Itron 100GDLRN Users Manual

Natural Gas Solutions
100G Datalogging FN ERT Module Installation
Guide - Remote Mount
TDC-0824-003
Identification
Warning Follow these procedures to avoid injury to yourself or others:
The lithium battery may cause a fire or chemical burn if it is not disposed of properly. Do not recharge, disassemble, heat above 100º Celsius (212º Fahrenheit), crush, expose to
water, or incinerate the lithium battery. Fire, explosion, and severe burn hazard. Keep the lithium battery away from children. Replace the lithium battery only with batteries meeting Itron specifications. Any other battery
may cause a fire or explosion.
Warning Only authorized Itron personnel should attempt repairs on Itron equipment. Attempts to do so by others might void any maintenance contract with your company. Unauthorized service personnel might also be subject to shock hazard on some Itron equipment if removal of protective covers is attempted.
Warning To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing.
Warning Substitution of components may impair intrinsic safety.
100G Datalogging FN ERT Module Installation Guide - Remote Mount 01/10/2011 TDC-0824-003 100G Remote Mount ERT Module part numbers: ERG-5000-501, ERG-5000-502, ERG-5000-503 100G Datalogging Remote Mount ERT Module: ERG-5002-501, ERG-5002-502, ERG-5002-503, ERG-5002-505
100G Datalogging FN Remote Mount ERT Module: ERG-5003-501, ERG-5003-502, ERG-5003-503, ERG-5003-505 Copyright © 2009 - 2010 - 2011 Itron, Inc. All rights reserved. Confidentiality Notice The information contained herein is proprietary and confidential and is provided subject to the condition that (i) it i s held in confidence except to the extent required otherwise by law and (ii) is issued only for the purposes described herein. Any third party given access to this information is similarly bound in writing. Trademark Notice Itron is a registered trademark of Itron, Inc. All other product names and logos in this documentation are used for identification purposes only and may be trademarks or re gistered trademarks of their respective companies. Applicable Patents U.S. Patent Numbers: 4,614,945; 4,753,169; 4,768,903; 4,799,059; 4,867,700 Canadian Patent Numbers: 1,254,949; 1,267,936; 1,282,118
Compliance Statement This device complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two conditions:
This device may not cause harmful interference. This device must accept any interference that may cause undesirable operation.
This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels.
Compliance Statement This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Déclaration de conformité Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Transportation Classification
The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, the 100G Datalogging FN remote ERT module is considered an operating transmitter and receiver and cannot be shipped by air. All product returns must be shipped by ground transportation. Modifications and Repairs To ensure system performance, this device and antenna shall not be changed or modified without the expressed approval of Itron. Any unauthorized modification will void the user's authority to operate the equipment. Meter Installation/Removal In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of users requiring service to report the need for service to Itron.
Suggestions If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com If you have questions or comments about the software or hardware product, contact Itron Technical Support: Contact
Internet: www.itron.com
E-mail: support@itron.com
Phone: 1 877 487 6602
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount iii Proprietary and Confidential
Before You Begin .......................................................................................................... v
Contents
Document Purpose .............................................................................................................................. v
Chapter 1 100G Datalogging FN Remote ERT Module .............................................. 1
Transmission Modes ........................................................................................................................... 1
Specifications ...................................................................................................................................... 2
Related Documents .................................................................................................................. 2
100G Datalogging FN Remote ERT Module Meter Compatibility List ................................................ 3
Installation Prerequisites ..................................................................................................................... 5
Chapter 2 Mounting the 100G Datalogging FN Remote ERT Module ....................... 6
Installation Options .............................................................................................................................. 6
Mounting Screw Specifications ................................................................................................. 6
Mounting Installation Considerations .................................................................................................. 7
Mounting the Remote ERT Module on a Pipe .......................................................................... 8
Mounting the ERT Module on a Wall or Other Flat Vertical Surface ............................ 14
Chapter 3 Rotary Meter Installation .......................................................................... 16
Required Installation Materials Available from Itron .......................................................................... 17
Programming the Remote ERT Module for Dresser ROOTS® Rotary Meters .................................. 19
B3, LMMA & S3A CTR/TC Meter Drive Rates for Remote ERT Module Programming ................... 20
Installing the Remote ERT Module to the Elster American Meter RPM Series Rotary Meter .......... 21
Mounting the 100G Datalogging FN Remote Mount ERT Module .................................................... 27
Installing the Remote ERT Module to the Romet Electronically Compensated Meter (ECM2®) ...... 27
Connecting the Remote ERT Module to the Romet ECM2® Meter ................................................... 28
Romet ECM2® Mounting Requirement.............................................................................................. 28
Programming the 100G Datalogging FN Remote ERT Module ........................................................ 31
Chapter 4 Electronic Volume Corrector and Instrument Installation ..................... 33
Installation Prerequisites ................................................................................................................... 34
Installation Overview ......................................................................................................................... 34
Programming the Mercury Instrument ............................................................................................... 35
Code Settings.......................................................................................................................... 35
Wiring the ERT Module to the Instrument ......................................................................................... 36
Wiring Dual ERT Modules to a Mercury Instrument .......................................................................... 38
Wiring the Remote ERT Module to the Mercury TCI ........................................................................ 40
Connecting the 100G Datalogging FN Remote Mount ERT Module to the IMC/W2 or MC2 Cable . 43
Installing the ERT Module to the Dresser ROOTS® Micro Corrector (IMC/W2 or MC2) .................. 46
Programming the 100G Datalogging FN Remote ERT Module ........................................................ 50
Contents
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount iv Proprietary and Confidential
Chapter 5 Diaphragm Meter Installation ................................................................... 52
Tools and Materials Supplied By You ............................................................................................... 52
Materials Available from Itron ............................................................................................................ 53
Replacement Gaskets ............................................................................................................. 53
Installing the 100G Datalogging FN Remote ERT Module ............................................................... 54
Installing 100G Datalogging FN Remote ERT Module Encoders ..................................................... 55
Index Cover Installation Required Materials ........................................................................... 60
Programming the 100G Datalogging FN Remote ERT Module ........................................................ 64
Chapter 6 DATTUS Meter Installation ....................................................................... 66
Installation Prerequisites ................................................................................................................... 66
Programming the DATTUS Meter ..................................................................................................... 66
Installation Overview ............................................................................................................... 66
Installing the Remote ERT Module to Itron DATTUS Meters ....................................... 67
Mounting the 100G Datalogging FN Remote ERT Module .......................................... 70
Programming the 100G Datalogging FN Remote ERT Module ................................... 71
Chapter 7 Sensus Sonix Meter Installation .............................................................. 73
Programming the Sensus Sonix Meter ............................................................................................. 73
Adjusting the Pulse Output for Sonix 600 and 880 Meters ..................................................... 73
Installing the 100G Datalogging FN Remote ERT Module with Sensus Sonix Meters ..................... 74
Sensus Sonix2000 Pulse Output Wiring ................................................................................. 74
Direct Mounting the Remote ERT Module to the Sonix Meter ................................................ 75
Connecting the Remote ERT Module to a Sensus Sonix 600 or 880 Meter .......................... 76
Programming the 100G Datalogging FN Remote ERT Module .............................................. 77
Index ............................................................................................................................. 79
Before You Begin
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount v Proprietary and Confidential
The following documentation conventions are used:
Caution A Caution warns the user that failure to heed the information in the note could result in loss of data. Be sure to carefully read a Caution note and follow the advice/instructions.
Warning A Warning alerts you about potential physical harm to the user or hardware. It is critical that you pay strict attention to Warning notes, read the information carefully, and follow the advice/instructions.
Before You Begin
Tip A Note provides the user with extra hints to make a task easier to perform or a concept easier to understand.
Note A Note supplies generic information to the user. The user could ignore the information and continue a task without suffering any adverse consequences.
Document Purpose
This installation guide provides step-by-step instructions for installing the 100G Series remote gas ERT module on a wide variety of meters and instruments. This installation guide refers to the 100G series remote ERT module as the 100G Datalogging FN remote ERT module. Mechanical and electrical installation procedures are similar for all modules. 100G Datalogging FN remote ERT module compatible meters and instruments are listed in the 100G Datalogging FN Remote ERT Module Meter Compatibility List on page 3.
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 1 Proprietary and Confidential
Itron 100G series remote ERT modules are radio-frequency (RF) devices designed to transmit meter data to an
C H A P T E R 1
100G Datalogging FN ERT Module
RF meter reading device within transmission distance of the remote ERT module. The 100G remote gas ERT module was designed with a higher output power than earlier Itron remote gas ERT modules to achieve an increased RF transmission distance. The 100G series remote gas ERT modules have greater output power to meet Itron mobile and fixed network requirements. The first 100G remote gas ERT module offered high transmit power capability which increased operational efficiency and reduced infrastructure costs. The 100G Datalogging remote gas ERT module offers high transmit power with data logging capability (time-stamped hourly interval data) for both mobile and fixed network applications. Itron's 100G Datalogging Fixed Network (DLN) remote gas ERT module adds improved network performance through even higher transmit power, accomplished using increased antenna efficiency and more robust optimized messaging structures.
The 100G Datalogging FN remote ERT module features tilt-tamper and cut cable-tamper reporting and security seals to indicate physical tampering and minimize theft. Cut cable is reported when the cable is cut or disconnected from the meter, instrument, or endpoint. 100G Datalogging FN remote ERT module circuitry senses an electrical current break to report a cut cable tamper event.
Transmission Modes
The 100G Datalogging FN remote ERT module can be set to transmit in Fixed Network, Mobile and Handheld, or Hard to Read Mobile and Handheld Mode.
Fixed Network Mode. The 100G Datalogging FN remote gas ERT transmits a high-powered network
interval message (NIM) RF message every five minutes. Output power in this mode is 500 milliwatts or +27 dBm. Interspersed in the high power NIM, the 100G Datalogging FN remote ERT module transmits a medium power RF message at 10 milliwatts or +10 dBm; expected battery life is 20 years.
Mobile High Power Mode. The 100G series remote gas ERT transmits a high-powered RF message
every 60 seconds. Output power in this mode is 250 milliwatts or +24dbm; expected battery life is 20 years.
Mobile and Handheld Mode. The 100G series remote gas ERT transmits a medium-powered RF
message every 15 seconds. Output power in this mode is 10 milliwatts or +10dBm; expected battery life is 20 years.
(Optional) Hard to Read Mobile and Handheld Mode. The 100G series remote FN gas module
transmits a high-powered RF message every 30 seconds. Output power in this mode is 250 milliwatts or +24dBm; expected battery life decreases to 15 years in this mode. The Hard to Read Mobile and Handheld Mode should only be used for exceptionally hard-to-read applications (such as meters installed on roof tops or in sub-basements).
An FCC license is not required to read 100G series remote gas ERT modules.
100G Datalogging FN ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 2 Proprietary and Confidential
Specifications
Functional Specifications
Description
Power source
Two "A" cell lithium batteries
Tamper detection
Tilt tamper and cut cable tamper
FCC compliance
Part 15 certified
Industry Canada compliance
RSS-210 certified
Intrinsically safe per
UL Class I, Division 1, Groups C and D
Product identification
Numeric and bar-coded ERT module type and serial number
Construction materials
Gray polycarbonate housing and back plate with encapsulated electronics
Operational Specifications
Description
Operating temperatures
-40° to 158° F (-40° to +70° C)
Operating humidity
5 to 95 percent relative humidity
Program frequency
908 MHz
Transmit frequency
Spread spectrum 908 to 924 MHz ISM band
Data integrity
Verified in every data message
Document Title
Document Part Number
Gas Endpoint Meter Compatibility List
PUB-0117-002
Gas Endpoint Ordering Guide
PUB-0117-001
100G Datalogging Specification Sheet
Publication 100941SP-XX
Endpoint Link Programming Guide
TDC-0744*
Field Deployment Manager Endpoint Tools Mobile Application Guide
TDC-0934*
Field Deployment Manager Field Representative's Guide
TDC-0936*
The functional and operational specifications for the 100G Datalogging FN remote ERT module are listed below.
Related Documents
*The last three digits of the user and installation guides represent the document's revision level. The revision level is subject to change without notice.
100G Datalogging FN ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 3 Proprietary and Confidential
100G Datalogging FN Remote ERT Module Meter Compatibility
Meter
Model
Description
Class
Comments
ERT Module Type
ERT Module Part Number
Elster/American/ Canadian
10 Metric (10B)
Iron case
Residential
2.5' cable with encoder
100G Remote 100G Datalogging Remote 100G Datalogging FN Remote
ERG-5000-501 ERG-5002-501 ERG-5003-501
Sensus/Invensys
Sonix 12,16,25,57, 600,880,2000
Pulser Metric Cubic foot
Commercial
12" lead wires
100G Remote 100G Datalogging Remote 100G Datalogging FN Remote
ERG-5000-503 ERG-5002-503 ERG-5003-503
National/ Lancaster
All meters
Where direct mount is not compatible
Residential
2.5' cable with encoder
100G Remote 100G Datalogging Remote 100G Datalogging FN Remote
ERG-5000-501 ERG-5002-501 ERG-5003-501
Itron/Actaris Schlumberger/ Sprague
1A
Where direct mount is not compatible
Residential
2.5' cable with encoder
100G Remote 100G Datalogging Remote 100G Datalogging FN Remote
ERG-5000-501 ERG-5002-501 ERG-5003-501
Itron/Actaris/ Schlumberger/ Sprague
Metris 250
Straight Face meter
Residential
2.5' cable with encoder
100G Remote 100G Datalogging Remote 100G Datalogging FN Remote
ERG-5000-501 ERG-5002-501 ERG-5003-501
Itron/Actaris/ Schlumberger/ Sprague
305
#2 flat-face meter
2.5' cable with encoder
100G Remote 100G Datalogging Remote 100G Datalogging FN Remote
ERG-5000-501 ERG-5002-501 ERG-5003-501
Itron/Actaris/ Schlumberger/ Sprague
400
#3 flat-face meter
2.5' cable with encoder
100G Remote 100G Datalogging Remote 100G Datalogging FN Remote
ERG-5000-501 ERG-5002-501 ERG-5003-501
Itron/Actaris/ Schlumberger/ Sprague
675, 1000
Front mount index
Commercial
2.5' cable with encoder Also requires thicker gasket for magnet hub to clear index box. 1-hole gasket: FAB-0014-001 2-hole gasket: FAB-0014-002 4-hole gasket: FAB-0014-003
100G Remote 100G Datalogging Remote 100G Datalogging FN Remote
ERG-5000-501 ERG-5002-501 ERG-5003-501
Elster American
TC and STD CTR
American RPM series rotary meters including TC and non-TC.
Commercial
Meter must have a factory installed pulser with connector output. Purchase endpoint from Itron and correct cable interface from appropriate meter manufacturer.
100G Remote (12' lead wires) 100G Datalogging Remote (12" lead wires) 100G Datalogging FN Remote (12" lead wires)
ERG-5000-503 ERG-5002-503
ERG-5003-503
Romet
STD CTR 600 through 56000 TC 2000 through 23000
RM series
Commercial
Meter must have a factory installed pulser with connector output. Purchase endpoint from Itron and correct cable interface from appropriate meter manufacturer.
100G Remote (12' lead wires) 100G Datalogging Remote (12" lead wires) 100G Datalogging FN Remote (12" lead wires)
ERG-5000-503 ERG-5002-503
ERG-5003-503
List
This table lists meters compatible with the 100G Datalogging FN remote ERT module. Due to continuous research, product improvements, and enhancements Itron reserves the right to change this list without notice.
100G Datalogging FN ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 4 Proprietary and Confidential
Meter
Model
Description
Class
Comments
ERT Module Type
ERT Module Part Number
Romet
RM Series
ECM2 Electronically compensated meter
Commercial
Meter must have connector pin with factory-installed pulse output. Purchase endpoint from Itron and correct cable interface from Romet. ECM2 must be configured for 750ms "off­time" between pulses. The ECM2 must have firmware version J or later.
100G Datalogging Remote (12" lead wires)
100G Datalogging FN Remote (12" lead wires)
ERG-5002-503
ERG-5003-503
Dresser ROOTS®
B3/LMMA
Dresser ROOTS
®
rotary meters equipped with WeigandWire solid state pulsers
Commercial
Meter must have factory­installed pulser with connector output. Purchase endpoint from Itron and correct cable interface from Dresser. Dresser pulser must be version 17 or higher to be compatible.
100G Remote (12" lead wires) 100G Datalogging Remote (12" lead wires) 100G Datalogging FN Remote (12" lead wires)
ERG-5000-503
ERG-5002-503
ERG-5003-503
Dresser ROOTS®
IMC/W2 MC2
Dresser ROOTS
®
Micro Correctors
Commercial
Endpoint compatibile with IMC/W2 firmware version
1.93 or earlier. Pulse width must be set for 125ms. Pulse output must be at 100CF(CM) or higher.
100G Datalogging Remote (12” lead wires) 100G Datalogging FN Remote (12" lead wires)
ERG-5002-505
ERG-5003-505
Itron/Actaris
DATTUS fM2/fM3
Commercial
For all meter types, pulse width must be set to .050 seconds. Meter type 11M or smaller must have pulse weight minimum of 10 cubic feet or 1 cubic meter. Meter type 16M or greater must have pulse weight minimum of 100 cubic feet or 1 cubic meter.
100G Datalogging Remote (5' cable) 100G Datalogging FN Remote (5' cable)
ERG-5002-502
ERG-5003-502
Mercury Instruments
EC-AT Mini-P
Mini-AT Mini-Max
Pressure and temperature electronic volume correctors
Commercial
Correctors must have a Form A board; Form C is NOT supported. Item #056 Pulse Scaling Factor must be set to
2.0. Item #096 Cor Vol Display must be set at 1, 2, 3, or 4 blanks. endpoint does NOT support a setting of 0 blanks. Item #115 Output Pulse Code must be set at 1, 2, 3, or 4. endpoint does NOT support an Output Pulse Code of 0.
100G Remote (5'cable) 100G Datalogging Remote (5' cable) 100G Datalogging FN Remote (5' cable)
ERG-5000-502 ERG-5002-502
ERG-5003-502
Mercury Instruments
TCI
Temperature Compensating Index
Commercial
Correctors must have a Form A board, Form C is NOT supported. Item #56 Pulse Scaling Factor must be 2.0. Item #96 must be 7, 6, 5, or 4 digits (1, 2, 3, & 4 blanks). Endpoint does NOT support 8 digits (0 blanks). Item # 1014
set to the preset “Itron”
selection in the drop down menu. Compatible firmware versions on TCI are 1.06,
1.07, and 1.10.
100G Datalogging Remote (5’ cable)
100G Datalogging Remote (12” lead wires)
100G Datalogging FN Remote (5’ cable)
100G Datalogging FN Remote (12" lead wires)
5’: ERG-5002-502
12”:ERG-5002-503
ERG-5003-502
ERG-5003-503
100G Datalogging FN ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 5 Proprietary and Confidential
Installation Prerequisites
Note Reference the appropriate programming guide or specification sheet for correct software version (see Related Documents on page 2).
The following tools are required to install, program, and check the 100G Datalogging FN remote ERT module. Some specific tools may be required dependent on meter or instrument type.
Medium flat-blade screwdriver Small flat-blade screwdriver Medium Phillips screwdriver Hand pliers Side-cutting pliers 1/4-inch nut driver or similar blunt tool One-inch width putty knife Adjustable wrench 3M Scotchlock E-9Y crimping tool, 3M Scotchlock E-9C cartridge tool, or similar crimping tool All-weather electrical tape Size T-10 Torx screwdriver Itron programming device to program and check 100G Datalogging FN remote gas ERT module
installation and operation:
FC200SR handheld computer with Endpoint-Link or Endpoint-Link Pro software version 5.3 or higher or Field Deployment Manager (FDM) software version 1.1 or higher
or FC300 with SRead with Endpoint-Link or Endpoint Link Pro version 5.5 or higher or Field Deployment
Manager (FDM) software version 1.1 or higher or 900 MHz Belt Clip Radio with Endpoint-Link version 5.5 or higher or Field Deployment Manager (FDM)
software version 1.1 or higher and a customer-supplied laptop
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 6 Proprietary and Confidential
This chapter provides the instructions to mount the 100G Datalogging FN remote ERT module on a pipe or
Application
Itron Part Number
Description
To mount adapter plates on pipe brackets
575-9930-016
8-16 x 1/2-inch length, Type 8 slotted pan-head tapping screw - corrosion-resistant steel
To mount remote ERT modules on adapter plates
575-9930-032
8-16 x 1-inch Type 8, slotted pan-head tapping screw, corrosion-resistant steel
To mount remote ERT modules on sheet metal surfaces (to mount ERT modules to wood surfaces, a comparable wood screw is required)
SCR-0009-001
10-16 x 1 1/2-inch Type AB thread for sheet metal, Phillips pan-head tapping screw, corrosion-resistant steel
C H A P T E R 2
Mounting the 100G Datalogging FN Remote ERT Module
other flat vertical surface (wall).
Installation Options
Mount the 100G Datalogging FN remote ERT module using the Pipe Mount or Wall Mount (Flat Surface) procedure.
Pipe Mount. Pipe mounting is used in conjunction with the Remote Mount Kit (Itron part number CFG-
0005-003). The pipe mount option places the ERT module on a pipe near the meter or instrument (not on a wall surface). This option requires a meter manufacturer's cable to connect the ERT module to the meter or instrument.
Flat Vertical (Wall) Mount. Installation using the wall mount option places the ERT module on a wall or
other vertical surface. A cable connects the ERT module to the meter or instrument.
Mounting Screw Specifications
Mounting the 100G Datalogging FN Remote ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 7 Proprietary and Confidential
Mounting Installation Considerations
Caution Upright vertical positioning is very important because:
100G Datalogging FN remote gas modules are designed with the antenna in a
vertical direction so the antenna is parallel to the reading device (which has a vertical antenna). Matching antenna polarity can greatly affect RF performance and enable easy ERT module reading.
100G Datalogging FN remote gas modules are designed so the tilt tamper is
vertical. It is important to maintain vertical positioning in the field to enable tilt tamper stability.
Warning Do not mount the 100G Datalogging FN remote ERT module in an orientation other than vertical (remote ERT module label arrow pointed upward or downward). Violating the mounting orientation requirements will void the product warranty.
Select a proper mounting location. Itron recommends mounting the 100G Datalogging FN remote ERT module in close proximity to the meter or instrument. Some applications may require an extended cable­length. The 100G Datalogging FN remote ERT module supports cable lengths up to 300 feet.
Mount the 100G Datalogging FN remote ERT module in a vertical position with the ERT module label directional arrow pointed upward.
Mounting the 100G Datalogging FN Remote ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 8 Proprietary and Confidential
Mounting the Remote ERT Module on a Pipe
Itron Part Number
Description
ERG-5003-501 ERG-5003-502 ERG-5003-503 ERG-5003-505
100G Datalogging FN Remote ERT Module
(ERG-5003-501 shown)
CFG-0005-003
Remote Mount Installation Kit Kit includes:
2 band clamps 2 tamper seals pipe bracket cable ties adapter plate
Screws:
(2) 1/2-inch - to attach the adapter plate to pipe bracket (2) 1-inch - to attach the ERT module to the adapter plate (3) 1 1/2-inch - to attach the ERT module to a vertical surface
(wall)
Warning Install the 100G Datalogging FN remote ERT module in an upright position. Any position other than upright can negatively affect radio performance and potentially reduce battery life.
Caution Vertical mounting position is important to maximize RF performance. Mount the 100G Datalogging FN remote ERT module with the module's label arrow pointing up. The module's arrow must never point to either side or upside down. The module's tilt tamper functionality is designed to operate with the module installed vertically.
The following items are required to mount the 100G Datalogging FN remote ERT module on a pipe or vertical flat surface (wall):
To mount the pipe bracket on a vertical pipe
1. Remove the pipe bracket and band clamp from the Remote Mount Installation Kit (Itron part number
CFG-0005-003).
Mounting the 100G Datalogging FN Remote ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 9 Proprietary and Confidential
2. Loosen the band clamp screw until the end of the band releases.
3. Push the end of the clamp's band (1) through the holes (2) in the pipe bracket. The pipe bracket must be
oriented as shown below.
4. Place the band clamp around the pipe. The band will loosely wrap around the pipe. Push the end of the
band through the band clamp screw assembly. Turn the band clamp's screw assembly to fit into the pipe bracket opening. Tighten the clamp screw until the band clamp is secure on the pipe.
Caution The pipe bracket must fit firmly against the pipe to prevent slippage.