A gap at the screw locations is normal both before and after the index cover
mounting-plate screws are tightened.
7. Install the four ERT module mounting screws and tighten them, in a diagonal
sequence. Turn each screw 1/4 to 1/2 turn after it contacts the mounting plate. If you
are using a torque wrench, tighten to 72 inch-pounds.
8. Place new tamper seals over screws and press the seals into place with an 11/32 inch
nut driver, or other blunt tool.
To attach the index and cover
1. Locate the gasket previously removed and place it on the index cover mounting plate.
2. Align the gasket screw holes with the mounting plate's screw holes.
Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters71
Chapter 6 American/Actaris Commercial Meter Installation
3. Turn the index wriggler so it will go across the ERT module wriggler when you put
the index onto the mounting plate.
4. Carefully lower the index and cover onto the mounting plate. Place the index facing
the same direction it was before you removed it.
5. Align the index cover screw holes with the screw holes in the gasket and index cover
mounting plate.
6. Verify there is no gap between the bottom of the index cover and the top of the gasket.
If there is a gap, it may be the index wriggler is riding on top of the ERT module's
upper wriggler. To eliminate a gap, repeat steps 2, 3, and 4 until the cover fits
properly.
WARNING! Do not press down on the index cover if there is a gap. If
you do, you can damage the index wriggler or ERT module wriggler.
7. Turn each screw 1/4 to 1/2 turn after it contacts the cover.
8. Place new tamper or wire seals over or through the screw heads.
9. Press tamper seals into place with an 11/32 nut driver, or other blunt tool, or crimp the
seal if you are using wire seals.
100G ERT Module installation on the American Commercial Meter is complete.
72Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters
Installing 100G ERT Module on Actaris
Installing 100G ERT Module on Actaris
The information in this section guides you through the installation of the 100G ERT Module
on Actaris 675A, 800A and 1000A meters. Installation requires an adapter kit (Actaris part
number 80005901 which must be ordered from Actaris) that contains:
One adapter plate
Four ERT mounting screws
Four screw bushings
One extension driver
To mount the index assembly to the adapter plate
1. Turn the 100G ERT Module upside down in your hand.
2. Use the other hand to place the four screw bushings into the 100G ERT Module's
screw holes. If the screw bushings become dislodged before final assembly, replace
them and repeat process.
Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters73
Chapter 6 American/Actaris Commercial Meter Installation
3. Turn the 100G ERT Module right side up and place it on the top of the commercial
meter.
4. Verify both the 100G ERT Module and meter drive dogs are lined correctly to
eliminate binding.
5. INLET lettering must be on the inlet side of the meter.
6. Place the adapter plate on top of the 100G ERT Module. The two small screw holes in
the adaptor plate must face the back of the meter.
7. Place the extension driver onto the 100G ERT Module wriggler.
74Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters
Installing 100G ERT Module on Actaris
8. Gently place the index assembly onto the adapter plate and install the two index
mounting screws.
9. Place the index cover over the index assembly. The transparent section of the cover
must be on the same side as the index dials so the meter dials can be easily read.
10. Align the four holes in the index cover with the holes located in each corner of the
adapter plate and install the long cover screws.
11. Turn each screw 1/4 to 1/2 turn after it contacts the cover.
12. Place the tamper seals into the front right and back left screw holes of the index cover.
13. Install tamper seals over the screws and press them into place with an 11/32 nut
driver, or some other blunt tool. The tamper seals should not protrude above the index
cover screw holes.
14. Complete necessary paperwork and properly dispose excess installation and scrap
materials.
Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters 75
Chapter 6 American/Actaris Commercial Meter Installation
100G ERT Module installation on the Actaris Commercial Meter is complete.
Installing 100G ERT Module on ROOTS Rotary
The information in this section guides you through the installation of the 100G ERT Module
Commercial on ROOTS rotary meters. Installation requires the following items:
One index mounting plate
Gasket and drive cover kit
100G ERT Module
A flat screwdriver
To attach the Commercial 100G ERT Module to the meter
1. Install the gasket and cover on the index mounting plate (as shown) using the two
screws included with the kit.
76Natural Gas Solutions 100G Installation Guide for Direct Mounting on Meters
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.