Itron CENGPRS1 Product Brochure

ITRON CENTRON® GPRS SMARTMETER
The combination of Itron’s CENTRON® Meter with the GPRS
SmartMeter Module from SmartSynch® introduces a powerful residential
communication solution for utilities. SmartSynch’s Transaction
Management System (TMS™) manages all meters integrated with the
SmartMeter module including the CENTRON GPRS SmartMeter. The
integrated CENTRON GPRS SmartMeter utilizes ANSI communication
standards to retrieve data and events for all the ANSI C12.19-1997 tables
Key Functions and Features
Flexible Two-Way Data Retrieval
Scheduled and On-Demand Reads
Automated Interval Read Retrieval
Real-Time Interval Reads
Automated Register, Self-Read and TOU Retrieval
Demand Resets
Real-Time Meter Event and Alarm Retrieval
Real-Time Power Outage and Power Restoration Alarms
Service Diagnostics and Tamper Detection
Tilt Detection
Meter Clock Synchronization
SmartMeter Display Status
Automated Meter Registration
Secure and Encrypted Data Transmissions
Over-The-Air SmartMeter Module Firmware Upgrade
Supported Meter Forms
Class 20: 3S, 4S
Class 100: 1S
Class 200: 2S, 12S, 25S
Class 320: 2S
Hardware Components
Radio Control Module Board (RCM)
Capacitor Storage Bank (CSB)
GSM Modem (Siemens MC56)
Internal Antenna
Tilt Detector
Temperature Sensor
Operating Ranges
Temperature
Operating: [-40°C, +85°C]
Transmission (wireless): [-40°C, +80°C]
Humidity
0% to 95% non-condensing
Accuracy
Meets ANSI 12.20 for accuracy class 0.5%
Regulatory and Industry Specifications
FCC Part 15 Class B
FCC Part 90 and FCC Part 1 (MPE)
ANSI C37.90.1 - 1989: (SWC)
ANSI C12.20 (Class 0.5) – 1998
PTCRB approval (in process)
SmartSynch, Inc.
1-888-362-1780
www.smartsynch.com
ITRON CENTRON® GPRS SMARTMETER
Functions and Features
Flexible Two-way DaTa ReTRieval anD ScheDuleD DaTa collecTion
Users can execute all appropriate TMS functionality using user configurable SmartMeter controlled schedules and TMS controlled schedules and as well as on an on-demand basis.
auTomaTeD inTeRval DaTa/eneRgy uSage ReTRieval
The CENTRON GPRS SmartMeter module retrieves and transmits interval data for 1 unique energy value for intervals as small
as 5 minutes. Recorded events and exceptions with each interval are also transmitted to the TMS, which interprets them and
logs appropriate messages (e.g. time adjustments).
Real-Time inTeRval ReaDS
Real-time interval data acquisition enables utilities to implement Load Curtailment and Real Time Pricing (RTP) programs. With this functionality, the user can configure the SmartMeter module to transmit load profile data as often as every 15 minutes at interval completion.
auTomaTeD RegiSTeR, SelF-ReaD anD Tou ReTRieval
The CENTRON GPRS SmartMeter module is configured by the TMS to read and transmit all or a subset of enabled registers including totals, self-reads, maximum demand and time-of-use values.
DemanD ReSeTS
The CENTRON GPRS SmartMeter module executes Demand Resets using one of three methods: SmartModule initiated schedules, TMS initiated schedules or TMS on-demand requests.
Real-Time meTeR evenT anD alaRm ReTRieval
The CENTRON GPRS SmartMeter provides automatic real-time alarm reporting of all events defined in the ANSI C12.19 standard including history and event codes, ANSI Standard status and Manufacturer status alarms. Additionally, alarms received by TMS can be automatically routed via e-mail to a specific user or group of users using the TMS Message Routing Interface.
Real-Time PoweR ouTage anD ReSToRaTion alaRmS
With built-in Ultra Capacitor energy storage, the CENTRON GPRS SmartMeter module will transmit a real time “last gasp” notification when detecting an AC power outage without requiring the use of less reliable batteries. The CENTRON GPRS SmartMeter also notifies the TMS when the AC power is restored and provides full configuration of these alarms based on user defined durations.
SeRvice DiagnoSTic anD TamPeR DeTecTion aleRTS
The CENTRON GPRS SmartMeter can report power service and wiring errors detected by the meter including reverse polar­ity, cross-phase and energy flow, phase voltage deviation, inactive phase current, phase angle displacement, and current waveform distortion. In addition, the SmartMeter can detect and report exceptions for the following tamper events: number of Demand Resets, Loss of AC power, and reported power outages.
The TMS configures a specific filter in the SmartMeter for each of these events enabling the transmission of a corresponding alert only after the event is repeated a minimum of times within a specific duration. The TMS can also configure the SmartMeter to reset the event counter when the alert message is transmitted.