Confidentiality Notice
The information contained herein is proprietary and confidential and provided subject to the condition that (i) it is held i n confidence except to the extent required otherwise by law and (ii) it is
used only for the purposes described herein. Any third party given access to this information is similarly bound in writing.
Compliance Statement
This device c omplies with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installati on. Operation is subj ect to
the following two conditions:
• This device may not c ause harmful interference.
• This device must accept any interference that may cause undesirable operation.
This device m ust be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to c omply with FCC RF exposure levels.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency ener gy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occ ur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which c an be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio or TV technician for help.
This equipment complies with policies RSS-210 and RSS-GEN of the Industry Canada rules.
Operation is subject to the followi ng two conditions:
• (1) this device may not cause interference, and
• (2) this device must accept any interference, including interferenc e that may cause
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
• (1) l'appareil ne doit pas produire de brouillage, et
• (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même
si le brouillage est susceptible d'en compromettre le fonctionnement.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a
type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce
potential radio interference to other users, the antenna type and its gain should be so chos en that
the equivalent isotropically radiated power ( e.i.r.p.) is not more than that necessary for successful
communication.
Trademark Notice
Itron is a registered trademark of Itron, Inc.
All other product names and logos in this docum entation ar e used for identification purposes only and m ay be trademarks or registered trademarks of their respective companies.
Warning To prevent ignition of flammable or combustible atmospheres, disconnect power
Conformément à la réglem entation d'Industrie Canada, le présent émetteur radi o peut
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour
l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectri que à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain
de sorte que l a puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité
nécessaire à l'établissement d'une communication satisfaisante.
before servicing.
Warning Follow these procedures to avoid injury to yourself or others:
•The lithium battery may cause a fire or chemical burn if it is not disposed of
properly.
•Do not recharge, disassemble, heat above 100° Celsius (212° Fahrenheit),
crush, expose to water, or incinerate the lithium battery. Fire, explosion, and
severe burn hazard.
• Keep the lithium battery away from children.
• Replace the lithium battery only with batteries meeting Itron specifications.
Warning ELECTROMAGNETIC COMPATIBILITY
Use only approved accessories with this equipment. Unapproved modifications or operation
beyond or in conflict with these instructions for use may void authorization by the authorities
to operate the equipment.
Warning This unit cannot be modified and is not repairable. Attempts to modify or repair
this device will void the warranty.
Proprietary and Confidential
TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide iii
Transportation Classification
The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When power ed, ERT modules are considered operating transmitters and receivers
and cannot be shipped by air. All product returns must be shipped by ground transportation to Itron.
Suggestions
If you have comments or suggestions on how we may improv e this documentation, send them to TechnicalCommunicationsManager@itron.com
If you have questions or comments about the software or hardware product, contact Itron Technical Support:
Contact
• Internet: www.itron.com
• E-mail: support@itron.com
• Phone: 800 635 8725
Proprietary and Confidential
TDC-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide iv
Proprietary and Confidential
TDC
Contents
Chapter 1 Before You Begin ........................................................................................ 1
Enabling 100W+ and 100WP+ ERT Module Security ........................................................................ 6
Battery Life .......................................................................................................................................... 6
100W/100W+ and 100WP/100WP+ ERT Module Transmission Modes ............................................ 7
Appendix D Troubleshooting .................................................................................... 46
Index ............................................................................................................................. 47
-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide vi
Proprietary and Confidential
TDC
Convention
Example
Chapter
Description
100WP/100WP+ ERT module, and connect the ERT modules to the
C HAPTER 1
B
efore You Begin
Document Conventions
Itron product part numbers are noted in
To install the ERT module (ERW-1300-XXX), do the following steps.
parentheses.
Hypertext links are in blue. See How The Document is Organized on page 1 for document structure information.
Note A Note indicates neutral or positive information that stresses or supplements important points of the
main text. A note supplies information that may apply only in special cases.
Caution A Caution advises users that failure to take or avoid a specified action could result in a loss of
data.
Warning A Warning advises users that failure to take or avoid a specified action could result in physical
harm to the user or the hardware.
Document Purpose
This document provides the installation instructions for the 100W/100W+ and 100WP/100WP+. Mounting
options for the 100W/100W+ and 100WP/100WP+ ERT module include rod mount, wall mount, through-lid
(remote antenna), and shelf-mount installation. For available model configuration, see 100W/100W+ and
100WP/100WP+ ERT Module Models on page 4.
An optional Itron Leak Sensor is available for all three configurations to provide leak monitoring capability.
100W/100W+ and 100WP/100WP+ ERT module configurations provide an easy interface to several register
types. The 20-inch cable variant allows meter manufacturers to mount the ERT module directly to their
respective meter registers before delivery to the installer.
Caution Installing an integrated 100W/100W+ and 100WP/100WP+ ERT module and meter register in a
water pit box reduces the ERT module's RF signal distance significantly. If read reliability is a problem,
install a remote antenna or select a new installation method.
How This Document is Organized
This document is organized into the following chapters:
1. Before You Begin Information about this publication.
2. About the 100W/100W+ and 100WP/100WP+ ERT
Module
3. Initializing, Connecting, and Programming the ERT
Module
-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 1
Overview of 100W/100W+ and 100WP/100WP+ ERT module
installation.
Instructions to initialize the 100W/100W+ ERT module, program the
water meter.
Proprietary and Confidential
Before You Begin
TDC
Chapter
Description
4. Installing the 100W/100W+ and 100WP/100WP+ ERT
Document Description
Itron Part Number
100 Series Modules and CENTRON Bridge Meter Tamper Reference Guide
5. Optional Direct Connect Remote Antenna Installation Instructions for installing the optional remote antenna.
Appendix A Using an Inline Connector Instructions for installing an inline connector.
Appendix B Using the Itron Splice Kit Instructions for installing the Itron Splice Kit.
Appendix C Optional Armor Cable Installation Instructions for installing the optional armor cable.
Appendix D Troubleshooting Troubleshooting 100W/100W+ and 100WP/100WP+ ERT module
operation.
Related Documents
TDC-1028-XXX
Field Deployment Manager Endpoint Tools Mobile Application Guide TDC-0934-XXX
Field Deployment Manager Field Representative's Guide TDC-0936-XXX
900 MHz Belt-Clip Radio User's Guide TDC-0889-XXX
TDC-0898-XXX
FC200 Series Getting Started Guide TDC-0598-XXX
Water ERT Module Ordering Guide PUB-0063-001
Water Meter Compatibility List PUB-0063-002
mlogonline™ Network Leak Monitoring System User Guide TDC-0792-XXX
Note XXX designates the document revision and is subject to change without
notice.
-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 2
Proprietary and Confidential
TDC
C HAPTER 2
A
bout the 100W/100W+ and 100WP/100WP+ ERT Module
The 100W/100W+ and 100WP/100WP+ ERT modules are high-power radio frequency automatic meter
reading (AMR) devices that attach to water registers to collect consumption usage and tamper data the ERT
module then transmits to a data collection device. The ERT module operates in both bubble-up mode and twoway mode.
The 100W/100W+ and 100WP/100WP+ ERT modules ship in factory mode. After installation and
programming, the ERT modules acquire and transmit meter register data. The ERT module transfers meter
data immediately if the unit is initialized or programmed with a handheld computer during installation (see
Initializing, Connecting, and Programming the ERT Module).
The 100W/100W+ and 100WP/100WP+ ERT modules support protocols for a variety of meter manufacturer's
registers. Refer to the Water Meter Compatibility List (PUB-0063-002), for the list of supported meters and
registers.
The 100W/100W+ and 100WP/100WP+ ERT modules are capable of reading 9-digit registers. The
100W/100W+ may be programmed to truncate up to three digits. Field Deployment Manager (FDM) provides
the programming tool to set the 100W/100W+ for your register's dial parameters.
100W/100W+ and 100WP/100WP+ ERT modules feature the following capabilities:
•Leak Detection and Reverse Flow Detection. The 100W/100W+ and 100WP/100WP+ ERT modules
feature robust features that provide Leak Detection and Reverse Flow Detection. For more information
about Leak Detection and Reverse Flow Detection, see the Itron white paper, Detecting Leaks and
Reverse Flow with 100W Series ERT Modules.
• (Optional) Leak Sensor or Remote Water Shut-off (SO).
• Itron Leak Sensors (LS) analyze water flow sound patterns to detect new, evolving, and preexisting
water leaks. LS analysis data is uploaded to mlogonline Network Leak Monitoring for data analysis.
Systems with optional LS devices access leak information through a utility-specific, secure
mlogonline portal.
-0909-006 100W/100W+ and 100WP/100WP+ Datalogging Water ERT Module Installation Guide 3
Proprietary and Confidential
Loading...
+ 20 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.