U.S. Patent Numbers: 4,614,945; 4,753,169; 4,768,903; 4,799,059; 4,867,700
Canadian Patent Numbers: 1,254,949; 1,267,936; 1,282,118
Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference that may cause undesi r a ble operation.
This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels.
Compliance Statement
This equipment has been tested and found to comply with the limits, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection agai nst harmful
interference in a residential installation. Operation is subject to the following conditions:
• This device may not cause interference.
• This device must accept any interference that may cause undesired operation of the device.
Compliance Statement
This equipment complies with policies RSS-210 and RSS-GEN of the Industry Canada rules. Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Trademark Notice
Itron and Endpoint-Link are registered trademarks of Itron, Inc.
All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.
Suggestions
If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com
If you have questions or comments about the software or hardware product, contact Itron Technical Support:
Contact
• Mail: Itron, Inc. Attention: Customer Care, 2111 N Molter Road, Liberty Lake, WA 99019
• Internet: www.itron.com
• E-mail: support@itron.com
• Phone: 1 800 635 87 25
WARNING! Follow these procedures to a vo id injury to yourself or others:
•The lithium battery may cause a fire or chemical burn if it is not disposed of properly.
•Do not recharge, disassemble, heat above 100° Celsius (212° Fahrenheit), or incinerate
the lithium battery.
•Keep the lithium battery away from children.
•Replace the lithium battery only with batteries meeting Itron specifications. Any other battery
may cause a fire or explosion.
WARNING! Only authorized Itron personnel should attempt repairs on Itron equipment.
Attempts to do so by others might void any maintenance contract with your company.
Unauthorized service personnel might also be subject to shock hazard on some Itron equipment
if removal of protective covers is attempted.
WARNING! To prevent ignition of flammable or combustible atmospheres, disconnect power
before servicing.
WARNING! Substitution of components may impair intrinsic safety.
100G Datalogging Installation G uide - Direct Mount ii
Transportation Classification
The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, the 100G Datalogging Endpoint is considered an operating
transmitter and receiver and cannot be shipped by air. All product returns must be shipped by ground transportation.
Modifications and Repairs
To ensure system performance, this device and antenna shall not be changed or modified without the expressed approval of Itron. Any unauthorized modification will void the user's
authority to operate the equipment.
Meter Installation/Removal
In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of users requiring service to report the need for service to Itron.
100G Datalogging Installation G uide - Direct Mount iii
Document Conventions
The following documentation conventions are used:
CAUTION! This type of note warns the user that failure to heed the
information in the note could result in loss of data. Be sure to carefully
read a CAUTION note and heed the advice/instructions.
WARNING! This type of note is used to warn of potential physical harm
to the user or hardware. It is critical that you pay strict attention to
WARNING notes, read the information carefully, and heed the advice,
instructions.
This type of note provides the user with extra hints/tips to make a task
easier to perform or a concept easier to understand.
This type of note supplies generic information to the user. The
information could be ignored and the user could still continue with a task
without suffering any adverse consequences.
100G Datalogging Installation G uide - Direct Mount iv
Contents
Chapter 1 100G Datalogging Gas Endpoint ................................................................ 1
Programming the 100G Dataloggi ng Gas En dpo int As sembly ......................................................... 83
B3, LMMA, and S3A CTR/TC Dresser ROOTS Series Register Settings and Direct Drive
Programming Information .................................................................................................................. 85
B3, LMMA and S3A CTR/TC Meter Drive Rates: Residential Direct Drive Programming* ... 87
Installing the Residential 100G Datalogging Gas Endpoint Assembly to the Dresser
ROOTS Rotary Meter ........................................................................................................................ 89
Installing the 100G Datalogging Commercial Gas Endpoint on a Dresser ROOTS Rotary Meter ... 90
Programming the 100G Dataloggi ng Com mercial Gas Endpoint Assembly .......................... 91
B3, LMMA, and S3A CD/TD Dresser ROOTS Series Meter Drive Rates .............................. 93
To Attach the 100G Datalogging Commercial Gas Endpoint to the Meter ............................. 95
vi 100G Datalogging Ins t al lati on G uide - Direct Mount
C
1
HAPTER
100G Datalogging Gas Endpoint
Itron 100G Datalogging Gas Endpoints are radio-frequency (RF) devices designed to
transmit meter data to an RF meter reading device within transmission distance of the
endpoint. 100G Datalogging Gas Endpoints have the same increased output power as the
first generation 100G Gas Endpoints for greater RF transmission distance. The 100G directmount endpoint reads and transmits a Standard Consumption Message (SCM) with
magnetic-tamper and tilt-tamper data. The Itron 100G Datalogging direct-mount endpoint
adds functionality by storing up to 40 days of hourly data.
This installation guide provides step-by-step instructions for installing the 100G Gas
Endpoint and the 100G Datalogging Gas Endpoint on a wide variety of meters. This
installation guide refers to both 100G endpoint versions as the 100G Datalogging Endpoint.
Mechanical installation procedures are identical for both modules. 100G Datalogging Gas
Endpoint compatible meters are listed in the Meter Compatibility List.
Transmission Modes
The 100G Datalogging Gas Endpoint transmits in one of three modes:
•Fixed Network Mode In this mode, a 100G Datalogging Gas Endpoint transmits a
high-powered RF message every 60 seconds. Output power in this mode is 250
milliwatts or +24dBm; expected battery life is 20 years.
•Mobile and Handheld Mode In this mode, a 100G Datalogging Gas Endpoint
transmits a medium-powered RF message every 15 seconds. Output power in this
mode is 10 milliwatts or +10dBm; expected battery life is 20 years.
•(Optional) Hard to Read Mobile and Handheld Mode In this mode, a 100G
Datalogging Gas Endpoint transmits a high-powered RF message every 30 seconds.
Output power in this mode is 250 milliwatts or +24dBm; expected battery life
decreases to 15 years in this mode. The Hard to Read Mobile and Handheld Mode
should only be used for exceptionally hard-to-read applications (such as meters
installed on roof tops or in sub-basements).
An FCC license is not required to read 100G Datalogging Gas Endpoint.
100G Datalogging Installation G uide - Direct Mount 1
Chapter 1 100G Datalogging Gas Endpoint
Specifications
Functional Specifications Description
Power Source
100G
100G Datalogging
Tamper Detection
FCC Compliance
Industry Canada Compliance
Intrinsically Safe per
Product Identification
Construction Materials
Operational Specifications Description
Operating Te mperatures
Operating Humidity
Program Frequency
Transmit Frequency
Data Integrity
Two "A" cell lithium batteries
One "A" cell lithium battery
Tilt tamper and magnetic tamper
Part 15 certified
RSS-210 certified
UL Class I, Division 1, Groups C and D
Numeric and barcoded endpoint type and serial number
Gray polycarbonate housing and back plate with
encapsulated electronics
-40° to 158° F (-40° to +70° C)
5 to 95 percent relative humidity
908 MHz
Spread spectrum 908 to 924 MHz ISM band
Verified in every data message
Related Documents
Document Title Document Part Number
Gas Endpoint Meter Compatibility List PUB-0117-002
The Meter Compatibility table lists meters compatible with the 100G Datalogging Gas
Endpoint. Due to continuous research, product improvements, and enhancements, Itron
reserves the right to change this list without notice.
Note On rare occasions the location of endpoint-to-meter mounting holes on
older diaphragm gas meters might not match up with the mounting holes on the
100G Datalogging Gas Endpoint. This can prevent the 100G Datalogging Gas
Endpoint from properly mounting to the meter.
2 100G Datalogging Installation Guide - Direct Mount
Meter Compatibility List
100G Series Meter Compatibility List
Mfg. Model Description Class Comments Endpoint
Type
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
W75AL
AL-175
AT-175
ALC-175
AT-210
AL-225 Canada only Residential
AL-250
AR-250
AC-250
AM-250
AL-310
AL-350
AT-350
AL-425
AC-630
5B 225 Aluminum case Residential
Residential
Residential
Residential
Residential
Residential
Residential
Residential
Residential
Residential
Residential
Residential
Residential
Residential
Residential
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
Endpoint
Part No.
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
ERG-5000-001
ERG-5002-001
Elster American/
35B Iron case Commercial
100G ERG-5000-007
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
60B Iron case Commercial
80B Iron case Commercial
250B Iron case Commercial
500B Iron case Commercial
AL800
Commercial
Must have front reading
index.
Aluminum case meters
only
100G
100G
100G
100G
100G
ERG-5000-007
ERG-5000-007
ERG-5000-007
ERG-5000-007
ERG-5000-007
100G Datalogging Installation G uide - Direct Mount 3
Chapter 1 100G Datalogging Gas Endpoint
Mfg. Model Description Class Comments Endpoint
Type
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Elster American/
Canadian
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
AL1000
AL1400
AL2300
AL3000
AL5000
R-175 11-tooth Residential
R-200 11-tooth Residential
RT-200 11-tooth Residential
RC-225
RT-230 11-tooth Residential
11-tooth
(Canada only)
Commercial
Commercial
Commercial
Commercial
Commercial
Residential
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
Aluminum case meters
only
24- and 30-tooth gears
are not compatible.
100G
100G
100G
100G
100G
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
Endpoint
Part No.
ERG-5000-007
ERG-5000-007
ERG-5000-007
ERG-5000-007
ERG-5000-007
ERG-5000-002
ERG-5002-002
ERG-5000-002
ERG-5002-002
ERG-5000-002
ERG-5002-002
ERG-5000-002
ERG-5002-002
ERG-5000-002
ERG-5002-002
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
R-275 11-tooth Residential
RT-275 11-tooth Residential
R-315 11-tooth Residential
250 11-tooth Residential
310 11-tooth Residential
S-110 11-tooth Residential
S-200 11-tooth Residential
175-S 18-tooth Residential
RT-100 18-tooth Residential
S-190 18-tooth Residential
24- and 30-tooth gears
are not compatible.
24- and 30-tooth gears
are not compatible.
24- and 30-tooth gears
are not compatible.
24- and 30-tooth gears
are not compatible.
24- and 30-tooth gears
are not compatible
24- and 30-tooth gears
are not compatible.
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
ERG-5000-002
ERG-5002-002
ERG-5000-002
ERG-5002-002
ERG-5000-002
ERG-5002-002
ERG-5000-002
ERG-5002-002
ERG-5000-002
ERG-5002-002
ERG-5000-002
ERG-5002-002
ERG-5000-002
ERG-5002-002
ERG-5000-004
ERG-5002-004
ERG-5000-004
ERG-5002-004
ERG-5000-004
ERG-5002-004
4 100G Datalogging Installation Guide - Direct Mount
Meter Compatibility List
Mfg. Model Description Class Comments Endpoint
Type
Sensus/Invensys/
S-120 11-tooth Residential
Equimeter/Rockwell
Sensus/Invensys/
T-120 11-tooth Residential
Equimeter/Rockwell
Sensus/Invensys/
T-110 11-tooth Residential
Equimeter/Rockwell
R-415 18-tooth Residential
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
RT-360 18-tooth Residential
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
Equimeter/Rockwell
Sensus/Invensys/
MR8
(R-275
Metric)
MR12
(R-415
Metric)
750
Equimeter/Rockwell
Sensus/Invensys/
1000
Equimeter/Rockwell
Sensus/Invensys/
1600
Equimeter/Rockwell
Sensus/Invensys/
3000
Equimeter/Rockwell
Sensus/Invensys/
5000
Equimeter/Rockwell
Sensus/Invensys/
10000
Equimeter/Rockwell
National/ Lancaster 175
National/ Lancaster U175 UL175
National/ Lancaster 250
Itron/Actaris/
175 3-hole index box Residential
Schlumberger/
Sprague
Itron/Actaris/
175 WC 3-hole index box Residential
Schlumberger/
Sprague
16-tooth Residential
16-tooth Residential
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Residential
Residential
Residential
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
Older meters may have
endpoint-to-meter
mounting hole variations
that can make them
100G
100G Datalogging
incompatible.
100G
100G Datalogging
100G
100G Datalogging
100G
100G Datalogging
Vertical index only
Vertical index only
Vertical index only
Actaris/Schlumberger/
100G ERG-5000-008
100G ERG-5000-008
100G ERG-5000-008
100G ERG-5000-008
100G ERG-5000-008
100G ERG-5000-008
100G ERG-5000-006
Sprague direct-read
(odometer) indexes
cannot be used.
Actaris/Schlumberger/
100G ERG-5000-006
Sprague direct-read
(odometer) indexes
cannot be used.
Actaris/Schlumberger/
100G ERG-5000-006
Sprague direct-read
(odometer) indexes
cannot be used.
Index boxes with 3
mounting holes 100G ERG-5000-005
Index boxes with 3
mounting holes
100G ERG-5000-005
Endpoint
Part No.
ERG-5000-002
ERG-5002-002
ERG-5000-002
ERG-5002-002
ERG-5000-002
ERG-5002-002
ERG-5000-004
ERG-5002-004
ERG-5000-004
ERG-5002-004
ERG-5000-003
ERG-5002-003
ERG-5000-003
ERG-5002-003
100G Datalogging Installation G uide - Direct Mount 5
Chapter 1 100G Datalogging Gas Endpoint
Mfg. Model Description Class Comments Endpoint
Type
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
Itron/Actaris/
Schlumberger/
Sprague
175
Combination
3-hole index box
Integrated
regulator
210
240
Canadian
Version of 250
240
Combination
240
240
Integrated
regulator
1-hole cover flat
face
240 2-hole cover Residential
250
250 WC
250
Combination
Integrated
regulator
1A Flat face
Includes 3-dial,
2cf indexes.
METRIS 250
3-hole index box
Slant-faced
305
Combination
Integrated
regulator
400 Slant-faced Residential
400A Slant-faced Residential
675A Top-mount index Commercial
800A Top-mount index Commercial
Residential
Residential
Residential
Residential
Residential
Residential
Residential
Residential
Residential
Residential
Residential
Residential
Index boxes with 3
mounting holes
Requires Itron 1A
Adapter P/N
CFG-0015-001 Kit
Requires Itron 1A adapter
kit, CFG-0015-001
Index boxes with 3
mounting holes
Requires Itron/Actaris
adapter p/n 80005901-00
pu
rchase from
1;
Itron/Actaris
Requires Itron/Actaris
adapter p/n 80005901-001;
purchase from
Itron/Actaris
100G ERG-5000-005
100G ERG-5000-005
100G ERG-5000-005
100G ERG-5000-005
100G ERG-5000-005
100G
100G ERG-5000-005
100G ERG-5000-005
100G ERG-5000-005
100G ERG-5000-005
100G ERG-5000-005 +
100G ERG-5000-005
100G ERG-5000-005
100G ERG-5000-005
100G ERG-5000-005
100G ERG-5000-007
100G ERG-5000-007
Endpoint
Part No.
ERG-5000-005
+ CFG-0015-001
CFG-0015-001
6 100G Datalogging Installation Guide - Direct Mount
Meter Compatibility List
Mfg. Model Description Class Comments Endpoint
Type
Itron/Actaris/
1000A Top-mount index Commercial
Schlumberger/
Sprague
EMCO #2 ½
EMCO #3
EMCO #4
EMCO #4 ½
EMCO #5
Dresser ROOTS
Series B3
8C - 56M
8C - 16M
CTR
TC
(No pulser, No
instrument drive)
Dresser ROOTS
Dresser ROOTS
Series A1
(LMMA)
1.5M - 5M
Series A1
(LMMA)
7M - 16M
CTR
(No pulser, No
instrument drive)
CTR
(No pulser
No instrument
drive)
Dresser ROOTS
Dresser ROOTS 5C/8C15
Series A1
(LMMA)
1.5M - 16M
TC
(No pulser
No instrument
drive)
Series Z compact
meter
Dresser ROOTS B3/LMMA Instrument drive
CD/TD
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Commercial
Requires Itron/Actaris
adapter p/n 80005901-00
pu
rchase from
Itron/Actaris
To attach an Elster
American endpoint,
install Dresser's Elster
American AMR adapter
kit.
To attach an Elster
American endpoint,
install Dresser's Elster
American AMR adapter
kit.
To attach an Elster
American endpoint,
install Dresser's Elster
American adapter kit.
To attach an Elster
American endpoint,
install Dresser's Elster
American AMR adapter
kit.
To attach an Elster
American endpoint,
install Dresser's Elster
American adapter kit.
100G Datalogging Installation G uide - Direct Mount 7
Chapter 1 100G Datalogging Gas Endpoint
Installation Prerequisites
Prior to installation, verify you have the following items:
1. 100G Datalogging Gas Endpoints designed for your specific brand of residential or
commercial gas meters (endpoints include new tamper seals).
2. A compatible meter (see the Meter Compatibility List on page 2).
3. A compatible index. Itron 100G Datalogging Gas Endpoints are compatible with
standard dial and direct-read (odometer) indexes. Exceptions are noted on the Meter
Compatibility List on page 2.
4. Installation tools (provided by installer or customer)
• Small and medium flat-blade or Phillips screwdrivers - to remove and tighten
index and index-cover screws.
• Side-cutting plier/wire snips - to cut wire seals, if applicable.
• Small putty knife - residential meters.
• Meter seals, wire seal, and seal press - to protect the meter from tampering, if
applicable.
• 11/32-inch nut driver or other blunt tool - to securely seat new tamper plugs
over screw holes.
®
• FC200SR handheld computer with Endpoint-Link
or EndPoint-Link Pro®
software - to program and check 100G Datalogging Gas Endpoint installation
and operation.
Caution The 100G Datalogging Gas Endpoints can only be programmed using
FC200SR Handheld Computers loaded with EndPoint-Link
software version 5.3 or later.
®
or EndPoint-Link Pro
®
8 100G Datalogging Installation Guide - Direct Mount
Installation Prerequisites
Endpoint on the meter:
Endpoint housing:
• Replacement screws - to mount the 100G Datalogging Gas Endpoint assembly
to the meter and the index to the endpoint housing:
Replacement Screws
Meter To mount the 100G
Datalogging Gas
Itron Part
Number
To mount the index on the
100G Datalogging Gas
Itron Part
Number
Elster American 1/4 - 20 x 5/8" slotted,
Fillister head
Sensus/Rockwell 10 - 24 x 5/8" slotted
Fillister head
Itron/Actaris 10 - 24 x 5/8" slotted
Fillister head
National/Lancaster 10 - 24 x 3/4" Phillips flat-
head stainless steel
Commercial
Meter
To mount the 100G
Datalogging
Commercial endpoint
on the meter:
Elster American 2A x 3.25" length, slotted
round-head drilled to accept
utility-approved wire seals
Sensus/Rockwell 2A x 3.63" length, slotted
round-head drilled to accept
utility-approved wire seals
8 - 32 x 3/16" slotted, round
pan-head
6 - 32 x 5/8" slotted, round
pan-head
10 - 24 x 1/4" slotted, round
pan-head
SCR-0014-004 6 - 19 x 3/8" thread-forming,
Phillips pan-head to mount
indexes with legs
6 - 19 x 3/8" thread-forming,
Phillips, Fillister head to
mount indexes with screw
holes
Itron Part
Number
To mount the index (and
index assembly, if
applicable) on the 100G
Datalogging Comme rc ial
endpoint housing:
SCR-0062-001
(Elster American)
12 - 24 x 1/2" slotted, Fillister
head machine screws, drilled
to accept utility-approved wire
seals
SCR-0062-002 2A x 2.94" length, slotted
round-head
SCR-0015-001
SCR-0037-001
Itron Part
Number
SCR-0062-003
100G Datalogging Installation G uide - Direct Mount 9
Chapter 1 100G Datalogging Gas Endpoint
10 100G Datalogging Installation G uide - Direct Mount
C
2
HAPTER
Elster American Meter Installation
This chapter provides instructions to install the 100G Datalogging Gas Endpoint on an
Elster American Meter.
Installing the 100G Datalogging Gas Endpoint involves four tasks:
1. Removing the index from the meter.
2. Assembling the 100G Datalogging Gas Endpoint and index.
3. Programming the 100G Datalogging Gas Endpoint assembly.
4. Attaching the 100G Datalogging Gas Endpoint assembly to the meter.
Note Properly dispose all unused screws, old index covers, gaskets, tamper seals,
and other leftover materials. Do not leave materials on customer premises.
To remove the index from the meter
1. Remove the four index cover screws and the index cover from the Elster American
meter. Alternate screw removal following the numbered pattern in the photo.
100G Datalogging Installation G uide - Direct Mount 11
Chapter 2 Elster American Meter Installation
2. Examine the mounting screws. If they are 5/8" long and not corroded, keep them to re-
attach the 100G Datalogging Gas Endpoint assembly. If the screws are not the correct
length or if the screws are corroded, discard.
Note You may use the removed index cover as a temporary storage container for
screws. Properly dispose all unused screws, old index covers, gaskets, tamper
seals, and other leftover materials. Do not leave materials on customer premises.
3. Unscrew one index mounting screw completely. Hold one hand under the index to
catch the screw. While removing the other mounting screw, pull the index away from
the meter to keep the index backplate against the back of the screw. Remove the screw
completely after the index is free of the meter.
Set the index aside where it will not be damaged or fill with dirt, rain or snow. The
index will be mounted to the endpoint later in this procedure. Verify the index
mounting screws are 3/16" long and not corroded. If the screws are the correct length
and not corroded, retain for later use. If the original screws were discarded, use the
correct replacement screws (see Installation Prerequisites on page 8.)
4. Remove the old gasket, gasket residue and dirt from the meter (if applicable). The
meter face must be free of gasket residue before you install the 100G Datalogging Gas
Endpoint.
12 100G Datalogging Installation G uide - Direct Mount
Installation Prerequisites
To Assemble the 100G Datalogging Gas Endpoint and Index
1. Separate the 100G Datalogging Gas Endpoint housing from the cover by pulling the
cover straight out from the housing.
2. Set the endpoint cover aside where it will not be damaged or fill with rain, dirt or
snow. The cover will be used later in this installation procedure.
100G Datalogging Installation G uide - Direct Mount 13
Chapter 2 Elster American Meter Installation
Note Elster American meter indexes are available in different models:
Index wrigglers on one-foot meters
with drive slots
Index meters on two-foot meters
with drive posts
An Elster American index with
mounting screw holes
An Elster American index with
mounting slots
If your index has mounting screw slots, skip steps 3 and 4. If your index has mounting
screw holes, perform steps 3 and 4, and skip steps 5 and 6.
3. Using the original index mounting screw or a replacement screw, if necessary, place
one 8 - 32 3/16" screw into the index's right-hand mounting screw hole.
14 100G Datalogging Installation Guide - Direct Mount
Installation Prerequisites
4. Attach the screw to the endpoint housing's right-index mounting post just enough to
hold the screw and the right end of the index in place.
5. Screw one 8 - 32 x 3/16" screw into the right index mounting post one or two turns.
Do not tighten the screw.
6. Place the right index mounting screw slot under the screw head. Do not tighten the
screw.
7.Slide the index drive post into the endpoint wriggler. Verify positive engagement.
Caution If the index wriggler has a drive slot, place the endpoint wriggler's drive
post into the index drive slot. Failure to mate the endpoint wriggler with the index
drive post (or slot) can cause binding and lead to poor registration or meter failure.
8. Install and tighten the left index mounting screw (for indexes with either mounting
screw slots or holes). Tighten the right index mounting screw.
100G Datalogging Installation G uide - Direct Mount 15
Chapter 2 Elster American Meter Installation
9. Slide the endpoint cover over the index and housing. Verify the cover is installed
correctly. The endpoint label should be clearly visible and easily read.
Programming the 100G Datalogging Gas Endpoint Assembly
The 100G Datalogging Gas Endpoint must be programmed with the FC200SR
handheld computer loaded with EndPoint-Link
5.3 or later. See the Endpoint-Link v5.3 (or later) Endpoint Programming Guide
(TDC-0744) for more complete programming information.
®
or Point-Link Pro® software version
Caution The 100G Datalogging Gas Endpoint must be programmed before use.
Follow the steps in this section to properly program the endpoint.
16 100G Datalogging Installation G uide - Direct Mount
Programming the 100G Datalogging Gas Endpoint Assembly
The endpoint is programmed based on the meter's drive rate. Take note of the index drive
rate shown on a lower left dial on the index. The endpoint is programmed based on the drive
rate. Elster American meter index drive rates are either 1-cubic foot or 2-cubic feet.
To Program the 100G Datalogging Gas Endpoint
1. Program the meter drive rate into the 100G Datalogging Gas Endpoint using the
FC200SR. For all programming and "Check Endpoint" operations, hold the FC200SR
as close to vertical as possible. For best success, keep the FC200SR within 6 feet of
the target endpoint. Verify you have the correct programming mode (Fixed Network
Mode, Mobile/Handheld Mode, or Hard to Read Mobile/Handheld Mode) for your
application. Programming parameters are based on the mode defined by your system
administrator.
During programming, the 100G Datalogging Gas Endpoint is set to the nearest 100
cubic feet; the last two digits (tens and units) are programmed as zeros (0). After
programming is complete, the endpoint assembly will read to the nearest cubic foot.
2. Slowly turn the endpoint's drive wriggler two turns in the direction shown on the
index drive rate. This verifies the endpoint is counting properly after assembly.
Caution Do not turn the drive wriggler faster than one turn per second.
3.Read the 100G Datalogging Gas Endpoint using the FC200SR.
• If the read result is higher than the number programmed in Step 1, the 100G
Datalogging Gas Endpoint is counting correctly.
• If the read result is not higher than the number programmed in Step 1, replace
the 100G Datalogging Gas Endpoint.
100G Datalogging Installation G uide - Direct Mount 17
Chapter 2 Elster American Meter Installation
Attaching the 100G Datalogging Gas Endpoint Assembly to
the Elster American Meter
After 100G Datalogging Gas Endpoint programming is complete, attach the endpoint
assembly to the Elster American Meter.
Warning For 5B Meters only: If the 100G Datalogging Gas Endpoint
will be installed on a 5B-225 aluminum meter, cut 1/16" off each
endpoint wriggler post to prevent the wriggler from rubbing on the face
of the nut holding the meter drive dog in place.
To Attach the 100G Datalogging Gas Endpoint
1. Align the endpoint wriggler to connect with the drive post (or slot) of the meter.
For one-foot meters: Align the endpoint assembly wriggler perpendicular to the meter
drive post.
For two-foot meters: Align the endpoint assembly wriggler perpendicular to the meter
drive slot. The pin on the endpoint wriggler may be installed inside or outside the
meter drive slot. For easy assembly, Itron recommends installing the pin on the 100G
Datalogging Gas Endpoint wriggler outside the meter drive slot.
18 100G Datalogging Installation G uide - Direct Mount
Attaching the 100G Datalogging Gas Endpoint Assembly to the E
lster American Meter
2. Carefully align the endpoint's four screw holes with the holes on the meter. Attach
using the original mounting screws if they are the correct size and are not corroded
(1/4 - 20 x 5/8" screws.) If the original screws were discarded, use the correct
replacement screws (see Installation Prerequisites on page 8). Tighten in an
alternating, diagonal pattern as shown in the photo:
• Insert first screw and tighten 1/4 to 1/2 turn after the screw contacts the meter
connection.
• Insert the second screw and tighten 1/4 to 1/2 turn after contact with the meter
connection.
• Insert the third screw and tighten 1/4 to 1/2 turn after contact with the meter
connection.
• Insert the last screw and tighten 1/4 to 1/2 turn after contact with the meter
connection.
Return to the first screw and tighten. Continue with the second, third and last screw
until all screws are tight. Use equal screw tension to tighten each screw.
Note Meter manufacturers should torque the mounting screws 15 to 20 inch-
pounds.
3. Place new tamper seals over the two screws with tamper seal mounts. Press tamper
seals into place using the 11/32" nut driver or similar blunt tool.
100G Datalogging Installation G uide - Direct Mount 19
Chapter 2 Elster American Meter Installation
4. Complete necessary paperwork and verify all excess materials are removed from the
customer's premises. 100G Datalogging Gas Endpoint installation on the Elster
American meter is complete.
20 100G Datalogging Installation G uide - Direct Mount