ITech IT6723G, IT6723H, IT6724, IT6723C, IT6724B User Manual

...
Programmable HV Power
Supply
Series IT6700 User’s Manual
IT6723C/IT6723G/IT6723H/IT6724/ IT6724B/IT6724C/IT6724G/IT6724H/ IT6726B/IT6726C/IT6726G/IT6726H/ IT6726V
Version: V2.1
Statement
© Itech Electronics, Co., Ltd. 2014 No part of this manual may be reproduced in any form or by any means (including electronic stor age and retrieval or translation into a foreig n language) without prior permission and written consent from Itech Electronics, Co., Ltd. as governed by international copyright laws.
Manual Article No.
IT6700-402179
Revision
Revision 2, published on April 14, 2015 Itech Electronics, Co., Ltd.
Trademark Statement
Pentium is a registered trademark of Intel Corporation in the United States.
Microsoft, Visual Studio, Windows and MS Windows are trademarks of Microsoft Corporation in the United States and/or other countries/regions.
Guarantee
Materials in the document are provided talis qualis and may be changed in future revisions without prior notice. In addition, within the maximum allowable extent of laws, ITECH is not committed to any explicit or implied guarantee for this manual and all information therein, including but not limited to the implied guarantee on marketability and availability for some special purposes. ITECH shall not be responsible for any error or incidental or indirect losses caused by the provision, use or application of this documents and information therein. If some guarantee clauses in other written agreements between ITECH and users are not consistent with clauses herein, those clauses in other written agreements shall prevail.
Technology license
Hardware and/or software in this document cannot be provided without a license and can only be used or copied according to the license.
Restricted permission statement
Restricted permissions of the U.S. government. Permissions for software and technical data which are authorized to the U.S. Government only include those for custom provision to end users. ITECH follows FAR 12.211 (technical data), 12.212 (computer software). DFARS 252.227-7015 (technical data--commercial products) for national defense and DFARS 227.7202-3 (permissions for commercial computer software or computer software documents) while providing the customized business license s of software and technical data.
Safety Statement
“Caution” signs indicate da nger. It is required to pay attention to the contents of these signs during implementation of operations. The damage to the product or loss of important data may be caused in case of improper operation steps or failure to follow operation steps. Do not continue to implement any improper operation indicated in “Caution” signs when the specified conditions are not fully understood or these conditions are not satisfied.
“Warning” indicates danger. I t is requi r e d to pay attention to the contents of these signs during implementat ion of operation steps. Personal casualties may be caused in case of improper operation steps or failure to follow these operation steps. Do not continue to implement any improper operation indicated in “Warning” signs when the specified conditions are not fully understood or these conditions are not satisfied.
NOTE
“Instructions” ind icates oper at ion instructions. It is required to refer to the contents of these signs during operatio n steps. These signs are used for providing tips or supplementar y information for operators.
Series IT6700 User’s Manual
Copyright © It e ch Ele ct ronics Co., Ltd. i
Certification and Quality Assurance
IT6700 series power supply completely reaches n ominal technical indicators in the manual .
Warranty service
ITECH Compa ny will provi de one-year warranty services for the product materials and manufacturing (excluding the following limitations).
When warrant y service or repair is neede d, please send the product to t he
service unit specified by ITECH Company.
When the product is sent to ITECH Company for warranty service, the
customer mu st pay the one-way freight to the maintenance department of ITECH, and I TECH will be responsible for return freight.
If the product is sent to ITECH for war ranty service from other countries,
the customer will be responsible f or all the freight , duties and other taxes.
Limitation of Warranty
Warranty servi ce does not apply to the damage cau sed in the following
circumstances:
Damage resulting from cu stomer-wired circuits or customer-sup plied parts
or accessories;
Product w hich has been modified or repaired by the customer; Damage caused by the circuit installed by the cust omer or damage caused
by operation of the product in non-specified environ m ent;
The product m odel or serial number is al tered, deleted, removed or made
illegi ble by customer;
Damage caused by accidents, including but not limited to lightning, water,
fire, abuse or negligence.
Safety signs
Direct current
ON (power)
Alternating current
OFF (power)
Both direct and alternating current
Power-on state
Protective earth (ground)
terminal
Power-off state
Earth (ground) terminal
Reference terminal
Caution
Positive terminal
Warning (refer to this manual for specific Warning or Caution information)
Negati ve terminal A chassis termi nal
-
-
Series IT6700 User’s Manual
Copyright © It e ch Ele ct ronics Co., Ltd. ii
Safety Precautions
General safet y pr ecaut i ons bel ow must be f ol l owed i n each p ha se of i nstr u ment operation. In case of failure to follow these precautions or speci fic warnings in other parts of the manual , violation against the safet y standards related to the design, man ufacture and purpose of the i nstrument will occur. If the user does not foll ow these precautions, ITECH will bear no respo nsibility arising therefrom.
The power supply is provided with a three-core power cord during delivery
and should be co nnect e d to a t hr ee-cor e junct i on box . Bef or e operat i on, be sure that the power supply is well grounded.
Use electric wires of appropriate load. All loading wi res should be capable
of bearing m aximum short-circuit of electronic load without overheating.
Ensure the voltage fl uctuation of mai ns supply is less than 10% of the
working voltage range in order to reduc e risks of fire and electric shock.
To prevent burnout , please pay special attention to positive and negative
polarities of power supply during connection!
Do not use damaged equip me nt. Please check t he housing bef or e usi ng
the equipme nt. Check whether the instr um ent is subject to cracking or is lack of plastic. Do not operate the inst rument in the environment with explosive gas, steam or dust.
Observe all tags on the equipment befor e connection. Do not install alternative parts on the instrument or perform any
unauthorized modification.
Do not use the e quipment when the removable cover is dismantled or
loose.
Please use t he power adapter suppli ed by the manufacturer to avoid
accidental injury.
Do not use the e quipment on the life support system or other equipment
with safety requirement s.
If the equi pme nt is not used in the manner specified by the manufacturer,
its protection may be damaged.
Always use dry cloth to clean the equipment housing. Do not clean the
inside of t he instrument.
Do not block the air vent of the equipment .
Environmental conditions
The IT6700 series power supply can only be used indoors or in low condensation areas. The following table shows general envi ronmental requirements for thi s instrument.
Environ me ntal conditions
Requirement
Operating temperature
0°C - 40°C 0°C - 40°C
Operating humidity
20% - 80% (non condensing)
Storage tem perature
-20°C - 70 °C
Altitude
Operating up to 2,000 meters
Install ation category
II
Polluti on degree
Polluti on degree 2
Series IT6700 User’s Manual
Copyright © It e ch Ele ct ronics Co., Ltd. iii
NOTE
In order to ensure the accuracy of measurement, it is recommended to operate the instrument half an hour after start-up.
Regulation tag
The CE tag shows that the product complies
with the provisions of all relevant European laws (if the year is shown, it indicates that the year when the design is approved).
This instrument complies with the WEEE directive (2002/96/EC) tag requirements.
This attached product tag shows that the
electrical/electronic product cannot be
discarded in household waste.
This symbol indicates that no danger will
happen or toxic substances will not leak or
cause damage in normal use within the specified period. The service life of the product is 10 years. The product can be used safely within the environmental protection period; otherwise, the product should be put into the recycling system.
Waste electrical and electronic equipment (WEEE) directive
Waste electrical and electronic equipment (WEEE) directiv e,
2002/96/EC
The product complies with tag requirements of the WEEE
directive ( 2002/96/EC). This tag i ndicates that the electronic
equipment cannot be disposed of as or di nar y househ ol d w ast e.
Product Category
According to the equipment classification in Annex I of the WEEE directive, this instrument belongs to the “Monitori ng” product. If you want to return the unnecessary instrument, please contact
the nearest sales office of ITECH.
Series IT6700 User’s Manual
Copyright © It e ch Ele ct ronics Co., Ltd. iv
Compliance Information
Complies with the essential requirements of the following applicable European Directives, and carries the CE marki ng accordingly:
Electromagnetic Compat ibility (EMC) Directive 2014/30/EU Low-Voltage Directive (Safet y) 2014/35/EU
Conforms with the follow ing product sta ndards:
EMC Standard
IEC 61326-1:2012/ EN 61326-1:2013 ¹²³
Reference Standards
CISPR 11:2009+A1:2010/ EN 55011:2009+A1:2010 (Group 1, Class A)
IEC 61000-4-2:2008/ EN 61000-4-2:2009
IEC 61000-4-3:2006+A1:2007+A2:2010/ EN 61000-4-3:2006+A1:2008+A2:2010
IEC 61000-4-4:2004+A1:2010/ EN 61000-4-4:2004+A1:2010
IEC 61000-4-5:2005/ EN 61000-4-5:2006
IEC 61000-4-6:2008/ EN 61000-4-6:2009
IEC 61000-4-11:2004/ EN 61000-4-11:2004
1. The product is intended for use in non-residential/non-domestic environments. Use of the product in residential/domestic environments may cause electromagnetic interference.
2. Connection of the instrument to a test object may produce radiations beyond the specified limit.
3. Use high-performance shielded interface cable to ensure conformity with the EMC standards listed above.
Safety Standard
IEC 61010-1:2010/ EN 61010-1:2010
Series IT6700 User’s Manual
Copyri ght © It e ch Ele ct ronics Co., Ltd. v
Content
Certification and Quality Assurance ...................................................................................................................... 1
Warranty service ................................................................................................................................................... 1
Limitation of Warranty .......................................................................................................................................... 1
Safety signs ........................................................................................................................................................... 1
Safety Precautions ................................................................................................................................................ 2
Envir onmental co nditions ..................................................................................................................................... 2
Regulation tag ....................................................................................................................................................... 3
Waste electrical and electronic equipment (WEEE) directive ................................................................................ 3
Compliance Information ....................................................................................................................................... 4
Chapter I Acceptance and Installation ......................................................................................................... 1
1.1 Confirm package contents ............................................................................................................................... 1
1.2 Installation Position ......................................................................................................................................... 2
1.3 Installation of support ..................................................................................................................................... 7
1.4 Installation of power cord ............................................................................................................................... 8
Chapter II Quick Start ................................................................................................................................. 10
2.1 Brief Introduction .......................................................................................................................................... 10
2.2 Introduction of front panel ............................................................................................................................ 11
2.3 Key introduction ............................................................................................................................................ 12
2.4 VFD Indicator Description .............................................................................................................................. 13
2.5 Introduction of rear panel ............................................................................................................................. 13
2.6 Power-on selftest .......................................................................................................................................... 15
2.7 Output Checkout ........................................................................................................................................... 17
Chapter III Function and Features ................................................................................................................ 19
3.1 Switching of local/remote operation modes .................................................................................................. 19
3.2 Voltage Setup ................................................................................................................................................ 19
3.3 Current Setup ................................................................................................................................................ 19
3.4 Output On/Off Operation .............................................................................................................................. 20
3.5 Setup value/Actual value switching ............................................................................................................... 20
3.6 Voltage/Current/Power adjustment .............................................................................................................. 20
3.7 Save/recall Operation .................................................................................................................................... 20
3.8 Trigger operation ........................................................................................................................................... 21
3.9 Menu operation ............................................................................................................................................ 21
3.10 OVP function ............................................................................................................................................... 29
3.11 Key Lock function ........................................................................................................................................ 29
3.12 Remote sense function ................................................................................................................................ 29
Chapter IV Technical Specification ............................................................................................................... 31
4.1 Main technical parameters ............................................................................................................................ 31
4.2 Supplementary parameters ........................................................................................................................... 43
Chapter V Remote Operation Mode ........................................................................................................... 44
5.1 RS232 interface ............................................................................................................................................. 44
5.2 USB interface ................................................................................................................................................ 45
5.3 RS485 interface ............................................................................................................................................. 45
5.4 GPIB interface ............................................................................................................................................... 47
Appendix ................................................................................................................................................................ 48
Specifications of Red and Black Test Lines ........................................................................................................... 48
Acceptance and Installation
Copyri ght © It e ch Ele ct ronics Co., Ltd. 1
Chapter I Accept ance and Installation
Power supply is a high level safety equipment, there is a protected ground terminal.Before Installation or operation, please read the safety signs and instructions in this ma nual.
1.1 Confirm package contents
Open the package and check the articl es within packa ge box before o peration. In case of any non-conformity, missing or appearance w earing, please contact ITECH immediately.
The package box should comprise:
Device name
Quantity
Model
Remarks
Power supply
x1 IT6700 series
IT6700 series include:
IT6722/IT6722A/IT6723/ IT6723B/IT6723C/IT6723G/ IT6723H/IT6724/IT6724B/ IT6724C/IT6724G/IT6724H/ IT6726B/IT6726C/IT6726G/
IT6726H/IT6726V
Power Cord
x1
IT-E171/IT-E172/ IT-E173/IT-E174
The User may select different
power cords based on local outlet specification. For detailed specifications, refer to
1.4 Instal lation of power cord.
CD
x1
-
Comprising user manual and
documents r elated to programmi ng and grammatic
guidelines
Factory
alignment
report
x1
-
Test report before delivery Certificate of Conformity
x1
-
­USB Cable
x1
-
-
NOTE
After confirming that package contents are consistent and correct, please appropriately keep package box and related contents. The package requirements should be met when the instrument is returned to factory for repair.
Optional accessories f or IT6700 Series power supply avail able for independent sales: IT-E151 support
*IT6726 Series have no o ptional acces sories.
Acceptance and Installation
Copyri ght © It e ch Ele ct ronics Co., Ltd. 2
1.2 Installation Position
The instrument should be installed at well-ventilated and rational-sized space. Please sel ect appr opr i at e spac e f or installation based on t he p ower su ppl y size.
Model IT6722/IT6722A
Overall dimensions Width: 255 mm Height: 108.7 mm Depth: 376.37 mm
Detailed dimensional drawings
Acceptance and Installation
Copyri ght © It e ch Ele ct ronics Co., Ltd. 3
Model IT6723G/IT6723H/IT6724H
Overall dimensions Width: 255 mm Height: 108.7 mm Depth: 466.5 mm
Detailed dimensional drawings
Acceptance and Installation
Copyri ght © It e ch Ele ct ronics Co., Ltd. 4
Model IT6723/IT6723B/IT6723C/
IT6724/IT6724B/IT6724C/IT6724G
Overall dimensions Width: 255 mm Height: 108.7 mm Depth: 520 mm
Detailed dimensional drawings
Acceptance and Installation
Copyri ght © It e ch Ele ct ronics Co., Ltd. 5
Model IT6726B/IT6726G/IT6726H/IT6726V
Overall dimensions Width: 482.5 mm Height: 98.7 mm Depth: 549 mm
Detailed dimensional drawings
Acceptance and Installation
Copyri ght © It e ch Ele ct ronics Co., Ltd. 6
Model IT6726C
Overall dimensions Width: 482.5 mm Height: 98.55 mm Depth: 600.55 mm
Detailed dimensional drawings
Acceptance and Installation
Copyri ght © It e ch Ele ct ronics Co., Ltd. 7
1.3 Installation of support
IT6700 Series power can be installed on standard 19-inch support . IT-E151 is an accessor y prepared for user.
IT6726H/IT6726G/IT6726V/IT6726B/IT6726C has no accessory, each of them can be installed directly on the 19-i nch support through screw holes of the left ear.
A st andard 19-inch support can carry two sets of electronic loads. Detailed installation steps:
Installation steps:
1. Remove the power handle. Pull the handle to both side, adjust to the
vertical position of the body, and then pull the two sides with bot h hands.
2. Uncover the light-green tag on original installation of handle at both sides
of the inst rument to expose the support installation hole.
3. Detailed operation methods to install one set of load on the instrument
support: f ir stl y, fix a plastic sup por t on or i gi nal i nstal l ati on posi ti on of handl e with screw; fix t he accessor y 1 (suppor t) ; and fi nall y, install the accessor y 2 (board baffle) on the position as shown in icon below.
4. Detailed operation methods to install two sets of loads on the instrument
support: firstly, fix two plastic supports on original installation positions of handles with screws; and fix the accessory 1 (support).
Installation drawing:
Fig. 1.1 Front View for Installing One Instrument on Support
Fig. 1.2 Front View for Installing Two Instrument s on Support
Accessory 1
Accessory 2
Acceptance and Installation
Copyri ght © It e ch Ele ct ronics Co., Ltd. 8
1.4 Installation of power cord
Connect power cord of standard acc essories and ensure that the power supply is under normal power supply.
AC power input level
Worki ng volt age for IT6723/IT6723B/IT6723C/IT6723G/IT6723H is 1 10V and 220V; Working voltage for IT6722/IT6722A/IT6724/IT6724B/IT6724C/
IT6724H/IT6726H/IT6724G/IT6726G/IT6726V/IT6726B/IT6726C is 220V, so please pay attention to the working input voltage.
AC power input level:
Option Opt.01: 220VAC ± 10%, 47 to 63 Hz Option Opt.02: 110 VAC ± 10%, 47 to 63 Hz
Categories of power cords
IT6722/IT6722A/IT6723/IT6723B/IT6723C/IT6723G/IT6723H/IT6724/
IT6724C/IT6724G/IT6724H provides the standard power cords as below. Please select appropriate power cords appropriate to local voltage based
on the specifications of power cords below. If purchased model f ails to meet local voltage requi rements, please contact di stributor or factory for change.
China
IT-171
America,
Canada,Japan
IT-E172
Europe
IT-E173
Britain
IT-E174
IT6726H/IT6726G/IT6726V/IT6726B/IT6726C provides the stand ard p ow er
cords as below.
The power cords supplied with t his product is certified for safety. In case the supplied lines assembly needs to be re placed, or an extension lines must be added, be sure that it can meet the requi red power ratings of this product. A ny misuse voids the warranty of this product.
Connecting AC Input
IT6722/IT6722A/IT6723/IT6723B/IT6723C/IT6723G/IT6723H/IT6724/
IT6724C/IT6724G/IT6724H Connect standard power cord to the power supply input terminal .
IT6726H/IT6726G/IT6726V/IT6726B/IT6726C AC input connector as
E
N L
E
L N
E
N L
E
L N
Acceptance and Installation
Copyri ght © It e ch Ele ct ronics Co., Ltd. 9
follows.
In the above illustration, one end of the AC power cord is connected to the AC input terminal in the rear panel of t he pow er supply. Connect the wire, zero line and ground to the corresponding terminal of the device. Before inserti ng, please loose the screw, lock the screw when it is inserted.
Connect the three terminals red to line (L), black to neutral (N), and yellow to ground (G) on the other end of t he power cord to your AC distributi on panel.
Quick Start
Copyri ght © It e ch Ele ct ronics Co., Ltd. 10
Chapter II Quick Start
This chapter introduces the front panel, the rear panel, key f unctions and VFD display function of the power supply, make sure that you can quickly know the appearance, instruction and the key f unction before you operate t he power supply , Help you make better use of this series of power supply.
2.1 Brief Introduction
IT6700 series power supplies are hi gh perfor mance si ngle-output programmable DC power su pplied with communication interf ace. This series of programmable DC power su pply can output the maxi mu m voltage or curr ent with a fixed power for customers.IT6700 series power co mes w ith a standard communication interface RS232/USB/GPIB/RS485, both desktop and system-based features, can be designed and tested according to your needs and provide m ulti-purpose solutions.
Convenient bench-top features:
High visibility vacuum fluorescent display (VFD) Output is switch control High accuracy and high resolution Intelligent fan control, energy cons ervation, noise reduction Standard co m m unication interface RS232/USB/GPIB Output voltage and current values accor dance wit h procedure Can use the knob to adjust the voltage an d current Can adjust the knob stepping using the cursor
Model
Voltage
Current
Power
IT6722
80V
20A
400W
IT6722A
80V
20A
400W
IT6723
80V
40A
850W
IT6723B
150V
20A
850W
IT6723C
32V
110A
850W
IT6723G
600V
5A
850W
IT6723H
300V
10A
850W
IT6724
80V
40A
1500W
IT6724B
150V
20A
1500W
IT6724C
32V
110A
1500W
IT6724G
600V
5A
1500W
IT6724H
300V
10A
1500W
IT6726B
160V
40A
3000W
IT6726C
32V
220A
3000W
IT6726G
600V
10A
3000W
IT6726H
300V
20A
3000W
IT6726V
1200V
5A
3000W
*IT6722A has not standard GPIB com mu nication interface. *IT6726C has standard RS485 com mu nication interface.
Quick Start
Copyri ght © It e ch Ele ct ronics Co., Ltd. 11
2.2 Introduction of front panel
Front panel of IT6722/IT6722A/IT6723G/IT6723H/IT6724H
1. VFD screen
2. Adjusting knob
3. Compound key, the local switch key and power switch
4. Number keys and ESC
5. Function keys
6. UP,DOWN, LEFT and RIGHT key, to move cursor
7. Output terminal s
Front panel of
IT6723/IT6723B/IT6723C/IT6724/IT6724B/IT6724C/IT6724G
1. VFD screen
2. Adjusting knob
3. Compound key, the local switch key and power switch
4. Number keys and ESC
5. Function keys
6. UP,DOWN, LEFT and RIGHT key, to move cursor
7. Protective cover
8. Output terminal s
Quick Start
Copyri ght © It e ch Ele ct ronics Co., Ltd. 12
Front panel of IT6726B/IT6726C/IT6726H/IT6726G/IT6726V
1. Power switch
2. VFD screen
3. Compound key and the local swi tch key
4. Number keys and ESC
5. Function keys
6. UP,DOWN, LEFT and RIGHT key, to move cursor
7. Adjusting knob
2.3 Key introduction
Key description, see the table below:
Keys
Name and the fu nction
(Shift)
Compound keyco-work with OVPMenuSave TriggerLock
(Local)
Local switch key, switch from remote mode to local operation mode
(Power)
Power on key
0-9
Numeric keys
/OVP
Voltage set key, set the output voltage/over voltage protecti on point for the power supply
/Menu
Current set key, set the o utput current /menu fun ction key, to set the relevant Paramet ers for the power supply
/Save
Callback key to call up a set value of system parameters already stored / storage key, to save system parameter settings
Meter key, to switch from value set panel and the actual output value
/Trigger
Enter key, to confirm the number entered and operation / trigger but ton, which is used to trigger the List test.
/Lock
Output on (off) keys, control power output state / keypad lock function keys, used to lock the panel buttons
Left and right movement keys, used to set the value, to adjust the cursor to the sp ecified location
V-setV-set
I-setI-set
Recall
MeterMeter
EnterEnter
On/Off
Quick Start
Copyri ght © It e ch Ele ct ronics Co., Ltd. 13
Up and down keys, used to select a item in the menu or increase (decrease) the o ut put voltage or current values
Cancel /return keys
2.4 VFD Indicator Description
VFD indi cator function description as follow:
Char Function description Char Function description
OFF
Output is off
Timer
Output on timer function is ON
CV
The power supply is in constant vol tage mod e
Sense
No
CC
The power supply is in constant curr ent mod e
Ext
No
*
No
Adrs
USB GPIB
light when the address match or (RS232) received order
Meter
Meter mode
Rmt
The power supply is in remote mode
Shift
Use compound keys
Error
The power supply has error or
fault
OVP
OVP function state on
Prot
OVP /OTP/OCP Protection
OCP
OCP functi on state on
Lock
Key operation is locked
2.5 Introduction of rear panel
Rear panel of IT6722
1. RS232 Communication interface
2. USB Communication interface
3. GPIB Communication interface
4. Remote sense termi nal and the output terminal
5. Cooling fans
Quick Start
Copyri ght © It e ch Ele ct ronics Co., Ltd. 14
6. AC power socket
Rear panel of IT6722A
1. Remote sense termi nal and the output terminal
2. Cooling fans
3. USB Communication interface
4. RS232 Communication interface
5. AC power socket
Rear panel of IT6723/IT6723B/IT6723C/IT6723G/IT6723H/
IT6724/IT6724B/IT6724C/IT6724G/IT6724H
1. Cooling fans
2. RS232 Communication interface
3. USB Communication interface
4. GPIB Communication interface
5. Remote sense terminal and the output ter minal
6. Fuse
7. AC power socket
Rear panel of IT6726H/IT6726G/IT6726V/IT6726B
1. Cooling fans
2. RS232 Communication interface
3. USB Communication interface
4. GPIB Communication interface
5. factory using terminal
6. Fuse
Quick Start
Copyri ght © It e ch Ele ct ronics Co., Ltd. 15
7. AC power socket
8. Remote sense terminal and the output ter minal
NOTE
Above the output terminals in the rear panel of IT6726B/IT6726G/IT6726H/IT6726V has a factory using terminal, which users cannot use.
Rear panel of IT6726C
1. Cooling fans
2. RS232 Communication interface
3. USB Communication interface
4. GPIB Communication interface
5. RS485 Communication interface
6. Fuse
7. AC power socket
8. the output terminal
9. Remote sense terminal
2.6 Power-on selftest
A suc ce ssf ul sel ft est i ndi cat es that the purchased power prod uct meet s deli very standards and is available for normal usage.
Before operation, please confir m that you have fully understood the safety instructions.
To avoid burning out, be sure to confirm that power voltage matches with
supply voltage.
Be sure to con nect the main power socket to the power outlet of protective
grounding. Do not use terminal board without protective grounding. Before operation, be sure that the power suppl y is well gr ounded.
To avoid burning out, pay attention to marks of positive and n egative
polarities before wi ring.
Quick Start
Copyri ght © It e ch Ele ct ronics Co., Ltd. 16
Selftest steps
Normal selftest procedur es:
1. Correctly connect the power cord. Press Power key to start up.
2. After selftest, VFD display the output vol tage and current st atus as below:
Error Information References
The following error information may occur when an error occurs during Power On self-test:
If the EEPROM w as damaged, the VFD will display “EEPROM FAIL”. If the last power status in EEPROM is lost , then VFD will display “SYST
LOST”.
If the calibration dat a in EEPROM is lost, then VFD wil l displ ay “CAL
LOST”.
If the factory calibration data in EE PR OM is lost, and then the VFD will
display “FACT LOST”.
Exception handling
If the power supply can not start normally, please check and take measures by reference to steps below.
1. Check whether the pow er cord is correctly connected and confirm whether the power supply is powered.
Correct wiring of power cord => 2 Incorrect wiring of power cord => Re-connect the power cord and chec k
whether the exception is removed.
2. Check whether the pow er in On. Pow er key is under “ ” On status. Yes => 3 No => Please check the Power key to start power and check whet her the
exception is removed.
3. Check whether the fuse of power supply is burned out. If yes, change fuse. Detai led steps:
1) Use a screwdriver to push and turn the fuse box on the rear panel of the power supply, refer to the below picture. After the fuse box is opened, you can see the fuse in it. Please replace with a fuse of the same specification.
2) If the fuse i s fused, pl ease ch ang e fuse of same specification based on machine model. See the table blow for matching information of fuse and machine model .
OFF
0.0V 0.00A
Quick Start
Copyri ght © It e ch Ele ct ronics Co., Ltd. 17
Fuse speci fication list
Model
Fuse specif ication
220VAC)
Fuse specif ication
110VAC)
IT6722/IT6722A
5AT 250V
Does not support
110VAC input
IT6723/IT6723B/IT6723C/
IT6723H/IT6723G
15AT 250V 15AT 250V
IT6724/IT6724B/IT6724C/
IT6724H/IT6724G
15AT 250V
Does not support
110VAC input
IT6726H/IT6726G/
IT6726V/IT6726B/
IT6726C
20AT 250V
Does not support
110VAC input
3) When install, use a screwdriver to push and t urn the fuse box. Refer to the pictur e below.
NOTE
Fuse of IT6726B/IT6726C/IT6726G/IT6726H/IT6726V can unscrew directly by hand.
2.7 Output Checkout
The following procedures check to ens ure that the power supply develops its rated outputs and properly responds to operati on from the front panel.
Voltage Output Checkout
The following steps verify basic volt age functions without l oad.
1. Turn on the power supply.
2. Set the current value(≥0.01A).
3. Enable the outputs. Press key ( key will be lit) to let the CV annunciat or turn
on to light .
4. turn on Meter mode. press the M ETER key to light the button, the Meter status Mark light s on
the display is turned on.
5. Set the voltage for t he power suppl y. Set different voltage values, check the voltage value displ ayed on the VFD
is close to t he voltage value you set, and t o check if the VFD displayed current val ue is nearly zero.
6. Ensure that the vol tage can be adjusted from zero to the full rated value.
----End
Current Output ch eckout
1. Turn on the power supply.
2. Press key to ensure that the output is disabled. At the same time, the OFF status mark is on the VFD .
On/Off
On/Off
On/Off
Quick Start
Copyri ght © It e ch Ele ct ronics Co., Ltd. 18
3. Connect a short across( +) and (-) output terminals with an insulated test lead, use a wire suffi cient to handle the m aximum current.
4. Adjust the voltage value to 1V.
5. Turn on the power output. Press key to ensure the output is enabled, at the same time
there is CC status sign on th e V FD .
6. Turn on METER function key. Press METER key to light it, and the METER status sign is on the V FD.
7. Adjust the current value. Set some diff er ent cur rent val ues, che ck w het her t he vol t age val ue on VFD
is near 0v, and t he current on it is close to the value you set.
8. Make sure that the curr ent can be adju sted from 0 to full rated value.
9. Turn off the output of the power supply, and remove the short wire.
----End
On/Off
Function and Features
Copyri ght © It e ch Ele ct ronics Co., Ltd. 19
Chapter III Function and Features
This chapter will introduce the basic operation of IT6700 series power supply,including the following subdivisions:
Switching of local/remote operation modes
Voltage setup Cur r ent setup Output on/off operation S etup value/actual value switching Voltage/current/power adjustment Save/recall operation Trigger operation Me nu operation OVP protection functio n K ey l ock function Remote sense function
3.1 Switching of local/remote operation modes
Local button can enable you switch mode from remote to local mode. After you power on the power supply, the power supply’s default mode is local
mode, all the buttons can be used in thi s mode. While in remote mode, you can’t operate through fr ont panel directly except M eter and Local keys. Local and remote mode can be controlled thr ough P C. In addition, the mode changing w ill not influence the output parameters.
3.2 Voltage Setup
You can set voltage within the range of rated voltage value. When y ou press
button, the button will be lit. This indicates that you can set voltage.
There are three ways to set output volt age through front panel. The first way: press , adjust cursor location throug h
button, pressing and will enable you t o adjust the setting voltage value.
The second way : press , adjust cursor loca ti on t hrough
button, adjust rotary knob to change the setti ng voltage val ue.
The third way: press button and number key ( to ) to set
voltage value
3.3 Current Setup
You can set current within the range of rated current value. When you press
button, the button will be lit. This indicates that you can set current.
There are three ways to set output current through front panel. The first way: press ,adjust cursor location through
V-setV-set
V-setV-set
V-setV-set
V-setV-set
0
9
I-setI-set
I-setI-set
Function and Features
Copyri ght © It e ch Ele ct ronics Co., Ltd. 20
button, push and will enable you to adjust t he setting current value.
The second way: press ,adjust cursor location through
button, adjust rotary knob to change the setti ng current value.
The third way: press button and number key ( to ) to set
current value
3.4 Output On/Off Operation
button is used to control the output state of power supply. When button is lit, this indicates the output is in on mode. When output is
open, the w orking state indicator light(CV/CC) wi ll be lit.
NOTE
Make sure you have connected power supply and the test unit well, then press
button. If there is no voltage output, you should first check the voltage and
current set.
3.5 Setup value/Actual value switching
You can switch the display between setting value and actual val ue by pressing
button. When this button is lit, screen displays actual output value and the indicator light “Meter” will be lit on the VFD. In other words, when the button is not lit, the front panel displays setting val ue.
3.6 Voltage/Current/Power adjustment
The output current value is determined by output voltage of power supply and electronic load’s resistance. O nly when the actual current value is l ower than the setti ng current value, can power supply work i n C V mode and the will CV indicator light be lit.
If output current is higher than the setting val ue, then power supply will function in CC mode. And the CC indicat or light will be l it.
The output voltage and current value are also influenced by the upper limit of output pow er.
Take IT6723H (300V/10A/850W) for exampl e, suppose you set the voltage t o 100V, then the current can just reach 8.5A(limited by the power).
3.7 Save/recall Operation
Customer can save some often-used parameters in nonvolatile memor y. You can use the button (Shift) (Save) button or SCPI order *SAV
*RCL to achieve this function. Saving parameters include:
1.setti ng voltage 2.setting current 3. OVP value 4. OCP value
Saving operation:
Press (Shift)+ (save) button( button will flash), and t hen input the group number y ou want to save t hrough number key board. Pres s
button to confirm.
Recall operat ing:
Press button ( button will lit), and press corresponding gr oup
I-setI-set
I-setI-set
0
9
On/Off
On/Off
On/Off
MeterMeter
Recall
Recall
Recall
Enter
Recall
Recall
Function and Features
Copyri ght © It e ch Ele ct ronics Co., Ltd. 21
number(number1-9).At last press button to confirm.
NOTE
The memory capacity is 9*8, which indicate 8 memory groups and 9 memory in each group. The memory group you use at the present should be selected in the Menu(MEM GROUP)., refer to chapter 3.9.
IT6726G/IT6726H has 9×7 groups of memory capacities.
3.8 Trigger operation
The trigger source of IT6700 include manual and BUS, ma nual means trigger by button of t he front panel, and BUS means tr igger by command from the PC.
You need to select the trigger sour ce (TRIG) from the menu bef ore using thi s function.
After you edit a list file, press (Shift) + Triggerto give a tri gger signal. During the running process, button will flash all the time.
3.9 Menu operation
Press (Shift) + (Menu) to enter the menu . You will see a optional items on the screen, through direction keys and rotary knob to overturn VFD
display, then the screen w ill display the followi ng functions .Press button will enter corresponding items. Press button wi ll return to previous
menu. IT6722/IT6723/IT6723B/IT6723C/IT6723G/IT6723H/IT6724/IT6724B/IT6724C/
IT6724G/IT6724H/IT6726B/IT6726G/IT6726H/IT6726V power supply menu function is shown as below.
MAX VOLT
Set the max voltage output l imit
OCP SET OFF
Disable the OCP function
ON
Enable the OCP function
SYST SET
P-MEM
RESET)
Reset
Power on parameter is r estored to factory setting
Keep
Set the power -on parameter as the last power off stat e
P-OUT (OFF)
OFF
Set the power -on output state to be Offt
Keep
Set the power-on output state to be the last power-off output stat e
COMM (G P IB)
GPIB
ADDR
Address can b e set within 0-30
RS232
BAUD
4800 9600
19200
38400 57600
115.2K
NONE 8BIT
NONE 8BIT
EVEN 8BIT
ODD 8BIT
MODE
SIGNAL
MUX
Address can be set within 0-30
USB
Select USBc ommunication interface
BEEP (ON)
OFF
Disable the key sound
Enter
Enter
Enter
I-setI-set
Enter
ESC
Function and Features
Copyri ght © It e ch Ele ct ronics Co., Ltd. 22
ON
Enable the key sound
KNOB (ON)
LOCK
Lock the rotary knob function
ON
Un-lock the rotary knob funct ion
TRIG (MANUAL)
MANU
Local keyboard trigger
BUS
Trigger by command
MEM (GROUP1)
GRP1-8
Select memor y group for Sa ve and recall operation
TIMER SET
OFF
Disable the timer function
ON
Enable the timer functi on, time range 0.1-99999S
RESET
NO
keep the present settings
YES
restore the f actory setting
EXIT
Quit the men u setting
LIST SET
LI ST STATE
OFF
Set the LIST state as OFF
ON
Set the LIST state as ON
LIST LOAD
Re-load the LIST file(FILE0-FILE9)
LIST EDIT
TIME (SEC)
SEC
Second
MIN
Minute
VSET
Set the voltage for present step
ISET
Set the current for present step
SEC
Setup single step delay time (0.1-9999)
NEXT (YES)
YES
continue the edit of nex t step
NO
End up the list file edit
REPET
1-65535
Set the cycle count of list file
SAVE
NO
Un-save the current LIST file
FILE0-FILE9
Save the list file to appointed memory
EXIT
Exit the system menu
POWER INFO
MODEL ITXXXX
Unit model
VER
the software versi on
SN-1 XXXXXX
the first six number of SN
SN-2 XXXXXX
the middle six number of SN
SN-3 XXXXXX
the last si x number of SN
EXIT
Exit the i nformation menu
EXIT MENU
Exit the main menu
IT6722A power supply menu function is shown as below.
MAX VOLT
Set the max voltage output l imit
OCP SET OFF
Disable the OCP function
ON
Enable the OCP function
SYST SET
P-MEM
RESET)
Reset
Power on parameter is r estored to factory setting
Keep
Set the power -on parameter as the last power off stat e
P-OUT (OFF)
OFF
Set the power -on output state to be Offt
Keep
Set the power-on output state to be the last power-off output stat e
COMM (G P IB)
GPIB
ADDR
Address can b e set within 0-30
RS232 BAUD
4800
9600
19200 38400
Function and Features
Copyri ght © It e ch Ele ct ronics Co., Ltd. 23
57600
115.2K
NONE 8BIT
NONE 8BIT
EVEN 8BIT
ODD 8BIT
USB
Select USBc ommunication interface
BEEP (ON)
OFF
Disable the key sound
ON
Enable the key sound
KNOB (ON)
LOCK
Lock the rotary knob function
ON
Un-lock the rotary knob funct ion
TRIG (MANUAL)
MANU
Local keyboard trigger
BUS
Trigger by command
MEM (GROUP1)
GRP1-8
Select memor y group for Sa ve and recall operation
TIMER SET
OFF
Disable the timer function
ON
Enable the timer functi on, time range 0.1-99999S
RESET
NO
keep the present settings
YES
restore the f actory setting
EXIT
Quit the men u setting
LIST SET
LI ST STATE
OFF
Set the LIST state as OFF
ON
Set the LIST state as ON
LIST LOAD
Re-load the LI ST file(FILE0-FILE9)
LIST EDIT
TIME (SEC)
SEC
Second
MIN
Minute
VSET
Set the voltage for present step
ISET
Set the current for present step
SEC
Setup single step delay time (0.1-9999)
NEXT (YES)
YES
continue the edit of nex t step
NO
End up the list file edit
REPET
1-65535
Set the cycle count of list file
SAVE
NO
Un-save the current LIST file
FILE0-FILE9
Save the list file to appointed memory
EXIT
Exit the system menu
POWER INFO
MODEL ITXXXX
Unit model
VER
the softw are versi on
SN-1 XXXXXX
the first six number of SN
SN-2 XXXXXX
the middle six number of SN
SN-3 XXXXXX
the last si x number of SN
EXIT
Exit the i nformation menu
EXIT MENU
Exit the main menu
IT6726C power supply menu function is show n as below.
MAX VOLT
Set the max voltage output l imit
OCP SET OFF
Disable the OCP function
ON
Enable the OCP function
CHANG
MODE
ON
Enable the charge-mode function
OFF
Disable the charge-mode function
SYST SET
P-MEM
Reset
Power on parameter is r estored to factory setting
Function and Features
Copyri ght © It e ch Ele ct ronics Co., Ltd. 24
RESET)
Keep
Set the power -on parameter as the last power off stat e
P-OUT (OFF)
OFF
Set the power -on output state to be Offt
Keep
Set the power-on output state to be the last power-off output stat e
COMM (G P IB)
GPIB
ADDR
Address can b e set within 0-30
RS232
BAUD
4800 9600 19200 38400 57600
115.2K
NONE 8BIT
NONE 8BIT
EVEN 8BIT
ODD 8BIT
MODE
SIGNAL
MUX
Address can be set within 0-30
USB
Select USBc ommunication interface
RS485
BAUD
4800 9600 19200 38400 57600
115.2K
NONE 8BIT
NONE 8BIT EVEN 8BIT ODD 8BIT
MODE
SIGNAL MUX
Address can be set within 0-30
BEEP (ON)
OFF
Disable the key sound
ON
Enable the key sound
KNOB (ON)
LOCK
Lock the rotary knob function
ON
Un-lock the rotary knob funct ion
TRIG (MANUAL)
MANU
Local keyboard trigger
BUS
Trigger by command
MEM (GROUP1)
GRP1-8
Select memor y group for Sa ve and recall operation
TIMER SET
OFF
Disable the timer function
ON
Enable the timer functi on, time range 0.1-99999S
RESET
NO
keep the present settings
YES
restore the f actory setting
EXIT
Quit the men u setting
LIST SET
LI ST STATE
OFF
Set the LIST state as OFF
ON
Set the LIST state as ON
LIST LOAD
Re-load the LIST file(FILE0-FILE9)
LIST EDIT
TIME (SEC)
SEC
Second
MIN
Minute
Function and Features
Copyri ght © It e ch Ele ct ronics Co., Ltd. 25
VSET
Set the voltage for present step
ISET
Set the current for present step
SEC
Setup single step delay time (0.1-9999)
NEXT (YES)
YES
continue the edit of nex t step
NO
End up the list file edit
REPET
1-65535
Set the cycle count of list file
SAVE
NO
Un-save the current LIST file
FILE0-FILE9
Save the list file to appointed memory
EXIT
Exit the system menu
POWER INFO
MODEL ITXXXX
Unit model
VER
the software versi on
SN-1 XXXXXX
the first six number of SN
SN-2 XXXXXX
the middle six number of SN
SN-3 XXXXXX
the last si x number of SN
EXIT
Exit the i nformation menu
EXIT MENU
Exit the main menu
NOTE
Pressing button can enable you to quit any function setting.
Maximum voltage setM AX VOLT
The range of setting volt age is from 0V to rated voltage. You can press (Shift) + (Menu) button to enter the menu, then press key to
select >MAX VOLT item. Press button to confirm. After you set the max voltage value, the output voltage value can only be set within t he max voltage. T he defaul t max voltage val ue i s the rated value.
Over current protection set (OCP SET)
Over current protecti on feature allows the user to set an over current protect ion point, when the current in the circuit is larger than the current protection point, the power su pply will enter OCP protection. Over current protection, power output wil l be off, and accompa ni ed by the chirping of t he buz z er, the VFD mark Prot will be lit, and the emer gence of "OVER C UR R" alarm
The operation to set the OCP point:
1. Press (Shift) + Menubutton to menu.
2. Press to overturn to OCP SET, press button to confirm.
3. Press to select ONpress to confirm.
4. Set OCP point by pressing numeric keys, then press . At last,
press to escape.
Charge-mode function set (CHANG)
This functi on is used for IT6726C power to batt er y char gi ng. When ON opt i on i s selected, t he power output is turned off after co mpleting the battery charge, meanwhile the power will not reverse current, that is to say the battery will not
ESC
I-setI-set
Enter
I-setI-set
Enter
Enter
Enter
Esc
Function and Features
Copyri ght © It e ch Ele ct ronics Co., Ltd. 26
discharge. When OFF option is selected, the power will reverse current after the battery charge fi nished and the battery will discharge. The default setting is OFF option.
NOTE
In addition to providing a battery charge, IT6726C power is used for other work, please select OFF option for CHANG function.If the function is selected for CHANG ON option, when the power output is turned off, fall-time of the power becomes very long.
Only IT6726C Power contains CHANG function.
Power-on parameters set (P-MEM)
This item can set power on parameters. If you select RESET item, t hen all the parameter s will be initialized to the factory setting. Output voltage and current will always be 0V/max rated current; if set to Keep, the output value will be the same wit h last power off state. The default setting is RESET item.
Power On Output State (P-OUT)
This item can set the power on output stat e. If you sel ect KEEP item, that indicates t he power on outp ut state is t he same with output state before this item is set. If you select Off item, unit will automat ically in off mode when you power on. Default setting is Off item.
Communication (COMM)
Our unit has provided three standard communication interfaces: RS232/USB/GPIB.In this option, you can select the communication interf ace according to your demand s. The range of GPIB address is 0-30. Besides, we have multi-baudrate to be cho sen in RS232 mode---4800,9600,19200,38400,57600, 115.2K.Data bit is 8,Check digit have three choices: NONE,ODD,EVEN.Before you begin to carry out communication,please make sure the configure in our unit agrees with PC configure.
Key Sound Set (BEEP)
This item can s et the k ey sound st at e. If i n On mode, the p ow er supply will issue beeper sound when you press any button.If in Off mode,the beeper will not make a sound.The default set is in on mode.
Rotary Knob Set (KNOB)
This item is used to set rotary knob state. In On mode,you can use this rotary knob to set the output value and overturn the menu items.In Lock mode,this knob can’t be used.The default setting is in On mode.
Trigger source (TRIG)
Before you running a list file, you need a t rigger signal.Thus you must set the trigger mode first: keyboard tri gger or command trigger. In MANU trigger
mode, press (Shift)+ button can generate a trigger signal. In BUS trigger mode, you can onl y trigger through sen di ng co mmand. T he d efaul t set i s
MANU option.
Memory Group Set (MEM GROUP)
Power supply can save some often-used par ameters i n a nonvolatil e memory(capacity i s 9*8 groups).This function can m ake the operations more
Enter
Function and Features
Copyri ght © It e ch Ele ct ronics Co., Ltd. 27
conveni ent. Customer can save and recall parameter s quickly. GRP1: This indicates saving power sup ply parameters in 1-9 groups.Press
(Shift)+ (Save) and the group number ( 1-9) can save the parameters in corresponding groups.
GRP2: This indicates saving the parameters in 10-18 gr oups.Press (Shift) +
(Save)+saved group number(1-9can save related parameters.Note
that the curr ent number “ 1” represents parameters are saved in 10
th
groups.Nu m ber “2” represents the para m eters are saved in 11
th
groups. GRP3-GRP8 by parity of reasoning. Detailed Save and Recall operation refer to chapter 3.7.
NOTE
IT6726G/IT6726H has 9×7 groups of memory capacities.
Timer Set (TIMER SET)
This item is used to set the “time on- load” function, time range 0.1-99999S .In ON mode, the indicator light “Timer” will be lit on the VFD scree n.When output of power sup ply is opened, timer will begin to work, after reaching the definite time,output will be off automatically.If in OFF mode,the timer functi on will not be enabled.The default set is OFF.
Reset (RESET)
This item is used to reset all items in the menu.If you select YES, then unit w ill restored to f actory setting.If you select NO, all settings in the menu will r emain unchanged.
List (List Set)
IT6700 s er i es pow er s up pl y pr ovides 9 l i st f iles, each list fil e i ncl udes 15 0 st ep s. Before you e dit a list file, please set the trigger mo de:manual mode.
Press (Shift)+ (Menu)button to enter the menu,then press direction key to select >SYST SET option,after that please push button to
confirm.At last to press directi on key to select >Trig MANUAL and push
button to confirm.
You can make the output change order by editing ever y step value of l ist operation. The param eters you need to edit incl udes:single-step voltage,single-step curr e nt, si ngle-step delay ti me and w hether to go on the next step.Besides,you also need to set the r epeat times and save list sequence file.Af ter the editing process,at this time if a trigger signal is received,power supply wil l begin to work according to the sequence steps you’ve edit. Now we take five st eps for an example.
Operation steps:
1. Press (Shift) + Menubutt on to enter the menu.
2. VFD display >MAX VO LT,press to select > LI ST SET,press
to confir m
3. VFD display >LIST STATE,press to select >LIST EDIT, press
to confirm.
Recall
Recall
I-setI-set
Enter
Enter
I-setI-set
Enter
Enter
Function and Features
Copyri ght © It e ch Ele ct ronics Co., Ltd. 28
4. VFD display >TIME SECpress to conf irmgo to the next step,
you can also through button to select >T IME MIN time unitpress
to confirm.
5. VFD display >VSET 0.0, pres s number key to or through rotary
knob to set voltageafter that press to confirm.
6. VFD display ISET 0.00, press number ke y to or rotary knob to
set the single-step current , press to confirm.
7. VFD display SEC 0.100, press number key to or rotary knob t o
set single-step delay timepress to confirm(range is 0.1-9999). If you choose MIN for the 4
th
step, VFD will display MIN 0.100 for this step,
time range 0.1~9999min.
8. VFD display NEXT >YESpress t o confirm.
9. Repeat the steps from 5) to 8) and set the four steps’ voltage/current an d
delay time separately. When screen display NEXT>YES in the fourth step edit process, please press to select NEXT >NO,press to
confirm.
10. VFD display REPET 1press number key to or rotary knob to
set the repeat timespress to confirm.
11. VFD display SAVE >NO,press to conf i rm,i n this circumstance,
the list fil e is not saved but can r un for one time,or you can press button to select >SAVE FILE0,saving the list test file in FI LE 0~FILE9press
to confirm.You can recall the fi le in the following utilization.
12. If you do not save the list test file, VFD will display LIST EDIT;if you sel ect
to save the test file,VFD will display SAVE DONE for three seconds,and then display LIST EDITL.
Set List State
13. Press to select >LIST STATE item,press to confirm.
14. VFD display LIST >OFF, press t o select >LIST >ON, press to
confirm.Now button wi ll be lit.This indicates that list operat ion function has been opened.
15. VFD display >LIST ST ATEpressing button can quit the operation.
Run list file
16. Press button to open the outputpress (Shift)+
Trigger)to give a tr igger signal.
Recall list file
17. If you have edit ed several list files,you can select LIST LOAD item to recal l
the fil e you need. An d t hen pr es s to quit this operat i on.P ress button to open the output.Now you onl y need to press (Shift)+
(T rigger) to give a trigger signal,the list file can be ran.
Quit list file
Enter
Enter
0
9
Enter
0
9
Enter
0
9
Enter
Enter
Enter
0
9
Enter
Enter
Enter
Enter
Enter
Enter
Esc
On/Off
Enter
Esc
On/Off
Enter
Function and Features
Copyri ght © It e ch Ele ct ronics Co., Ltd. 29
18. In LIST mode,voltage set and current set button can’t be used,In LIST
STATE item,choose LIST>OFF will enable you to quit list mode.
3.10 OVP function
IT6700 series power supply provide OVP function, press (Shift)+ button can enable you to set the over voltage protect i on l evel. O ver vol tage m ay caused by internal defect or customer’s i ncorrect operation(such as output voltage ri si ng) ,or a too hi gh ex ter nal vol tage. On ce OV P funct i on i s t ri gger ed,t he output will be off immediately and “OVP” indicat or light will be lit,the VFD display “OVER VOLT”.
Avoid ex ternal volt age that across t he output terminals exceeding the 120% of rated volt age or it will dam age out power supply!
When power supply in OV P state,please check the external factors first, after you exclude the external factors, press ON/OFF butt on to open output again.If in communi cation state or iginally, you should by sending order OUTP ON order to open output.
3.11 Key Lock function
Press (Shift)+ Lockbutton to set the key lock state. If keyboard has been l ocked,the indicator light Lock will display on the VFD screen.In addition,when key board are lock,al l butttons can’t be used but ON/O F F Meter butonshift button.Press this button once again will relieve key lock function.
3.12 Remote sense function
Remote sense can adjusted at the output voltage of the device under test, this feature allows to compensate the volt age drop on the w ire between the front panel terminals of the power supply and the device under test.
Vo+, Vo- : output terminals, the same wi th front pannel output terminals; Vs+, Vs- : remote sense pins. NC, NC : No conjunction.
TriggerTrigger
V-setV-set
On/Off
Function and Features
Copyri ght © It e ch Ele ct ronics Co., Ltd. 30
Use local sense
Local sense doesn’t compensate the voltage drop on the connection w ire, the operation is:
1. Use the short cli ps on the back panel of the instrument , or install wire
between Vo+ and Vs+ Vo- and Vs-.
2. Connect the the positive and negative terminals of the front panel to the
device under test.
Use remote sense:
Disconnect the wires between “+,-”pins if you want to use remote sense function. Then lead a wi re from S+,S- pins and connect to the under test objects.
1. Disconnect the wires/short clips between Vo+ and Vs+、 Vo- and Vs-.
2. Connect wires from Vs+ Vs- to the device u sder test.
3. Connect wires from Vo+ Vo- to the device under test.
NOTE
In order to ensure the stability of the system, using armored twisted pair cable between the remote sense terminal of IT6700 and load.
Please note that the positive and negative polarity when wiring, otherwise it will damage the instrument!
Vo+ Vs+ Vs- Vo-
Technical Specification
Copyri ght © It e ch Ele ct ronics Co., Ltd. 31
Chapter IV Technical Specification
This chapter will introduce the main technical par am eters of IT6700, such as rated volt age/current/power and so on. Besides, we will introduce the working environme nt and storage temperature.
4.1 Main technical parameters
Parameters
IT6722
IT6722A
Rated val ues ( 0 °C-40 °C)
voltage
0~80V
current
0~20A
power
400W
Load regulati on
±(%of Output+Offset)
voltage
≤0.03%+5mV
current
≤0.1%+5mA
Line regulation
±(%of Output+Offset)
voltage
≤0.01%+5mV
current
≤0.1%+5mA
Setup resolut ion
voltage 10mV
current
10mA
Readback res olution
voltage
10mV
current
10mA
Setup accuracy
one year 、25°C±5°C)
±(%
of Output+Offset)
voltage ≤0.01%+10mV current ≤0.1%+10mA
Readback accuracy
one year 、25°C±5°C)
±(%of Output+Offset)
voltage ≤0.01%+20mV current ≤0.1%+20mA
Ripple
(20Hz -20MHz)
voltage ≤50mVp-p
current
≤15mArms
Setup Temp.coefficient
(%Output/°C+Offset)
voltage
0.02%+10mV
current 0.03%+10mA
Readback
Temp.coefficient
(%Output/°C+Offset)
voltage 0.02%+10mV current 0.03%+10mA
Rise tim e(No-load) voltage ≤300mS
Rise time(Full-load) voltage ≤1S
Fall time(No-load)
voltage
≤500mS
Fall time(Full-load)
voltage
≤300mS
Transient Response
Time
≤5mS
AC Input
voltage1
176V~ 264V
voltage2
/
Frequency
47Hz~63Hz
Setup stability-30min
(%
of Output +Offset)
voltage
0.01%+20mV
current 0.1%+30mA
Setup stability-8h
(%of Output +Offset
voltage
0.01%+20mV
current
0.1%+30mA
Readback
stability-30min
(%of Output +Offset
voltage
0.01%+20mV
current 0.1%+30mA
Technical Specification
Copyri ght © It e ch Ele ct ronics Co., Ltd. 32
Readback stability-8h
(%of Output +Offset
voltage
0.01%+20mV
current
0.1%+30mA
Efficiency
80%(Typical)
Fuse specif ication
5A
Remote Sense Compensation
1V
Command
Response Tim e
10-600mS
Power Factor
99%(Typical)
Maximum input current
3A
Maximum input
apparent power
500VA
Storage temperature
-10~70
Protective fun c tio n
OVP/OCP/OTP
standard Interface
USB/RS232/GPIB
USB/RS232
Isolation
(output to ground)
500V
Worki ng temperature
0~40
Dimension(mm)
214.5mmW×88.2mmH×445mmD
Weight(net)
4Kg
Parameters
IT6723
IT6724
Rated val ues ( 0 °C-40 °C)
voltage
0~80V
current
0~40A
power
850W
1500W
Load regulati on
±(%
of Output+Offset)
voltage
≤0.01%+10mV
current
≤0.1%+10mA
Line regulation
±(%of Output+Offset)
voltage
≤0.01%+10mV
current
≤0.1%+10mA
Setup resolut ion
voltage
10mV
current
10mA
Readback res olution
voltage
10mV
current
10mA
Setup accuracy
one year 、25°C±5°C)
±(%
of Output+Offset)
voltage ≤0.03%+20mV current ≤0.1%+40mA
Readback accuracy
one year 、25°C±5°C)
±(%of Output+Offset)
voltage ≤0.03%+20mV current ≤0.1%+40mA
Ripple
(20Hz -20MHz)
voltage ≤100mVp-p
current
≤50mArms
Setup Temp.coefficient
(%Output/°C+Offset)
voltage 0.02%+10mV current 0.03%+20mA
Readback
Temp.coefficient
(%Output/°C+Offset)
voltage 0.01%+10mV current 0.03%+20mA
Rise tim e(No-load) voltage ≤300mS
Rise time(Full-load)
voltage
≤500mS
Fall time(No-load)
voltage
≤5S
Fall time(Full-load)
voltage
≤150mS
Technical Specification
Copyri ght © It e ch Ele ct ronics Co., Ltd. 33
Transient Response
Time
≤500uS
AC Input
voltage1
110V±10%
220V±10%
voltage2
220V±10%
/
Frequency
47HZ-63HZ
Setup stability-30min
(%
of Output +Offset)
voltage
0.03%+20mV
current 0.1%+40mA
Setup stability-8h
(%of Output +Offset
voltage
0.03%+20mV
current
0.1%+40mA
Readback
stability-30min
(%of Output +Offset
voltage
0.03%+20mV
current 0.1%+40mA
Readback stability-8h
(%of Output +Offset
voltage
0.03%+20mV
current
0.1%+40mA
Efficiency
84%
88%
Fuse specif ication
15A
Remote Sense Compensation
1V
Command
Response Tim e
10-600mS
Power Factor
0.98
Maximum input current
10A
Maximum input
apparent power
1100VA 2000VA
Storage temperature
-10℃~70℃
Protective fun c tio n
OVP/OCP/OTP
standard Interface
GPIB/USB/RS232
Isolation
(output to ground)
500V
Working temperature
0~40
Dimension(mm)
214.5mmW×88.2mmH×445mmD
Weight(net)
6Kg
Parameters
IT6723B
IT6724B
Rated val ues ( 0 °C-40 °C)
voltage
0~150V
current
0~20A
power
850W
1500W
Load regulati on
±(%of Output+Offset)
voltage
≤0.01%+40mV
current
≤0.1%+10mA
Line regulat ion
±(%of Output+Offset)
voltage
≤0.01%+30mV
current
≤0.1%+10mA
Setup resolut ion
voltage 100mV
current
10mA
Readback res olution
voltage
100mV
current
10mA
Setup accuracy
one year 、25°C±5°C)
±(%
of Output+Offset)
voltage ≤0.03%+100mV 0.03%+100mV current ≤0.1%+20mA 0.1%+20mA
Readback accuracy
one year 、25°C±5°C)
±(%of Output+Offset)
voltage ≤0.03%+200mV 0.03%+200mV current ≤0.1%+20mA 0.1%+20mA
Technical Specification
Copyri ght © It e ch Ele ct ronics Co., Ltd. 34
Ripple
(20Hz -20MHz)
voltage ≤150mVp-p
current
≤30mArms
Setup Temp.coefficient
(%Output/°C+Offset)
voltage 0.02%+100mV 0.02%+100mV current 0.03%+20mA 0.03%+20mA
Readback
Temp.coefficient
(%Output/°C+Offset)
voltage
0.02%+100mV
0.02%+100mV
current 0.03%+20mA 0.03%+20mA
Rise tim e(No-load) voltage ≤300mS
Rise time(Full-load)
voltage
≤1S
Fall time(No-load)
voltage
≤5S
Fall time(Full-load)
voltage
≤200mS
Transient Response
Time
≤500uS
AC Input
voltage1
110V±10%
220V±10%
voltage2
220V±10%
/
Frequency
47HZ-63HZ
Setup stability-30min
(%
of Output +Offset)
voltage
0.03%+75mV
current 0.1%+20mA
Setup stability-8h
(%of Output +Offset
voltage
0.03%+75mV
current
0.1%+20mA
Readback
stability-30min
(%of Output +Offset
voltage
0.03%+75mV
current 0.1%+20mA
Readback stability-8h
(%of Output +Offset
voltage
0.03%+75mV
current
0.1%+20mA
Efficiency
84%
88%
Fuse specif ication
15A
Remote Sense Compensation
1V
Command Response
Time
10-600mS
Power Factor
0.98(Typical)
Maximum input current
10A
Maximum input
apparent power
1100VA 2000VA
Storage temperature
-10℃~70℃
Protective fun c tio n
OVP/OCP/OTP
standard Interface
GPIB/USB/RS232
Isolation
(output to ground)
500V
Worki ng temperature
0~40
Dimension(mm)
214.5mmW×88.2mmH×445mmD
Weight(net)
6Kg
Parameters
IT6723C
IT6724C
Rated val ues ( 0 °C-40 °C)
voltage
0~32V
current
0~110A
power
850W
1500W
Load regulati on
±(%of Output+Offset)
voltage
≤0.01%+5mV
current
≤0.1%+10mA
Technical Specification
Copyri ght © It e ch Ele ct ronics Co., Ltd. 35
Line regulat ion
±(%of Output+Offset)
voltage
≤0.01%+5mV
current
≤0.1%+10mA
Setup resolut ion
voltage
10mV
current
10mA
Readback res olution
voltage
10mV
current
10mA
Setup accuracy
one year 、25°C±5°C)
±(%
of Output+Offset)
voltage ≤0.03%+10mV current ≤0.1%+60mA
Readback accuracy
one year 、25°C±5°C)
±(%
of Output+Offset)
voltage ≤0.03%+20mV current ≤0.1%+60mA
Ripple
(20Hz -20MHz)
voltage ≤100mVp-p
current
≤150mArms
Setup Temp.coefficient
(%Output/°C+Offset)
voltage 0.02%+10mV current 0.03%+10mA
Readback
Temp.coefficient
(%Output/°C+Offset)
voltage
0.02%+10mV
current 0.03%+10mA
Rise tim e(No-load) voltage ≤300mS
Rise time(Full-load)
voltage
≤500mS
Fall time(No-load)
voltage
≤5S
Fall time(Full-load)
voltage
≤150mS
Transient Response
Time
≤500uS
AC Input
voltage1
110V±10%
220V±10%
voltage2
220V±10%
/
Frequency
47HZ-63HZ
Setup stability-30min
(%
of Output +Offset)
voltage
0.03%+10mV
current 0.1%+60mA
Setup stability-8h
(%of Output +Offset
voltage
0.03%+10mV
current
0.1%+60mA
Readback
stability-30min
(%of Output +Offset
voltage
0.03%+10mV
current 0.1%+60mA
Readback stability-8h
(%of Output +Offset
voltage
0.03%+10mV
current
0.1%+60mA
Efficiency
84%
88%
Fuse specif ication
15A
Remote Sense Compensation
1V
Command
Response Tim e
10-600mS
Power Factor
0.98
Maximum input current
10A
Maximum input
apparent power
1100VA 2000VA
Storage temperature
-10~70
Protective fun c tio n
OVP/OCP/OTP
standard Interface
GPIB/USB/RS232
Isolation
(output to ground)
500V
Technical Specification
Copyri ght © It e ch Ele ct ronics Co., Ltd. 36
Worki ng temperature
0~40
Dimension(mm)
214.5mmW×88.2mmH×445mmD
Weight(net)
6Kg
Parameters
IT6723G
IT6724G
Rated values ( 0 °C-40 °C)
voltage
0~600V
current
0~5A
power
850W
1500W
Load regulati on
±(%of Output+Offset)
voltage
≤0.01%+100mV
current
≤0.1%+10mA
Line regulat ion
±(%of Output+Offset)
voltage
≤0.01%+50mV
current
≤0.1%+10mA
Setup resolut ion
voltage 100mV
current
10mA
Readback res olution
voltage
100mV
current
10mA
Setup accuracy
one year 、25°C±5°C)
±(%
of Output+Offset)
voltage ≤0.03%+200mV
current ≤0.1%+20mA
Readback accuracy
one year 、25°C±5°C)
±(%of Output+Offset)
voltage ≤0.03%+200mV
current ≤0.1%+20mA
Ripple
(20Hz -20MHz)
voltage ≤300mVp-p
current
≤30mArms
Setup Temp.coefficient
(%Output/°C+Offset)
voltage 0.02%+100mV
current
0.03%+10mA
Readback
Temp.coefficient
(%Output/°C+Offset)
voltage
0.02%+100mV
current 0.03%+10mA
Rise time(No-load) voltage ≤300mS
Rise time(Full-load) voltage ≤1S
Fall time(No-load)
voltage
≤5S
Fall time(Full-load)
voltage
≤200mS
Transient Response
Time
≤500uS
AC Input
voltage1
110V±10%
220V±10%
voltage2
220V±10%
/
Frequency
47HZ-63HZ
Setup stability-30min
(%
of Output +Offset)
voltage
0.03%+200mV
current 0.1%+20mA
Setup stability-8h
(%of Output +Offset
voltage
0.03%+200mV
current
0.1%+20mA
Readback
stability-30min
(%of Output +Offset
voltage
0.03%+200mV
current 0.1%+20mA
Readback stability-8h
(%
of Output +Offset)
voltage
0.03%+200mV
current
0.1%+20mA
Efficiency
84%
88%
Fuse specif ication
15A
Technical Specification
Copyri ght © It e ch Ele ct ronics Co., Ltd. 37
Remote Sense Compensation
1V
Command
Response Tim e
10-600mS
Power Factor
0.98
Maximum input current
10A
Maximum input
apparent power
1100VA 2000VA
Storage temperature
-10~70
Protective fun c tio n
OVP/OCP/OTP
standard Interface
GPIB/USB/RS232
Isolation
(output to ground)
500V
Worki ng temperature
0~40
Dimension(mm)
214.5mmW×88.2mmH×445mmD
Weight(net)
6Kg
Parameters
IT6723H
IT6724H
Rated val ues ( 0 °C-40 °C)
voltage
0~300V
current
0~10A
power
850W
1500W
Load regulati on
±(%of Output+Offset)
voltage
≤0.01%+100mV
current
≤0.1%+10mA
Line regulat ion
±(%of Output+Offset)
voltage
≤0.01%+50mV
current
≤0.1%+10mA
Setup resolution
voltage 100mV
current
10mA
Readback res olution
voltage
100mV
current
10mA
Setup accuracy
one year 、25°C±5°C)
±(%
of Output+Offset)
voltage ≤0.03%+200mV
current ≤0.1%+20mA
Readback accuracy
one year 、25°C±5°C)
±(%of Output+Offset)
voltage ≤0.03%+200mV
current ≤0.1%+20mA
Ripple
(20Hz -20MHz)
voltage ≤250mVp-p
current
≤40mArms
Setup Temp.coefficient
(%Output/°C+Offset)
voltage 0.02%+100mV
current 0.03%+20mA
Readback
Temp.coefficient
(%Output/°C+Offset)
voltage 0.02%+100mV
current 0.03%+20mA
Rise tim e(No-load) voltage ≤300mS
Rise time(Full-load) voltage ≤1S
Fall time(No-load)
voltage
≤5S
Fall time(Full-load)
voltage
≤150mS
Transient Response
Time
≤500uS
AC Input
voltage1
110V±10%
220V±10%
voltage2
220V±10%
/
Technical Specification
Copyri ght © It e ch Ele ct ronics Co., Ltd. 38
Frequency
47HZ-63HZ
Setup stability-30min
(%
of Output +Offset)
voltage
0.03%+150mV
current 0.1%+20mA
Setup stability-8h
(%of Output +Offset
voltage
0.03%+150mV
current
0.1%+20mA
Readback
stability-30min
(%of Output +Offset
voltage
0.03%+150mV
current 0.1%+20mA
Readback stability-8h
(%of Output +Offset
voltage
0.03%+150mV
current
0.1%+20mA
Efficiency
84%
88%
Fuse specif ication
15A
Remote Sense Compensation
1V
Command
Response Tim e
10-600mS
Power Factor
0.98
Maximum input current
10A
Maximum input
apparent power
1100VA 2000VA
Storage temperature
-10℃~70℃
Protective fun c tio n
OVP/OCP/OTP
standard Interface
GPIB/USB/RS232
Isolation
(output to ground)
500V
Worki ng temperature
0~40
Dimension(mm)
214.5mmW×88.2mmH×445mmD
Weight(net)
6Kg
Parameters
IT6726B
Rated val ues ( 0 °C-40 °C)
voltage
0~160V
current
0~40A
power
3000W
Load regulati on
±(%of Output+Offset)
voltage
≤0.01%+50mV
current
≤0.1%+10mA
Line regulat ion
±(%of Output+Offset)
voltage
≤0.01%+40mV
current
≤0.1%+10mA
Setup resolut ion
voltage 100mV
current
10mA
Readback res olution
voltage
100mV
current
10mA
Setup accuracy
one year 、25°C±5°C)
±(%
of Output+Offset)
voltage ≤0.03%+200mV
current ≤0.1%+40mA
Readback accuracy
one year 、25°C±5°C)
±(%of Output+Offset)
voltage ≤0.03%+200mV
current ≤0.1%+40mA
Ripple
(20Hz -20MHz)
voltage ≤250mVp-p
current
≤50mArms
Setup Temp.coefficient voltage 0.02%+100mV
Technical Specification
Copyri ght © It e ch Ele ct ronics Co., Ltd. 39
(%Output/°C+Offset)
current 0.03%+20mA
Readback
Temp.coefficient
(%Output/°C+Offset)
voltage 0.02%+200mV
current 0.03%+20mA
Rise tim e(No-load) voltage ≤500mS
Rise time(Full-load) voltage ≤2S
Fall time(No-load)
voltage
≤10S
Fall time(Full-load)
voltage
≤400mS
Transient Response
Time
≤500uS
AC Input
voltage1
220V±10%
voltage2
/
Frequency
47HZ-63HZ
Setup stability-30min
(%
of Output +Offset)
voltage
0.03%+200mV
current 0.1%+40mA
Setup stability-8h
(%of Output +Offset
voltage
0.03%+200mV
current
0.1%+40mA
Readback
stability-30min
(%of Output +Offset
voltage
0.03%+200mV
current 0.1%+40mA
Readback stability-8h
(%of Output +Offset
voltage
0.03%+200mV
current
0.1%+40mA
Efficiency
88%
Fuse specif ication
20A
Remote Sense Compensation
1V
Command
Response Tim e
10-600mS
Power Factor
0.98
Maximum input current
18A
Maximum input
apparent power
3700VA
Storage temperature
-10~70
Protective fun c tio n
OVP/OCP/OTP
standard Interface
GPIB/USB/RS232
Isolation
(output to ground)
500V
Worki ng temperature
0~40
Dimension(mm)
482.5mmW×88.2mmH×548.9mmD
Weight(net)
16Kg
Parameters
IT6726C
Rated val ues ( 0 °C-40 °C)
voltage
0~32V
current
0~220A
power
3000W
Load regulati on
±(%of Output+Offset)
voltage
≤0.01%+50mV
current
≤0.1%+30mA
Line regulat ion
±(%
of Output+Offset)
voltage
≤0.01%+50mV
current
≤0.1%+10mA
Setup resolut ion
voltage 10mV
current
10mA
Technical Specification
Copyri ght © It e ch Ele ct ronics Co., Ltd. 40
Readback res olution
voltage
10mV
current
10mA
Setup accuracy
one year 、25°C±5°C)
±(%
of Output+Offset)
voltage ≤0.03%+30mV current ≤0.2%+100mA
Readback accuracy
one year 、25°C±5°C)
±(%
of Output+Offset)
voltage ≤0.03%+30mV current ≤0.2%+100mA
Ripple
(20Hz -20MHz)
voltage ≤200mVp-p
current
≤320mArms
Setup Temp.coefficient
(%Output/°C+Offset)
voltage 0.02%+10mV current 0.03%+20mA
Readback
Temp.coefficient
(%Output/°C+Offset)
voltage 0.02%+10mV current 0.03%+20mA
Rise tim e(No-load) voltage ≤500mS
Rise time(Full-load)
voltage
≤2S
Fall time(No-load)
voltage
≤10S
Fall time(Full-load)
voltage
≤400mS
Transient Response
Time
≤500uS
AC Input
voltage1
220V±10%
voltage2
/
Frequency
47HZ-63HZ
Setup stability-30min
(%
of Output +Offset)
voltage
0.03%+30mV
current 0.2%+60mA
Setup stability-8h
(%of Output +Offset
voltage
0.03%+30mV
current
0.2%+60mA
Readback
stability-30min
(%
of Output +Offset)
voltage
0.03%+30mV
current 0.2%+60mA
Readback stability-8h
(%of Output +Offset
voltage
0.03%+30mV
current
0.2%+60mA
Efficiency
88%
Fuse specif ication
20A
Remote Sense Compensation
1V
Command Response
Time
10-600mS
Power Factor
0.98
Maximum input current
18A
Maximum input
apparent power
3700VA
Storage temperature
-10~70
Protective fun c tio n
OVP/OCP/OTP
standard Interface
GPIB/USB/RS232
Isolation
(output to ground)
500V
Worki ng temperature
0~40
Dimension(mm)
482.5mmW×88.2mmH×548.9mmD
Weight(net)
16Kg
Technical Specification
Copyri ght © It e ch Ele ct ronics Co., Ltd. 41
Parameters
IT6726G
IT6726H
Rated val ues ( 0 °C-40 °C)
voltage
0~600V
0~300V
current
0~10A
0~20A
power
3000W
3000W
Load regulati on
±(%of Output+Offset)
voltage
≤0.01%+100mV
≤0.01%+100mV
current
≤0.1%+10mA
≤0.1%+10mA
Line regulat ion
±(%of Output+Offset)
voltage
≤0.01%+50mV
≤0.01%+50mV
current
≤0.1%+10mA
≤0.1%+10mA
Setup resolut ion
voltage 100mV 100mV
current
10mA
10mA
Readback res olution
voltage
100mV
100mV
current
10mA
10mA
Setup accuracy
one year 、25°C±5°C)
±(%
of Output+Offset)
voltage ≤0.03%+200mV ≤0.03%+200mV
current ≤0.1%+20mA ≤0.1%+30mA
Readback accuracy
one year 、25°C±5°C)
±(%
of Output+Offset)
voltage ≤0.03%+200mV ≤0.03%+200mV
current ≤0.1%+20mA ≤0.1%+30mA
Ripple
(20Hz -20MHz)
voltage ≤500mVp-p ≤300mVp-p
current
≤50mArms
≤50mArms
Setup Temp.coefficient
(%Output/°C+Offset)
voltage 0.02%+100mV 0.02%+100mV
current 0.03%+10mA 0.03%+10mA
Readback
Temp.coefficient
(%Output/°C+Offset)
voltage
0.02%+100mV
0.02%+100mV
current 0.03%+10mA 0.03%+10mA
Rise tim e(No-load) voltage ≤500mS ≤500mS
Rise time(Full-load) voltage ≤2S ≤2S
Fall time(No-load)
voltage
≤10S
≤10S
Fall time(Full-load)
voltage
≤400mS
≤400mS
Transient Response
Time
≤500uS
AC Input
voltage1
220V±10%
voltage2
/
Frequency
47HZ-63HZ
Setup stability-30min
(%
of Output +Offset)
voltage
0.03%+200mV
0.03%+200mV
current 0.1%+20mA 0.1%+30mA
Setup stability-8h
(%of Output +Offset
voltage
0.03%+200mV
0.03%+200mV
current
0.1%+20mA
0.1%+30mA
Readback
stability-30min
(%of Output +Offset
voltage
0.03%+200mV
0.03%+200mV
current 0.1%+20mA 0.1%+30mA
Readback stability-8h
(%of Output +Offset
voltage
0.03%+200mV
0.03%+200mV
current
0.1%+20mA
0.1%+30mA
Efficiency
88%
Fuse specif ication
20A
Remote Sense Compensation
1V
Command
10-600mS
Technical Specification
Copyri ght © It e ch Ele ct ronics Co., Ltd. 42
Response Tim e
Power Factor
0.98
Maximum input current
18A
Maximum input
apparent power
3700VA
Storage temperature
-10~70
Protective fun c tio n
OVP/OCP/OTP
standard Interface
GPIB/USB/RS232
Isolation
(output to ground)
500V
Worki ng temperature
0~40
Dimension(mm)
482.5mmW×88.2mmH×548.9mmD
Weight(net)
16Kg
Parameters
IT6726V
Rated val ues ( 0 °C-40 °C)
voltage
0~1200V
current
0~5A
power
3000W
Load regulati on
±(%of Output+Offset)
voltage
≤0.01%+200mV
current
≤0.1%+20mA
Line regulat ion
±(%of Output+Offset)
voltage
≤0.01%+100mV
current
≤0.1%+20mA
Setup resolut ion
voltage 100mV
current
10mA
Readback res olution
voltage
100mV
current
10mA
Setup accuracy
one year 、25°C±5°C)
±(%
of Output+Offset)
voltage ≤0.04%+200mV current ≤0.1%+20mA
Readback accuracy
one year 、25°C±5°C)
±(%of Output+Offset)
voltage ≤0.04%+200mV current ≤0.1%+20mA
Ripple
(20Hz -20MHz)
voltage ≤600mVp-p
current
≤50mArms
Setup Temp.coefficient
(%Output/°C+Offset)
voltage 0.02%+100mV current 0.03%+10mA
Readback
Temp.coefficient
(%Output/°C+Offset)
voltage 0.02%+100mV current 0.03%+10mA
Rise tim e(No-load) voltage ≤500mS
Rise time(Full-load) voltage ≤2S
Fall time(No-load)
voltage
≤10S
Fall time(Full-load)
voltage
≤400mS
Transient Response
Time
≤500uS
AC Input
voltage1
220V±10%
voltage2
/
Frequency
47HZ-63HZ
Setup stability-30min
(%
of Output +Offset)
voltage
0.04%+200mV
current 0.1%+20mA
Technical Specification
Copyri ght © It e ch Ele ct ronics Co., Ltd. 43
*The above specifications may be subject to change without prior notice.
4.2 Supplementary parameters
Memory: 9×8 groups Suggested calibration frequency: 1time/year Radiating mode :Fans
Setup stability-8h
(%of Output +Offset
voltage
0.04%+200mV
current
0.1%+20mA
Readback
stability-30min
(%of Output +Offset
voltage
0.04%+200mV
current 0.1%+20mA
Readback stability-8h
(%of Output +Offset
voltage
0.04%+200mV
current
0.1%+20mA
Efficiency
88%
Fuse specif ication
20A
Remote Sense Compensation
1V
Command
Response Tim e
10-600mS
Power Factor
0.98
Maximum input current
18A
Maximum input
apparent power
3700VA
Storage temperature
-10~70
Protective fun c tio n
OVP/OCP/OTP
standard Interface
GPIB/USB/RS232
Isolation
(output to ground)
500V
Worki ng temperature
0~40
Dimension(mm)
482.5mmW×88.2mmH×548.9mmD
Weight(net)
16Kg
Remote Operation Mode
Copyri ght © It e ch Ele ct ronics Co., Ltd. 44
Chapter V Remote Operation Mode
IT6700 series power supply is pr ovided with thr ee communication interfaces to communicate with a computer for sel ection, including S232, USB, RS485 and GPIB. IT6722A has not st andard GPIB communication interf ace.
5.1 RS232 interface
There is a D B9 connector at the rear of the power suppl y, when connect to computer, you need to select a cable wit h COM port on both si de; to active communication, you need to enable the settings in menu to be the same with the PC commu nication configuration.
NOTE
The RS232 settings must match the settings in front panel system information. If any change, please press (Shift)+ key to modify the me nu: SYST SET \COMM.
RS-232 data format
RS-232 data i s a 10-bit words which has a start bit and a stop bit. The start bit and stop bit can’t be edited. However, you can select the parity items with (Shift) + key on the front panel .
Parity options are stored in nonvolatile memory.
Baud Rate
The front panel (Shift) + button allows the user to select a baud rate which is stored i n the non-volatile memory: 4800/9600/19200/38400/57600/115200.
RS-232 connection
Use a RS232 cable with DB-9 interface, R S -232 serial port can connect with the controller (eg PC). D o not use blank Modem cable. Below Table shows t he plug pins.
If your computer is usi ng a R S -232 interface with DB-25 connector, you need an adapter cable with a DB-25 connector at one end and the other side is a DB-9(not blank mode m cabl e) .
RS232 Pins of P lug
Base pin number
Description 1
No conjunction
2
TXD, data transmission
3
RXD, data r eceiving
4
No conjunction
5
GND, grounding
6
No conjunction
7
CTS, cl ear to send
8
RTS, r equest to send
9
No conjunction
I-setI-set
I-setI-set
I-setI-set
Remote Operation Mode
Copyri ght © It e ch Ele ct ronics Co., Ltd. 45
RS-232 Troubles h o o ting:
If there is RS-232 connect ion problem, check the following: Computer and power supply must configure the sam e baud rate, parity,
data bits and f low control options. Not e that the power configuration as a start bi t and a stop bit (these values are fi xed).
As described before in RS -232 connector, you must use the c orrect
interface cable or adapter. Note that eve n i f t he cabl e ha s t he right plug, the internal w iring may be wrong.
Interface c able must be connected to the correct serial port on the
computer (C O M1, COM2, etc.).
Communication Settings
Before co m mu nication, you should fi rst make the following parameters of power supply and PC matches.
Baud Rate: 96 00 (4800/9600/19200/38400/57600/115200). You can enter the system menu from the front panel, and then set the baud rate.
Data bits: 8 Stop Bits: 1 calibration (none, eve n, odd) EVEN 8 data bits, have eve n parity ODD 8 data bits have odd parity NONE 8 data bits, no parity Local Address: (0 ~ 31, the fact ory default set ting is 0)
Parity=None Start Bit 8 Data Bits Stop Bit
5.2 USB interface
Use a Cable with two USB port to connect t he power and the co mp uter. Al l power functions can be programmed vi a US B.
The USB488 interface fun ctions of the power supply described as below:
Interface is 488.2 USB488 interface. Interface Receiver REN_C O NTROL, GO _TO_LOCAL, and
LOCAL_LOCKOUT request.
Interface Receive MsgID = TRIGGER USBTMC or der information, and will
pass TRIGGER order t o the functional layer.
Power USB488 device functions described as follows:
Devices can read all of the ma ndatory SCPI orders. Device is SR1 enabled. Device is RL1 enabled. Device is DT1 enabled.
5.3 RS485 interface
IT6726C power supply, via the RS485 interface, provides multi-unit control function f or up to 30 units ( If connecting more than 10 units, add a 120Ω resistor terminator t o the last unit as shown in the figure below). Access the menu tree Menu SYST SET COMM RS485 to set the RS485 settings.
Remote Operation Mode
Copyri ght © It e ch Ele ct ronics Co., Ltd. 46
User can set t he following parameters of the RS485 inter face:
Baud Rate: 9600(4800/9600/19200/38400/57600/115200) Parity and data bit: NONE/8BITEVEN/8BITODD/8BIT MODESIGNALMUX
SIGNALsingle-unit mode MUXmulti-unit mode), ADDR(Address),( 030the factory default setting i s 0
Start Bit 8 Data Bits Parity=None Stop Bit
To set the multi-unit connection mo de, access the menu tree MENU SYST SET COMM RS485 MODE MUX to choose the multi-unit mode.
Set each unit with a dif ferent Address (0 ~ 30). Then by using RS485 connect the first power supply in the chain to a PC. N ow, multiple units daisy-chained via RS485 can be controlled by one PC by using the commands specific for multi-unit connection. See “Programming Gui de” section for details. The following diagram shows how to connect the power supply by using RS485.
Connect to PC
Remote Operation Mode
Copyri ght © It e ch Ele ct ronics Co., Ltd. 47
5.4 GPIB interface
First, Connect the GPIB interface on the power suppl y and the GPIB car d on computer via IEEE488 bus, m ust be full access and tighten t he screws. Then set the address, the address range of the power : 0 to 30, can set by the
function key on the front p anel, press the (Shift)+ key to enter the system menu function, find the GPIB address setting by button, type the address, key to confirm. GPIB address is stor ed in nonvolati le memory
line.
I-setI-set
EnterEn ter
Appendix
Copyri ght © It e ch Ele ct ronics Co., Ltd. 48
Appendix
Specifications of Red and Black Test Lines
ITECH provides you wit h optional red and black test lines, which i ndividual sales and you can select for test. For specifications of ITECH t est lines and maximum current values, refer to the t able below.
Model
Specification
Cross section
Length
IT-E301/10A
10A
-
1m
IT-E301/30A
30A
6mm2
1.2m
IT-E301/30A
30A
6mm2
2m
IT-E301/60A
60A
20mm2
1.5m
IT-E301/120A
120A
50mm2
2m
IT-E301/240A
240A
70mm2
1m
IT-E301/240A
240A
70mm2
2m
IT-E301/360A
360A
95mm2
2m
For maxi mu m c urrent of AWG copper wire, refer to t able blow.
AWG
10
12
14
16
18
20
22
24
26
28
The
Maximum current
value( A)
40
25
20
13
10 7 5
3.5
2.5
1.7
Note: AWG ( American Wire Gage), it means X wire ( marked on the wire). The table above lists current capacity of single wire at working temperature of 30°C. For reference only.
Contact Us
Thanks for purchasing I TECH products. In case of any doubts, please contact us as follows:
1.
Refer to accompanying data disk and relevant manual.
2.
Visit ITECH website:www.itechate.com
3.
Select the most convenient co ntact method, for further information.
Loading...