ITech IT6322A, IT6333AIT6322B, IT6332B, IT6333B, IT6332A User Manual

Triple Output Programmable
DC Power Supply
Series IT6300A/B User’s Manual
Model: IT6322A/IT6332A/IT6333A
Version: V2.1
Notices
© Itech Electronics, Co., Ltd. 2017 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior permission and written consent from Itech Electronics, Co., Ltd. as governed by international copyright laws.
Manual Part Number
IT6300A/B-402204
Revision
Second Edition: February 28, 2017 Itech Electronics, Co., Ltd.
Trademarks
Pentium is U.S. registered trademarks of Intel Corporation.
Microsoft, Visual Studio, Windows and MS Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries and regions.
Warranty
The materials contained in this
document are provided “as is”, and
is subject to change, without prior notice, in future editions. Further, to the maximum extent permitted by applicable laws, ITECH disclaims all warrants, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. ITECH shall not be held liable for errors or for incidental or indirect damages in connection with the furnishing, use or application of this document or of any information contained herein. Should ITECH and the user enter into a separate written agreement with warranty terms covering the materials in this document that conflict with these terms, the warranty terms in the separate agreement shall prevail.
Technology Licenses
The hardware and/or software described herein are furnished under a license and may be used or copied only in accordance with the terms of such license.
Restricted Rights Legend
Restricted permissions of the U.S. government. Permissions for software and technical data which are authorized to the U.S. Government only include those for custom provision to end users. ITECH follows FAR 12.211 (technical data), 12.212 (computer software). DFARS 252.227-7015 (technical data--commercial products) for national defense and DFARS 227.7202-3 (permissions for commercial computer software or computer software documents) while providing the customized business licenses of software and technical data.
Safety Notices
A CAUTION sign denotes a hazard. It calls attention to an operating procedure or practice that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION sign until the indicated conditions are fully understood and met.
A WARNING sign denotes a hazard. It calls attention to an
operating procedure or practice that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING sign until the indicated conditions are fully understood and met.
NOTE
A NOTE sign denotes important hint. It calls attention to tips or supplementary information that is essential for users to refer to.
IT6300A/B User’s Manual
Copyright © Itech Electronics Co., Ltd. iii
Quality Certification and Assurance
We certify that IT6300A/B series power supply meets all the published specifications at time of shipment from the factory.
Warranty
ITECH warrants that the product will be free from defects in material and workmanship under normal use for a period of one (1) year from the date of delivery (except those described in the Limitation of Warranty below).
For warranty service or repair, the product must be returned to a service center designated by ITECH.
The product returned to ITECH for warranty service must be shipped
PREPAID. And ITECH will pay for return of the product to customer.
If the product is returned to ITECH for warranty service from overseas, all
the freights, duties and other taxes shall be on the account of customer.
Limitation of Warranty
This Warranty will be rendered invalid if the product is: Damaged resulting from customer-wired circuits or customer-supplied
parts or accessories;
Modified or repaired by customer without authorization; Damaged resulting from customer-wired circuits or use in an environment
not designated by us;
The product model or serial number is altered, deleted, removed or made
illegible by customer;
Damaged as a result of accidents, including but not limited to lightning,
moisture, fire, improper use or negligence.
Safety Symbols
Direct current
ON (power)
Alternating current
OFF (power)
Both direct and alternating current
Power-on state
Chassis (earth ground) symbol.
Power-off state
Earth (ground) terminal
Reference terminal
IT6300A/B User’s Manual
Copyright © Itech Electronics Co., Ltd. iv
Caution
Positive terminal
Warning (refer to this manual for specific Warning or Caution information)
Negative terminal A chassis terminal
-
-
Safety Precautions
The following safety precautions must be observed during all phases of operation of this instrument. Failure to comply with these precautions or specific warnings elsewhere in this manual will constitute a default under safety standards of design, manufacture and intended use of the instrument.
ITECH assumes no liability for the customer’s failure to comply with these
precautions.
Do not use the instrument if it is damaged. Before operation, check the
casing to see whether it cracks. Do not operate the instrument in the presence of inflammable gasses, vapors or dusts.
The power supply is provided with a three-core power line during delivery
and should be connected to a three-core junction box. Before operation, be sure that the power supply is well grounded. Make sure to use the power cord supplied by ITECH.
Check all marks on the instrument before connecting the instrument to
power supply.
Use electric wires of appropriate load. All loading wires should be capable
of bearing maximum short-circuit of electronic load without overheating. If there are multiple loads, each pair of the load power cord must be carry out the full rated short-circuit output current of the power securely.
Ensure the voltage fluctuation of mains supply is less than 10% of the
working voltage range in order to reduce risks of fire and electric shock.
Do not install alternative parts on the instrument or perform any
unauthorized modification.
Do not use the instrument if the detachable cover is removed or loosen. To prevent the possibility of accidental injuries, be sure to use the power
adapter supplied by the manufacturer only.
Never use the instrument with a life-support system or any other equipment
subject to safety requirements.
Failure to use the instrument as directed by the manufacturer may render
its protective features void.
Always clean the casing with a dry cloth. Do not clean the internals. Make sure the vent hole is always unblocked.
IT6300A/B User’s Manual
Copyright © Itech Electronics Co., Ltd. v
Environmental Conditions
The instrument is designed for indoor use and an area with low condensation. The table below shows the general environmental requirements for the instrument.
Environmental Conditions
Requirements
Operating temperature
0°C to 40°C
Operating humidity
20%-80% (non-condensation)
Storage temperature
-20°C to 70 °C
Altitude
Operating up to 2,000 meters
Installation category
II
Pollution degree
Pollution degree 2
Note
To make accurate measurements, allow the instrument to warm up for 30 min.
Regulatory Markings
The CE mark indicates that the product complies with all the relevant European legal directives. The specific year (if any) affixed refers to the year when the design was approved.
The instrument complies with the WEEE Directive (2002/96/EC) marking requirement. This affix product label indicates that you must not discard the electrical/electronic product in domestic household waste.
This symbol indicates the time period during which no hazardous or toxic substances are expected to leak or deteriorate during normal use. The expected useful life of the product is 10 years. The product can be used safely during the 10-year Environment Friendly Use Period (EFUP). Upon expiration of the EFUP, the product must be immediately recycled.
IT6300A/B User’s Manual
Copyright © Itech Electronics Co., Ltd. vi
Waste Electrical and Electronic Equiment (WEEE) Directive
2002/96/EC Waste Electrical and Electronic Equipment (WEEE) Directive
This product complies with the WEEE Directive (2002/96/EC) marking requirement. This affix product label indicates that you must not discard the electrical/electronic product in domestic household waste.
Product Category With reference to the equipment classifications described in the Annex 1 of the WEEE Directive, this instrument is classified as a “Monitoring and Control Instrument”. To return this unwanted instrument, contact your nearest ITECH office.
IT6300A/B User’s Manual
Copyright © Itech Electronics Co., Ltd. vii
Compliance Information
Complies with the essential requirements of the following applicable European Directives, and carries the CE marking accordingly:
Electromagnetic Compatibility (EMC) Directive 2014/30/EU Low-Voltage Directive (Safety) 2014/35/EU
Conforms with the following product standards:
EMC Standard
IEC 61326-1:2012/ EN 61326-1:2013 ¹²³
Reference Standards
CISPR 11:2009+A1:2010/ EN 55011:2009+A1:2010 (Group 1, Class A)
IEC 61000-4-2:2008/ EN 61000-4-2:2009
IEC 61000-4-3:2006+A1:2007+A2:2010/ EN 61000-4-3:2006+A1:2008+A2:2010
IEC 61000-4-4:2004+A1:2010/ EN 61000-4-4:2004+A1:2010
IEC 61000-4-5:2005/ EN 61000-4-5:2006
IEC 61000-4-6:2008/ EN 61000-4-6:2009
IEC 61000-4-11:2004/ EN 61000-4-11:2004
1. The product is intended for use in non-residential/non-domestic environments. Use of the product in residential/domestic environments may cause electromagnetic interference.
2. Connection of the instrument to a test object may produce radiations beyond the specified limit.
3. Use high-performance shielded interface cable to ensure conformity with the EMC standards listed above.
Safety Standard
IEC 61010-1:2010/ EN 61010-1:2010
IT6300A/B User’s Manual
Copyright © Itech Electronics Co., Ltd. viii
Contents
Quality Certification and Assurance ..................................................................................................................... iii
Warranty .............................................................................................................................................................. iii
Limitation of Warranty ......................................................................................................................................... iii
Safety Symbols ..................................................................................................................................................... iii
Safety Precautions ............................................................................................................................................... iv
Environmental Conditions ..................................................................................................................................... v
Regulatory Markings ............................................................................................................................................. v
Waste Electrical and Electronic Equiment (WEEE) Directive .................................................................................. vi
Compliance Information ......................................................................................................................................vii
Chapter1 Acceptance and Installation ............................................................................................................. 1
1.1 Confirm package contents ............................................................................................................................... 1
1.2 Installation Position ......................................................................................................................................... 1
1.3 Adjustment of power handle ........................................................................................................................... 4
1.4 Connecting the Power Cord ............................................................................................................................. 5
Chapter2 Quick Start ....................................................................................................................................... 6
2.1 Brief Introduction ............................................................................................................................................ 6
2.2 Introduction to the front panel ........................................................................................................................ 7
2.3 Introduction of the keypad .............................................................................................................................. 7
2.4 Introduction of indicators on the screen ......................................................................................................... 9
2.5 Introduction to the rear panel ......................................................................................................................... 9
2.6 Power-on selftest .......................................................................................................................................... 10
2.7 Output verification ........................................................................................................................................ 12
Chapter3 Function and Features .................................................................................................................... 13
3.1 Front-panel Operation Overview ................................................................................................................... 13
3.2 Menu Description.......................................................................................................................................... 14
3.3 Channel Operation ........................................................................................................................................ 20
3.4 OUT ON/OFF ................................................................................................................................................. 20
3.5 Timer operation ............................................................................................................................................ 21
3.6 Set Voltage .................................................................................................................................................... 21
3.7 Current Operation ......................................................................................................................................... 21
3.8 Save and Recall Operation ............................................................................................................................. 22
3.9 Key Lock Set .................................................................................................................................................. 22
3.10 Protections .................................................................................................................................................. 22
3.11 Remote sense function ................................................................................................................................ 23
Chapter4 Technical Specifications ................................................................................................................. 24
4.1 Major technical parameters .......................................................................................................................... 24
Chapter5 Communication with PC ................................................................................................................. 28
5.1 RS232 interface ............................................................................................................................................. 28
5.2 USB interface ................................................................................................................................................ 29
5.3 GPIB interface ............................................................................................................................................... 30
Appendix ................................................................................................................................................................ 31
IT6300A/B User’s Manual
Copyright © Itech Electronics Co., Ltd. ix
Specifications of Red and Black Test Lines ........................................................................................................... 31
Acceptance and Installation
Copyright © Itech Electronics Co., Ltd. 1
Chapter1 Acceptance and Installation
Power supply is a high level safety equipment, there is a protected ground terminal. Before Installation or operation, please read the safety signs and instructions in this manual.
1.1 Confirm package contents
Open the package and check the articles within package box before operation. In case of any non-conformity, missing or appearance wearing, please contact ITECH immediately.
The package box should comprise:
Device name
Quantity
Model
Remarks
Power supply
x1
IT6300A/B series
IT6300A/B series include: IT6322A/IT6332A/IT6333A/ IT6322B/IT6332B/IT6333B
Power Cord
x1
IT-E171/IT-E172/ IT-E173/IT-E174
The User may select different power cords based on local outlet specification. For detailed specifications, refer to 1.4 Connecting the Power
Cord.
CD
x1
-
It contains User’s Manual and Programming Guide.
Ex-factory Test Report
x1
-
It is the test report of the instrument before delivery.
NOTE
After confirming that package contents are consistent and correct, please appropriately keep package box and related contents. The package requirements should be met when the instrument is returned to factory for repair.
1.2 Installation Position
The instrument should be installed at well-ventilated and rational-sized space. Please select appropriate space for installation based on the power supply size.
IT6322A/IT6322B: 214.5mmW*88.2mmH*345mmD (W:width H:height
D:depth)
IT6332A/IT6333A/IT6332B/IT6333B: 214.7mmW*88.2mmH*444.5mmD
Refer to the dimension below:
Acceptance and Installation
Copyright © Itech Electronics Co., Ltd. 2
Front view for IT6322A/IT6332A/IT6333A/IT6322B/IT6332B/IT6333B.
Lateral view for IT6332A/IT6333A/IT6332B/IT6333B.
Unit: millimeter (mm)
IT6322A Model
Dimension: Width: 255mm Height: 108.7mm Depth:374.32
Detailed Dimension Drawing
Acceptance and Installation
Copyright © Itech Electronics Co., Ltd. 3
IT6322B Model
Acceptance and Installation
Copyright © Itech Electronics Co., Ltd. 4
Dimension: Width: 255mm Height: 108.7mm Depth:365.7mm
Detailed Dimension Drawing
1.3 Adjustment of power handle
To adjust the position, grasp the handle by the sides and pull outward. Then rotate the handle to the desired position.
Acceptance and Installation
Copyright © Itech Electronics Co., Ltd. 5
Bench operation Handle
1.4 Connecting the Power Cord
Connect power cord of standard accessories and ensure that the power is under normal power supply.
AC power input level
Working voltage of IT6300A/B series includes 110V and 220V (which can be selected by the switch at the bottom of load).
AC power input level:
Option Opt.01: 220VAC ± 10%, 47 to 63 Hz Option Opt.02: 110 VAC ± 10%, 47 to 63 Hz
Categories of power lines
Select from the flowing schedule of power cord specifications an appropriate power cord that matches the voltage for the area in which you use the instrument. If the power cord included in the instrument you purchased does not match the voltage, contact the dealer or manufacturer for change.
China
IT-E171
United States &
Canada & Japan
IT-E172
Europe
IT-E173
England
IT-E174
E
N L
E
L N
E
N L
E
L N
Quick Start
Copyright © Itech Electronics Co., Ltd. 6
Chapter2 Quick Start
This chapter introduces the front panel, the rear panel, key functions and VFD display function of the power supply, make sure that you can quickly know the appearance, instruction and the key function before you operate the power supply, Help you make better use of this series of power supply.
2.1 Brief Introduction
IT6300A/B series triple output programmable DC power supply, the output voltage or current of each channel can be set from 0 to max rated value.
The triple output power supply provides you with high-resolution, high accuracy and high stability, and supports over voltage, over temperature protection; Provides a serial or parallel mode, used to extend the voltage or current output capacity. Resolution reaches up to 1mV/1mA that it can meet the needs of a variety of applications, and is a great choice for University or R & D department and the manufacturer. The main features and advantages are as follows:
Triple output voltage, all are adjustable. CH1 and CH2 can set to serial/parallel/track mode. The voltage and current for the three channels can be displayed at the
same time.
Small size of 1/2 2U VFD display Function keys with LED light Remote measurement function, compensation online pressure drop. High accuracy resolution and stability. Switch to control the output status. Limited voltage and over heat protection. Intelligent fan control, energy conservation, noise reduction. Built-in RS232/USB/GPIB communication interface. Low ripple and low noise Shut off memory function Can be monitored by computer software. Can calibrate through software. Memory capacity of 36 groups, for save and recall. Can adjust the voltage or current by knob. Can adjust the stepping by Left/right arrow button. Output timer function (0.1 ~ 99999.9 seconds)
Model Selection Table for IT6300A/B Series:
Model
Channel
Voltage
Current
IT6322A
CH1
30V
3A
CH2
30V
3A
CH3
5V
3A
Quick Start
Copyright © Itech Electronics Co., Ltd. 7
IT6332A
CH1
30V
6A
CH2
30V
6A
CH3
5V
3A
IT6333A
CH1
60V
3A
CH2
60V
3A
CH3
5V
3A
IT6322B
CH1
30V
3A
CH2
30V
3A
CH3
5V
3A
IT6332B
CH1
30V
6A
CH2
30V
6A
CH3
5V
3A
IT6333B
CH1
60V
3A
CH2
60V
3A
CH3
5V
3A
*IT6322A/IT6332A/IT6333A has not standard GPIB communication interface.
2.2 Introduction to the front panel
The front panel of IT6300A/B series is shown in the next figure.
1. VFD display
2. Rotary knob
3. Power switch, Local and Shift key
4. Numeric keys and ESC escape key
5. Function keys
6. Up/Down/Left/Right keys
7. Output terminal
2.3 Introduction of the keypad
The keypad of IT6300A/B series is shown in the next figure.
Quick Start
Copyright © Itech Electronics Co., Ltd. 8
Key Symbol
Name & Function
09
Numeric keys. Use keys 1~3 to control the output state of the 3
channels which should coordinate with Shift key. Note: In key lock mode, Shift key is not needed.
Escape from the current setting or menu item.
(Shift)
Compound key.
(Local)
Used to switch to local operation mode.
(Power)
Used to power on/off the DC source.
/OVP
Used to set the voltage or shift+V-set to set OVP value.
/Menu
Used to set the current or shift+I-set to enter the menu operation.
/Save
Save or recall different operating parameters in memory locations.
Switch the display between setting value and actual value.
Enter button to confirm the selection.
/Lock
Used to control the output state of all channels or Shift+On/Off to lock the front keys.
Right/Left key, use to move the cursor or scroll through the menu items.
Up/down key, used to increase or decrease the setting value.
(Shift)+1,
(Shift)+2,
(Shift)+3
Used to turn on the output of corresponding channel no matter in menu operation or Meter state.
Esc
V-setV-set
I-setI-set
Recall
MeterMeter
Enter
On/Off
Quick Start
Copyright © Itech Electronics Co., Ltd. 9
2.4 Introduction of indicators on the screen
c
In constant current mode.
v
In constant voltage mode.
Keyboard operation for the lock mode.
Open the remote sense function.
Indicates the shift button is pressed.
Indicates the channel currently selected.
T
Enable tracking mode.
2.5 Introduction to the rear panel
The rear panel of IT6322B/IT6332B/IT6333B is shown in the next figure.
The rear panel of IT6322A/IT6332A/IT6333A is shown in the next figure.
1. Cooling window
2. RS232 communication interface
3. USB communication interface
4. GPIB communication interface
5. Remote measurement terminal
6. 110V/220V AC power selection switch and Fuse
Quick Start
Copyright © Itech Electronics Co., Ltd. 10
2.6 Power-on selftest
A successful selftest indicates that the purchased power product meets delivery standards and is available for normal usage.
Before operation, please confirm that you have fully understood the safety instructions.
To avoid burning out, be sure to confirm that power voltage matches with
supply voltage.
Be sure to connect the main power socket to the power outlet of
protective grounding. Do not use terminal board without protective grounding. Before operation, be sure that the power supply is well grounded.
To avoid burning out, pay attention to marks of positive and negative
polarities before wiring.
Selftest steps
Normal selftest procedures:
1. Correctly connect the power cord. Press Power key to start up.
2. After selftest, VFD display information as follows, the first row displays
the voltage, the second row displays the output state or the current. From left to right, as the first, second, third channel voltage current display area.
NOTE
The figure above is configuration menu (Config) for the factory set up on display, the different
Out State and Out Param setting in the menu will affect on the final state of the display.
Error Information References
The following error information may occur when an error occurs during Power On self-test:
If the EEPROM was damaged, the VFD will display “EEPROM Fail. If the latest operation state of the power supply was lost, then the VFD will
display “System Lost”.
If send channel data, the channel response failure, the VFD display the
tooltip information “Model Fail”.
If calibration data read failure, the VFD display the tooltip information “Cal
Lost”.
If the channel to send data loss, channel initialization failed, the VFD
0.000V 0.000V 0.000V
0.000A 0.000A 0.000A
Quick Start
Copyright © Itech Electronics Co., Ltd. 11
display the tooltip information “Model Lost”.
If the factory calibration data in EEPROM is lost, and then the VFD will
display “FACT LOST”.
Exception handling
If the power supply can not start normally, please check and take measures by reference to steps below.
1. Check whether the power cord is correctly connected and confirm
whether the power supply is powered. Correct wiring of power cord => 2
Incorrect wiring of power cord => Re-connect the power cord and check whether the exception is removed.
2. Check whether the power in On. Power key is under “ ” On status.
Yes => 3 No => Please check the Power key to start power and check whether the
exception is removed.
3. Check whether the fuse of power supply is burned out.
If yes, change fuse. Detailed steps:
1) Pull out power line and take out the fuse box at power line jack with a small screw driver. As shown below.
2) If the fuse is fused, please change fuse of same specification based on machine model. See the table blow for matching information of fuse and machine model.
Products
Specification (220VAC)
Specification (110VAC)
IT6322A/ IT6322B
3.15A T250V
6.30A T250V
IT6332A/ IT6332B
5A T250V
10A T250V
IT6333A/ IT6333B
5A T250V
10A T250V
3) After replacement, install the fuse box back to original position, as shown below.
----End
Quick Start
Copyright © Itech Electronics Co., Ltd. 12
2.7 Output verification
The following procedure verify that the power supply outputs the correct voltage and current levels and properly responds to entries from the front panel.
Voltage Output Check
The following steps verify basic voltage function without load.
1. Press Power key to turn on the power supply.
2. Press key to enable the output.
3. Set the voltage value. Adjust the voltage, then press to lit the key (indicates it is in the
METER mode), make sure that the set value and output value are same, and if the current displayed on the VFD is nearly 0A.
4. Make sure the voltage can be adjusted from zero to the maximum rated value.
5. Check the other two channels by the same method.
NOTE
when key is gray, the power supply is in SET mode, then the VFD displays the set
voltage and current; when the key is lit, then the power supply is in METER mode, the actual
voltage and current display on the VFD. When the output is OFF, the “OFF” indicate will display
at the current display area.
----End
Current output Check
The following steps check the basic current functionality by shorting the power supply’s output.
1. Press Power key to turn on the power supply.
2. Press to disable the output, ensure the output is OFF.
3. Connect a short across (+) and (-) output terminals with an insulated test lead, use a wire sufficient to handle the maximum current.
4. Adjust the voltage value to 1V.
5. Press to enable the output.
6. Adjust the current. Set some different current values, in METER mode, check whether the
voltage value on VFD is near 0v, and the current on it is close to the value you set.
7. Make sure that the current can be adjusted from 0 to full rated value.
8. Disable the output and then remove the short wire.
9. Check the other two channels by the same method.
----End
On/Off
MeterMeter
MeterMeter
On/Off
On/Off
Function and Features
Copyright © Itech Electronics Co., Ltd. 13
Chapter3 Function and Features
So far we have covered the quick start chapter which briefly introduced the front panel operation and how to check basic voltage and current functionality. This chapter describes in detail how to operate the instrument manually via the front-panel keys.
3.1 Front-panel Operation Overview
The power supply is shipped from the factory ready for front-panel
operation mode. At power-on, the power supply will automatically enter the front-panel operation mode and the instrument can be controlled via the front panel keys and knob.
The power supply enters remote mode as soon as a valid remote
command is received via the communication connector in the rear.
Switching to remote mode does not impact the supply’s output
parameters. In remote mode, front-panel operation is disabled. Only Meter and Local buttons are enabled. If the power supply is in remote
mode, and the (Local) key is enabled, you can revert to manual mode by pressing the (Local) key.
The power supply is in Set mode when it is powered on. In this mode, the
VFD will display the setting voltage and current.
The output of power supply can be enabled/disabled from the front panel
by pressing the button.When turn on the output,the VFD will display the state and voltage/current of each channel.”CC” represents
constant current mode.”CV” represents constant voltage mode.When output is in OFF mode,VFD will have no any indicators of CC or CV.
The VFD also displays operation states or error information. ”means
the power supply is in remote mode.When front-panel keys are locked,
button will be lit. “ ” means the power supply keyboard
locked .For more details, please refer to chapter of “Descriptions about VFD marks”.
If the power supply is in set mode, you can modify parameters using the
knob. If the power supply is in menu operation, the knob is used for menu selection.
 When , , , or buttons are
lit,means they are selected and under corresponding state now.If pressing (Shift)+ (Save), button will keeping
flickering and waiting for a number to be entered to specify the memory location.
When V-SET/I-SET buttons are lit, following conditions will enable the
cursor to display again. Pressing V-SET/I-SET buttons again. Adjusting the knob. Pressing direction buttons.
On/Off
Enter
V-setV-set
I-setI-set
Recall
MeterMeter
On/Off
Recall
Recall
Function and Features
Copyright © Itech Electronics Co., Ltd. 14
NOTE
If there is any operation on front panel within 5S, the cursor will disappear automatically. You
can also disable the cursor by pressing ESC button. When VFD displays cursor, you can modify
the parameters by adjusting knob or up/down keys, or move the cursor by right/left keys.
Details about key buttons’ state
When button is lit, means you can set voltage. When button keeps flickering, means in OVP setting mode.
When button is lit, means in current setting mode.
When button is lit, means in recall mode. When button keeps flickering, means in save mode and waiting for a number to be entered to specify the memory location.
When button is lit, means current VFD displays actual voltage and current.
When button is lit, means at least one channel output is on. Or all channels are in OFF mode.
NOTE
, , buttons will not be lit at the same time.
3.2 Menu Description
Press (Shift)+ (Menu) to indicate operation mode.View the menu on the VFD,and use the right/left key to change the setup, and up/down
key to scroll through the complete menu items. Press to enter the selected menu function.Press button to return to the previous
menu.When the item keeps filickering indicates it is selected currently.
Power Menu...
Config
Configuration Menu
Configuration Menu…
Configuration Menu
Out State
Power Out State Set
Power supply power on output state Settings
Off
all along OFF
Keep
Keep the last time state before the shutdown
Out Param
Power Out Param Set
Set up the related parameters when power on
Reset
default
Keep
Restore the last time parameters
Knob
Knob Function Set
Pulsating knob function Settings
Unlock
Pulsating knob function open
Lock
Pulsating knob function closed
Buzzer
Power Key Beeper Set
Key sound establishment
V-setV-set
I-setI-set
Recall
MeterMeter
On/Off
V-setV-set
I-setI-set
Recall
I-setI-set
Enter
Esc
Function and Features
Copyright © Itech Electronics Co., Ltd. 15
Off
Key sound closed
On
Key sound open
Communication
Communication Select
Communication interface choice
RS232
Choose RS232 communication interface
RS232 Communication Set
RS232 communication set
4800, 8, N, 1,Single
9600 O Mux
19200 E
38400
57600
115200
GPIB
Choose GPIB communication interface
Communication Address
GPIB communications address
Address=15 (0~31)
USB
Choose USB communication interface
Ext Port Ext Port settings…
External interface Settings
None
None
Memory Group
Select Memory Group
Memory group set
GRP1
Group 1
GRP2
Group 2
GRP3
Group 3
GRP4
Group 4
Command
SCPI Version
SCPI version select Select…
ITECH
ITECH SCPI command
EXT1
Extended SCPI command 1
EXT2
Extended SCPI command 2
Return Meter
Auto Return to Meter State
Auto Return to Meter State Off
Function close
Wait 5 Sec
The front panel display will change from setting to meter state automatically after 5s.
Reset
Reset Menu Default
restore the factory setting
No
Cancel
Yes
Enter
Exit
Exit the config menu
System
System Menu
Channel Sel …
Channel Select
CH1
System Menu…
Max volt Max voltage Set
Max Volt=31.000V
Function and Features
Copyright © Itech Electronics Co., Ltd. 16
Out timer
Out Timer State Set
Disable
Enable
Exit
CH2
System Menu…
Max Volt Max Voltage Set
Max Volt=31.000V
Out Timer
Out Timer State Set
Disable
Enable
Exit
CH3
System Menu…
Max Volt Max Voltage Set
Max Volt=6.000v
Out timer
Out Timer State Set
Disable
Enable
Exit
Comb
Power Combine Set…
Off
Series Series Choose…
Select serial connect mode
CH1+CH2
Connect CH1 and CH2 in serial
Parallel
Parallel Choose…
Select parallel connect mode
CH1+CH2
Connect CH1 and CH2 in parallel
CH2+CH3
Connect CH2 and CH3 in parallel
ALL
Connect three channels in parallel
Track
Track Choose…
Enable tracking function
CH1+CH2
Connect CH1 and CH2 in track
CH2+CH3
Connect CH2 and CH3 in track
ALL
Connect three channels in track
Exit
Exit the system menu
NOTE
In the menu, righ/left arrow keys and rotary knob used for flow around the menu, change the
options, Used to identify the current menu commands or into the next layer menu.
Press can exit menu or enter a layer menu.
Out State
This parameter sets the output On/Off state at power up. If you select
Keep”, the power supply will save the output state prior to power down and
revert to that state at power up. If you select Off”, the output state is always
Enter
Esc
Function and Features
Copyright © Itech Electronics Co., Ltd. 17
OFF” when the power supply is turned on. The recommend setting is OFF”.
Out Param
This menu item is used for set up power whether save the last output
parameters. If you select “Keep”, the power save the last time before the
shutdown of the output parameters. The next time after startup power output parameter is still the last output parameters. If you select “Reset”, the power output for factory default output parameters.
Knob
This item enables (“On”) or disables (“Off”) the knob.
Buzzer
This item turns the beep sound for key presses On” or Off”.
Communication
This item set the communication mode, optional communication interfaces are RS232, GPIB, USB.
RS232 Communication Set
This item configures the baud rate for serial communication. Possible values are 4800,9600,19200,38400,57600,115200.When operating the power supply in remote mode, make sure that you configure idential baud rate settings for the power supply and the computer.
Optional settings of parity bit for serial communication are NONE,ODD and EVEN. Default setting is NONE.
GPIB
This item set the communication address for GPIB interface. Avaialble range is 0-31.
USB
Select communication mode via USB interface.
Memory Group
You can store up to 36 different operating states in a nonvolatile memory space. All saved parameters are divided into four groups. They are Grp1,Grp2,Grp3 and Grp4. Each group can save 9 different operating states(1~9).
Command
This item set the communication protocol. Possible settings are SCPI,EXT1 and EXT2. Default setting is SCPI.
Return Meter
This item enable(“Wait5Sec”) or disable(OFF) the function to turn back to
meter state automatically. When select “Wait5Sec”,the display on front panel will automatically change to meter state under the condition of no operation within 5S.
Function and Features
Copyright © Itech Electronics Co., Ltd. 18
Reset
If you enter this menu and select “YES”, all parameters will be set to their default values.
Exit
Escape the menu.
System
This item set the max voltage and out timer of each channel. Choose one channel and set the parameters.
Max Volt
The max voltage you set should be within the range of 0V to the maximum rated voltage. You can edit this value using the , keys or via numerical
key pad followed by .The default setting is the maximum rated voltage for each channel.
Out Timer
This item sets the output timer for each channel. The range is 0.1~99999.9S.If you enable this function, and the output state of all channels is on, the timer will start counting down immediately. Once the timer expires(count down from set value to zero) the output of the assigned channel will turn off. To disable the timer, set the output time to zero. Default setting is 0 seconds.
Comb
This item configures the instrument connection mode. Off
Off” means that each channel operates independently. When set
successfully, front panel will display “Remove success!”
Series (Series mode)
This function configures the instrument for series operation of CH1 and CH2.Press button to confirm your set. And press to quit
the operation. When enable series connection mode, the front panel will indicate
Series success!” and escape this screen after 2S. Front display as follows in condition of output off and meter state.
Parallel (Parallel mode)
This function configures the instrument for parallel operations of three channels. Possible combination mode are CH1+CH2,CH2+CH3,ALL.
Press button to confirm your set.And press to quit the operation.
Enter
Enter
Esc
Enter
Esc
Function and Features
Copyright © Itech Electronics Co., Ltd. 19
Take CH2+CH3” as an example, press (Shift) + Menu
------Select Comb” and press to confirm.-------select
CH2+CH3” item and press to confirm.The front panel will indicate “Parallel Success!” and escape this screen after 2S.
Front display as follows in condition of output off and meter state.
Track (sync output setting)
This function configures the instrument for tracking operations of three channels. Possible combination mode are CH1+CH2,CH2+CH3,ALL.
Press button to confirm your set.And press to quit the operation.
In tracking mode,once the parameters of any one channel are changed,other channels will change proportionally.
For example, set voltage and current of CH1 and CH2 as follows, CH1: 4V, 1ACH2: 8V, 2A. Press (Shift) + Menu)into Menu, and press to select Comb, VFD will display as follows:
CH1+CH2 CH2+CH3 ALL
Select “CH1+CH2” and press to confirm. The VFD will display
Track Set Success!” and escape this screen after 2S.. Front display as follows in condition of output off and meter state.
For example: In setting status, if voltage of CH1 is set as 2V, voltage of CH2 will automatically change to 4V proportionally.
NOTE
Tacking function is disabled to the channel with 0V or 0A setting. In the former example,if CH2
setting is 0V or 0A, then when CH1 voltage is adjusted to 2V,CH2 will remain unchanged.
Parameters in Serial, Parallel or Tracking mode
Maximum voltage Operate “CH1+CH2” in series, the max voltage is 62V the sum of the max
voltage of CH1 and CH2. Operate CH1+CH2” in parallel, the max voltage is the smallest max voltage
of the two channels. It is 31V. Operate CH2+CH3” in parallel, the max voltage is the smallest max voltage
of the two channels, it is 6V.
I-setI-set
Enter
Enter
Enter
Esc
I-setI-set
Enter
Function and Features
Copyright © Itech Electronics Co., Ltd. 20
Operate CH1+CH2+CH3” in parallel, the max voltage is the smallest max voltage of the three channels. It is 6V.
In tracking mode, the max voltage is 31V. In serial, parallel and tracking mode, the out timer function will be disabled. In serial, parallel and tracking mode, the Save/Recall function will be disabled.
NOTE
When changed to serial, parallel or tracking mode, all channels will be OFF and voltage will be
reset to 0V. The channels configured to serial, parallel or tracking mode will be add a label of
“[ ]” in the display.
Power Information
Press (Shift) + , VFD will display power information; the information includes the following parts:
Power Model
Display the model of power supply: IT63XX
Soft Version
Firmware version of power supply: Ver=1.XX-1.XX
Power SN
Display the serial number of the power supply: SN:XXXXXXXXXXXXXXXXXX
Calibration information
Display calibration information: 2005-8-26 17:46:13
Error Information
If error, press (Shift) + , VFD will display error information, press any key to display the next error message, If not, then continue to display information on above(model, the software version, serial number, etc.) Error message will be cleared in the display, but fault still exist.
3.3 Channel Operation
When or button is lit, press (Local) key can switch between the three channels.
3.4 OUT ON/OFF
Pressing button toggles the output state of all 3 channes of the power supply.If the output state is ON,press it,to turn the output state to
OFF.While the output state is OFF,press and the power supply output will turn ON.
To control channels individually,press (Shift)+ , (Shift)+ (Shift)+ corresponding to each channel. (Shift)+ controls the output state of the first channel, (Shift)+ controls the output state of the second channel, (Shift)+ controls the output state of the third channel.
V-setV-set
I-setI-set
On/Off
On/Off
1
2
3
1
2
3
Function and Features
Copyright © Itech Electronics Co., Ltd. 21
When the power supply is in remote mode,you can set the output state by sending SCPI command(OUTPut: ON | OFF).The output state operation does not affect any other parameter.
NOTE
The key controls the output state of all 3 channels simultaneously. If you want to
control the output state of individual channels,use the number keys 1-3 with shift button.
3.5 Timer operation
If the “Out timer” is enabled for any channel In the menu, after the time set, the specified channel of the power supply will automatically switch to output off state. Please refer to Out Timer of chapter 3.2.
3.6 Set Voltage
Solution 1: press (Local) to select channel, press then enter
a numerical value followed by .
Solution 2: Press ,then press to move the cursor
position and adjust the voltage value using the knob. Press or
to exit.
Solution 3: Press ,then press to move the cursor
position and adjust the voltage value using . Press or
to exit.
NOTE
When output in OFF mode and button is dark, rotary knob and up/down keys
can’t be used to adjust voltage and current. If rotary knob is enabled, then adjusting it will
real-time change the current output setup without pressing to confirm.
3.7 Current Operation
Solution 1: press (Local) to select channel, press then enter
a numerical value followed by .
Solution 2: Press , then press to move the cursor
position and adjust the current value using the knob.Press or
to exit.
Solution 3: Press , then press to move the cursor
position and adjust the current value using . Press or
to exit.
On/Off
V-setV-set
Enter
V-setV-set
Esc
Enter
V-setV-set
Esc
Enter
MeterMeter
Enter
I-setI-set
Enter
I-setI-set
Esc
Enter
I-setI-set
Esc
Enter
Function and Features
Copyright © Itech Electronics Co., Ltd. 22
3.8 Save and Recall Operation
You can store up to 36 different operating states in memory locations 1 through 36.They are divided to four groups, each group includes nine different setups. Each operating state includes a constant voltage value, constant current value, maximum output voltage.
Press (Shift) + (Save) followed by a number key to save the current operating state to non volatile memory.
Press +number 1 to 9 to recall operating state assigned to this location.
You can also use the SCPI command(*SAV*RCL) to save and recall. When Save operation is done,there will be a corresponding information to
indicate the successful or failed operation.While for Recall operation,only information to indicate failed recall.
NOTE
The power supply doesn’t support Save/Recall operation when in serial/parallel or tracking
mode. If in serial/parallel mode and do Save/Recall operation, the VFD will display INV OPER
(invalid Operation) to remind the user of a wrong operation. If parameters want to be recalled
do not exist, the current value position on VFD will display -----, and then resume after 2S.
3.9 Key Lock Set
Press (Shift) + (Lock) can lock the front panel keys and label will be lit on the lower left corner
In key lock mode, all keys are disabled, except , , , ,
, (Local) and . (Shift)+ keys.
3.10 Protections
OVP operation
Select the channel-----press (Shift)+ (OVP)-----select “ON” and continue to set the OVP value.After set successfully,when the actual voltage is higher than OVP value,then VFD will display “OVER VOLT”.
Over Temperature Protection
If the internal temperature of the power supply exceeds 80,the instrument will protect itself by automatically turning power OFF. When this happens you will hear a buzzer and the display will indicate the following:
Over Temperature
Recall
Recall
On/Off
1
2
3
On/Off
MeterMeter
V-setV-set
Function and Features
Copyright © Itech Electronics Co., Ltd. 23
3.11 Remote sense function
Remote voltage sensing is used to maintain good regulation at the load and reduce the degradation of regulation that would occur due to the voltage drop in the leads between the power supply and the load. By connecting the supply for remote voltage sensing, voltage is sensed at the load rather than at the supply’s output terminals. This will allow the supply to automatically compensate for the voltage drop in the load leads and improve regulation.
+- output terminal, the same as front pane output terminals.
S+,S-: Remote sensing terminal.
Disable remote sense function:
1. Use the standard shorting clip which has been installed before leave the factory. Or you can also use wires to short S+” and +”,”S-“ and “-“.
2. Connect output +” and -“ to the load input terminals +” and -“.
Enable remote sense function:
1. Remove the shorting clip between “S+” and “+”,”S-“ and “-“.
2. Connect output +” and -“(front panel) to the load input terminals “+” and “-“.
3. Connect “S+” to “+” of the load, ”S-“ to the “-“ of the load.
NOTE
To ensure the system stability, please use twisted-pair cables between sense terminal and load.
Technical Specifications
Copyright © Itech Electronics Co., Ltd. 24
Chapter4 Technical Specifications
4.1 Major technical parameters
IT6322A/IT6322B
Parameters
CH1
CH2
CH3
Rated values
(0 °C - 40 °C)
Voltage
0~30V
0~30V
0~5V
Voltage limiting
0~31V
0~31V
0~6V
Current
0~3A
0~3A
0~3A
Power
90W
90W
15W
Load regulation
(of output + offset)
Voltage
≤0.01%+3mV
Current
≤0.1%+3mA
Line regulation
(of output + offset)
Voltage
≤0.01%+3mV
Current
≤0.1%+3mA
Setup resolution
Voltage
1mV
Current
1mA
Read-back resolution
Voltage
1mV
Current
1mA
Setup accuracy
(Within 12 months)
(25°C ± 5 °C)
(of output + offset)
Voltage
≤0.03%+10mV
Current
≤0.1%+5mA
Read-back accuracy
(25 °C ± 5 °C)
(of output + offset)
Voltage
≤0.03%+10mV
Current
≤0.1%+5mA
Ripple and noise
(20Hz-20MHz)
Voltage (Vp-p)
≤3mVp-p
Voltage (rms)
≤1mVrms
Current
≤3mArms
Output Temp. coefficient
(0 °C ~ 40 °C)
(of output + offset)
Voltage
≤0.03%+10mV
Current
≤0.1%+5mA
Read-back Temp. coefficient
(of output + offset)
Voltage
≤0.03%+10mV
Current
≤0.1%+5mA
Parallel setup accuracy
Voltage
≤0.02%+5mV
Current
≤0.1%+20mA
Memory
Save/recall
36 groups
Timer
Function
Output timer
Time set
0.1~99999.9 second
Resolution
0.1 second
Working temperature
0-40
Dimension (mm)
W×H×D
214.5mm×88.2mm×354.6mm
Technical Specifications
Copyright © Itech Electronics Co., Ltd. 25
IT6332A/IT6332B
Parameters
CH1
CH2
CH3
Rated values
(0 °C - 40 °C)
Voltage
0-30V
0-30V
0-5V
Voltage limiting
31V
31V
6V
Current
0-6A
0-6A
0-3A
Power
180W
180W
15W
Load regulation
(of output + offset)
Voltage
≤0.01%+3mV
≤0.01%+3mV
≤0.01%+3mV
Current
≤0.01%+3mA
≤0.01%+3mA
≤0.01%+3mA
Line regulation
(of output + offset)
Voltage
≤0.01%+3mV
≤0.01%+3mV
≤0.01%+3mV
Current
≤0.01%+3mA
≤0.01%+3mA
≤0.01%+3mA
Setup resolution
Voltage
1mV
1mV
1mV
Current
1mA
1mA
1mA
Read-back
resolution
Voltage
1mV
1mV
1mV
Current
1mA
1mA
1mA
Setup accuracy
(Within 12 months)
(25°C ± 5 °C)
(of output + offset)
Voltage
≤0.03%+10mV
≤0.03%+10mV
≤0.03%+10mV
Current
≤0.1%+8mA
≤0.1%+8mA
≤0.1%+5mA
Read-back accuracy
(25 °C ± 5 °C)
(of output + offset)
Voltage
≤0.03%+10mV
≤0.03%+10mV
≤0.03%+10mV
Current
≤0.1%+8mA
≤0.1%+8mA
≤0.1%+5mA
Ripple and noise
(20Hz-20MHz)
Voltage (Vp-p)
4mVp-p
4mVp-p
3mVp-p
Voltage (rms)
1mVrms
1mVrms
1mVrms
Current (rms)
5mArms
5mArms
4mArms
Output Temp. coefficient
(0 °C ~ 40 °C)
(of output + offset)
Voltage
0.03%+10mV
0.03%+10mV
0.03%+10mV
Current
0.1%+5mA
0.1%+5mA
0.1%+5mA
Read-back Temp. coefficient
(of output + offset)
Voltage
0.03%+10mV
Current
0.1%+5mA
Parallel setup
accuracy
Voltage
≤0.02%+5mV
Current
≤0.1%+30mA
Memory
Save/recall
36 groups
Timer
Function
Output timer
Time set
0.1-99999.9 second
Resolution
0.1 second
Working temperature
0-40
Dimension (mm)
W×H×D
214.5mm×88.2mm×453.1mm
Weight (net)
15Kg
Technical Specifications
Copyright © Itech Electronics Co., Ltd. 26
IT6333A/IT6333B
Parameters
CH1
CH2
CH3
Rated values
(0 °C - 40 °C)
Voltage
0-60V
0-60V
0-5V
Voltage
limiting
61V
61V
6V
Current
0-3A
0-3A
0-3A
Power
180W
180W
15W
Load regulation
(of output + offset)
Voltage
≤0.01%+3mV
≤0.01%+3mV
≤0.01%+3mV
Current
≤0.01%+3mA
≤0.01%+3mA
≤0.01%+3mA
Line regulation
(of output + offset)
Voltage
≤0.01%+3mV
≤0.01%+3mV
≤0.01%+3mV
Current
≤0.01%+3mA
≤0.01%+3mA
≤0.01%+3mA
Setup resolution
Voltage
1mV
1mV
1mV
Current
1mA
1mA
1mA
Read-back resolution
Voltage
1mV
1mV
1mV
Current
1mA
1mA
1mA
Setup accuracy
(Within 12 months)
(25°C ± 5 °C)
(of output + offset)
Voltage
≤0.03%+10mV
≤0.03%+10mV
≤0.03%+10mV
Current
≤0.1%+5mA
≤0.1%+5mA
≤0.1%+5mA
Read-back accuracy
(25 °C ± 5 °C)
(of output + offset)
Voltage
≤0.03%+10mV
≤0.03%+10mV
≤0.03%+10mV
Current
≤0.1%+5mA
≤0.1%+5mA
≤0.1%+5mA
Ripple and noise
(20Hz-20MHz)
Voltage (Vp-p)
4mVp-p
4mVp-p
3mVp-p
Voltage (rms)
1mVrms
1mVrms
1mVrms
Current (rms)
4mArms
4mArms
4mArms
Output Temp.
coefficient
(0 °C ~ 40 °C)
(of output + offset)
Voltage
0.03%+10mV
0.03%+10mV
0.03%+10mV
Current
0.1%+5mA
0.1%+5mA
0.1%+5mA
Read-back Temp. coefficient
(of output + offset)
Voltage
0.03%+10mV
Current
0.1%+5mA
Series setup resolution
Voltage
0-99V --- 1mV
--
100-120V --- 10mV
Current
1mA
--
Series Read-back
resolution
Voltage
0-99V --- 1mV
--
100-120V --- 10mV
Current
1mA
--
Parallel setup accuracy
Voltage
≤0.02%+10mV
Current
≤0.1%+30mA
Memory
Save/recall
36 groups
Timer
Function
Output timer
Time set
0.1-99999.9 second
Technical Specifications
Copyright © Itech Electronics Co., Ltd. 27
Resolution
0.1 second
Working temperature
0-40
Dimension (mm)
W×H×D
214.5mm×88.2mm×453.1mm
Weight (net)
15Kg
*The above specifications may be subject to change without prior notice.
Communication with PC
Copyright © Itech Electronics Co., Ltd. 28
Chapter5 Communication with PC
IT6322B/IT6332B/IT6333B Standard configuration have three communication interface: RS232 USB and GPIB, IT6322A/IT6332A/IT6333A Standard configuration have two communication interface: RS232 and USB. The user can choose any one to realize the communication with the computer. The following content can help you understanding how to through the computer control power supply output.
5.1 RS232 interface
The power rear panel has a DB9 needle mouth. Using both for the COM (DB9) cable connect computer. Press (Shift) + (Menu), setting menu of
configuration the same as the computer configuration before Activation connection. RS-232 interface can use all of the SCPI command to programming.
NOTE
In the procedure, the RS-232 must be set consistently with the front panel system menu set. If
you want to change, please press (Shift)+ (Menu) and access to menu to
change.
RS-232 data format
RS-232 data is a start bit and a stop bit 10 words. Start bit and the number of stop bits can not be edit. However press (Shift)+ Menu
and you can choose the following parity item. Parity options are stored in nonvolatile memory.
Baud rate
Press (Shift)+ Menu), under the system menu, you can select a baud rate which is stored in nonvolatile memory:
4800/9600/19200/38400/57600/115200
RS-232 connection
RS-232 serial port can connect with controller serial port by using a piece of RS-232 cable with DB-9 interface.(such as PC). The following table shows the
plug of the pin. If your computer connect with RS-232 interface with DB-25 plug, you need a
cable and a adapter which one aspect of the matter is DB-25 plug the other end is DB-9 plug.
Base pin number
Description 1
No conjunction
2
TXD, data transmission
I-setI-set
I-setI-set
I-setI-set
I-setI-set
Communication with PC
Copyright © Itech Electronics Co., Ltd. 29
RS232 Pins of Plug
3
RXD, data receiving
4
No conjunction
5
GND, grounding
6
No conjunction
7
CTS, clear to send
8
RTS, request to send
9
No conjunction
RS-232 troubleshooting
If you are having trouble communicating over the RS-232 interface, check the following:
The computer and the power supply must be configured for the same
baud rate, parity, number of data bits, and flow control options. Note that the power supply is configured for 1 start bit and 1 stop bit (these values are fixed).
The correct interface cables or adapters must be used, as described
under RS-232 Connector. Note that even if the cable has the proper connectors for your system, the internal wiring may be incorrect.
The interface cable must be connected to the correct serial port on your
computer (COM1, COM2,etc.).
Communication settings
Before communication, you should first make the following parameters of power supply and PC matches.
Baud Rate: 9600 (4800/9600/19200/38400/57600/115200). You can enter the system menu from the front panel, and then set the baud rate.
Data bits: 8 Stop bit: 1 Parity: (none, even, odd)
EVEN Eight data bits have even check ODD Eight data bits have odd check NONE Eight data bits have no check
The machine address: (0 ~ 31, the factory a value of 0)
Parity=None
Start Bit
8 Data Bits
Stop Bit
5.2 USB interface
You can connect the power and computer by using a USB cable with an A type port and a B type port. All the power function can programmed through the USB.
The power supply USB488 interface functions are described as follows: Interface is 488.2 USB488 interface.
Communication with PC
Copyright © Itech Electronics Co., Ltd. 30
Interface receive the request of REN_CONTROL, GO_TO_LOCAL, and
LOCAL_LOCKOUT.
Interface receive command information about MsgID = TRIGGER
USBTMC and pass on TRIGGER order to function layer.
The power USB488 device function are described as follows
Equipment can read all the forced SCPI command. Equipment is SR1 enabled. Equipment is RL1 enabled. Equipment is DT1 enabled.
5.3 GPIB interface
First of all, you should make power supply GPIB port connecting to computer GPIB card through the IEEE488 bus. Make sure the connect is firmly and then set the address, power supply address range is: 0 ~ 31.You can Enter the
system menu functions by pressing (Shift)+ (Menu). You can find GPIB address settings through pressing and Input address, then press to confirm. GPIB address is stored in nonvolatile line storage.
I-setI-set
Enter
Appendix
Copyright © Itech Electronics Co., Ltd. 31
Appendix
Specifications of Red and Black Test Lines
ITECH provides you with optional red and black test lines, which individual sales and you can select for test. For specifications of ITECH test lines and maximum current values, refer to the table below.
Model
Specification
Cross section
Length
IT-E301/10A
10A
-
1m
IT-E301/30A
30A
6mm2
1.2m
IT-E301/30A
30A
6mm2
2m
IT-E301/60A
60A
20mm2
1.5m
IT-E301/120A
120A
50mm2
2m
IT-E301/240A
240A
70mm2
1m
IT-E301/240A
240A
70mm2
2m
IT-E301/360A
360A
95mm2
2m
For maximum current of AWG copper wire, refer to table blow.
AWG
10
12
14
16
18
20
22
24
26
28
The Maximum current value(A)
40
25
20
13
10 7 5
3.5
2.5
1.7
Note: AWG (American Wire Gage), it means X wire (marked on the wire). The table above lists current capacity of single wire at working temperature of 30°C. For reference only.
Contact Us
Thanks for purchasing ITECH products. In case of any doubts, please contact us as follows:
1. Refer to accompanying data disk and relevant manual.
2. Visit ITECH website:www.itechate.com