECR or ICE registers. The remote-mount cable
can be up to 300 feet in length. The remote can be mounted on a pipe or flat surface. A
band clamp is used to mount the ERT module to the register.
Installing 40W and 50W ERT Modules
Page 9
1–6
1.6Installation Kits
Configuration Kit (part number CFG-0067-001). This kit contains the accessories for remote-mounting a
40W or 50W Scancoder ERT module to an adapter plate, wood, or sheet metal surface. The contents of
this kit are illustrated in Appendix B.
Configuration Kit (part number CFG-0067-002). This kit contains the accessories for remote-mounting all
other 40W or 50W ERT modules (including the ABB Digital ERT) described in this manual to adapter
plates, wood, or sheet metal surfaces. The contents of this kit are illustrated in Appendix B.
40W & 50W Pipe Mount and Register-Mount Installation Kit. Use this kit to remote-mount the 40W or 50W
ERT module on a pipe, or to direct-mount the 40W or 50W ERT module on a register. One of these kits
can be ordered for each ERT module. These kits come with a choice of three band clamp sizes. To select
the correct size, see Water ERT Ordering Guide (PUB-0063-001). The contents of this kit are illustrated in
Appendix B. NOTE: There is an additional charge for this kit.
To order the above kits, see the Water ERT Ordering Guide
(PUB-0063-001).
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 10
1–7
1.7Tools and Materials You Must Supply
The tools and material required depend on whether you are installing a direct-mount ERT module or a remotemount ERT module; and if it is remote, the way it is mounted (pipe or flat surface). You must supply some or
all of the tools and material listed in Tables 1–2 and 1-3 below. Also, If you remove and replace registers, you
might need tools specified by register manufacturer.
NOTE: For remote-mount installations, customer-supplied cable is required (Badger supplies 3 feet
to 100 feet, typically 25 feet); cable length should not exceed 300 feet (Badger 500 feet). Itron recommends 19-26 gauge, pre-bonded or solid conductor wire with a maximum diameter of .082" (individual
wire with insulation).
Table 1-2. Suggested Tool List
Tool or Material Required
Klein model D234-6C pliers, 3M ScotchLok® Model E-9C
Cartridge Tool, or similar tool for crimping wire connectors
Side-cutting pliers for cutting wires, remote cables, and cable
ties (NOTE: Klien model D234-6C pliers satisfy this requirement).
Torx® screwdriver, size T-10 security head, for the RTR
mounting setscrew (Badger only)
Torx screwdriver, size T-15 for the screws that attach ERT modules
to integral RTRs and Remote Mounting Brackets
ReadOne® Pro unit for programming and checking ERT modules
Medium flat-blade screwdriver for band clamps
Medium flat-blade, for the screws that attach adapter plates to pipe
brackets and the screws that attach remote mounting brackets to
adapter plates
Required for
Direct-Mount
or Integral
ERT Modules
XX
X
Required for Remote ERT Modules
Mounted on
Pipe
Mounted on Wood
or Sheet Metal
X
X
X
XXX
X
XX
X
X
X
X
X
Cable ties for securing remote cables to pipes or other supports
Standard or long-nose pliers for pulling cable ties tight
1/4-inch nut driver other tool for seating tamper seals
Medium Phillips screwdriver for the screws that attach remote
mounting brackets to wood or sheet-metal surfaces
1/16-inch awl for removing tamper seals
Wire strippers for removing insulation from cables and wires
Installing 40W and 50W ERT Modules
X
X
X
X
X
X
X
XXX
X
XX
Page 11
Table 1-3. Screw Anchors for Masonry Surfaces
1-8
Description
Plastic-Lipped Anchor
Lead-Lipped Anchor
Solid Masonry Anchor
All Purpose Masonry
Anchor
Length
0.875
1.00 inch
1.375 inch
Hole Size
3/16 inch drill
5/16 drill
5/16 drill x 5/8 inch deep
Flange or Flush Mount
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 12
2-1
SECTION 2. INSTALLING THE BADGER DIRECT-MOUNT
Check the part number on the label to make sure the ERT module matches the meter (reference Table
1-1).
UP
Always install an ERT module right side up, as indicated by the on the label.
Make sure you have a Badger register with a direct-mount bracket (as shown in Section 1).
CAUTION: If an ERT module is dropped from a height of 3 feet or more, there may be damage to the circuit
board. DO NOT install the ERT module.
NOTE
The register may or may not be mounted on the meter when performing the following steps.
2-1
Obtain an ERT module for the Badger
register. ERT modules have three
wires:
one wire with green insulation
one wire with red insulation
one wire with black insulation
2-2
Connect the black wire from the register to the
black wire from the ERT module with a gel connector, as described in Appendix A of this manual. Do
the same with the red wire. The green wire is not
used.
01547
NOTE: Fold the unused green wire
down into the ERT module housing.
Installing 40W and 50W ERT Modules
01547a
Page 13
01547b
2-2
2-3
Push the gel connectors down into
the ERT module housing
here.
2-4
Place the
ERT module in the slot of the
bracket.
The
edge of the ERT module housing
should be against the ribbed side in
the slot.
NOTE: A gasket is not required.
Obtain four Torx-head
ERT module mounting screws.
2-5
Install the mounting screws as
shown. Hand tighten each screw.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 14
2-3
01079
2-6
If you have not already done so, connect the register to the water meter
and fully tighten the
mounting screw as directed by Badger Meter.
NOTE
The register can be installed on the meter in four
different positions with respect to the direction of
water flow (refer to the directions that come with the
meter or register).
If the standard Torx screw is used
(as shown), a wire seal is not necessary.
2-7
If the optional slotted and drilled RTR screw is used,
install a wire seal through the drilled screw from here to here,
or as specified by utility policy.
To complete the installation:
Program and check the ERT module as described in
ReadOne Pro® Programming Guide (TDC-0027-XXX).
01080
Installing 40W and 50W ERT Modules
Page 15
SECTION 3. INSTALLING THE AMCO (ABB) SCANCODER, InVISION, OR
DIGITAL DIRECT-MOUNT
Check the part number on the label to make sure the ERT module matches the meter
(reference Table 1-1).
UP
Always install an ERT module right side up, as indicated by the on the label.
CAUTION: If an ERT module is dropped from a height of 3 feet or more, there may
be damage to the circuit board. DO NOT install the ERT module.
NOTE: The direct-mount bracket must be ordered from AMCO.
Direct-mount
bracket
3-1
01545F
AMCO Scancoder/Digital or
InVISION with a direct-mount
bracket.
completely out of its location
and separate the
ERT module mounting bracket
meter register collar.
NOTE
The register may or may not be mounted on the
meter when performing the following steps.
3-1
Push this
hollow pin
from the
01535
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 16
3-2
3-2
Obtain the correct ERT module for
use with the InVISION or Scancoder
register.
Obtain a 40W or 50W AMCO Digital
ERT module if connecting to a
Digital register.
01547z
00219
3-3
Strip 1/2-inch of insulation from
the end of the black, red and
green wires.
3-4
Place the ERT module mounting
bracket on the work surface with
its inside up.
01551Z
Installing 40W and 50W ERT Modules
Page 17
01557
3-3
3-5
Place the ERT module on the mounting bracket.
NOTE: A gasket is not required.
00983
3-6
Bring the red, black and green ERT module
wires out the wire exit hole in the ERT module
mounting bracket.
01722
3-7
Obtain four Torx-head ERT module mounting screws.
These screws are shipped in the same box with
AMCO Scancoder ERTs, and in a separate box for
AMCO Digital ERTs. The screws are shown here
approximately actual size.
3-8
Install all four ERT module mounting screws
as shown. Hand tighten each screw.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 18
3-4
01541
Install the green wire under this register screw head.
Tighten the screw fully.
3-9
Install the black wire under this
register screw head. Tighten the
screw fully.
Install the red wire under this
register screw head. Tighten the
screw fully.
IMPORTANT
Be sure to install the wires around the
screws in a clockwise direction, as
shown. If you don't, the wires may partially or completely come out from under
the screw heads as you tighten them.
Also, make sure no insulation is compressed under the screw head, or the
wire might not make good contact.
Install the ERT module and mounting
bracket on the
meter register adapter collar.
01558x
3-10
01542
Installing 40W and 50W ERT Modules
Page 19
3-11
Replace this hollow pin
where you removed it from in
step 3-1
3-5
01535
The meter and ERT module
assembly should now look like this.
To complete the installation:
Program and check the ERT
module as described in
ReadOne Pro® Programming
Guide (TDC-0027-XXX).
See programming Caution on
01546F
page 1-2.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 20
4-1
SECTION 4. INSTALLING THE SCHLUMBERGER ARB V OR PROREAD
REGISTER-MOUNT
Check the part number on the label to make sure the ERT module matches the meter (reference
Table 1-1).
Always install an ERT module right side up, as indicated by the on the label.
CAUTION: If an ERT module is dropped from a height of 3 feet or more, there may be damage to
the circuit board. DO NOT install the ERT module.
NOTE: Schlumberger's ProRead register must be programmed with a Schlumberger
ProRead Programmer as 3-wire to work properly with the ERT. Schlumberger ARB V registers
are not programmable.
01342z
UP
4-1
Schlumberger ARB V Register
(ProRead is similar)
Pull the bottom edge of the
wire terminal enclosure cover
out and down as shown .
01547z
Installing 40W and 50W ERT Modules
01672
4-2
Obtain a 40W or 50W Schlumberger
ARB V ERT module if connecting to an
ARB V register.
Obtain a 40W or 50W Schlumberger
ProRead ERT module if connecting to
a ProRead register.
Page 21
4-4
Connect the cable wires from the
ERT to the register screw termi-
nals as shown at right.
4-2
4-3
Strip 1/2-inch of insulation from end
of black, green and red wires on
ERT.
Connect the black cable wire to
this screw.
Connect the green cable wire to
this screw.
Connect the red cable wire to
this screw.
IMPORTANT
Be sure to install the wires around
the screws in a clockwise direction, as shown. If you don't, the
wires may partially or completely
come out from under the screw
heads as you tighten them. Also,
make sure no insulation is compressed under the screw head,
or the wire might not make good
contact.
01681F
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 22
4-3
4-5
Put the wire terminal enclosure cover
back on the register.
When you have finished, the register
and wires should look like this.
01681x
01551
Installing 40W and 50W ERT Modules
4-6
Place the ERT module mounting
bracket on the work surface with its
inside up.
Page 23
4-7
Place the ERT module on the
mounting bracket as shown, with
the wires in the remote mounting
bracket cable exit notch..
4-4
4-8
The ERT module and mounting
bracket should look like this.
01552
01014
4-9
Make sure the register wires are still
positioned in the exit notch.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 24
4-5
4-10
Get four Torx-head mounting screws
from the bulk supply. The screws
are shown at right approximately
actual size.
00983
01016
4-11
Install the Torx-head mounting screws
here.
Hand tighten each screw.
NOTE
Refer to Section 7 for instructions on how to install
the ERT module to the register.
Installing 40W and 50W ERT Modules
Page 25
5-1
SECTION 5. INSTALLING THE SENSUS ECR OR ICE REGISTER MOUNT
Check the part number on the label to make sure the ERT module matches the meter (reference Table
1-1). Always install an ERT module right side up, as indicated by the “UP” symbol on the label. CAUTION:
If an ERT module is dropped from a height of 3 feet or more, there may be damage to the circuit board.
DO NOT install the ERT module.
NOTE The register may or may not be mounted
on the meter when performing the following steps.
01547x
Sensus ECR register
Invensys ICE register
01547
5-1
To remove the cable entrance cover
from the meter register, turn it counterclockwise approximately 1/4 turn.
01547y
5-2
Obtain a 40W or 50W Sensus ECR/
ICE ERT.
5-3
Strip 1/2-inch of insulation from the
end of the black, green and red wires
on ERT.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 26
5-2
5-4
Install the black wire from the ERT under the
register screw head marked "B"
on the top of the register. Tighten the screw fully.
Install the red wire under the register
screw head marked "R"
on the top of the register. Tighten the screw fully.
Install the green wire under the register
screw head marked "G"
on the top of the register. Tighten the screw fully.
01548x
IMPORTANT
Be sure to install the wires around the screws in a
clockwise direction, as shown. If you don't, the
wires may partially or completely come out from
under the screw heads as you tighten them. Also,
make sure no insulation is compressed under the
screw head, or the wire might not make good
contact.
01558x
5-5
To reinstall the cable bracket on the
meter register, place it over the
wires, push down and turn clockwise until it lines up as shown.
01549x
Installing 40W and 50W ERT Modules
Page 27
5-6
Place the ERT module mounting
bracket on the work surface with its
inside up.
5-3
01551
Place the ERT module on the
mounting bracket the way shown
here, with the
in the remote mounting bracket
cable exit notch.
5-7
wires
01552x
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 28
5-4
5-8
The ERT module and mounting
bracket should look like this.
01014
01015
5-9
Make sure the register wires are still
in the mounting bracket exit notch.
Installing 40W and 50W ERT Modules
Page 29
5-10
Get four Torx-head mounting
screws
from the bulk supply. The screws
are shown approximately actual
size.
5-5
5-11
Install the Torx-head screws
here.
Hand tighten every screw.
NOTE
Refer to Section 7 for instructions on how to install the ERT
module to the register.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 30
6-1
SECTION 6. INSTALLING A REMOTE MOUNT
Check the part number on the label to make sure the ERT module matches the meter (reference Table
1-1).
Always install an ERT module right side up, as indicated by the on the label.
CAUTION: If an ERT module is dropped from a height of 3 feet or more, there might be damage to the
circuit board. Do not install the ERT module.
NOTE: All 40W & 50W ERT modules can be remote mounted above grade outside.
Get a supply of 19-26 gauge, pre-bonded or solid conductor wire with a maximum diameter of .082" (individual
wire with insulation). Note the Badger RTR register and the ADE register come with 3 feet to 100 feet of cable
(typically 25 feet). All other cable is to be supplied by the customer. Total cable length should not exceed
300 feet (500 feet for Badger).
INSTALLATION TIP: Some installers prefer to first run the wire from the water meter to the point where the
ERT will be installed and then connect the wire to the register, and lastly connect the other end of the wire to
the ERT. Any order is acceptable, and this is simply installer preference. If you use existing wire, do a
continuity check first.
NOTE: If customer-supplied wire is not color coded red, green, and black, care must be taken that each of
the 3 individually colored wires is installed correctly. For example, if customer supplied wire is pink, gray and
yellow, and the installer connects at the register the pink wire to the register's red (R), the gray wire to the
register's black (B), and the yellow wire to the register's green (G), then the installer must connect the other
end of those wires to the ERT as follows:
• Pink wire to ERT red wire
• Gray wire to ERT black wire
• Yellow wire to ERT green wire.
UP
The register may or may not be mounted on the meter
when performing the following steps.
Installing 40W and 50W ERT Modules
NOTE
6-1
Obtain adequate supply of wire (installer supplied).
Using a wire stripper, remove about
3" of the outer insulation from the
wire.
Strip 1/2-inch of insulation from each
of the three color coded wires.
Page 31
TO CONNECT TO AMCO (ABB) DIGITAL, InVISION, OR SCANCODER
REGISTER
6-2
Remove the terminal cover from the
register.
Connect the red wire to the terminal
labeled “R”.
Connect the green wire to the
terminal labeled “G”.
Connect the black wire to the
terminal labeled “B”.
6-2
See programming CAUTION on page 1-2
TO CONNECT TO BADGER RTR AND ADE REGISTERS:
6-3
There is no need to attach wire,
since it is already factory
installed and supplied with the
Badger RTR and ADE registers.
If more cable is needed, use gel
connectors, as described in
Appendix A. Do not exceed 500
01090
feet in total length.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 32
6-3
TO CONNECT TO HERSEY TRANSLATOR REGISTER:
6-4
Remove the screw terminal
cover from the register. Install
the red wire under
this screw head.
Tighten the screw fully.
Install the green wire
under this screw head.
Tighten the
screw fully.
Install the black wire under
this screw head.
Tighten the screw fully.
Install the screw terminal cover.
IMPORTANT
Be sure to install the wires around the screws in a
clockwise direction, as shown. If you don’t, the wires
may partially or completely come out from under the
screw heads as you tighten them. Also, make sure
no insulation is compressed under the screw head,
or the wire might not make good contact.
6-5
To assemble the ER pickup assembly follow the
instructions furnished with the meter register.
Refer to section 6.14 to connect the cable to the
ERT module.
Installing 40W and 50W ERT Modules
01873
Page 33
TO CONNECT TO SCHLUMBERGER ARB V OR PROREAD REGISTERS:
6-6
Remove the screw terminal cover.
Install the black wire under
this screw head.
Tighten the screw fully.
Install the green wire under
this screw head.
Tighten the screw fully.
Install the red wire under
this screw head.
Tighten the screw fully.
6-4
Install the screw terminal cover.
TO CONNECT TO SENSUS ECR OR ICE REGISTERS:
6-7
Remove the screw terminal cover.
Install the black wire under
this screw head.
Tighten the screw fully.
Install the green wire under
this screw head.
Tighten the screw fully.
Install the red wire under
this screw head.
Tighten the screw fully.
IMPORTANT
Be sure to install the wires around the screws in a clockwise
direction, as shown. If you don’t, the wires may partially or
completely come out from under the screw heads as you
tighten them. Also, make sure no insulation is compressed
under the screw head, or the wire might not make good
contact.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 34
6-5
TO CONNECT THE ERT MODULE TO THE METER REGISTER USING
GELCAP CONNECTORS:
6-8
G
B
R
To connect A 40W or 50W ERT
module to the meter register (other
than Badger), connect the wires as
follows:
• Black to black
• Green to green
• Red to red
NOTE: For instructions on how to
connect gelcap connectors, see
Appendix A.
6-9
B
Bare
01549XY
Installing 40W and 50W ERT Modules
G
To connect a 40W or 50W ERT module to a Badger register with a blackinsulated cable, connect as follows:
• Red to red
R
Black
• Black to black
• Green to bare wire
NOTE: For instructions on how to
connect gelcap connectors, see
Appendix A.
This configuration does
cut cable feature (Badger register
equipped with a brown-insulated cable
does support cut cable).
not support the
Page 35
G
6-6
6-10
To connect a 40W or 50W ERT module
to a Badger register with a brown-insulated cable, connect as follows:
Bare
B
Brown
R
• Red to red
• Green to green
• Black to black
• Fold the unused bare wire backward
along the brown cable, as shown.
This configuration supports the cut cable
feature (Badger register equipped with a
black-insulated cable does not support
cut cable).
NOTE: The 40W must have 3 wires to
support the cut cable feature.
6-11
To connect a 40W or 50W ERT
module to a Hersey ER register
R
connect as follows:
R
Bare
B
B
G
Black
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
• Red to black
• Bare to green
• Black to red
NOTE: For instructions on how to
connect gelcap connectors, see
Appendix A.
Page 36
6-7
Wiring Instructionsfor 6-11:
1. Cut black connector off the end of pulser assembly
about 1” from end. (See Picture)
2. Install the white cable tie about 2” from the end of the
pulser assembly that was just cut and properly tighten.
3. Remove about 1 1/2 inches of the cables outer jacket
and separate the 3 wires.
4. Place the Black wire from the ERT and the Red wire
from the pulser assembly into a gel connector and
properly crimp down on the connector. See Appendix A.
5. Place the Red wire from the ERT and the Black wire
from the pulser assembly into a second gel connector
and properly crimp down on the connector.
6. Place the Green wire from the ERT and the Bare wire
from the pulser assembly (remember to tightly twist bare
wire) into a third gel connector and properly crimp down
on the connector.
01874
Remove
Push the connectors and ERT
module wires down into the ERT
module housing.
Installing 40W and 50W ERT Modules
6-12
01549
Page 37
01551
6-13
Place the ERT module mounting
bracket on the work surface with
its inside up.
6-14
Place the ERT module on the
mounting bracket as shown, with
the cable routed through the exit
notch.
6-15
The ERT module and mounting
bracket should now look like this.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
01552F
01014G
Page 38
01015
6-8
6-16
Make sure the register cable is still in
the mounting bracket cable exit notch.
6-17
Get four Torx-head ERT module
mounting screws from the bulk
supply. The screws are shown
approximately actual size.
00983
6-18
Install the Torx-head ERT module
mounting screws where shown.
Hand tighten every screw.
01016
Installing 40W and 50W ERT Modules
Page 39
6-9
6-19
Drill three pilot holes in the
mounting surface the proper
size for the mounting
screws, as shown.
CAUTION
Make sure that you do not
damage anything on the
other side of the surface
you are going to mount
the remote mounting
bracket on when you drill
the holes and install the
screws.
IMPORTANT
The holes for the bottom
two screws must be on a
horizontal line.
00498
1-21/32"
3-3/8"
DRILLING TEMPLATE--ACTUAL SIZE
If you have several installations, you can make a durable
template as follows:
Drill a hole through the lug slot of a mounting bracket,
where indicated, to mark the position of that screw. Keep
this permanent template for future use.
NOTE
If you do not use the mounting screws furnished with the
ERT module, be sure to use
screws that have the same
size head as those furnished
with the ERT module.
INSTALLATION TIP
00222F
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 40
6-20
Get three mounting screws from
the configuration kit.
The screws are shown approxi-
mately actual size.
6-21
Screw the top mounting screw part
way into the mounting surface.
6-10
00499
01022
01022
6-22
Continue to drive the screw into the
mounting surface until the
back side of the
mounting lug recess on the ERT
module remote mounting bracket
will just barely slide under the
screw head.
01015
Installing 40W and 50W ERT Modules
Page 41
6-11
6-23
Push the ERT module upward until
the screw head is all the way into the
mounting lug recess.
01023
01020F
6-24
Install and fully tighten these two
mounting screws.
6-25
Get two new tamper seals
from the 40W/50W Configuration
Kit.
01026
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 42
01359F
6-12
6-26
Place a new
tamper seal
over each of these
mounting screws.
Push both tamper seals all the way
1/4-inch nut driver
Installing 40W and 50W ERT Modules
6-27
into place with a
or similar tool.
01360F
Page 43
6-13
6-28
When a tamper seal is fully seated,
top of the tamper seal
is about 3/32-inch below the
top of the screw recess.
the
01029F
6-29
After the plastic tamper seals have been
installed, the ERT module should look
like this.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
01352
ERT module on wood or sheet metal surface.
Page 44
SECTION 7. PIPE MOUNTS (AND REGISTER MOUNTS REQUIRING A
BAND CLAMP)
7-1
Always install an ERT module right side up, as indicated by the on the label.
UP
NOTE: Use this section to install an ERT module on a Schlumberger or Sensus
register.
7-1
Get a bracket
and a band clamp
from the pipe mount/
register mount
installation kit.
00864x
00775x
7-2
Loosen the
band-clamp screw
until the
end of the band
comes loose from the
screw assembly.
00867
7-3
Push the
end of the band through
this hole in the
bracket.
00787
Installing 40W and 50W ERT Modules
Page 45
7-2
7-4
Place the band clamp around the pipe on which you want
to mount the bracket. Push the
end of the band through
this hole in the band clamp.
00788
If mounting to a register, install a 4-1/2-inch band clamp
around the Schlumberger or Sensus register.
7-5
Push the
end of the band
clamp into the
entrance to
the screw
assembly.
00789
00460
7-6
Start tightening the
band clamp screw.
00790
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 46
00791
7-3
7-7
When the end of the band gets about
this far
out of this side of the screw assembly,
push it through
this hole
in the pipe bracket.
Then tighten the band-clamp screw three or
four more turns to make sure the end of the
band does not pop back out on this side of
the pipe bracket.
00792
7-8
Position the pipe bracket where you want it
on the pipe.
Position the band clamp as shown. Then
fully tighten the band clamp screw.
When the band clamp screw is fully
tightened, the band clamp and
bracket should look like this.
00865
Installing 40W and 50W ERT Modules
Page 47
7-4
7-9
Place an
adapter plate on the bracket.
This adapter-plate screw boss
goes into
this bracket recess.
This adapter-plate screw boss
goes into
this bracket recess.
00869
00868
7-10
When the adapter plate is properly positioned on the
pipe bracket, it looks like this.
7-11
Obtain two adapter-plate mounting screws
(shown here actual size) from the pipe
mount/register mount Installation kit.
00779
7-12
00797
Install the adapter-plate mounting screws in
these holes.
Hand tighten both screws.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 48
7-13
Install the two
remote mounting screws
to attach the ERT module to the
adapter plate.
7-5
01353
01354
7-15
Installing 40W and 50W ERT Modules
Install two plastic tamper seals as
described in Steps 6-21 through 6-24.
7-14
The ERT module installation should
now look like this.
Page 49
A-1
APPENDIX A. CONNECTING CABLE WIRES WITH GEL
CONNECTORS
A-1
Push the wires that are to be connected together as far as possible
into the connector.
00653
CAUTION
Do not strip any insulation from
the ends of the wires before you
push them into the connector.
00984
00985
00978
A-2
Place the connector (with wires) into
the jaws of the crimping tool.
A-3
Crimp the connector by squeezing
the handles until the connector looks
like this. Continue to apply pressure
for three seconds.
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 50
00654
A-2
00664
A-4
If using a 3M Scotchlok Model E-9C Cartridge Tool, push
the ends of the wires to be connected into the connector at
the end of the crimping tool, as shown.
Then squeeze the crimping tool handle until it pushes the
connector (now crimped) out of the tool when you release
the handle.
00659x
A connector is crimped properly if the
top of the movable, yellow center part
is flush with the
top of the connector body.
00665
CAUTION
Crimping the connectors sometimes squeezes some
sealant out of them. The sealant protects the inside
of the connector against insects, moisture, and other
contaminants.
The sealant may cause minimal eye and skin irritation. Avoid eye contact. Avoid prolonged or repeated skin contact.
Installing 40W and 50W ERT Modules
Page 51
B-1
APPENDIX B. ITRON INSTALLATION KITS
Configuration Kit (part number CFG-0067-001)
Remote Mounting Bracket
3 Mounting Screws
2 Plastic Tamper Seals
3 Gel Connectors
2 Cable Ties
01787
NOTE: Configuration kits are shipped in bulk, with 30 kits per box.
Refer to Water ERT Ordering
Guide (PUB-0063-001) for part
numbers of all components.
Specifications for the installation kit
screws used to attach 40W/50W
ABB Scancoder ERT modules to
wood, sheet metal, or masonry
surfaces are given at right. The
screws are shown approximately
actual size.
10-12 x 1 1/2 Phillips Pan Head Tapping Screw, Corrosion
Resistant Steel
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 52
Remote Mounting Bracket
4 Remote Mounting
Bracket Screws
3 Mounting Screws
2 Plastic Tamper Seals
3 Gel Connectors
2 Cable Ties
B-2
Configuration Kit (part number CFG-0067-002)
01788
NOTE: Configuration kits are shipped in bulk, with 30 kits per box.
Refer to Water ERT Ordering Guide (PUB-0063-001) for part numbers of all
components.
Specifications for the screws used to attach remote mounting brackets to wood or
sheet metal surfaces are given at right. The screws are shipped in bulk. The
screws are shown here approximately actual size.
10-12 x 1 1/2 Phillips Pan Head Tapping Screw, Corrosion
Resistant Steel
Installing 40W and 50W ERT Modules
Page 53
B-3
40W/50W Pipe Mount and Register Mount Installation Kit
Adapter
Plate
00775
Two screws for
attaching an ERT
module to the
adapter plate
Pipe Bracket
Band Clamp for attaching
the pipe bracket to a pipe
or
for installing an ERT module to
a Schlumberger or Sensus
register (see Section 7)
Two screws for
attaching the adapter
plate to the pipe bracket
Specifications for the screws supplied in the Pipe/Register Mount Installation Kit are
given below. The screws are shown approximately actual size.
For Mounting Adapter Plates on Pipe BracketsFor Mounting 40W/50W ABB Scancoder
ERT Modules on Adapter Plates
8-16 x 1/2 Type AB slotted pan head
tapping screw, corrosion resistant steel
8-16 x 1 Type AB slotted pan head tapping
screw, corrosion resistant steel
Installing 40W and 50W ERT Modules PUB-0126-001 4/04
Page 54
R-1
REVISION HISTORY
(PUB-0126-001)
REV
A45015 Initial Release
A145701 Added installation instructions for the 50W ERT
CCO
Description of change
DATE
1-4-01
APPROVALS
Engineering
Marketing
Engineering
Marketing
Tim Muotka
1-4-01
Janet Penz
1-4-01
A2 Added Hersey Translator Register
A3 Added programming Caution.
47127
47890
10-05-02
10-22-02
9-15-03
9-15-03
Engineering
Tim Muotka
Marketing
Janet Penz
Engineering
Joe Fritz
Marketing
Allen Rogers
Installing 40W and 50W ERT Modules
Page 55
REVISION HISTORY
(PUB-0126-001)
R-2
REV
CCO
Description of change
A4 47998 Added Badger ADE.
A548088Added AMCO InVISION and Invensys ICE registers.
DATE
10-23-03
10-22-03
12-17-03
12-10-03
APPROVALS
Engineering
Marketing
Engineering
Tim Muotka
Marketing
Allen Rogers
Joe Fritz
Allen Rogers
B
48449
Added Hersey ER registers.
5-4-04
5-4-04
Engineering
Tim Muotka
Marketing
Allen Rogers
Engineering
Marketing
Installing 40W and 50W ERT Modules PUB-0126-001 4/04