Itron 100GDLCN, 100GDLAN Users Manual

Gas Solutions
100G Datalogging Installation Guide - Direct
Mount
TDC-0823-005
Identification
Warning Follow these procedures to avoid injury to yourself or others:
The lithium battery may cause a fire or chemical burn if it is not disposed of
properly.
Do not recharge, disassemble, heat above 100º Celsius (212º Fahrenheit), or
incinerate the lithium battery. Keep the lithium battery away from children. Replace the lithium battery only with batteries meeting Itron specifications. Any
other battery may cause a fire or explosion.
Warning Only authorized Itron personnel should attempt repairs on Itron equipment. Attempts to do so by others might void any maintenance contract with your company. Unauthorized service personnel might also be subject to shock hazard on some Itron equipment if removal of protective covers is attempted.
Warning To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing.
Warning Substitution of components may impair intrinsic safety.
100G Datalogging Installation Guide - Direct Mount 07/28/2010 TDC-0823-005
Endpoint part numbers: 100G Endpoint: ERG-5000-001, ERG-5000-002, ERG-5000-003, ERG-5000-004, ERG-5000-005, ERG-5000-006, ERG-5000-007, ERG-5000-008 100G Datalogging Endpoint: ERG-5002-001, ERG-5002-002, ERG-5002-003, ERG-5002-004, ERG-5002-007, ERG-5002-008 Copyright © 2009 - 2010 Itron, Inc. All rights reserved. Confidentiality Notice The information contained herein is proprietary and confidential and is provided subject to the condition that (i) it be held in confidence except to the extent required otherwise by law and (ii) it is used only for the purposes described herein. Any third party given access to this information shall be similarly bound in writing. Trademark Notice Itron is a registered trademark of Itron, Inc. All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies. Applicable Patents U.S. Patent Numbers: 4,614,945; 4,753,169; 4,768,903; 4,799,059; 4,867,700 Canadian Patent Numbers: 1,254,949; 1,267,936; 1,282,118
Compliance Statement This device complies with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Operation is subject to the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference that may cause undesirable operation. This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels. Compliance Statement This equipment has been tested and found to comply with the limits, pursuant to Part 15 of the FCC Rules. These limits are d esigned to provide reasonable protection against harmful interference in a residential installation. Operation is subject to the following conditions:
• This device may not cause interference.
• This device must accept any interference that may cause undesired operation of the device. Compliance Statement This equipment complies with policies RSS-210 and RSS-GEN of the Industry Canada rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Transportation Classification The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, the 100G Datalogging Endpoint is considered an operating transmitter and receiver and cannot be shipped by air. All product returns must be shipped by ground transportation. Modifications and Repairs To ensure system performance, this device and antenna shall not be changed or modified without the expressed app roval of Itron. Any unauthorized modification will void the user's authority to operate the equipment. Meter Installation/Removal In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of users requiring service to report the need for service to Itron.
Suggestions
Caution A Caution warns the user that failure to follow the information in the note could result in loss of data. Be sure to carefully read a Caution note and follow the advice/instructions.
Warning A Warning alerts you about potential physical harm to the user or hardware. It is critical that you pay strict attention to Warning notes, read the information carefully, and follow the advice, instructions.
Tip A Tip provides the user with extra hints/suggestions to make a task easier to perform or a concept easier to understand.
Note A Note supplies generic information to the user. The user can ignore the information and continue a task without suffering any adverse consequences.
If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com If you have questions or comments about the software or hardware product, contact Itron Technical Support: Contact
Internet: www.itron.com E-mail: support@itron.com Phone: 1 877 487 6602
Document Conventions
The following documentation conventions are used in this installation guide:
TDC-0823-005 100G Datalogging Installation Guide - Direct Mount v
Proprietary and Confidential
Chapter 1 100G Datalogging Gas Endpoint ............................................................... 1
Contents
Transmission Modes ........................................................................................................................... 1
Specifications ...................................................................................................................................... 2
Related Documents .................................................................................................................. 2
Meter Compatibility List ....................................................................................................................... 2
Installation Prerequisites ..................................................................................................................... 7
Installation Overview ................................................................................................................. 9
Chapter 2 Elster American Meter Installation .......................................................... 10
Programming the 100G Datalogging Gas Endpoint Assembly ......................................................... 15
Attaching the 100G Datalogging Gas Endpoint Assembly to the Meter ........................................... 16
Chapter 3 Sensus/Rockwell Meter Installation ........................................................ 19
Programming the 100G Datalogging Gas Endpoint Assembly ......................................................... 23
Attaching the 100G Datalogging Gas Endpoint Assembly to the Sensus Meter .............................. 25
Chapter 4 Itron/Sprague Meter Installation .............................................................. 28
Programming the 100G Datalogging Gas Endpoint Assembly ......................................................... 31
Attaching the 100G Datalogging Gas Endpoint Assembly to the Meter .......................................... 32
Attaching the 100G Datalogging Gas Endpoint Assembly to Flat-faced Sprague Meters ..... 35
Securing Brass Meter Tags to Flat-faced Meters ................................................................... 39
Chapter 5 National/Lancaster Meter Installation ...................................................... 42
Programming the 100G Datalogging Gas Endpoint Assembly ......................................................... 48
Attaching the 100G Datalogging Gas Endpoint Assembly to the Meter ........................................... 49
Chapter 6 Elster American and Itron Actaris Commercial Meter Installation ........ 52
Removing the Index/ Index Assembly from the Meter ...................................................................... 52
Programming the 100G Datalogging Commercial Gas Endpoint ..................................................... 55
Installing the 100G Datalogging Commercial Gas Endpoint on an Itron/Actaris
Commercial Meter ............................................................................................................................. 62
Chapter 7 Sensus/Rockwell Commercial Meter Installation ................................... 68
Removing the Index/ Index Assembly from the Meter ...................................................................... 68
Programming the 100G Datalogging Gas Endpoint .......................................................................... 70
Attaching the 100G Datalogging Commercial Endpoint to a Sensus/Rockwell Commercial Diaphram
Meter ................................................................................................................................................. 71
Mounting a on a Rockwell 750 meter with an Aluminum BOX Direct Reading (VDR) .................... 75
Contents
TDC-0823-005 100G Datalogging Installation Guide - Direct Mount vi
Proprietary and Confidential
Chapter 8 Dresser ROOTS® Commercial Rotary Meter Installation ....................... 80
Installation Prerequisites ......................................................................................................... 80
Installation Examples ........................................................................................................................ 81
Programming the 100G Datalogging Gas Endpoint Assembly ......................................................... 82
B3, LMMA, and S3A CTR/TC Dresser ROOTS® Series Register Settings and Direct Drive
Programming Information .................................................................................................................. 83
B3, LMMA and S3A CTR/TC Meter Drive Rates: Residential Direct Drive Programming* ... 84 Installing the Residential 100G Datalogging Gas Endpoint Assembly to the Dresser ROOTS®
Rotary Meter ...................................................................................................................................... 85
Installing the 100G Datalogging Commercial Gas Endpoint on a Dresser ROOTS® Rotary Meter
with an Instrument Drive .................................................................................................................... 86
Programming the 100G Datalogging Commercial Gas Endpoint Assembly .......................... 88
B3, LMMA, and S3A CD/TD Dresser ROOTS® Series Meter Drive Rates ............................. 90
To attach the 100G Datalogging commercial gas endpoint to the meter ............................... 91
Completed Installation Examples ............................................................................................ 94
Index ............................................................................................................................. 95
TDC-0823-005 100G Datalogging Installation Guide - Direct Mount 1 1
Proprietary and Confidential
Itron 100G Datalogging gas endpoints are radio-frequency (RF) devices designed to transmit meter data to an
C H A P T E R 1
100G Datalogging Gas Endpoint
RF meter reading device within transmission distance of the endpoint. 100G Datalogging gas endpoints have the same increased output power as the first generation 100G gas endpoints for greater RF transmission distance. The 100G direct-mount endpoint reads and transmits a Standard Consumption Message (SCM) with magnetic-tamper and tilt-tamper data. The Itron 100G Datalogging gas endpoint adds functionality by storing up to 40 days of hourly data.
This installation guide provides step-by-step instructions for installing the 100G gas endpoint and the 100G Datalogging gas endpoint on a wide variety of meters. This installation guide refers to both 100G endpoint versions as the 100G Datalogging gas endpoint. Mechanical installation procedures are identical for both modules. 100G Datalogging gas endpoint compatible meters are listed in the Meter Compatibility List.
Transmission Modes
The 100G Datalogging gas endpoint can be set to transmit in Fixed Network, Mobile and Handheld, or Hard to Read Mobile and Handheld Mode.
Fixed Network Mode The 100G Datalogging gas endpoint transmits a high-powered RF message every
60 seconds. Output power in this mode is 250 milliwatts or +24 dBm; expected battery life is 20 years.
Mobile and Handheld Mode The 100G Datalogging gas endpoint transmits a medium-powered RF
message every 15 seconds. Output power in this mode is 10 milliwatts or +10dBm; expected battery life is 20 years.
(Optional) Hard to Read Mobile and Handheld Mode The 100G Datalogging gas endpoint transmits a
high-powered RF message every 30 seconds. Output power in this mode is 250 milliwatts or +24dBm; expected battery life decreases to 15 years in this mode. The Hard to Read Mobile and Handheld Mode should only be used for exceptionally hard-to-read applications (such as meters installed on roof tops or in sub-basements).
An FCC license is not required to read 100G Datalogging gas endpoint.
100G Datalogging Gas Endpoint
TDC-0823-005 100G Datalogging Installation Guide - Direct Mount 2
Proprietary and Confidential
Specifications
Functional Specifications
Description
Power Source 100G
100G Datalogging
Two "A" cell lithium batteries One "A" cell lithium battery
Tamper Detection
Tilt tamper and magnetic tamper
FCC Compliance
Part 15 certified
Industry Canada Compliance
RSS-210 certified
Intrinsically Safe per
UL Class I, Division 1, Groups C and D
Product Identification
Numeric and barcoded endpoint type and serial number
Construction Materials
Gray polycarbonate housing and back plate with encapsulated electronics
Operational Specifications
Description
Operating Temperatures
-40° to 158° F (-40° to +70° C)
Operating Humidity
5 to 95 percent relative humidity
Program Frequency
908 MHz
Transmit Frequency
Spread spectrum 908 to 924 MHz ISM band
Data Integrity
Verified in every data message
Document Title
Document Part Number
Gas Endpoint Meter Compatibility List
PUB-0117-002
Gas Endpoint Ordering Guide
PUB-0117-001
100G Datalogging Specification Sheet
Publication 100941SP-XX
Endpoint Link® Programming Guide
TDC-0744
Note On rare occasions the location of endpoint-to-meter mounting holes on older diaphragm gas meters might not match up with the mounting holes on the 100G Datalogging gas endpoint. This can prevent the 100G Datalogging gas endpoint from properly mounting to the meter.
Related Documents
Meter Compatibility List
This table lists meters compatible with the 100G Datalogging gas endpoint. Due to continuous research, product improvements, and enhancements, Itron reserves the right to change this list without notice.
100G Datalogging Gas Endpoint
TDC-0823-005 100G Datalogging Installation Guide - Direct Mount 3
Proprietary and Confidential
100G Series Meter Compatibility List
Mfg.
Model
Description
Class
Comments
Endpoint Type
Endpoint Part No.
Elster American/ Canadian
W75AL
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
AL-175
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
AC-175
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
AT-175
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
ALC-175
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
AT-210
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
AL-225
Canada only
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian AC-250
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
AL-250
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
AM-250
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
AR-250
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
AT-250
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
AL-310
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
AL-350
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
AT-350
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
AL-425
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
AC-630
Residential
Aluminum case meters only
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
5B 225
Aluminum case
Residential
100G 100G Datalogging
ERG-5000-001 ERG-5002-001
Elster American/ Canadian
35B
Iron case
Commercial
100G 100G Datalogging
ERG-5000-007 ERG-5002-007
Elster American/ Canadian
60B
Iron case
Commercial
100G 100G Datalogging
ERG-5000-007 ERG-5002-007
Elster American/ Canadian
80B
Iron case
Commercial
Must have front reading index.
100G 100G Datalogging
ERG-5000-007 ERG-5002-007
Elster American/ Canadian
250B
Iron case
Commercial
100G 100G Datalogging
ERG-5000-007 ERG-5002-007
Elster American/ Canadian
500B
Iron case
Commercial
100G 100G Datalogging
ERG-5000-007 ERG-5002-007
Elster American/ Canadian
AL800
Commercial
Aluminum case meters only
100G 100G Datalogging
ERG-5000-007 ERG-5002-007
100G Datalogging Gas Endpoint
TDC-0823-005 100G Datalogging Installation Guide - Direct Mount 4
Proprietary and Confidential
Mfg.
Model
Description
Class
Comments
Endpoint Type
Endpoint Part No.
Elster American/ Canadian
AL1000
Commercial
Aluminum case meters only
100G 100G Datalogging
ERG-5000-007 ERG-5002-007
Elster American/ Canadian
AL1400
Commercial
Aluminum case meters only
100G 100G Datalogging
ERG-5000-007 ERG-5002-007
Elster American/ Canadian
AL2300
Commercial
Aluminum case meters only
100G 100G Datalogging
ERG-5000-007 ERG-5002-007
Elster American/ Canadian
AL3000
Commercial
Aluminum case meters only
100G 100G Datalogging
ERG-5000-007 ERG-5002-007
Elster American/ Canadian
AL5000
Commercial
Aluminum case meters only
100G 100G Datalogging
ERG-5000-007 ERG-5002-007
Sensus/Invensys/ Equimeter/Rockwell
R-175
11-tooth
Residential
24- and 30-tooth gears are not compatible.
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/ Equimeter/Rockwell
R-200
11-tooth
Residential
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/ Equimeter/Rockwell
RT-200
11-tooth
Residential
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/ Equimeter/Rockwell
RC-225
11-tooth (Canada only)
Residential
24- and 30-tooth gears are not compatible.
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/ Equimeter/Rockwell
RT-225
11-tooth
Residential
24- and 30-tooth gears are not compatible.
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/ Equimeter/Rockwell
RC-230
11-tooth
Residential
24- and 30-tooth gears are not compatible.
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/
Equimeter/Rockwell
RCM-230 (RC-230 Metric)
16-tooth
Residential
24- and 30-tooth gears are not compatible.
100G 100G Datalogging
ERG-5000-003 ERG-5002-003
Sensus/Invensys/ Equimeter/Rockwell
RT-230
11-tooth
Residential
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/ Equimeter/Rockwell
R-275
11-tooth
Residential
24- and 30-tooth gears are not compatible.
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/ Equimeter/Rockwell
RT-275
11-tooth
Residential
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/ Equimeter/Rockwell
S-275 (side connection)
11-tooth
Residential
24- and 30-tooth gears are not compatible.
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/ Equimeter/Rockwell
R-315
11-tooth
Residential
24- and 30-tooth gears are not compatible.
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/ Equimeter/Rockwell
250
11-tooth
Residential
24- and 30-tooth gears are not compatible.
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/ Equimeter/Rockwell
310
11-tooth
Residential
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/ Equimeter/Rockwell
S-110
11-tooth
Residential
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/ Equimeter/Rockwell
S-200
11-tooth
Residential
100G 100G Datalogging
ERG-5000-002 ERG-5002-002
Sensus/Invensys/ Equimeter/Rockwell
S-175
18-tooth
Residential
24- and 30-tooth gears are not compatible.
100G 100G Datalogging
ERG-5000-004 ERG-5002-004
Sensus/Invensys/ Equimeter/Rockwell
RT-100
18-tooth
Residential
24- and 30-tooth gears are not compatible
100G 100G Datalogging
ERG-5000-004 ERG-5002-004
Sensus/Invensys/ Equimeter/Rockwell
S-190
18-tooth
Residential
24- and 30-tooth gears are not compatible.
100G 100G Datalogging
ERG-5000-004 ERG-5002-004
Sensus/Invensys/ Equimeter/Rockwell
S-120
11-tooth
Residential
100G 100G Datalogging
ERG-5000-002 ERG-5002-002