ITech IT6724, IT6723, IT6723C, IT6724C, IT6700 Series User Manual

...
Via Acquanera, 29 22100 Como tel. 031.526.566 (r.a.) fax 031.507.984
info@calpower.it www.calpower.it
USER’S MANUAL
Programmable HV Power Supply
/IT6724C/IT6723B/IT6724B/IT6726B
/IT6723G/IT6724G/IT6726G/IT6726V
IT6700 User manual
Model IT6700 Series
IT6723/IT6724/IT6723C
©Copy
1
right All Rights Reserved
Ver1.1/OCT, 2012/ IT6700
User Manual
IT6700 User manual
IT6700 Series Programmable HV Power Supplies ............................................................... 3
Security .......................... ........................................... .............................................. .............. 3
Security regulation ................................................................................................................ 3
Safety symbols .......................... ................................. ................................ ........................... 3
Certification and Quality Assurance ...................................................................................... 3
Introduction ........................................................................................................................... 5
Chapter1 Inspection and Installation ........................ ................................ ................................. ....... 6
1.1 Inspection .................................................................................................................................................... 6
1.2 To Rack Mount the Instrument ................................................................................................................. 6
1.3 The size of the power supply .......................................... .............. ................... .............. ................... ....... 7
Chapter 2 Quick Start .......................................................................................................... 10
2.2 Key introduction ........................................................................................................................................ 12
2.3 VFD Indicator Description ....................................................................................................................... 13
Chapter 3 power on check .................................................................................................. 14
3.1 power on Pre-check ................................................................................................................................. 14
3.1.1 Power on the supply ..................................................................................................................... 14
3.1.2 System self-check ......................................................................................................................... 15
3.2 Output Checkout ................................................ .......................................................... ............................ 16
Chapter4 technical specification ......................................................................................... 17
4.1 main technical parameters ........................... ................... .............. ................... ................... .............. ..... 17
4.2 supplementary characteristic ..................................... ......... ............... ......... ............... ......... .............. ..... 22
Chapter5 Basic operation ................................................................................................... 23
5.1 Local/Remote Mode ..................................... ..... .......... .... .......... ..... ......... ..... .......... .... .......... ......... ..... ..... 23
5.2 Voltage Setup ............................................ ............................ .................................. ............................ ..... 23
5.3 Current Setup ....................................... ...................................... ........................................... ................... 24
5.4 Output On/Off Operation ......................................................................................................................... 24
5.5 Setup value/Actual value switching ....................................................................................................... 24
5.6 Voltage/Current/Power adjustment..................................... ........................................... ........................ 24
5.7 Save/recall Operation .............................................................................................................................. 25
5.8 Trigger operation .......... .................................................................................................... ........................ 25
5.9 Menu operation ............................... ................... ............... ................... .............. ................... .............. ..... 25
5.9.1 Menu description .................................................................................................. ..... ................... 25
5.9.2 Menu functions .............................................................................................................................. 27
5.10 OVP function ...................................... ..... ......... ..... .......... .... .......... ..... ......... .......... .... .......... ..... ..... ......... 31
5.11 Key Lock function ................................................................................................................................... 31
5.12 Remote sense function ............................................. ....................................................................... ..... 31
Chapter6 Remote Operation Mode ........ .................................................................. .. ................ 3 3
6.1 RS232 interface ........................................................................................................................................ 33
6.2 USB interface ............................................................................................................................................ 34
6.3 GPIB interface ........................................... .............................................................. ................................. 35
User Manual
2
IT6700 User manual
IT6700 Series Programmable HV Power Supplies
Security
Please do not install replacement parts in the instrument, or perform any unauthorized modification. Please send the instrument to our company's maintenance department for maintenance, to ensure its security features. Please refer to the manual for specific information warning or precautions to avoid personal injury or equipment damage. There is no part that the operator can maintenance. If maintenance service is required, please contact a trained service personnel.
Security regulation
To prevent electric shock, non-authorized personnel is strictly not allowed to open the machine. This equipment is strictly prohibited for use in life support systems or any other device with security requirements. We cannot accept responsibility for any direct or indirect financial damage or loss of profit that might occur when using the electronic load.
Safety symbols
Warning
It reminds the user, note some operating procedures, practices, conditions and other matters, that may lead to human casualties.
Notes:
It reminds the user of some operating procedures, practices, conditions and other matters that may result in instrument damage or data lose for ever.
Connect it to safety earth ground using the wire recommended in the user manual.
High voltage danger
The symbol on an instrument indicates that the user should refer to the operating
instructions located in the manual.
Certification and Quality Assurance
IT6700 series programmable DC power supply fully meet all of the technical specification in the manual.
Warranty
Our Company provide one year warranty for the materials and manufacturing of the product since the date of shipment.
3
User Manual
IT6700 User manual
Warranty Service
For the warranty service or repair the product, the product must be returned to the designated maintenance units. Return the product to us for warranty service, the customer should pre-pay the one-way Freight to the maintenance department. and our company is responsible for the return shipping cost. If products are returned from other countries for maintenance service, then the customer should pay all freight, duties and other taxes.
Guarantee limit
The guarantee does not apply to the damage caused by the following conditions: Improper or inadequate maintenance to the products by customer; Customers use their own software or interface; Unauthorized modification or misuse;
Operate this product not in the specified environment, or at the wrong place configuration and maintenance.
Damage from Customer self-installation of circuit, or defects due to customers use their products .
Product model or serial number of the fuselage has been altered, deleted, removed or made illegible;
Damage caused by accidents including but not limited to lightning, water, fire, abuse or neglect.
Notice
If the content of this manual is subject to change, we will not notice additionally
User Manual
4
IT6700 User manual
Introduction
IT6700 series power supplies are high performance single-output programmable DC power supplied with communication interface. This series of programmable DC power supply can output the maximum voltage or current with a fixed power for customers. Take IT6723H (300V/10A/850W) for example, when you select 300V for the output voltage, the output power of IT6723H is 850W , so in this case the maximum output current is 850W/300V =
2.83A. When you select 85V for the output voltage, the maximum output current 850W/85V
= 10A, but when the output voltage is down to 10V, due to IT6723H maximum current is 10A, so in this case the maximum output current is 10A. IT6700 series power comes with a standard communication interface RS232/USB/GPIB, both desktop and system-based features, can be designed and tested according to your needs and provide multi-purpose solutions.
Convenient bench-top features:
• High visibility vacuum fluorescent display (VFD)
• Output is switch control
• High accuracy and high resolution
• Intelligent fan control, energy conservation, noise reduction
• Standard communication interface RS232/USB/GPIB
Output voltage and current values accordance with procedure
• Can use the knob to adjust the voltage and current
• Can adjust the knob stepping using the cursor
Model Vol tage Current Power
IT6723 80V 40A 850W
IT6724 80V 40A 1500W
IT6723B 150V 20A 850W
IT6724B 150V 20A 1500W
IT6723H 300V 10A 850W
IT6724H 300V 10A 1500W
IT6726H 300V 20A 3000W
IT6723G 600V 5A 850W
IT6724G 600V 5A 1500W
IT6726G 600V 10A 3000W
IT6726V 1200V 5A 3000W
IT6723C 32V 110A 850W
IT6724C 32V 110A 1500W
IT6726B 160V 40A 3000W
Optional Accessories: IT-E151 rack mount kit.IT6726 not available
5
User Manual
IT6700 User manual
Chapter1 Inspection and Installation
Power supply is a high level safety equipment, there is a protected ground terminal.
Before Installation or operation, please read the safety signs and instructions in this manual
1.1 Inspection
After received the power supply, follow these steps to check it:
1. Check for damage in the equipment during transport
If it is the frame, panel damaged, or abnormal working, etc. Please contact immediately with our authorized dealer or service department. Do not return the instrument before positive response has not been got.
2. Check the attachment
Make sure you receive the power and the following components at the same time, if any missing, please contact your nearest dealer.
a power cord (in accordance with the standard voltage used in the region) an operating manual. a factory calibration report
Kinds of power cord
E
E
NL
China USA ,Canada Europe UK IT-E171 IT-E172 IT-E173 IT-E174
E
LN
E
NL
LN
3. The power input requirements
Working voltage for IT6723/IT6723B/IT6723C/IT6723H/IT6723G is 110V and 220V;Working voltageforIT6724/IT6724B/IT6724C/IT6724H/IT6724G/IT6726H/IT6726G/IT6726V/IT6726B is 220V, so please pay attention to the working input voltage. There is a power cord which matches with your local power in the attachment. If that does not match, please do not hesitate to contact with our authorized dealer or service department. AC input levels : (can choose via the switch on the bottom or power supply) Option Opt.01:220VAC ± 10%, 47 to 63 Hz Option Opt.02:110VAC ± 10%, 47 to 63 Hz
1.2 To Rack Mount the Instrument
You can mount IT6700 power supply in a standard 19-inch rack cabinet using the IT-E151 (except for IT6726H/IT6726G/IT6726V/IT6726B) rack mount kit. Method to remove the handle: Pull up carrying handle to each outside, rotate it to vertical direction and pull out.
User Manual
6
IT6700 User manual
A
A
Install method of IT-E151 Remove the carrying handle and the two pale green stickers before rack-mounting the instrument on standard 19’’ IT-E151. Mounting specification is as following: Fix a plastic fitting screwed to the original handle installation position, then fix accessories 1 and mount accessories 2 to the following icon position. The method to fix two power supplies on rack is screw two plastic fittings in original handle installation position, mount accessories 1 after that.
ccessories 1
ccessories 2
Drawing1.1 To rack mount a single instrument, order rack mount kit IT-E151
Drawing1.2 To rack mount two instruments side-by-side, order rack mount kit IT-E151, you
needn’t to use the front cover panel.
1.3 The size of the power supply
1.SizeofIT6723/IT6724/IT6723B/IT6724B/IT6723C/IT6724C/IT6723H/IT6724
H/IT6723G/IT6724G:
214.5mmW×88.2mmH×445mmD
*refer to the
Dimensions below:
7
User Manual
IT6700 User manual
Unitmm
Size of IT6726H/IT6726G/IT6726V/IT6726B: 439mmW×88.2mmH×462mmD
User Manual
8
IT6700 User manual
9
User Manual
IT6700 User manual
Chapter 2 Quick Start
This chapter introduces the front panel, the rear panel, key functions and VFD display function of the power supply, make sure that you can quickly know the appearance, instruction and the key function before you operate the power supply, Help you make better use of this series of power supply.
2.1 The front and rear panel description
FrontpanelofIT6723/IT6724/IT6723B/IT6724B/IT6723C/IT6724C/IT6723H/IT6724H/IT672
3G/IT6724G:
+ -
1
VFD display
2
Rotary knob Compound key, the local switch key and power switch
3
4
Number keys and ESC
5
Function keys
6
UPDOWN, LEFT and RIGHT key, to move cursor
7
Output terminals
User Manual
10
Front panel of IT6726H/IT6726G/IT6726V/IT6726B:
IT6700 User manual
1
Power switch
2
VFD display Compound key, the local switch key and power switch
3 4
Number keys and ESC
5
Function keys
6
UPDOWN, LEFT and RIGHT key, to move cursor
7
Rotary knob
Rear panel of IT6723/IT6724/IT6723B/IT6724B/IT6723C/IT6724C/IT6723H/IT6724H/IT67 23G/IT6724G:
1
Cooling fans
2
RS232 Communication interface
3
USB Communication interface
4
GPIB Communication interface
5
Remote sense terminal and the output terminal
6
Fuse
7
AC power socket
11
User Manual
Rear panel of IT6726H/IT6726G/IT6726V/IT6726B:
1
Cooling fans
2
RS232 Communication interface
3
USB Communication interface
4
GPIB Communication interface
5
AC power socket
6
Fuse
7
Output terminal
IT6700 User manual
2.2 Key introduction
Key description, see the table below:
Keys
Shift
Local
Power
0-9 Numeric keys
V-setV-set
I-setI-set
OVP
Menu
Name and the function
Compound keyco-work with OVP、Menu、Save、Trigger、Lock
Local switch key, switch from remote mode to local operation mode
Power on key
Voltage set key, set the output voltage/over voltage protection point for the power supply
Current set key, set the output current/menu function key, to set the
User Manual
12
relevant Parameters for the power supply
IT6700 User manual
Recall
On/Off
MeterMeter
EnterEnter
Save
Trigger
Lock
Callback key to call up a set value of system parameters already stored / storage key, to save system parameter settings
Meter key, to switch from value set panel and the actual output value Enter key, to confirm the number entered and operation / trigger
button, which is used to trigger the List test. Output on (off) keys, control power output state / keypad lock function keys, used to lock the panel buttons Left and right movement keys, used to set the value, to adjust the cursor to the specified location Up and down keys, used to select a item in the menu or increase (decrease) the output voltage or current values
Cancel /return keys
2.3 VFD Indicator Description
VFD indicator function description as follow:
Char
Function description Char Function description
OFF Output is off Timer
CV CC
* No Adrs
Meter Meter mode Rmt Shift Use compound keys Error
OVP OVP function state on Prot OVP /OTP/OCP Protection OCP OCP function state on Lock Key operation is locked
The power supply is in constant voltage mode The power supply is in constant current mode
Sense No Ext No
Output on timer function is ON
USB GPIBlight when the address match or (RS232) received order The power supply is in remote mode The power supply has error or fault
13
User Manual
IT6700 User manual
Chapter 3 power on check
This chapter will introduce the procedure of power on check, including pre-check and output check, to make sure the IT6700 series power supply can power on and work normally on the original state.
3.1 power on Pre-check
Before operate the power supply, please read the following safty guide:
WarningThe power supply is shipped from the factory with a pow er-line cord
that has a plug appropriate for your location. Your power supply is equipped with a 3-wire grounding type power cord; the third conductor being the ground. The power supply is grounded only when the power-line cord is plugged into an appropriate receptacle.
WarningUse wire with appropriately rated load capacity of all load wires must
be able to withstand the maximum short-circuit output current of the power without overheating. If there is more than one load, each load wire must be able to safely carry the power of full rated short-circuit output current.
Warning:In order to reduce the risk of fire and electric shock, make sure that the
mains supply voltage fluctuations should not exceed 10% of the operating voltage range.
Note: In some cases, misconfiguration mains voltage for the instrument may cause
the mains fuse disconnect.
NoteIf use the power supply to charge the battery, be sure to pay attention to the
battery's positive and negative polarity, otherwise it will burn out the power!
Power on pre-check includes two parts: power on the supply and system self check.
3.1.1 Power on the supply
Use the following steps to help solve problems you might encounter when turning on
the instrument.
1) Verify that there is AC power to the power supply.
First, verify that the power cord is firmly plugged into the power receptacle on the rear panel of the power supply. You should also make sure that the power source you plugged the power supply into is energized. Then, verify that the power supply is turned on.
2) Verify the power-line voltage setting.
The line voltage is set to the proper value for your country (220VAC) when the power supply is shipped from the factory. Change the voltage setting if it’s not correct.
User Manual
14
IT6700 User manual
OFF
3) Verify that the correct power-line fuse is installed.
If the fuse was damaged, please see the table below to replace the fuse for your power supply.
Model
IT6723/IT6723B/IT6723C/I
T6723H/IT6723G
Fuse Specifications220VACFuse Specifications220VAC
T15AT 250V T15AT 250V
IT6724/IT6724B/IT6724C/I
T6724H/IT6724G
IT6726H/IT6726G/IT6726V
/IT6726B
T15AT 250V Not available
T20AT 250V Not available
4) How to exchange the fuse
Open the fuse box:
Use a screwdriver to push and turn the fuse box on the rear panel of the power supply, refer to the below picture. After the fuse box is opened, you can see the fuse in it. Please replace with a fuse of the same specification.
When install, use a screwdriver to push and turn the fuse box. Refer to the picture below.
3.1.2 System self-check
After power on normally, the supply will enter self check test first.
If the power supply is normal, then VFD will display the output voltage and current status as below:
About 1 second after power onIf the EEPROM was damaged or the latest operation data in EEPROM was lost, the VFD will display as below:
If the last power status in EEPROM is lost, then VFD will display information (about 1 S) as below:
0.0V 0.00A
EEPROM FAIL
SYST LOST
15
User Manual
IT6700 User manual
If the calibration data in EEPROM is lost, then VFD will display (about 1S) as below:
If the factory calibration data in EEPROM is lost, and then the VFD will display(about 1 S) as below:
CAL LOST
FACT LOST
3.2 Output Checkout
The following procedures check to ensure that the power supply develops its rated outputs and properly responds to operation from the front panel.
3.2.1 Voltage Output Checkout
The following steps verify basic voltage functions without load.
1) Turn on the power supply.
2) Set the current value(≥0.01A).
Enable the outputs
3) Press
4) turn on Meter mode press the METER key to light the button, the Meter status Mark lights on the display is turned on.
5) Set the voltage for the power supply
Set different voltage values, check the voltage value displayed on the VFD is close to the voltage value you set, and to check if the VFD displayed current value is nearly zero.
6) Ensure that the voltage can be adjusted from zero to the full rated value
On/Off
key(
On/Off
key will be lit) to let the CV annunciator turn on to light.
3.2.2 Current Output checkout
1) Turn on the power supply
2) Press status mark is on the VFD.
3) Connect a short across(+) and (-) output terminals with an insulated test lead, use a wire sufficient to handle the maximum current.
4) Adjust the voltage value to 1V.
5) Turn on the power output.
Press status sign on the VFD.
6) Turn on METER function key.
Press METER key to light it, and the METER status sign is on the VFD.
7) Adjust the current value
Set some different current values, check whether the voltage value on VFD is near 0v, and the current on it is close to the value you set.
On/Off
On/Off
User Manual
key to ensure that the output is disabled. At the same time, the OFF
key to ensure the output is enabled, at the same time there is CC
16
IT6700 User manual
8) Make sure that the current can be adjusted from 0 to full rated value.
9) Turn off the output of the power supply, and remove the short wire.
Chapter4 technical specification
This chapter will introduce the main technical parameters of IT6700H/IT6700G,such as rated voltage/current/power and so on. Besides, we will introduce the working environment and storage temperature.
4.1 Main technical parameters
Parameters IT6723C IT6724C
Rated values
( 0 °C~40 °C)
Load regulation
(%of output+offset)
Line regulation
(%of output+offset)
Setup resolution
voltage current
power voltage current voltage current
voltage current
0 ~32V
0~110A
850W 1500W
0.01%+10mV
0.1%+20mA
0.01%+10mV
0.1%+20mA
10mV
10mA
Readback resolution
Setup accuracy
one year)(25°C±5°C)
(%of output+offset) Readback accuracy
one year)(25°C±5°C)
(%of output+offset)
Ripple
Temp.coefficient
( 0 °C~40 °C)
Working temperature
Dimensionmm 214.5mmW×88.2mmH×445mmD
Weightnet 6Kg
voltage current
voltage current voltage
current voltage
current voltage current
0 °C~40 °C
10mV 10mA
0.01%+10mV
0.1%+20mA
0.01%+10mV
0.1%+20mA
80mVp-p
150mA rms
0.01%+10mV
0.1%+20mA
17
User Manual
Parameters IT6723 IT6724
Rated values
( 0 °C~40 °C)
Load regulation
(%of output+offset)
Line regulation
(%of output+offset)
Setup resolution
voltage current
power voltage current voltage current
voltage current
IT6700 User manual
0~80V 0~40A
850W 850W
0.01%+10mV
0.1%+20mA
0.01%+10mV
0.1%+20mA
10mV
10mA
Readback resolution
Setup accuracy
voltage current
voltage
one year)(25°C±5°C)
(%of output+offset) Readback accuracy
current voltage
one year)(25°C±5°C)
(%of output+offset)
Ripple
Temp.coefficient
( 0 °C~40 °C)
current voltage
current voltage current
Working temperature
Dimensionmm
214.5mmW×88.2mmH×445mmD
Weightnet 6Kg
10mV 10mA
0.01%+10mV
0.1%+20mA
0.01%+10mV
0.1%+20mA
80mVp-p
50mArms
0.01%+10mV
0.1%+20mA
0 °C~40 °C
User Manual
18
IT6700 User manual
Parameters IT6723B IT6724B
Rated values
( 0 °C~40 °C)
Load regulation
(%of output+offset)
Line regulation
(%of output+offset)
Setup resolution
Readback resolution
Setup accuracy
one year)(25°C±5°C)
(%of output+offset) Readback accuracy
one year)(25°C±5°C)
(%of output+offset)
Ripple
voltage current
power voltage current voltage current
voltage current voltage
current voltage
current voltage
current voltage
current
IT6726B
0~80V 0~40A
850W
0.01%+10mV
0.1%+20mA 0.1%+20mA
0.01%+10mV 0.01%+60mV
0.1%+20mA 0.1%+20mA
10mV 100mV
10mA 10mA
10mV 100mV 10mA 10mA
0.01%+10mV 0.01%+60mV
0.1%+20mA 0.1%+20mA
0.01%+10mV 0.01%+60mV
0.1%+20mA 0.1%+20mA
80mVp-p 200mVp-p
50mArms 50mA rms
3000W
160V
40A
3000W
0.01%+60mV
Temp.coefficient
( 0 °C~40 °C)
Working temperature
voltage current
0.01%+10mV 0.01%+60mV
0.1%+20mA 0.1%+20mA
0 °C~40 °C
Dimensionmm 214.5mmW×88.2mmH×445mmD
Weightnet 6Kg
0~40°C
439mmW×88.20m mH
×462mmD
13Kg
19
User Manual
IT6700 User manual
Rated values
( 0 °C~40 °C)
Load regulation
(%of output+offset)
Line regulation
(%of output+offset)
Setup resolution
Readback resolution
Setup accuracy
Parameters IT6723H IT6724H
voltage current
power voltage current voltage current
voltage current voltage
current voltage
850W 1500W
0 ~300V
0~10A
0.01%+60mV
0.1%+20mA
0.01%+60mV
0.1%+20mA
100mV
10mA
100mV
10mA
0.01%+60mV
one year)(25°C±5°C)
(%of output+offset) Readback accuracy
current voltage
0.1%+20mA
0.01%+60mV
one year)(25°C±5°C)
(%of output+offset)
Ripple
current voltage
current
0.1%+20mA
150mVp-p
30mA rms
Temp.coefficient
( 0 °C~40 °C)
Working temperature
Dimensionmm
Weightnet
voltage current
0.01%+60mV
0.1%+20mA
0 °C~40 °C
214.5mmW×88.2mmH×445mmD 6Kg
User Manual
20
IT6700 User manual
Parameters IT6723G
Rated values
( 0 °C~40 °C)
Load regulation
(%of output+offset)
Line regulation
(%of output+offset)
Setup resolution
Readback resolution
Setup accuracy (one year)(25°C±5°C) (%of output+offset)
Readback accuracy
(one year)(25°C±5°C)
(%of output+offset)
Ripple
voltage current
power voltage current
voltage current
voltage current
voltage current
voltage
current
voltage current
voltage current
IT6724G
0~600V
0~5A
850W 1500W
0.01%+100mV
0.1%+10mA
0.01%+100mV
0.1%+10mA
100mV
10mA
100mV
10mA
0.01%+100mV
0.1%+10mA
0.01%+100mV
0.1%+10mA
150mVp-p
20mA rms 30mA rms
Temp.coefficient
0-40
Working temperature
Dimensionmm
Weightnet
voltage current
0.01%+100mV
0.1%+10mA
0-40
214.5mmW×88.2mmH×445mmD
6Kg
21
User Manual
Parameters IT6726H IT6726G
Rated values
( 0 °C~40 °C)
Load regulation
(%of output+offset)
Line regulation
(%of output+offset)
Setup resolution
voltage current
power voltage current
voltage current
voltage current
IT6700 User manual
IT6726V
0 ~300V 0 ~600V 0~1200V
0~20A 0~10A 0~5A
3000W 3000W 3000W
0.01%+60mV 0.01%+100mV
0.1%+20mA 0.1%+20mA 0.1%+20mA
0.01%+60mV 0.01%+100mV
0.1%+20mA 0.1%+20mA 0.1%+20mA
100mV 100mV 100mV
10mA 10mA 10mA
0.01%+200m
V
0.01%+200mV
Readback resolution
Setup accuracy
one year(25°C±5°C)
(%of output+offset)
Readback accuracy
one year(25°C±5°C)
(%of output+offset)
Ripple
Temp.coefficient
0-40
Working t em p er at ur e
Dimensionmm
Weightnet
voltage current
voltage
current
voltage current
voltage current
voltage current
0-40 0-40
100mV 100mV 100mV
10mA 10mA 10mA
0.01%+60mV 0.01%+100mV
0.1%+20mA 0.1%+10mA
0.01%+60mV 0.01%+150mV
0.1%+20mA 0.1%+10mA
250mVp-p 300mVp-p
30mA rms 30mA rms
0.01%+60mV 0.01%+100mV
0.1%+20mA 0.1%+20mA
439mmW×88.20mmH×462mmD 439mmW×88.20mmH×462mmD
13Kg 13Kg
0.01%+200m
V
0.1%+10mA
0.01%+200m
V
0.1%+10mA
600mVp-p
30mA rms
0.01%+200m
V
0.1%+30mA
0-40
4.2 Supplementary parameters
Memory 9×8 groups suggested calibrationfrequency:1time/year
Max input AC power IT6723/IT6723B/IT6723H/T6723G 1100VA IT6723C 1150VA IT6724/IT6724B/IT6724H/IT6724G 1850VA IT6724C 1900VA IT6726H/IT6726G/IT6726V/IT6726B 3700VA
User Manual
22
IT6700 User manual
Radiating mode :Fans Operation temperature:0 to 40 °C Storage temperature:-20 to 70 °C. Humidity :Max humidity: 80%
Chapter5 Basic operation
This chapter will introduce the basic operation of IT6700 series power supply,including the following subdivisions:
Local/remote mode Voltage setup Current setup Output on/off operation Setup value/actual value switching Voltage/current/power adjustment Save/recall operation Trigger operation Menu operation OVP protection function Key lock function Remote sense function
5.1 Local/Remote Mode
Local button can enable you switch mode from remote to local mode.
After you power on the power supply, the power supply’s default mode is local mode, all the buttons can be used in this mode. While in remote mode, you can’t operate through front panel directly except Meter and Local keys. Local and remote mode can be controlled through PC. In addition, the mode changing will not influence the output parameters.
5.2 Voltage Setup
You can set voltage within the range of rated voltage value. When you press button, the button will be lit. This indicates that you can set voltage. There are three ways to set output voltage through front panel.
The first way: press
and will enable you to adjust the setting voltage value.
The second way: press
rotary knob to change the setting voltage value.
The third way: press
V-setV-set
,adjust cursor location through button, pressing
V-setV-set
V-setV-set
, adjust cursor location through button, adjust
button and number key(0 to 9) to set voltage value
V-setV-set
23
User Manual
IT6700 User manual
5.3 Current Setup
You can set current within the range of rated current value. When you press button, the button will be lit. This indicates that you can set current. There are three ways to set output current through front panel.
The first way: press
I-setI-set
,adjust cursor location through button, push
I-setI-set
and
rotary knob to change the setting current value.
will enable you to adjust the setting current value.
I-setI-set
I-setI-set
,adjust cursor location through button, adjust
button and number key(0 to 9) to set current value
The second way: press
The third way: press
5.4 Output On/Off Operation
On/Off
button is lit, this indicates the output is in on mode. When output is open, the working state indicator light(CV/CC) will be lit.
Note: make sure you have connected power supply and the test unit well, then press
On/Off
set.
button is used to control the output state of power supply. When
button. If there is no voltage output, you should first check the voltage and current
On/Off
5.5 Setup value/Actual value switching
You can switch the display between setting value and actual value by pressing button. When this button is lit, screen displays actual output value and the indicator light “Meter” will be lit on the VFD. In other words, when the button is not lit, the front panel displays setting value.
MeterMeter
5.6 Voltage/Current/Power adjustment
The output current value is determined by output voltage of power supply and electronic load’s resistance. Only when the actual current value is lower than the setting current value, can power supply work in CV mode and the will CV indicator light be lit.
If output current is higher than the setting value, then power supply will function in CC mode. And the CC indicator light will be lit.
The output voltage and current value are also influenced by the upper limit of output power.
Take IT6723H (300V/10A/850W) for example, suppose you set the voltage to 100V, then the current can just reach 8.5A(limited by the power).
User Manual
24
IT6700 User manual
5.7 Save/recall Operation
Customer can save some often-used parameters in nonvolatile memory. You can use the button (Shift)
function. Saving parameters include:
1. setting voltage 2. setting current 3. OVP value 4. OCP value
Saving operation:
Press (Shift)+ group number you want to save through number key board. Press
confirm. Recall operating:
Press number(number1-9).At last press
Note: the memory capacity is 9*8, which indicate 8 memory groups and 9 memory in each
group. The memory group you use at the present should be selected in the Menu(MEM GROUP)., refer to chapter 5.9.
Recall
Recall
Recall
button(
(Save) button or SCPI order *SAV、*RCL to achieve this
(save) button(
Recall
button will lit), and press corresponding group
Enter
Recall
button to confirm.
button will flash), and then input the
Enter
button to
5.8 Trigger operation
The trigger source of IT6700 include manual and BUS, manual means trigger by button of the front panel, and BUS means trigger by command from the PC.
You need to select the trigger source(TRIG) from the menu before using this function.
After you edit a list file, press During the running process,
Enter
(Shift)+
button will flash all the time.
Enter
Triggerto give a trigger signal.
5.9 Menu operation
5.9.1 Menu description
Press the screen, through direction keys and rotary knob to overturn VFD display, then the screen
will display the following functions .Press
Press
MAX VOLT Set the max voltage output limit OCP SET
SYST SET
ESC
(Shift)+
button will return to previous menu.
OFF Disable the OCP function ON enable the OCP function
P-MEM RESET
P-OUT (OFF)
I-setI-set
(Menu) to enter the menu. You will see a optional items on
Enter
Reset Keep
OFF Set the power-on output state to be Offt Keep
Power on parameter is restored to factory
setting
Set the power-on parameter as the last
power off state
Set the power-on output state to be the last
power-off output state
25
button will enter corresponding items.
User Manual
LIST SET
POWER INFO
GPIB
COMM (GPIB)
RS232
USB Select USBcommunication interface
BEEP (ON)
KNOB (ON)
TRIG (MANUAL)
MEM (GROUP1) GRP1-8
TIMER SET
RESET EXIT LIST STATE LIST LOAD
LIST EDIT
EXIT MODEL ITXXXX VER
OFF ON LOCK ON MANU BUS
OFF ON NO
YES
Quit the menu setting
OFF ON
Re-load the LIST file(FILE0-FILE9)
TIME (SEC) VSET
ISET SEC
NEXT (YES) REPET 1-65535
SAVE
Exit the system menu Unit model
the software version
IT6700 User manual
ADDR
BAUD
NONE 8BIT
MODE
Disable the key sound Enable the key sound Lock the rotary knob function Un-lock the rotary knob function Local keyboard trigger Trigger by command
Select memory group for Save and recall operation Disable the timer function Enable the timer function, time range
0.1-99999S keep the present settings
restore the factory setting
Set the LIST state as OFF Set the LIST state as ON
SEC MIN
Set the voltage for present step Set the current for present step Setup single step delay time (0.1-9999)
YES NO
NO FILE0-FILE9
Address can be set within 0-30 4800 9600 19200 38400 57600
115.2K NONE 8BIT EVEN 8BIT ODD 8BIT SIGNAL
Address can be set within
MUX
0-30
Second Minute
continue the edit of next step End up the list file edit Set the cycle count of list file
Un-save the current LIST file Save the list file to appointed
memory
User Manual
26
IT6700 User manual
SN-1 XXXXXX SN-2 XXXXXX SN-3 XXXXXX EXIT
EXIT MENU
Exit the main menu
NotePressing
ESC
button can enable you to quit any function setting.
the first six number of SN the middle six number of SN the last six number of SN Exit the information menu
5.9.2 Menu functions
Maximum voltage setMAX VOLT
The range of setting voltage is from 0V to rated voltage. You can press
(Shift)+
VOLT item. Press voltage value can only be set within the max voltage. The default max voltage value is the rated value.
Over current protection set(OCP SET)
I-setI-set
(Menu) button to enter the menu, then press key to select >MAX
Enter
button to confirm. After you set the max voltage value, the output
Over current protection feature allows the user to set an over current protection point, when
the current in the circuit is larger than the current protection point, the power supply will
enter OCP protection. Over current protection, power output will be off, and accompanied by
the chirping of the buzzer, the VFD mark Prot will be lit, and the emergence of "OVER
CURR" alarm
The operation to set the OCP point:
Press
press
(Shift)+
Enter
pressing numeric keys, then press
I-setI-set
Menubutton to menu, press to overturn to OCP SET
button,and to select ON,press
Enter
. At last, press to escape.
Enter
to confirm, set OCP point by
Esc
Power-on parameters set (P-MEM)
Esc
This item can set power on parameters. If you select RESET item, then all the
parameters will be initialized to the factory setting. Output voltage and current will always be
0V/max rated current; if set to Keep, the output value will be the same with last power off
state. The default setting is RESET item.
Power On Output State(P-OUT )
This item can set the power on output state. If you select KEEP item, that indicates the power on output state is the same with output state before this item is set. If you select Off item, unit will automatically in off mode when you power on. Default setting is Off item.
27
User Manual
IT6700 User manual
Communication (COMM )
Our unit has provided three standard communication interfaces: RS232/USB/GPIB.In this
option, you can select the communication interface according to your demands. The range
of GPIB address is 0-30. Besides, we have multi-baudrate to be chosen in RS232
mode---4800,9600,19200,38400,57600,115.2K.Data bit is 8,Check digit have three choices:
NONE,ODD,EVEN.Before you begin to carry out communication,please make sure the
configure in our unit agrees with PC configure.
Key Sound Set(BEEP )
This item can set the key sound state.If in On mode, the power supply will issue beeper sound when you press any button.If in Off mode,the beeper will not make a sound.The
default set is in on mode.
Rotary Knob SetKNOB
This item is used to set rotary knob state.In On mode,you can use this rotary knob to set the output value and overturn the menu items.In Lock mode,this knob can’t be used.The default setting is in On mode.
Trigger sourceTRIG
Before you running a list file, you need a trigger signal.Thus you must set the trigger mode
first: keyboard trigger or command trigger. In MANU trigger mode,press
(Shift)+
Enter
button can generate a trigger signal. In BUS trigger mode,you can only trigger through sending command. The default set is MANU option.
Memory Group SetMEM GROUP
Power supply can save some often-used parameters in a nonvolatile memory(capacity is
9*8 groups).This function can make the operations more convenient. Customer can save
and recall parameters quickly.
GRP1:This indicates saving power supply parameters in 1-9 groups.Press (Shift)+
Recall
groups.
GRP2:This indicates saving the parameters in 10-18 groups.Press (Shift) +
(Save) and the group number(1-9) can save the parameters in corresponding
Recall
(Save)+saved group number(1-9)can save related parameters.Note that the current
number “1” represents parameters are saved in 10
th
parameters are saved in 11
User Manual
groups.
28
th
groups.Number “2” represents the
GRP3-GRP8 by parity of reasoning.
IT6700 User manual
Detailed Save and Recall operation refer to chapter 5.7.
Timer SetTIMER SET
This item is used to set the “time on- load” function, time range 0.1-99999S .In ON
mode,the indicator light “Timer” will be lit on the VFD screen.When output of power supply
is opened,timer will begin to work,after reaching the definite time,output will be off
automatically.If in OFF mode,the timer function will not be enabled.The default set is OFF
ResetRESET
This item is used to reset all items in the menu.If you select YES,then unit will restored to factory setting.If you select NO,all settings in the menu will remain unchanged.
List(List Set)
IT6700 series power supply provides 9 list files,each list file includes 150 steps. Before you edit a list file,please set the trigger mode:manual mode.
Press
(Shift)+
select >SYST SET option,after that please push direction key to select >Trig MANUAL and push
You can make the output change order by editing every step value of list operation. The parameters you need to edit includes:single-step voltage,single-step current,single-step delay time and whether to go on the next step.Besides,you also need to set the repeat times and save list sequence file.After the editing process,at this time if a trigger signal is received,power supply will begin to work according to the sequence steps you’ve edit. Now we take five steps for an example: Operation steps:
(1) Press
(Shift)+
(2) VFD display >MAX VOLT ,press (3) VFD display >LIST STATE,press
(4) VFD display >TIME SEC,press
through
button to select >TIME MIN time unit,press
(5) VFD display >VSET 0.0press number key
voltageafter that press
(6) VFD display ISET 0.00, press number key
single-step current, press
(7) VFD display SEC 0.100press number key
delay time,press
step, VFD will display MIN 0.100 for this step, time range 0.1~9999min.
I-setI-set
I-setI-set
(Menu)button to enter the menu,then press direction key to
Enter
Enter
button to confirm.At last to press
button to confirm.
Menubutton to enter the menu
Enter
to confirm
Enter
to confirm.
to confirm
Enter
to select >LIST SET,press
to select >LIST EDIT press
Enter
Enter
Enter
to confirm.
to confirm.
to confirmgo to the next step,you can also
Enter
0
to 9 or through rotary knob to set
0
to 9 or rotary knob to set the
0
to 9or rotary knob to set single-step
to confirm(range is 0.1-9999). If you choose MIN for the 4th
29
User Manual
IT6700 User manual
(8) VFD display NEXT >YES,press
(9) Repeat the steps from 5) to 8) and set the four steps’ voltage/current and delay time
separately. When screen display NEXT>YES in the fourth step edit process,please press
to select NEXT >NO,press
(10) VFD display REPET 1,press number key
timespress
Enter
to confirm.
(11) VFD display SAVE >NO,press
Enter
Enter
to confirm.
to confirm.
Enter
to confirm,in this circumstance,the list file is
0
to 9 or rotary knob to set the repeat
not saved but can run for one time,or you can press
FILE0,saving the list test file in FILE0~FILE9,press
Enter
button to select >SAVE
to confirm.You can recall the
file in the following utilization.
(12) If you do not save the list test file,VFD will display LIST EDIT;if you select to save the test file,VFD will display SAVE DONE for three seconds,and then display LIST EDITL.
Set List State
(13) Press
to select >LIST STATE item,press
(14) VFD display LIST >OFF, press
confirm.Now
Enter
button will be lit.This indicates that list operation function has been
to select >LIST >ON, press
Enter
to confirm.
Enter
to
opened.
Esc
(15) VFD display >LIST STATE,pressing
button can quit the operation.
Run list file
(16) Press
On/Off
button to open the output,press (Shift)+
Enter
Triggerto give
a trigger signal.
Recall list file
(17) If you have edited several list files,you can select LIST LOAD item to recall the file
Esc
you need.And then press
to quit this operation.Press
output.Now you only need to press
(Shift)+
Enter
(Trigger) to give a trigger signal,the list
On/Off
button to open the
file can be ran.
Quit list file
(18) In LIST mode,voltage set and current set button can’t be used,In LIST STATE
item,choose LIST>OFF will enable you to quit list mode.
User Manual
30
IT6700 User manual
TriggerTrigger
5.10 OVP function
IT6700 series power supply provide OVP function,press (Shift)+ enable you to set the over voltage protection level.Over voltage may caused by internal defect or customer’s incorrect operation(such as output voltage rising),or a too high external voltage.Once OVP function is triggered,the output will be off immediately and “OVP” indicator light will be lit,the VFD display “OVER VOLT”
Avoid external voltage that across the output terminals exceeding the 120% of rated voltage or it will damage out power supply!
When power supply in OVP state,please check the external factors first, after you exclude the external factors, press ON/OFF button to open output again.If in communication state originally, you should by sending order OUTP ON order to open output.
V-setV-set
button can
5.11 Key Lock function
Press (Shift)+
locked,the indicator light Lock will display on the VFD screen.In addition,when key board
are lock,all butttons can’t be used but ON/OFFMeter butonshift button.Press this button once again will relieve key lock function.
On/Off
Lockbutton to set the key lock state.If keyboard has been
5.12 Remote sense function
Vo+Vo- :output terminals,the same with front pannel output terminals ; Vs+Vs- remote sense pins. Disconnect the wires between “+-”pins if you want to use remote sense function.Then lead a wire from S+S- pins and connect to the under test objects.
31
User Manual
IT6700 User manual
Remote sense function
Remote sense can adjusted at the output voltage of the device under test, this feature allows to compensate the voltage drop on the wire between the front panel terminals of the
power supply and the device under test.
Use local sense
Local sense doesn’t compensate the voltage drop on the connection wire, the operation is:
1. Use the short clips on the back panel of the instrument, or install wire between Vo+ an
Vs
+ Vo- and
Connect the the positive and negative terminals of the front panel to the device
2.
test
Vs-
d
under
Use remote sense:
1. Disconnect the wires/short clips between Vo+ and Vs+ Vo- and Vs-
Connect
2.
3. Connect
wires from Vs+ 、Vs- to the device usder te wires from Vo+ 、Vo- to the device under
st
test
Note:
In order to ensure the stability of the system, using armored twisted pair cable
between the remote sense terminal of IT6700 and load.
Please note that the positive and negative polarity when wiring, otherwise it
will damage the instrument!
Vo+ Vs+ Vs- Vo-
User Manual
32
IT6700 User manual
Chapter6 Remote Operation Mode
IT6700 series power supply three standard communication interface: RS232, USB, GPIB, the user can choose any one of them to implement a communication with the computer.
6.1 RS232 interface
There is a DB9 connector at the rear of the power supply, when connect to computer, you need to select a cable with COM port on both side; To active communication,you need to enable the settings in menu to be the same with the PC communication configuration.
NoteThe RS232 settings must match the settings in front panel system information. If any
I-setI-set
I-setI-set
key to modify the menu: SYST SET\COMM.
parity items with (Shift)+
button allows the user to select a baud rate which is
I-setI-set
key on
change, please press
(Shift)+
RS-232 data format
RS-232 data is a 10-bit words which has a start bit and a stop bit. The start bit and stop
bit can’t be edited. However, you can select the the front panel. Parity options are stored in nonvolatile memory
Baud Rate
The front panel (Shift)+
stored in the non-volatile memory: 4800,9600,19200 38400,57600,115200
RS-232 connection cable
Use a RS232 cable with DB-9 interface, RS-232 serial port can connect with the controller (eg PC). Do not use blank Modem cable. Below Table shows the plug pins. If your computer is using a RS-232 interface with DB-25 connector, you need an adapter cable with a DB-25 connector at one end and the other side is a DB-9(not blank modem cable)
33
User Manual
IT6700 User manual
RS-232 plug pins
Pin number Description
1 No connection
2 TXD, transfer date
3 RXD, receive data
4 No connection
5 GND, ground
6 No connection
7 CTS, clear transfer
8 RTS, ready to transfer
9 No connection
RS-232 Troubleshooting:
If there is RS-232 connection problem, check the following: Computer and power supply must configure the same baud rate, parity, data bits and flow control options. Note that the power configuration as a start bit and a stop bit (these values are fixed). As described before in RS-232 connector, you must use the correct interface cable or adapter. Note that even if the cable has the right plug, the internal wiring may be wrong. Interface cable must be connected to the correct serial port on the computer (COM1, COM2, etc.).
Communication Settings
Before communication, you should first make the following parameters of power supply and PC matches. Baud Rate: 9600 (4800,9600,19200,38400,57600,115200). You can enter the system menu from the front panel, and then set the baud rate. Data bits: 8 Stop Bits: 1 calibration (none, even, odd) EVEN 8 data bits, have even parity ODD 8 data bits have odd parity NONE 8 data bits, no parity Local Address: (0 ~ 31, the factory default setting is 0)
Parity=None Start Bit 8 Data Bits Stop Bit
6.2 USB interface
Use a Cable with two USB port to connect the power and the computer. All power functions can be programmed via USB. The USB488 interface functions of the power supply described as below: interface is 488.2 USB488 interface.
User Manual
34
IT6700 User manual
Interface Receiver REN_CONTROL, GO_TO_LOCAL, and LOCAL_LOCKOUT request. Interface receive MsgID = TRIGGER USBTMC order information, and will pass TRIGGER order to the functional layer. Power USB488 device functions described as follows: devices can read all of the mandatory SCPI orders. device is SR1 enabled. device is RL1 enabled. device is DT1 enabled.
6.3 GPIB interface
First, Connect the GPIB interface on the power supply and the GPIB card on computer via IEEE488 bus, must be full access and tighten the screws. Then set the address, the address range of the power : 0 to 30, can set by the function key on the front panel, press
the by
nonvolatile memory line.
Note: Forbidden to connect DB9 connector in power supply directly with PC or other RS232 port.
(Shift)+
I-setI-set
button, type the address,
key to enter the system menu function, find the GPIB address setting
EnterEnter
key to confirm. GPIB address is stored in
35
User Manual
IT6700 User manual
Support process
If you have a problem , follow these steps: 1 Check the documentation that come with the product 2 Visit the ITECH online service Web site is www.itechate.com ITECH customers. It is the fastest source for up-to-date product information and expert assistance and includes the following features :
Fast access to email AE
Software and driver updates for the product
Call ITECH support line 025-52415098
,ITECH is avaliable to all
User Manual
36
Via Acquanera, 29 22100 Como tel. 031.526.566 (r.a.) fax 031.507.984
info@calpower.it www.calpower.it
Loading...