I-Tech RKP2415, RKP2417, RKP2419 User Manual

Page 1
User
Manual
RKP2415 / 2417 / 2419
2U 15 / 17 / 19 Rackmount
TFT LCD Monitor Keyboard Drawer
Page 2
RKP2415 / RKP2417 / RKP2419 User Manual
P.1
1. Table of Content P.1
2. Introduction P.2
3. Features P.2
4. Package Contents P.3
5. Optional Accessories P.4
6. Peripheral Products P.4
7. Important Safeguards P.5
8. Structure Diagram P.6
9. Dimension Diagram
RKP2415 P.7
RKP2417 P.8 RKP2419 P.9
10. LCD OSD Menu Operation
LCD Membrane Diagram P.10
Main Menu P.10 Sub Menu P.11-12
11. Resolution Settings
For Windows P.13
For Sun Servers P.14
12. Technical Specification P.15
1. Table Of Content
Page 3
P.2
RKP Series is a combination of keyboard, mouse and monitor into a drawer, with features such as flip-up design, adjustable brackets, built in LCD OSD to provide effective assistant for an administrator to control PC system.
RKP Series provides cost effective for your limited IT budget over using CRT and rack mounting. Also, it will be space saving for your compact environment rack and effective assistant for an administrator to control PC system.
2. Introduction
3. Features
Unique monitor flip up design allows viewing through closed glass door
of cabinet
Adjustable mounting brackets from 390 to 650mm (front to rear 19
mount)
May be fitted into 800mm deep rack by the use of extended brackets on
request
Three models to choose from 15, 17 or 19 LCD Panel
Two keyboard selections supporting multiple languages
Front-access lock for security.
Build-in slide rail and mounts easily in any 19 cabinet
Built in On Screen Display controlled by integral membrane switches.
Lightweight Aluminium construction – with black anodize finish
Disclaimer This information is subject to change without notice. The producer of this manual accepts no responsibility for damage or claims, resulting from misuse or misinterpretation
RKP2415 / RKP2417 / RKP2419 User Manual
Page 4
P.3
4. Package Contents
Before Unpacking
It is very important to locate the LCD Keyboard Drawer in a suitable environment.
The surface for placing and fixing the LCD Keyboard Drawer should be stable and level or
mounted into a suitable cabinet.
Make sure the place has good ventilation, is out of direct sunlight, away from sources of
excessive dust, dirt, heat, water, moisture and vibration.
Convenience for connecting the LCD Keyboard Drawer to the related facilities should be
well considers too.
Unpacking
The LCD keyboard drawer comes with the standard parts shown as above. Check and make sure they are included and in good condition. If anything is missing, or damage, contact the supplier immediately.
LCD Monitor1 Piece User Manual1 Piece DC Power Adapter1 Piece Power Cord1 Piece Mounting Bracket1 Pair Key for front acess lock2 Pieces Fasteners4 Pieces CD-6 3-in-1 KVM cable1 Piece
RKP2415 / RKP2417 / RKP2419 User Manual
Page 5
P.4
5. Optional Accessories
6. Peripheral Products
Model Description
CV-401 4-Port PS/2 KVM switch CV-801 8-Port PS/2 KVM switch CV-1601
16-Port PS/2 KVM switch
CV-101 CAT.5 PS/2 KVM extender
RKP2415 / RKP2417 / RKP2419 User Manual
Model Description
SUN-31 SUN / iMac USB to PS/2 adapter
Video Input 15" - 19" Touch Screen 12V / 24V / 48V DC Power Supply
Page 6
P.5
Please read all of these instructions carefully before you use the device. Save this manual for future reference.
Unplug the LCD Keyboard Drawer from the power outlet before cleaning.
Do not spray liquid cleaners or aerosol directly on the device. Wet a cloth with a
neutral detergent (e.g. clean water) and squeeze it tight, then clean the screen slightly with it.
Do not expose the LCD Keyboard Drawer directly to rain, water, moisture or
sunlight.
Avoid pressure on the LCD screen to prevent permanent damage to the display.
Do not attempt to service the device yourself. Improper operation may void your
warranty. Refer all servicing to qualified service personnel.
Safe storage environment of the LCD Keyboard Drawer is ranging between –20
o
C and 60oC. Permanent damage could occur if the LCD Keyboard Drawer is stored outside the safe range.
Unplug the LCD Keyboard Drawer immediately and call qualified service
personnel under the following conditions:
1. The VGA signal cord is frayed or damaged.
2. If the monitor has been exposed to rain, liquid or water.
3. If the monitor has been dropped or the casing has been damaged.
What the warranty does not cover
1. Any product, on which the serial number has been defaced, modified or removed.
2. Damage, deterioration or malfunction resulting from: a) Accident, misuse, neglect, fire, water, lightning, or other acts of nature,
unauthorized product modification, or failure to follow instructions supplied
with the product. b) Repair or attempted repair by anyone not authorized by us. c) Any damage of the product due to shipment. d) Removal or installation of the product. e) Causes external to the product, such as electric power fluctuation or failure. f) Use of supplies or parts not meeting our specifications. g) Normal wear and tear. h) Any other causes which does not relate to a product defect.
3. Removal, installation, and set-up service charges.
7. Important Safeguards
RKP2415 / RKP2417 / RKP2419 User Manual
Page 7
P.6
8. Structure Diagram
1, PS/2 keyboard 2, Aluminium front panel 3, Class A active matrix TFT LCD panel 4, Analog to digital signal converter board 5, Rear metal case 6, LCD inverter 7, LCD membrane 8, Ball bearing telescopic slides with stopper 9, Adjustable mounting bracket 10, Optional KVM switch
• ‚ ƒ „ … †
Š
Š
ˆ
RKP2415 / RKP2417 / RKP2419 User Manual
Page 8
RKP2415 2U 15 LCD Keyboard Drawer
9. Dimension Diagram
RKP2415 / RKP2417 / RKP2419 User Manual
P.7
Page 9
P.8
RKP2417 2U 17 LCD Keyboard Drawer
9. Dimension Diagram
RKP2415 / RKP2417 / RKP2419 User Manual
Page 10
P.9
RKP2419 2U 19 LCD Keyboard Drawer
9. Dimension Diagram
RKP2415 / RKP2417 / RKP2419 User Manual
Page 11
P.10
10. LCD OSD Menu Operation
LCD Membrane Diagram
Left
Right
Exit
Menu/Selection Power
MAIN MENU
BRIGHT/CONTRAST AUTO ADJUST PHASE/CLOCK H/V POSITION MISC RESET
Main Menu
Bright / Contrast
To enter into the Bright, Black level & Contrast sub-menu
Auto Adjust
To perform automatic optimisations of all functions
An Adjusting message is displayed during the process
Phase / Clock
To enter into the phase & clock sub menu
H/V Position
To enter into the Position sub-menu
MISC
To enter into the MISC sub-menu
Reset
Reset to the default factory settings
RKP2415 / RKP2417 / RKP2419 User Manual
Page 12
P.11
Bright / Contrast
1. Brightness
To perform brightness adjustment of the input RGB signal
Use the Left & Right button to adjust and button to Brightness
2. Contrast
To adjust the contrast level of the input signal
Use the Left & Right button to adjust and button to Contrast
Phase / Clock
1. Phase
To adjust input video sampling clocks phase
Use the Left & Right button to adjust and button to Phase
2. Clock
To adjust input video sampling clock
Use the Left & Right button to adjust and button to Clock
H/V Position
1. H.Position
To adjust the horizontal size of the frame
Use the Left & Right button to adjust and button to H.position.
2. V.Position
To adjust the vertical position of the frame
Use the Left & Right button to adjust and button to V.position.
10. LCD OSD Menu Operation
RKP2415 / RKP2417 / RKP2419 User Manual
Page 13
P.12
10. LCD OSD Menu Operation
MISC
1. Information
The first header row shows the current resolution setup
The second header row shows the horizontal frequency of the current
input signal
The third header row shows the vertical frequency of the current input
signal
2. OSD Timer
To modify the duration of the OSD time-out
3. Color a) 5500K
Select Colour Temp at 5500K
b) 6500K
Select Colour Temp at 6500K
c) 9500K
Select Colour Temp at 9500K
d) User
Change Colour Temp by manual
4. Language
To select the language of OSD menu 7 Languages :
(1) English (2) Japanese (日本語)
(3) Chinese (中文) (4) German
(5) Francais (6) Espanol (7) Italiano
RKP2415 / RKP2417 / RKP2419 User Manual
Page 14
P.13
11. Resolution Settings
For Microsoft Windows
Step 1 – Press right click on the desktop
Step 2 – Choose Properties
Step 3 – Change the Screen Resolution
Step 4 – Change the Screen refresh rate
RKP2415 / RKP2417 / RKP2419 User Manual
Page 15
P.14
11. Resolution Settings
For SUN Servers
Resolution configuration procedures should be run by qualified SUN
server administrator
Sun Servers are using resolution at 1152 x 900 x 76Hz.
Supported resolution mode for 15 LCD:
1024 x 768 x 70/75Hz
Supported resolution mode for 17 LCD:
1280 x 1024 x 75Hz
You need to change the Sun Server resolution before you connect to
LCD Display.
Please do the following procedures to change the resolution settings :
1. As root: You may find the following comment /user/sbin/m64config.
2. To view current resolution: Type /user/sbin/m64config – prconf.
3. To change to 1024x768 @ 70MHz: Type /user/sbin/m64config – res 1024x768x70 now.
4. The screen will be rubbish.
5. Then type pkill Xsun.
And Type pkill Xsession to restart the Xsession.
Under Common Desktop Environment (CDE).
To change the OpenBoot resolution, you can type the following
command in OK prompt.
1. In OK prompt, type setenv output-device screen:r1024x768x70.
2. Type printenv to confirm the resolution has been changed
to 1024x768x70Hz.
3. Then type, reset to restart the system.
Note : Remember to RESTART the server after these processes.
Note : Remember to RESTART the server after these processes.
RKP2415 / RKP2417 / RKP2419 User Manual
Page 16
P.15
Print at 8/2004
12. Technical Specification
Item
LCD Screen Manufacturer LCD Origin Panel 15 TFT17 TFT19 TFT Resolution
1,024 x 7681,280 x 1,0241,280 x 1,024
Brightness 300 cd/m2350 cd/m2500 cd/m2 Color 16.2 Million16.2 Million16.7 Million Contrast Ratio 450:01:00350:01:00500:01:00 Viewing Angle 140° x 125° 140° x 120° 170° x 170° Display Area 304 x 228 mm337 x 270 mm376 x 301 mm Pixel Pitch 0.297 mm0.264 mm0.294 mm Response Time (Tr) 15ms Response Time (Tf) 10ms
Back Light Horizontal Sync. 48.4 kHz64 ~ 80 kHz64 kHz Vertical Sync. 65 MHz60 ~ 75 Hz60 Hz Input Signal Power Management
Power Input Video Input Dimension
Weight
OSD Control
Brightness, Contract, Colour, Clock H.Position, V.Position, Phase, Scaling Auto Config., Input Select, Multi-Window Clear EEPROM, OSD adjust
RKP2415 : 11kg / 2417 : 12.5kg / 2419 : 14kg
4 x Cold Cathode Fluorescent Tube
Analog RGB 0.7Vp-p
VESA DPMS
RKP2419 : 43.9W x 8.8H x 48D cm
Description
12V DC Adapter 15-pin D-Sub Connector
RKP2415 / 2417 : 43.9W x 8.8H x 44D cm
5ms
20ms
South Korea
RKP2415 / RKP2417 / RKP2419 User Manual
LCD
*All brand names, logo registered trademarks are properties of their respective owners.
Loading...