Itron 100GDLAS, 100GDLCS, 100GDLBS Users Manual

Natural Gas Solutions
100G DLS Gas ERT Module Installation
Guide, Direct Mount
TDC-0823-009
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount ii Proprietary and Confidential
Identification
Compliance Statement
This equipment complies with policies RSS-210 and RSS-GEN of the Industry Canada rules. Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
Déclaration de conformité Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
Warning Follow these procedures to avoid injury to yourself or others:
The lithium battery may cause a fire or chemical burn if it is not disposed of properly.  Do not recharge, disassemble, heat above 100º Celsius (212º Fahrenheit), crush, expose to water, or
incinerate the lithium battery. Fire, explosion, and severe burn hazard.
Keep the lithium battery away from children.  Replace the lithium battery only with batteries meeting Itron specifications. Any other battery may
cause a fire or explosion.
Warning Only authorized Itron personnel should attempt repairs on Itron equipment. Attempts to do so by others might void any maintenance contract with your company. Unauthorized service personnel might also be subject to shock hazard on some Itron equipment if removal of protective covers is attempted.
Warning To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing.
Warning Substitution of components may impair intrinsic safety.
100G DLS Gas ERT Module Installation Guide, Direct Mount 17 April 2012 TDC-0823-009 100G, 100G DL, 100G DLN, 100G DLS ERT module part numbers: 100G ERT: ERG-5000-001, ERG-5000-002, ERG-5000-003, ERG-5000-004, ERG-5000-005, ERG-5000-006, ERG-5000-007, ERG-5000-008 100G Datalogging ERT: ERG-5002-001, ERG-5002-002, ERG-5002-003, ERG-5002-004, ERG-5002-005, ERG-5002-006, ERG-5002-007, ERG-5002-008 100G Datalogging FN ERT: ERG-5003-001, ERG-5003-002, ERG-5003-003, ERG-5003-004, ERG-5003-005, ERG-5003-006, ERG-5003-007, ERG-5003-008, ERG-5003-009 100G DLS ERT: ERG-5006-001, ERG-5006-002, ERG-5006-003, ERG-5006-004, ERG-5006-005, ERG-5006-006, ERG-5006-007, ERG-5006-008, ERG-5006-009 Copyright © 2010 - 2012 Itron, Inc. All rights reserved. Confidentiality Notice The information contained herein is proprietary and confidential and is provided subject to the condition that (i) it is held in confidence except to the extent required otherwise by law and (ii) it is used only for the purposes described herein. Any third party given access to this information is similarly bound in writing. Trademark Notice Itron is a registered trademark of Itron, Inc. All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.
Applicable Patents U.S. Patent Numbers: 4,614,945; 4,753,169; 4,768,903; 4,799,059; 4,867,700 Canadian Patent Numbers: 1,254,949; 1,267,936; 1,282,118 Compliance Statement This device complies with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmfu l interference in a residential installation. Operation is subject to the following two conditions:
This device may not cause harmful interference. This device must accept any interference that may cause undesirable operation.
This device must be permanently mounted such that it retains a distance of 20 centimeters (7.9 inches) from all persons in order to comply with FCC RF exposure levels. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the F CC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the eq uipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio or TV technician for help.
Transportation Classification The Federal Aviation Administration prohibits operating transmitters and receivers on all commercial aircraft. When powered, any 100G series gas ERT is considered an operating transmitter and receiver and cannot be shipped by air. All product returns must be shipped by ground transportation. Modifications and Repairs To ensure system performance, this device and antenna shall not be changed or modified without the expressed approval of Itron. Any unauthorized modificati on will void the user's authority to operate the equipment. Meter Installation/Removal In the event of malfunction, all repairs should be performed by Itron. It is the responsibility of users requiring service to report the need for service to Itron.
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount iii Proprietary and Confidential
Suggestions If you have comments or suggestions on how we may improve this documentation, send them to TechnicalCommunicationsManager@itron.com If you have questions or comments about the software or hardware product, contact Itron Technical Support: Contact
Internet: www.itron.com E-mail: support@itron.com Phone: 1 877 487 6602
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount iv Proprietary and Confidential
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount v Proprietary and Confidential
Before You Begin ........................................................................................................ vii
Contents
Document Conventions ..................................................................................................................... vii
Document Purpose ............................................................................................................................ vii
Chapter 1 About the 100G DLS Gas ERT Module ...................................................... 1
Transmission Modes ........................................................................................................................... 1
100G DLS Gas ERT Module Security ................................................................................................. 2
Enabling 100G DLS Gas ERT Module Security ................................................................................. 2
100G Series Gas ERT Specifications ................................................................................................. 2
Related Documents ............................................................................................................................ 3
100G Series Gas ERT Meter Compatibility List .................................................................................. 3
Installation Prerequisites ................................................................................................................... 12
Installation Overview ......................................................................................................................... 13
Chapter 2 Elster American Meter Installation .......................................................... 14
Removing the Meter Index ................................................................................................................ 14
Assembling the ERT Module and Index ............................................................................................ 15
Programming the 100G DLS Gas ERT Module Assembly ............................................................... 18
Attaching the 100G DLS Gas ERT Module Assembly to the Meter .................................................. 19
Chapter 3 Sensus (Invensys, Equimeter, Rockwell) Meter Installation ................. 22
Removing the Meter Index ................................................................................................................ 22
Assembling the ERT Module and Index ............................................................................................ 23
Programming the 100G DLS Gas ERT Module Assembly ............................................................... 26
Attaching the 100G DLS gas ERT module Assembly to the Sensus Meter ..................................... 27
Chapter 4 Itron (Sprague) Meter Installation ............................................................ 29
Removing the Meter Index ................................................................................................................ 29
Assembling the ERT Module and Index ............................................................................................ 30
Programming the 100G DLS Gas ERT Module Assembly ............................................................... 32
Attaching the 100G DLS Gas ERT Module Assembly to the Meter ................................................. 33
Attaching the 100G DLS Gas ERT Module Assembly to Flat-faced Sprague Meters ...................... 37
Securing Brass Meter Tags to Flat-faced Meters.............................................................................. 38
Attaching the 100G DLS Gas ERT Assembly on Sprague 175RM Meters ...................................... 40
Removing the Meter Index ................................................................................................................ 40
Assembling the ERT Module and Index ........................................................................................... 41
Programming the 100G DLS Gas ERT Module Assembly ............................................................... 44
Attaching the 100G DLS Gas ERT Module to the Sprague 175RM Meter ....................................... 45
Contents
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount vi Proprietary and Confidential
Chapter 5 National (Lancaster) Meter Installation ................................................... 48
Removing the Meter Index ................................................................................................................ 48
Assembling the ERT Module and Index ............................................................................................ 49
Programming the 100G DLS Gas ERT Module Assembly ............................................................... 53
Attaching the 100G DLS Gas ERT Module Assembly to the Meter .................................................. 54
Chapter 6 Elster American and Itron (Actaris) Commercial Meter Installation ..... 57
Removing the Index or Index Assembly from the Meter ................................................................... 57
Programming the 100G DLS Gas ERT Module ................................................................................ 60
Attaching the 100G DLS Gas ERT Module to the Commercial Meter .............................................. 61
Installing the Commercial 100G DLS Gas ERT Module on an Itron (Actaris) Commercial Meter .... 65
Programming the 100G DLS Commercial Gas ERT ......................................................................... 68
Attaching the 100G DLS Gas ERT Module to the Commercial Meter .............................................. 69
Chapter 7 Sensus (Rockwell) Commercial Meter Installation ................................. 74
Removing the Index or Index Assembly from the Meter ................................................................... 74
Programming the 100G DLS gas ERT module ................................................................................. 76
Attaching the 100G DLS Gas ERT Module to a Sensus/Rockwell Commercial Diaphram Meter .... 77
Mounting a 100G DLS Gas ERT Module on a Rockwell 750 meter with an Aluminum Box
Direct Reading (VDR) ........................................................................................................................ 80
Attaching the 100G DLS Gas ERT Module to a Sensus/Rockwell Commercial Diaphram Meter .... 81
Chapter 8 GE Oil & Gas Dresser Commercial Rotary Meter Installation ............... 84
Installation Prerequisites ................................................................................................................... 84
Installation Examples ........................................................................................................................ 85
Programming the 100G DLS Assembly ............................................................................................ 86
B3, LMMA, and S3A CTR/TC Dresser Series Register Settings and Direct Drive Programming
Information......................................................................................................................................... 88
B3, LMMA and S3A CTR/TC Meter Drive Rates: Residential Direct Drive Programming* .............. 89
Installing the Residential 100G DLS ERT Module Assembly to the Dresser Rotary Meter .............. 90
Installing the Commercial Gas ERT on a Dresser Rotary Meter with an Instrument Drive .............. 91
Programming the 100G DLS Commercial Gas ERT Module Assembly ........................................... 92
B3, LMMA, and S3A CD/TD Dresser ROOTS® Series Meter Drive Rates ...................................... 94
Completed Installation Examples ..................................................................................................... 98
Index ............................................................................................................................. 99
Before You Begin
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount vii Proprietary and Confidential
Document Conventions
Caution A Caution warns the installer that failure to follow the information in the note could result in
loss of data. Be sure to carefully read a Caution note and follow the advice or instructions.
Warning A Warning alerts the installer about potential physical harm to the installer or hardware. It is critical that you pay strict attention to Warning notes, read the information carefully, and follow the advice or instructions.
Before You Begin
Tip A Tip provides the installer with extra hints or suggestions to make a task easier to perform or a
concept easier to understand.
Note A Note supplies generic information to the installer. The installer can ignore the information
and continue a task without suffering any adverse consequences.
The following documentation conventions are used in this installation guide:
Document Purpose
This installation guide provides step-by-step instructions for installing the 100G series gas ERT module on a wide variety of meters. This installation guide may refer to the 100G series as the 100G DLS gas ERT module based on form or meter type. Mechanical installation procedures are identical for all modules. 100G series gas ERT module compatible meters are listed in the Meter Compatibility List.
Before You Begin
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount viii Proprietary and Confidential
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount 1 Proprietary and Confidential
Itron 100G DLS gas ERT modules are radio-frequency (RF) devices designed to transmit meter data to an RF
C H A P T E R 1
About the 100G DLS Gas ERT Module
meter reading device within transmission distance of the ERT module. The 100G gas ERT was designed with a higher output power than earlier Itron gas ERT modules to achieve an increased RF transmission distance. The 100G series gas ERT modules have greater output power to meet Itron mobile and fixed network requirements. The first 100G gas ERT module offered high transmit power capability which increased operational efficiency and reduced infrastructure costs. The 100G Datalogging gas ERT module was enhanced to offer higher transmit power with data logging capability (time-stamped hourly interval data) for both mobile and fixed network applications. Itron's 100G Datalogging Fixed Network (DLN) gas ERT module added improved network performance through a higher transmit power, accomplished using increased antenna efficiency and more robust optimized messaging structures. Itron's 100G DLS gas ERT module continues a legacy of increased efficiency in messaging and adds network security.
Transmission Modes
The 100G DLS gas ERT module can be set to transmit in Fixed Network, Mobile and Handheld, or Hard to Read Mobile and Handheld Mode.
Fixed Network Mode. The 100G DLS transmits a high-powered network interval message (NIM) RF
message every five minutes. Output power in this mode is 500 milliwatts or +27 dBm. Interspersed in the high power NIM, the 100G DLS transmits a medium power RF message at 10 milliwatts or +10 dBm every 60 seconds; expected battery life is 20 years.
Mobile High Power Mode. The 100G DLS transmits a high-powered RF message every 60 seconds.
Output power in this mode is 250 milliwatts or +24dbm; expected battery life is 20 years.
Mobile and Handheld Mode. The 100G DLS transmits a medium-powered RF message every 15
seconds. Output power in this mode is 10 milliwatts or +10dBm; expected battery life is 20 years.
(Optional) Hard to Read Mobile and Handheld Mode. The 100G DLS transmits a high-powered RF
message every 30 seconds. Output power in this mode is 250 milliwatts or +24dBm; expected battery life
decreases to 15 years in this mode. The Hard to Read Mobile and Handheld Mode should only be used for
exceptionally hard-to-read applications (such as meters installed on roof tops or in sub-basements).
An FCC license is not required to read 100G series gas ERT modules.
About the 100G DLS Gas ERT Module
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount 2 Proprietary and Confidential
100G DLS Gas ERT Module Security
Functional Specifications
Description
Power Source
100G
100G Datalogging 100G Datalogging FN
100G DLS
Two "A" cell lithium batteries
One "A" cell lithium battery
Tamper Detection
Tilt tamper and magnetic tamper
FCC Compliance
Part 15 certified
Industry Canada Compliance
RSS-210 certified
Intrinsically Safe per
UL Class I, Division 1, Groups C and D
Product Identification
Numeric and bar coded ERT type and serial number
Construction Materials
Gray polycarbonate housing and back plate with encapsulated electronics
The 100G DLS is a component of a ChoiceConnect system. ChoiceConnect system security applies to the RF communications between the handheld computer, Mobile Collector, or Fixed Network system and the ERT module. There are two fundamental security processes used in the ChoiceConnect system to ensure confidentiality and validity of the system communications.
Authentication. Authentication is the process of confirming that an artifact is genuine or valid.
Authentication in the 100G DLS is the process of verifying a request is from a valid source and in its original form.
Encryption. Encryption is the process of transforming information to make it unreadable to anyone who
does not have a valid security key. There are two types of encryption, symmetric and asymmetric. Symmetric encryption uses a shared key to decrypt or encrypt information. Asymmetric encryption uses a private key to encrypt and a public key to decrypt.
As a component of the Itron ChoiceConnect solution, the 100G DLS supports the security model found in the ChoiceConnect solution for both reading and programming. If the 100G DLS modules are shipped without ChoiceConnect security enabled, the utility can, at a later date, inject security key sets into the 100G DLS ERT modules.
Enabling 100G DLS Gas ERT Module Security
When 100G DLS ERT modules ship from an Itron factory, each module contains a Utility Factory key. The presence of this Utility Factory key does not enable security. The installer must enable security by injecting keys into the 100G DLS using an Itron programming device and programming commands. Initial key
exchange commands are secured using the Utility Factory key. For more information, see the Field Deployment Manager Endpoint Tools Mobile Application Guide (TDC-0934) programming guide.
100G Series Gas ERT Specifications
About the 100G DLS Gas ERT Module
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount 3 Proprietary and Confidential
Operational Specifications
Description
Operating Temperatures
-40° to 158° F (-40° to +70° C)
Operating Humidity
5 to 95 percent relative humidity
Program Frequency
908 MHz
Transmit Frequency
Spread spectrum 908 to 924 MHz ISM band
Data Integrity
Verified in every data message
Document Title
Document Part Number
Gas Module Meter Compatibility List
PUB-0117-002
Gas Module Ordering Guide
PUB-0117-001
100G DLS Gas ERT Specification Sheet
Publication 100941SP-XX
100G DLS Gas ERT Installation Guide, Remote Mount
TDC-0824-XXX
Field Deployment Manager Endpoint Tools Mobile Application Guide
TDC-0934-XXX
Field Deployment Manager Field Representative's Guide
TDC-0936-XXX
100W and 100G ERT Tamper Reference Guide
TDC-1028-XXX
Elster American (Canadian)
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Gas Module Notes
W75AL
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
AC-175
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
AL-175
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
ALC-175
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
Related Documents
Note The last three digits of the user and installation guides represent the document's revision level. The
revision level is subject to change without notice.
100G Series Gas ERT Module Meter Compatibility List
The following table lists meter types compatible with 100G series gas ERT modules. Due to continuous research and product improvements and enhancements, Itron reserves the right to change product or system specifications without notice.
About the 100G DLS Gas ERT Module
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount 4 Proprietary and Confidential
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Gas Module Notes
AT-175
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
AT-210
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
AL-225
Aluminum case, Canada only
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
5B-225
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
Must cut 1/16" off the end of the module wriggler drive post which will make the module incompatible with other 2-ft. drive meters.
10 Metric B
Originally manufactured by Metric Metal Works
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
ERT module with 2.5' cable
AC-250
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
AL-250
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
AM-250
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
AR-250
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
AT-250
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
AL-350
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
AL-425
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
AC-630
Aluminum case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
About the 100G DLS Gas ERT Module
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount 5 Proprietary and Confidential
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Gas Module Notes
AL800
Top mount index
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007
AL1000
Top mount index
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
AL1400
Top mount index
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007
AL2300
Top mount index
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007
AL3000
Top mount index
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007
AL5000
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007
35B
Iron case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007
60B
Iron case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007
80B
Iron case, must have front-reading index
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007
250B
Iron case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007
500B
Iron case
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007
RPM Rotary
CTR, TC (No pulser, no instrument drive) Use Elster American kit numbers 93179K002, 003, 004, or 005 to modify the meter with an adapter to attach the residential module.
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-003 ERG-5002-003 ERG-5003-003 ERG-5006-003
About the 100G DLS Gas ERT Module
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount 6 Proprietary and Confidential
GE Oil & Gas/Dresser Meters (ROOTS)
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Gas Module Notes
Series B3 8C—56M CTR 8C—16M TC (No pulser, No instrument drive)
To attach an Elster American AMR adapter kit, install Dresser AMR adapter kit, P/N 059599-000.
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
Series A (LMMA)
1.5M—5M CTR (No pulser, No instrument drive)
To attach an Elster American AMR adapter kit, install Dresser AMR adapter kit, P/N 058530-610.
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
Series A (LMMA) 7M—16M CTR (No pulser, No instrument drive)
To attach an Elster American AMR adapter kit, install Dresser AMR adapter kit, P/N 058531-610.
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
Series A (LMMA)
1.5M—5M TC (No pulser, No instrument drive)
To attach an Elster American AMR adapter kit, install Dresser AMR adapter kit, P/N 058224-610.
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
Series Z 5C/8C15
To attach an Elster American Dresser AMR adapter kit, install Dresser AMR adapter kit, P/N 059224-847
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-001 ERG-5002-001 ERG-5003-001 ERG-5006-001
Instrument drive B3: CTR TC, 8C—11M LMMA: CTR TC: 1.5M—11M
Instrument platform with mechanical drive.
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-007 ERG-5002-007 ERG-5003-007 ERG-5006-007 ERG-5000-008 ERG-5002-008 ERG-5003-008 ERG-5006-008
Itron (Actaris, Schlumberger, Sprague)
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Gas Module Notes
175
2-hole index cover
3-hole index cover
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005
175 Combination
3-hole index cover integrated regulator 2-hole index cover
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005
175RM
Flat-face meter regulator on back of meter
100G Datalogging FN 100G DLS
ERG-5003-009 ERG-5006-009
175WC
3-hole index cover
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-006
Requires index boxes with 3 mounting holes
About the 100G DLS Gas ERT Module
TDC-0823-009 100G DLS Gas ERT Module Installation Guide, Direct Mount 7 Proprietary and Confidential
Meter Model
Meter Notes
100G Module Type
Itron Part Number
Gas Module Notes
210 100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005
240 100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005
240
Flat-face meter 1-hole index cover
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005
Module requires Itron 1A Adapter Kit, P/N CFG-0015-001.
240
2-hole index cover
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005
240 Combination
Integrated regulator
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005
250 100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005
250WC
Integrated regulator
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005
METRIS 250
Slant-face
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005
A longer mounting screw may be required when retrofitting to some vintage METRIS meters. Longer mounting screw is Itron P/N 010626.
1A
Flat-face meter includes 3-dial, 2 cf indexes.
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005
Installation requires Itron 1A Adapter Kit, P/N CFG-0015-001.
305 Combination
Integrated regulator
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005
400
Slant-face meter
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005
400A
Slant-face meter
100G 100G Datalogging 100G Datalogging FN 100G DLS
ERG-5000-005 ERG-5002-005 ERG-5003-005 ERG-5006-005