Warning Follow these procedures to avoid injury to yourself or others:
The lithium battery may cause a fire or chemical burn if it is not disposed of properly.
Do not recharge, disassemble, heat above 100º Celsius (212º Fahrenheit), crush, expose to
water, or incinerate the lithium battery. Fire, explosion, and severe burn hazard.
Keep the lithium battery away from children.
Replace the lithium battery only with batteries meeting Itron specifications. Any other battery
may cause a fire or explosion.
Warning Only authorized Itron personnel should attempt repairs on Itron equipment. Attempts to do so
by others might void any maintenance contract with your company. Unauthorized service personnel might
also be subject to shock hazard on some Itron equipment if removal of protective covers is attempted.
Warning To prevent ignition of flammable or combustible atmospheres, disconnect power before
servicing.
Warning Substitution of components may impair intrinsic safety.
100G Datalogging FN ERT Module Installation Guide - Remote Mount
01/10/2011 TDC-0824-003
100G Remote Mount ERT Module part numbers: ERG-5000-501, ERG-5000-502, ERG-5000-503
100G Datalogging Remote Mount ERT Module: ERG-5002-501, ERG-5002-502, ERG-5002-503, ERG-5002-505
Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two conditions:
This device may not cause harmful interference. This device must accept any interference that may cause undesirable operation.
This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels.
Compliance Statement
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Déclaration de conformité
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Transportation Classification
The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, the 100G Datalogging FN remote ERT module is considered an
operating transmitter and receiver and cannot be shipped by air. All product returns must be shipped by ground transportation.
Modifications and Repairs
To ensure system performance, this device and antenna shall not be changed or modified without the expressed approval of Itron. Any unauthorized modification will void the user's authority to
operate the equipment.
Meter Installation/Removal
In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of users requiring service to report the need for service to Itron.
Suggestions
If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com
If you have questions or comments about the software or hardware product, contact Itron Technical Support:
Contact
Internet: www.itron.com
E-mail: support@itron.com
Phone: 1 877 487 6602
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount iii
Proprietary and Confidential
Before You Begin .......................................................................................................... v
Contents
Document Purpose .............................................................................................................................. v
Direct Mounting the Remote ERT Module to the Sonix Meter ................................................ 75
Connecting the Remote ERT Module to a Sensus Sonix 600 or 880 Meter .......................... 76
Programming the 100G Datalogging FN Remote ERT Module .............................................. 77
Index ............................................................................................................................. 79
Before You Begin
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount v
Proprietary and Confidential
The following documentation conventions are used:
Caution A Caution warns the user that failure to heed the information in the
note could result in loss of data. Be sure to carefully read a Caution note and
follow the advice/instructions.
Warning A Warning alerts you about potential physical harm to the user or
hardware. It is critical that you pay strict attention to Warning notes, read the
information carefully, and follow the advice/instructions.
Before You Begin
Tip A Note provides the user with extra hints to make a task easier to perform
or a concept easier to understand.
Note A Note supplies generic information to the user. The user could ignore
the information and continue a task without suffering any adverse
consequences.
Document Purpose
This installation guide provides step-by-step instructions for installing the 100G Series remote gas ERT
module on a wide variety of meters and instruments. This installation guide refers to the 100G series remote
ERT module as the 100G Datalogging FN remote ERT module. Mechanical and electrical installation
procedures are similar for all modules. 100G Datalogging FN remote ERT module compatible meters and
instruments are listed in the 100G Datalogging FN Remote ERT Module Meter Compatibility List on page 3.
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 1
Proprietary and Confidential
Itron 100G series remote ERT modules are radio-frequency (RF) devices designed to transmit meter data to an
C H A P T E R 1
100G Datalogging FN ERT Module
RF meter reading device within transmission distance of the remote ERT module. The 100G remote gas ERT
module was designed with a higher output power than earlier Itron remote gas ERT modules to achieve an
increased RF transmission distance. The 100G series remote gas ERT modules have greater output power to
meet Itron mobile and fixed network requirements. The first 100G remote gas ERT module offered high
transmit power capability which increased operational efficiency and reduced infrastructure costs. The 100G
Datalogging remote gas ERT module offers high transmit power with data logging capability (time-stamped
hourly interval data) for both mobile and fixed network applications. Itron's 100G Datalogging Fixed Network
(DLN) remote gas ERT module adds improved network performance through even higher transmit power,
accomplished using increased antenna efficiency and more robust optimized messaging structures.
The 100G Datalogging FN remote ERT module features tilt-tamper and cut cable-tamper reporting and
security seals to indicate physical tampering and minimize theft. Cut cable is reported when the cable is cut or
disconnected from the meter, instrument, or endpoint. 100G Datalogging FN remote ERT module circuitry
senses an electrical current break to report a cut cable tamper event.
Transmission Modes
The 100G Datalogging FN remote ERT module can be set to transmit in Fixed Network, Mobile and
Handheld, or Hard to Read Mobile and Handheld Mode.
Fixed Network Mode. The 100G Datalogging FN remote gas ERT transmits a high-powered network
interval message (NIM) RF message every five minutes. Output power in this mode is 500 milliwatts or
+27 dBm. Interspersed in the high power NIM, the 100G Datalogging FN remote ERT module transmits a
medium power RF message at 10 milliwatts or +10 dBm; expected battery life is 20 years.
Mobile High Power Mode. The 100G series remote gas ERT transmits a high-powered RF message
every 60 seconds. Output power in this mode is 250 milliwatts or +24dbm; expected battery life is 20
years.
Mobile and Handheld Mode. The 100G series remote gas ERT transmits a medium-powered RF
message every 15 seconds. Output power in this mode is 10 milliwatts or +10dBm; expected battery life is
20 years.
(Optional) Hard to Read Mobile and Handheld Mode. The 100G series remote FN gas module
transmits a high-powered RF message every 30 seconds. Output power in this mode is 250 milliwatts or
+24dBm; expected battery life decreases to 15 years in this mode. The Hard to Read Mobile and Handheld Mode should only be used for exceptionally hard-to-read applications (such as meters installed
on roof tops or in sub-basements).
An FCC license is not required to read 100G series remote gas ERT modules.
100G Datalogging FN ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 2
Proprietary and Confidential
Specifications
Functional Specifications
Description
Power source
Two "A" cell lithium batteries
Tamper detection
Tilt tamper and cut cable tamper
FCC compliance
Part 15 certified
Industry Canada compliance
RSS-210 certified
Intrinsically safe per
UL Class I, Division 1, Groups C and D
Product identification
Numeric and bar-coded ERT module type and serial number
Construction materials
Gray polycarbonate housing and back plate with encapsulated
electronics
Operational Specifications
Description
Operating temperatures
-40° to 158° F (-40° to +70° C)
Operating humidity
5 to 95 percent relative humidity
Program frequency
908 MHz
Transmit frequency
Spread spectrum 908 to 924 MHz ISM band
Data integrity
Verified in every data message
Document Title
Document Part Number
Gas Endpoint Meter Compatibility List
PUB-0117-002
Gas Endpoint Ordering Guide
PUB-0117-001
100G Datalogging Specification Sheet
Publication 100941SP-XX
Endpoint Link Programming Guide
TDC-0744*
Field Deployment Manager Endpoint Tools Mobile
Application Guide
TDC-0934*
Field Deployment Manager Field Representative's
Guide
TDC-0936*
The functional and operational specifications for the 100G Datalogging FN remote ERT module are listed
below.
Related Documents
*The last three digits of the user and installation guides represent the document's revision level. The revision
level is subject to change without notice.
100G Datalogging FN ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 3
Proprietary and Confidential
100G Datalogging FN Remote ERT Module Meter Compatibility
2.5' cable with encoder
Also requires thicker gasket for
magnet hub to clear index box.
1-hole gasket: FAB-0014-001
2-hole gasket: FAB-0014-002
4-hole gasket: FAB-0014-003
American RPM series
rotary meters including
TC and non-TC.
Commercial
Meter must have a factory
installed pulser with connector
output. Purchase endpoint from
Itron and correct cable interface
from appropriate meter
manufacturer.
100G Remote (12' lead wires)
100G Datalogging Remote
(12" lead wires)
100G Datalogging FN
Remote (12" lead wires)
ERG-5000-503
ERG-5002-503
ERG-5003-503
Romet
STD CTR
600 through 56000
TC 2000 through 23000
RM series
Commercial
Meter must have a factory
installed pulser with connector
output. Purchase endpoint from
Itron and correct cable interface
from appropriate meter
manufacturer.
100G Remote (12' lead wires)
100G Datalogging Remote
(12" lead wires)
100G Datalogging FN
Remote (12" lead wires)
ERG-5000-503
ERG-5002-503
ERG-5003-503
List
This table lists meters compatible with the 100G Datalogging FN remote ERT module. Due to continuous
research, product improvements, and enhancements Itron reserves the right to change this list without notice.
100G Datalogging FN ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 4
Proprietary and Confidential
Meter
Model
Description
Class
Comments
ERT Module Type
ERT Module
Part Number
Romet
RM Series
ECM2
Electronically
compensated meter
Commercial
Meter must have connector pin
with factory-installed pulse
output. Purchase endpoint from
Itron and correct cable interface
from Romet. ECM2 must be
configured for 750ms "offtime" between pulses. The
ECM2 must have firmware
version J or later.
100G Datalogging Remote
(12" lead wires)
100G Datalogging FN
Remote (12" lead wires)
ERG-5002-503
ERG-5003-503
Dresser ROOTS®
B3/LMMA
Dresser ROOTS
®
rotary meters equipped
with WeigandWire
solid state pulsers
Commercial
Meter must have factoryinstalled pulser with connector
output. Purchase endpoint from
Itron and correct cable interface
from Dresser. Dresser pulser
must be version 17 or higher to
be compatible.
100G Remote (12" lead
wires)
100G Datalogging Remote
(12" lead wires)
100G Datalogging FN
Remote (12" lead wires)
ERG-5000-503
ERG-5002-503
ERG-5003-503
Dresser ROOTS®
IMC/W2
MC2
Dresser ROOTS
®
Micro Correctors
Commercial
Endpoint compatibile with
IMC/W2 firmware version
1.93 or earlier. Pulse width
must be set for 125ms. Pulse
output must be at 100CF(CM)
or higher.
100G Datalogging Remote
(12” lead wires)
100G Datalogging FN
Remote (12" lead wires)
ERG-5002-505
ERG-5003-505
Itron/Actaris
DATTUS fM2/fM3
Commercial
For all meter types, pulse width
must be set to .050 seconds.
Meter type 11M or smaller
must have pulse weight
minimum of 10 cubic feet or 1
cubic meter. Meter type 16M
or greater must have pulse
weight minimum of 100 cubic
feet or 1 cubic meter.
Pressure and
temperature electronic
volume correctors
Commercial
Correctors must have a Form A
board; Form C is NOT
supported. Item #056 Pulse
Scaling Factor must be set to
2.0. Item #096 Cor Vol Display
must be set at 1, 2, 3, or 4
blanks. endpoint does NOT
support a setting of 0 blanks.
Item #115 Output Pulse Code
must be set at 1, 2, 3, or 4.
endpoint does NOT support an
Output Pulse Code of 0.
Correctors must have a Form
A board, Form C is NOT
supported. Item #56 Pulse
Scaling Factor must be 2.0.
Item #96 must be 7, 6, 5, or 4
digits (1, 2, 3, & 4 blanks).
Endpoint does NOT support 8
digits (0 blanks). Item # 1014
set to the preset “Itron”
selection in the drop down
menu. Compatible firmware
versions on TCI are 1.06,
1.07, and 1.10.
100G Datalogging Remote
(5’ cable)
100G Datalogging Remote
(12” lead wires)
100G Datalogging FN
Remote (5’ cable)
100G Datalogging FN
Remote (12" lead wires)
5’: ERG-5002-502
12”:ERG-5002-503
ERG-5003-502
ERG-5003-503
100G Datalogging FN ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 5
Proprietary and Confidential
Installation Prerequisites
Note Reference the appropriate programming guide or specification sheet for correct software
version (see Related Documents on page 2).
The following tools are required to install, program, and check the 100G Datalogging FN remote ERT
module. Some specific tools may be required dependent on meter or instrument type.
Medium flat-blade screwdriver Small flat-blade screwdriver Medium Phillips screwdriver Hand pliers Side-cutting pliers 1/4-inch nut driver or similar blunt tool One-inch width putty knife Adjustable wrench 3M Scotchlock E-9Y crimping tool, 3M Scotchlock E-9C cartridge tool, or similar crimping tool All-weather electrical tape Size T-10 Torx screwdriver Itron programming device to program and check 100G Datalogging FN remote gas ERT module
installation and operation:
FC200SR handheld computer with Endpoint-Link or Endpoint-Link Pro software version 5.3 or higher or
Field Deployment Manager (FDM) software version 1.1 or higher
or
FC300 with SRead with Endpoint-Link or Endpoint Link Pro version 5.5 or higher or Field Deployment
Manager (FDM) software version 1.1 or higher
or
900 MHz Belt Clip Radio with Endpoint-Link version 5.5 or higher or Field Deployment Manager (FDM)
software version 1.1 or higher and a customer-supplied laptop
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 6
Proprietary and Confidential
This chapter provides the instructions to mount the 100G Datalogging FN remote ERT module on a pipe or
Application
Itron Part
Number
Description
To mount adapter plates on
pipe brackets
575-9930-016
8-16 x 1/2-inch length, Type 8 slotted pan-head
tapping screw - corrosion-resistant steel
To mount remote ERT
modules on adapter plates
575-9930-032
8-16 x 1-inch Type 8, slotted pan-head tapping
screw, corrosion-resistant steel
To mount remote ERT
modules on sheet metal
surfaces (to mount ERT
modules to wood surfaces, a
comparable wood screw is
required)
SCR-0009-001
10-16 x 1 1/2-inch Type AB thread for sheet
metal, Phillips pan-head tapping screw,
corrosion-resistant steel
C H A P T E R 2
Mounting the 100G Datalogging FN Remote ERT Module
other flat vertical surface (wall).
Installation Options
Mount the 100G Datalogging FN remote ERT module using the Pipe Mount or Wall Mount (Flat Surface)
procedure.
Pipe Mount. Pipe mounting is used in conjunction with the Remote Mount Kit (Itron part number CFG-
0005-003). The pipe mount option places the ERT module on a pipe near the meter or instrument (not on a
wall surface). This option requires a meter manufacturer's cable to connect the ERT module to the meter
or instrument.
Flat Vertical (Wall) Mount. Installation using the wall mount option places the ERT module on a wall or
other vertical surface. A cable connects the ERT module to the meter or instrument.
Mounting Screw Specifications
Mounting the 100G Datalogging FN Remote ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 7
Proprietary and Confidential
Mounting Installation Considerations
Caution Upright vertical positioning is very important because:
100G Datalogging FN remote gas modules are designed with the antenna in a
vertical direction so the antenna is parallel to the reading device (which has a
vertical antenna). Matching antenna polarity can greatly affect RF performance
and enable easy ERT module reading.
100G Datalogging FN remote gas modules are designed so the tilt tamper is
vertical. It is important to maintain vertical positioning in the field to enable tilt
tamper stability.
Warning Do not mount the 100G Datalogging FN remote ERT module in an orientation other
than vertical (remote ERT module label arrow pointed upward or downward). Violating the
mounting orientation requirements will void the product warranty.
Select a proper mounting location. Itron recommends mounting the 100G Datalogging FN remote ERT
module in close proximity to the meter or instrument. Some applications may require an extended cablelength. The 100G Datalogging FN remote ERT module supports cable lengths up to 300 feet.
Mount the 100G Datalogging FN remote ERT module in a vertical position with the ERT module label
directional arrow pointed upward.
Mounting the 100G Datalogging FN Remote ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 8
Proprietary and Confidential
2 band clamps 2 tamper seals pipe bracket cable ties adapter plate
Screws:
(2) 1/2-inch - to attach the adapter plate to pipe bracket (2) 1-inch - to attach the ERT module to the adapter plate (3) 1 1/2-inch - to attach the ERT module to a vertical surface
(wall)
Warning Install the 100G Datalogging FN remote ERT module in an upright position. Any
position other than upright can negatively affect radio performance and potentially reduce
battery life.
Caution Vertical mounting position is important to maximize RF performance. Mount the 100G
Datalogging FN remote ERT module with the module's label arrow pointing up. The module's arrow must never point to either side or upside down. The module's tilt tamper functionality is
designed to operate with the module installed vertically.
The following items are required to mount the 100G Datalogging FN remote ERT module on a pipe or
vertical flat surface (wall):
To mount the pipe bracket on a vertical pipe
1. Remove the pipe bracket and band clamp from the Remote Mount Installation Kit (Itron part number
CFG-0005-003).
Mounting the 100G Datalogging FN Remote ERT Module
TDC-0824-003 100G Datalogging FN ERT Module Installation Guide - Remote Mount 9
Proprietary and Confidential
2. Loosen the band clamp screw until the end of the band releases.
3. Push the end of the clamp's band (1) through the holes (2) in the pipe bracket. The pipe bracket must be
oriented as shown below.
4. Place the band clamp around the pipe. The band will loosely wrap around the pipe. Push the end of the
band through the band clamp screw assembly. Turn the band clamp's screw assembly to fit into the pipe
bracket opening. Tighten the clamp screw until the band clamp is secure on the pipe.
Caution The pipe bracket must fit firmly against the pipe to prevent slippage.