IT Concepts Digital Video Recorder, iRis Operation Manual

1
Operation Manual
iRis 360°
Digital Video Recorder
Zoom: 1.0x F lip: N Integr :Standa rd 11.9 100%
2
3
4
Content
Preamble ............................................... 5
Warning Notices and Precautions ......... 6
Scope of Delivery ................................... 8
Overview iRis ........................................................... 9
The Control Panel .................................................. 11
Preparing the iRis
Charging the Battery .............................................. 12
Working with Mains Supply .................................... 13
Inserting the SD Card ............................................. 14
Starting Inspection
Switching-on the iRis ............................................. 15
Status Indicator Line .............................................. 15
Switching-On the LED Light Source ....................... 15
Language Selection ............................................... 16
Format SD Card ..................................................... 17
Setting Time and Date ........................................... 18
Image Control ........................................................ 19
Turning the Display ................................................. 20
Controlling the Articulation ..................................... 20
Changing and Adjusting the Objective .................... 21
Putting the Side View Tip Adapter .......................... 21
Passing Turns ........................................................ 22
Retracting the Endoscope ...................................... 23
Creating and saving Image Captures
Choosing a Standard Setting ................................. 24
Inserting Text ......................................................... 25
Image Capture and Video Recording
in Mode „OFF“ ....................................................... 26
Image Capture and Video Recording
in Mode „ON“ ........................................................ 27
Comparative Measuring with the iRis .....29
Playback of saved Images and
Video Recordings ....................................30
Optimising Camera Settings
Camera Setting ...................................................... 33
Camera Setting Standard ....................................... 34
Camera Setting Short Integration ........................... 35
Camera Setting Long Integration ............................ 36
Camera Setting Manual .......................................... 37
Maintenance ........................................ 38
Storage ................................................ 40
Spare Parts and Accessories ............... 41
Service ................................................. 43
Technical Specifications ....................... 43
Declaration of Compliance with CE ..... 45
5
We congratulate you on buying your iRis DVR 360° Industrial Videoscope, in the following just named iRis. It unites Light Source, TFT Display plus Image Storage and Video Recording Device.
The diversity of inspection objects, materials and lightning conditions often makes it difficult to get high-quality images. It is easy to adjust the iRis to your application to receive optimal inspection images even in extreme situations.
Always keep the Operation Manual with the iRis. It contains all information for safe and efficient operation. However, should you have further questions, feel free to contact our Service Team.
Preamble
Online Store - store.itcworld.de
6
Read the Operation Manual carefully before using the iRis.
Caution! The iRis has to be employed by skilled and qualified personnel appropriate to the application. The iRis is designed for a diversified field of applications in Industry, Building and Science. Only use the iRis as intended.
Caution! Never use the iRis in running machines.
Caution! The iTool has not to be used in specially designated or prohibited areas (e.g. Explosion Prevention).
Electric Shock! No unauthorised opening of the casing. There is high danger of electric shock due to parts being under voltage. For higher abrasion resistance the flexible and bendable probe is sheathed with tungsten. This can lead to electric shock at contact with
live parts. Therefore the iRis is never to be used in or at objects under tension.
Caution! Never look directly into the light emitting part of the iRis. It can cause injuries of eyes. Always switch off the Light Source before changing, controlling or cleaning the objective or the distal end of the Videoscope.
Caution! Use the iRis in dry environments only. According IP53 the housing is protected against splash water. The housing if the iRis is never to be immerged in water or cleaned directly under running water.
Caution! Using mains adapter without earth conducter and without galvanic isolation can lead to a tungsten braid being under electric tension. Therefore only use mains supplies delivered with the iRis.
Warning Notices and Precautions
Online Store - store.itcworld.de
7
Caution! If the objective is dirty the distal end may heathen up. This can lead to igniti­on of highly combustible materials. Further­more it can lead to burns at direct contact. Regular cleaning should be made.
Caution! When inspecting hot objects the probe may heat up according ambient tem­perature. Avoid direct contact to the probe after such applications – High risk of burns.
Do not throw battery into fire. Do not recharge defect battery, but replace it immediately.
The iRis is an electric device and must not be disposed in domestic waste. Pursuant to European Directive 2002/96/EG on waste electrical and electronic equipment (WEEE) and its transposition to national law used up power tools have to be collected separately and returned to environmentally compatible recycling.
Recycling. Withdrawal of batteries pur­suant to the Battery Policy: According to the German Battery Policy (BattV) we are obliged to inform you about the rules and liabilities for disposal and withdrawal of used batteries and accumulators. According to §7 German Battery Policy the end-user is obli­ged to return used batteries and accumula­tors. Contaminant-laden batteries and accu­mulators are marked with a crossed dustbin with the chemical symbol of the contained heavy metal under it (Cd for cadmium, Hg for mercury, Pb for lead). Batteries and ac­cumulators must not be disposed in dome­stic waste and can be handed free of charge to any designated collection and withdrawal point. Of course batteries and accumulators you got from IT Concepts can be handed or sent to us.
Warnhinweise und Vorsichtsmaßnahmen
Online Store - store.itcworld.de
8
The iRis is delivered with the components shown in adjacent images.
Further interchangeable objectives or additional acces­sories are not included. These items you will find in this manual on page 42ff., in our accessories catalogue or on our homepage www.itcworld.de. We are certainly pleased being at your disposal for personal consulting as well.
Scope of Delivery
Online Store - store.itcworld.de
Rec harge able Batt ery (in devi ce w hen d elive red)
Cha rgerLen s Box
Ope ratio n Ma nual
Nec k Hol derITC Case Poc ket
Zoom: 1.0x Fl ip: N Integr: Standar d 11.9 100%
9
Live and saved images as well as video recordings are shown on the TFT Display. Image captures and video recordings can be marked with overlay text. The probe can be inserted to a cavity, e.g. a tube. The user can lock the articulating head of the probe in the desired position during
inspections. The articulation can be moved in four directions (up/down and left/right) which really facilitates passing multiple co­vings.
System Presentation
Edge Protector
3,5“ TFT VGA Colour Display
Pins for Neck Holder
Lever (up/down)
SD Card Slot
(under Edge Protector)
Control Panel
integrated LED
Light Source
Lever (left/right)
Online Store - store.itcworld.de
Zoom: 1.0x Fl ip: N Integr: Standar d 11.9 100%
10
System Presentation
The region to be inspected has to be that large that movements with the diameter and length of the articulating part are possible and don’t result in seizing. The sheathing of the insertion tube is made of tungsten netting and particular increases the durability of the flexible probe. The
inspection area can be illuminated with the integrated LED Light Source.
ON/OFF LED Light Source
12V DC Plug
Cinch OUT for Hard Disk, Monitor, etc.
Handle
Battery Compartment
Swivel Lock Mechanism
Capture Button
Online Store - store.itcworld.de
11
Online Store - store.itcworld.de
System Presentation
The Control Panel
Using the control panel you can navigate through the menu structure, select and confirm functions.
POWER
Switching-on or off the device
OK-BUTTON
Confirming action/Image capture
ARROW KEYS
Navigate (up/down) / Zoom in and out
ARROW KEYS
Navigate (left/right) / Adjusting brightness
MENU
Open/Close on-screen menu
MEMORY
Open/Close Memory Mode
RECORD/ CANCEL
In Live Mode: Start/Stop video recording / In Memory Mode: Quit submenu
FREEZE/ CAPTURE
Pause video recording / Freeze image / Image capture
12
System Presentation
Charging the Battery
Before charging please pay attention to the included manual for the charger. For charging the accumulator has to be removed from the housing. For this the cover of the battery compartment has to be detached by releasing the locking screw.
To charge the battery place it in the charger. Charging process is finished when charge indicator lamp conti­nuously glows green. Caution! Only use the delivered charger to charge the battery. Otherwise there is high risk of damages to the cells.
The operating voltage is shown in the status indicator line on the iRis display. The fully charged battery is placed in the device when delivered.
Battery Compartment
Cover Battery Compartment
Rec harge able Batt ery (in devi ce w hen d elive red)
Cha rger
Battery
Online Store - store.itcworld.de
13
Preparing the iRis
Online Store - store.itcworld.de
Working with external Power Supply
As an option the iRis can be powered as follows:
1) AC Adapter + Power Supply Cable Item Nr.: 820-00001-003-V
2) PowerBelt Item Nr.: 900-06000-0030-V
3) Car Battery Cable Item Nr.: 900-05000-0004
4) Cigarette Lighter Cable Item Nr.: 900-00002-0012
Note: The 12V DC plug as well as the socket is marked with a red dot. Assure that both red dots are visibly opposed when connecting the 12V DC plug to the iRis.
14
Preparing the iRis
Inserting the SD Card
Slightly remove the right edge protector and put a formatted SD Card (32GB max.) into the card slot. The SD Card included in the scope of delivery is already inserted and properly formatted.
If the SD Card is not formatted you have to format it as described on page 17.
Online Store - store.itcworld.de
15
Online Store - store.itcworld.de
Switching-on the iRis
After having prepared the iRis according this operation manual switch it on by pressing POWER. Please inspect the iRis probe as described on page 40 before inserting the endoscope into the inspection object!
Status Indicator Line
At start-up the iRis always is in Live Mode. At the bottom of the display the status indicator line can be seen. It shows the status of zoom, image flip, camera, power supply and light intensity.
Switching-on the LED
The LED is switched on or off by a long push on the Light Source Button. With short push the intensity of the LED can be adjusted in three steps.
Starting Inspection
Zoo m: 1.0x F lip: N In tegr:St an dard 11.9 1 00%
Zoom: 1.0x F lip: N Integr: Standar d 11.9 100%
16
Language Selection
At delivery status the iRis should already be set to your language or to English.
At initial operation you should check if the appropriate language is set and adjust if necessary. The following languages are available:
English (default setting) – German – French – Spanish – Italian
If you want to change the language set proceed as follows:
• MENU
• System Setting - OK
• Select language –
the menu will immediately be shown in the selected language.
• To quit press MENU again
Starting Inspection
Online Store - store.itcworld.de
St atus Lin e : ON Fr eeze Fra me : OFF La ngua ge : Eng lish Da te/Tim e : Pre ss O K SD inf o : Pre ss O K SD for mat : Pres s OK Fa bric Set ting s : Pre ss O K So ftwa re S tatu s : P01 0 55 Se rial Num ber : 2011081 5
La ngua ge : En glis h
Im age Cont rol Ca mera Con trol An nota tion Di mens ion Sy stem Set ting Sa fety rem ove SD
Sy stem Set ting
17
Format SD Card
The SD Card delivered with the iRis is already formatted. To format a SD Card proceed as follows:
Press MENU, select menu item System Setting and press OK. Using the arrow keys select the menu item Format SD and press OK. A confirmation prompt appears on the display. Select via arrow keys and confirm with OK.
Starting Inspection
Im age Cont rol Ca mera Con trol An nota tion Di mens ion Sy stem Set ting Sa fety rem ove SD
Sy stem Set ting
St atus Lin e : ON Fr eeze Fra me : OFF SD for mat : Pres s OK Da te/Tim e : Pre ss O K SD inf o : Pre ss O K SD for mat : Pres s OK Fa bric Set ting s : Pre ss O K So ftwa re S tatu s : P01 0 55 Se rial Num ber : 2011081 5
SD for mat : Pr ess O K
18
Setting Time and Date
In the delivery status time and date should already be set.
At initial operation you should check time and date and set them if necessary.
If you want to change time and/or date proceed as follows:
Press MENU, select menu item System Setting and press OK. Using the arrow keys select menu item Date/Time and press OK. Set the desired time and date via the arrow keys and then confirm by pressing OK.
Starting Inspection
Online Store - store.itcworld.de
Im age Cont rol Ca mera Con trol An nota tion Di mens ion Sy stem Set ting Sa fety rem ove SD
Sy stem Set ting
St atus Lin e : ON Fr eeze Fra me : OFF SD for mat : Pres s OK Da te/Tim e : Pre ss O K SD inf o : Pre ss O K SD for mat : Pres s OK Fa bric Set ting s : Pre ss O K So ftwa re S tatu s : P01 0 55 Se rial Num ber : 2011081 5
Da te/Tim e : Pr ess O K
19
Resetting to Default Settings
By selecting the menu item Fabric Settings all manually changed and adjusted parameters can be put back to factory setting, except for date, time and text generator.
– MENU – System Setting - OK – Fabric Settings - OK
You are in Live-Mode again afterwards.
Starting Inspection
Im age Cont rol Ca mera Con trol An nota tion Di mens ion Sy stem Set ting Sa fety rem ove SD
Sy stem Set ting
St atus Lin e : ON Fr eeze Fra me : OFF La ngua ge : En glis h Da te/Tim e : Pre ss O K SD inf o : Pre ss O K SD for mat : Pres s OK Fa bric Set ting s : Pre ss O K So ftwa re S tatu s : P01 0 55 Se rial Num ber : 2011081 5
Fa bric Set ting s : Pr ess O K
20
Image Control
Image parameter (brightness, contrast and colour as well as zoom and image flip) can be adjusted under Image Control in the menu.
Change the select parameter by using the arrow keys. New settings will immediately be effective. Pressing OK will reset the marked parameter to default set­ting. Using the MENU button will bring you back to Live Mode.
Caution! The image parameter are effective to the image displayed as well as to images and videos being saved. Image captures and video recordings will be saved as displayed.
Starting Inspection
Online Store - store.itcworld.de
Im age Cont rol Ca mera Con trol An nota tion Di mens ion Sy stem Set ting Sa fety rem ove SD
Im age Cont rol
Br ight ness
|| || || ||| || || ||. .. .. ... .. .. ..
5
0%
Cont rast
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
Colo ur
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
Zoom
|
.. .. .. ... .. .. ... .. .. ... .. .. .
1x Flip Nor mal
Dimm en
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
Br ight ness
|| || || ||| || || ||. .. .. ... .. .. ..
50 %
21
Turning the Display
By lifting the locking ring under the rubber cover the detent of the display is released. Now the display can be turned in two directions.
Controlling the Articulation
The articulation section can be moved in two planes by means of the levers on the handle (see fig.). If the levers are released during movement the articulation section will be locked in the current position.
On the image the levers are shown in „neutral“ home position. In this position the articulation section is straighten.
Starting Inspection
Online Store - store.itcworld.de
22
Changing and adjusting Objectives
Different interchangeable objectives are available for the iRis (except 4mm). Therefore an optimal field of view and f-stop can be chosen at any time. The objectives are differently coloured to discern them easier.
The objectives can be adjusted and exchanged by using the lens tool. The working distance is conti­nuously adjustable by screwing the objective in or out the distal end. For easier adjusting the lens tool is equipped with an adjusting hole. Through that hole you can check the image during adjustment in live mode.
It is recommended to adjust the objective to the re­quired working distance before starting the inspec­tion. The working distance gets farther by turning the objective into the distal end.
Caution! Never turn in the objective with force.
Mounting the Side View Tip Adapter
If a lateral view is necessary (e.g. in tubes or narrow cavities) a 90° Side View Tip Adapter can optionally be mounted. Depending on diameter of the scope the adapter is available with different working dis­tances. With 6 and 8mm probe it is simply screwed into the distal end after having removed the objec­tive and on the distal end without removing the ob­jective at 4mm probes. Do not torque the Side View Tip down with force and never use tools (e.g. tongs) for it.
Starting Inspection
Online Store - store.itcworld.de
23
Passing Covings
Size and covings of the object to be inspected have to be large enough to allow the movements of the articulating part and the distal end. The feasibility should be verified visually or by means of design drawings before the inspection. The actions descri­bed in the following have to be carried out at every coving analogue to the described procedure. If a resistance or any other problem occurs retract the probe carefully.
Fig. A
Carefully push the probe to the beginning of the coving while observing on the display.
Fig. B
Still observing on the display adapt the articula­ting section to the coving of the cavity by using the levers.
Fig. C and D
Continue the insertion process while always ob­serving on the display. The angle of the articula­ting section has to be adapted step by step to the coving of the object. After having passed the coving the articulating section has to be straightened by putting the levers to neutral position.
Starting Inspection
Online Store - store.itcworld.de
A
B C
D
24
Retracting the Endoscope
To retract the endoscope the articulating section has to be straighten first, i.e. the levers have to be put to neutral position.
By observing on the display and appropriate movement of the levers an equal distance of the distal end to the walls of the cavity has to be kept. Avoid contacts of the distal end with the walls of the sur­rounding.
At resistance during the retraction it is recommended to slightly twist the probe in both senses around its longitudinal axis and at the same time carefully push and pull until the probe is released again.
Caution! Put both levers to neutral position (as shown) before retracting the scope!
Caution! Put both levers to neutral position (as shown) before retracting the scope!
Starting Inspection
Online Store - store.itcworld.de
Neutrale Position
25
There are two standard settings available. Decide whether you want to work in Mode Freeze Frame ON or OFF for image captures and video recordings (see pages 27-29) before starting the inspection.
Press MENU, select the menu item System Setting and press OK. Using the arrow keys select Freeze Frame and choose ON or OFF.
Creating and saving Image Captures and Video Recordings
Online Store - store.itcworld.de
Im age Cont rol Ca mera Con trol An nota tion Di mens ion Sy stem Set ting Sa fety rem ove SD
Sy stem Set ting
St atus Lin e : ON Fr eeze Fra me : OFF La ngua ge : En glis h Da te/Tim e : Pre ss O K SD inf o : Pre ss O K SD for mat : Pres s OK Fa bric Set ting s : Pre ss O K So ftwa re S tatu s : P01 0 55 Se rial Num ber : 2011081 5
Fr eeze Fra me : OF F
26
Online Store - store.itcworld.de
Inserting Text
With the text generator you have the possibility to mark all images with a text commentary (a single line of 31 characters). Please insert text before saving the image.
Press MENU, select menu item Annotation and press OK,
Use the arrow keys to select the desired charac­ter and press OK. To quit and save the text press RECORD, to quit without saving press MENU. You can delete single characters by pressing FREEZE.
Creating and saving Image Captures and Video Recordings
Im age Cont rol Ca mera Con trol An nota tion Di mens ion Sy stem Set ting Sa fety rem ove SD
An nota tion
27
Creating and saving Image Captures and Video Recordings
Direct Image
Capture
Start / Stop
Video
Recording
During recordings single images
can be saved as follows:
Online Store - store.itcworld.de
Standard Setting Nr. 1 „Freeze Frame OFF“
28
Creating and saving Image Captures and Video Recordings
Direct Image
Capture
Image freezes Frozen is displayed on the screen
Image freezes Frozen is displayed on the screen
Back to
Live Mode
Save
Image
Save
Image
1 x short push
Save
Image
Push 1 x
1 x long push
Back to
Live Mode
1 x short push 1 x long push
Online Store - store.itcworld.de
Standard Setting Nr. 2 „Freeze Frame ON“
29
Video
Recording
Start/Stop
recording
Push 1 x
Save
image
Press 1 x
Save
image
1 x short push
Pause/Continue
recording
Press 1 x
Pause/Continue
recording
1 x short push
Start
recording
Stop recording
Press 1 x
Online Store - store.itcworld.de
Text - Optionally
insert in advance
(see page 26)
30
The iRis provides the possibility of point-to-point measuring within the image. This can be used in the Live Mode as well as in the Memory Mode.
Press MENU on the keypad. Select the menu item Dimension, select Calibration confirming with OK each time - two flags appear on the display. The distance in pixels is shown in the status indicator line.
Before you can use the Comparative Measuring you need to make a calibration as follows: Hold the distal end in your defined working distance to an object of known size (e.g. ruler). Move the active flag (displayed in white) to one side of the geometry. Press OK to switch between the flags and lead the second flag to the end of the geometry. When both flags are on the desired positions, press MENU twice, choose Dimension and Calibration afterwards, always confirming with OK. Please insert the measure as value in front of the “:“ and the unit (e.g. mm) behind of it. To save and quit Caibration press RECORD. To quit without saving press MENU. After having pressed RECORD the inserted unit appears in the display, while being
in Live Mode with visible flags. Now you may save as usual (see pages 27-29). Your measuring value occurs in the saved image and video recording.
Calibrating and Comparative Measuring with the iRis
Zoom: 1.0x F lip: N Integr: Standar d 11.9
100_ :
012 3456 78 9 ., : !?
_ ABCD EF GHI JKLM _ _ NOPQ RS TUV WXYZ _
arro ws - move cu rsor
<OK> - ad d symbo l
<REC ORD> - close editor, save t he chan ges
<MEN U> - close e ditor, ca ncel t he chan ges
<FRE EZE> - delet e last right s ymbol
+
+
Online Store - store.itcworld.de
31
You can access all saved data.
The iRis System saves images and video recordings automatically to the SD Card as follows:
Image: Format: bmp Resolution: 640 x 480 pixel Location: Folder Picture
Video: Format: avi Resolution: 800 x 600 pixel LOCATION: Folder HVR
Name: All files (image as well as video recording) are named by the system. Each image and video gets an automatically created file name consisting of date and time.
Playback of saved Images or Video Recordings
Online Store - store.itcworld.de
4.000 MM 2011/04/05 10:25:45
IT CONCEPTS INSPEKTION
+
+
32
How to access les.
Press MEMORY to access the Browser Mode. Navi- gate through the folder structure to the desired le by using the arrow keys and the OK button
Note! The LED Light Source is automatically swit- ched-off in Memory Mode and reactivated when changing to Live Mode again.
Playback of saved Images or Video Recordings
BROWSER /SD/
HVR
[1] Folders
0 File, 0KB
HVR
PICTURE
BROWSER /SD/HVR/
File Browser
H VR
0429
HVR
[1] Folders
0 File, 0KB
0430
BROWSER /SD/HVR/0430
File Browser
H VR
11
HVR
[1] Folders
0 File, 0KB
10
Online Store - store.itcworld.de
33
Images
After having accessed the desired le you can con- trol it as follows by using the arrow keys and the OK button:
OK = Open/Flip image Arrow keys = Leaf for- and backwards Cancel = back to browser
Video Recordings
After having accessed the desired le you can con- trol it as follows by using the arrow keys and the OK button:
OK = Start / Stop / Pause video Left = rewind Right = Fast forward Cancel = Quit
Furthermore you may select additional functions through the context menu.
Playback of saved Images or Video Recordings
BROWSER /SD/HVR/0430/10
File Browser
T20111910172205.AVI 5MB
HVR
[1] Folders
0 File, 0KB
T20111910172301.AVI 5MB
Icon View
Online Store - store.itcworld.de
34
Camera Setting
The camera settings help to optimal adjust the videoscope or camera to your application to get perfect images.
In addition to the STANDRAD setting the iRis System provides three other camera settings:
SHORT INTEGRATION LONG INTEGRATION MANUAL INTEGRATION
Press MENU, select the menu item Camera Control and press OK. Choose the desired camera setting by using the arrow keys.
Optimising Camera Settings
Ka mera eins tell ung : Sta ndar d Dete ctor Type : M ean Manu al S hutt er
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
Manu al G ain
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
A GC L evel
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
Gamm a
|| || |
.. .. .. ... .. .. ... .. .. ... .
+2
Whit e Ba lanc e : Press OK
Im age Cont rol Ca mera Con trol An nota tion Di mens ion Sy stem Set ting Sa fety rem ove SD
Ca mera Con trol
I nteg rati on : St anda rd
Online Store - store.itcworld.de
35
Camera Setting STANDARD
The standard setting is approved for a variety of applications to get clear and expressive inspection images.
This setting produces an automatic optimising of the camera settings.
In this setting you can influence two further parameter:
White Balance
The white balance can only be executed in the camera setting STANDARD.
How colours of an image or video recording are displayed is depending on the colour temperature of the light source. For optimal colour reproduction it is required to make a white balance.
1. Place the distal end of the videoscope in front of a white non-reflecting sheet of paper.
2. Switch on the light source
3. Put the distal end in a position where no irradi­ations are visible in the picture.
4. Select the menu item White balance and hold the OK button until the white balance is carried out.
Gamma
With Gamma the video signal is corrected regarding brightness and contrast.
Optimising Camera Settings
Online Store - store.itcworld.de
Ka mera eins tell ung : Sta ndar d Dete ctor Type : M ean Manu al S hutt er
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
Manu al G ain
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
A GC L evel
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
Gamm a
|| || |
.. .. .. ... .. .. ... .. .. ... .
+2
Whit e Ba lanc e : Press OK
I nteg rati on : St andar d
36
Camera Setting SHORT INTEGRATION
The camera setting Short Integration is particularly recommended for inspections with disadvantageous (dark) lighting conditions.
This setting provides an optimal live image by means of a high signal gain and a long exposure time. This allows a particular well orientation in the hollow during inspections.
Detector Type
Here you have the choice between two modes:
Mean Detector: The camera control system detects the brightness of the whole image (multi-zone measu­ring) and adjusts the signal brightness based on the AGC-level and the brightness measured.
Peak Detector: The camera control system adjusts the image brightness depending on the brightest line detected. Application: Better perceptibility of details in image areas with high brightness.
AGC Level (Auto Gain Control): This features adjusts the optimal image brightness with the brightness ad­justment level being predefined by the AGC Value (high value = high gain).
Gamma
With Gamma the video signal is corrected regarding brightness and contrast.
Optimising Camera Settings
Ka mera eins tell ung : Sta ndar d Dete ctor Type : M ean Manu al S hutt er
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
Manu al G ain
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
A GC L evel
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
Gamm a
|| || |
.. .. .. ... .. .. ... .. .. ... .
+2
Whit e Ba lanc e : Press OK
I nteg rati on : Sh ort i nteg rati on
Online Store - store.itcworld.de
37
Camera Setting LONG INTEGRATION
The camera setting Long Integration is particularly recommended for image captures and video recordings with very disadvantageous (dark) lighting conditions.
With the distal end fixed this setting provides optimal image captures and video recordings
Detector Type
Here you have the choice between two modes:
Mean Detector: The camera control system detects the brightness of the whole image (multi-zone measu­ring) and adjusts the signal brightness based on the AGC-level and the brightness measured.
Peak Detector: The camera control system adjusts the image brightness depending on the brightest line detected. Application: Better perceptibility of details in image areas with high brightness.
AGC-Level (Auto Gain Control): This features adjusts the optimal image brightness with the brightness ad­justment level being predefined by the AGC Value (high value = high gain).
Gamma
With Gamma the video signal is corrected regarding brightness and contrast.
Optimising Camera Settings
Online Store - store.itcworld.de
Ka mera eins tell ung : Sta ndar d Dete ctor Type : M ean Manu al S hutt er
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
Manu al G ain
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
A GC L evel
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
Gamm a
|| || |
.. .. .. ... .. .. ... .. .. ... .
+2
Whit e Ba lanc e : Press OK
I nteg rati on : Lo ng in tegr atio n
38
Camera Setting MANUAL
The camera setting Manual gives you the possibility to individually change the camera setting without the influence of the automatic camera control system.
Manual shutter
Setting image brightness by adjusting the relative exposure time of the sensor. This allows image capture at poor lighting conditions.
Manual gain
Setting image brightness by adjusting the signal gain. But this will increase electric signal noise and reduce image quality.
Gamma
With Gamma the video signal is corrected regarding brightness and contrast.
Optimising Camera Settings
Online Store - store.itcworld.de
Ka mera eins tell ung : Sta ndar d Dete ctor Type : M ean Manu al S hutt er
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
Manu al G ain
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
A GC L evel
|| || || ||| || || ||
.. .. .. ... .. .. .
50 %
Gamm a
|| || |
.. .. .. ... .. .. ... .. .. ... .
+2
Whit e Ba lanc e : Press OK
I nteg rati on : Ma nual
39
Gehäuse
Sonde
Basics
The following procedures have to be carried out after each use of the iRis. A want of care can lead to corrosion and damages. The grade of the required cleaning depends on the degree of pollution.
Cleaning the Housing
Clean the housing with a soft and moist cotton cloth. If necessary use mild detergent and dry carefully afterwards. Do not clean display or housing under running water or immerse in liquids!
Cleaning the Probe
Wipe off dust and dirt with a soft cotton cloth. Wash the flexible part with a moist sponge. Dry with a clean and soft cotton cloth after cleaning.
The distal end has to be cleaned with cotton swabs (Q-Tip®) soaked with high-proof alcohol. Do not use rough cloths for cleaning!
Cleaning and Care
Online Store - store.itcworld.de
40
Inspecting the iRis Probe
The probe of the iRis has to be controlled regarding visible external damages before every use. Further­more the objective’s surface has to be checked and cleaned if necessary (see page 39).
The manoeuvrability of the articulating section has to be checked: First push the lever U/D towards the housing and move it from one extreme position to the other, so that the articulation moves in an angle ca. +160° to ca. -130° in the vertical plane.
Then bring the lever back to the neutral position and release it. Analogical move the lever R/L, so that the articulation moves in an angle of ca. ±100° in the horizontal plane. Bring the lever back to the home position afterwards and release it.
At occurrence of any problem stop operating and contact the Customer Service of IT Concepts (see page 37).
Cleaning and Care
Online Store - store.itcworld.de
41
Storing the System
The System needs to be dry and cleaned for storage. The levers have to be brought to neutral position.
Carefully insert the probe into the reel in the case. Push the probe slowly into the reel until you are able to place the housing in the corresponding recess without bending the probe too much. Afterwards push the rest of the probe thoroughly into the reel until the probe is securely placed and cannot be damaged by the case or any accessories. Avoid bending the probe to an arc radius less than 45mm.
In case of storing the system outside the transport case it should be hung at the housing. The storing location should be protected against humidity, direct sunlight and high temperature fluctuation. At hanging take care that the probe hangs free and doesn’t butt at something.
Storage
42
Spare Parts and Accessories
iRis Accessories
830-00001-0003 SD Memory Card 900-00003-0009 Neckholder 900-00002-0025 iRis DVR Clamp 900-05000-0036 Li-Ion rechargeable Battery NC2040A24 900-05000-0037 Charger for Li-Ion rechargeable Battery NC2040A24 820-00001-0003-V iRis AC Adapter 12V DC / 5,50A 900-06000-0050 iRis Case 860-00003-0003 Lens Box for Objective Lenses 900-00003-0013 ITC Case Pocket
Accessories Description Colour code f-Stop DOV FOV Working Distance 930-00100-0004-V 4.0mm Side View Tip Adapter (only for 60°-Version) 90° 60°
930-00200-0012-V 4.0mm Side View Tip Adapter Tool 90° 60° 930-00200-0008-V 6.0mm Lens Tool 930-00100-0002-V 6.0mm Side View Tip Adapter 1:5.2 90° 60° 5.0mm - 15.0mm 930-00100-0003-V 6.0mm Side View Tip Adapter 1:5.2 90° 90° 7.0mm - infinity 930-00200-0006-V 6.0mm Objective Lens RED 1:4.3 90° 7.0mm - infinity 930-00200-0007-V 6.0mm Objective Lens BLACK 1:5.2 90° 7.0mm - infinity 930-00200-0005-V 8.0mm Lens Tool 930-00100-0001-V 8.0mm Side View Tip Adapter 1:6.4 90° 60° 5.0mm - infinity 930-00200-0013-V i8 Adjustment Tool for 8.0mm SVTA 930-00100-0001-V 8.0mm Objective Lens RED 1:7.6 90° 5.0mm - infinity 930-00200-0002-V 8.0mm Objective Lens SILVER 1:3.9 90° 5.0mm - infinity 930-00200-0003-V 8.0mm Objective Lens BLACK 1:7.0 60° 10.0mm - infinity 930-00200-0009-V 8.0mm Objective Lens GOLD 1:2.5 60° 8.0mm - infinity 930-00100-0004-V 8.0mm Objective Lens BLUE 1:5.3 28° 25.0mm - infinity
Online Store - store.itcworld.de
43
To help us to efficiently execute any maintenance or repair of the product please directly contact us.
Thank you!
Contact
Fon: + 49 (0) 6441 679299 - 0 Fax: + 49 (0) 6441 679299 - 99
IT Concepts GmbH Gewerbestr. 17 D-35633 Lahnau
www.itcworld.de service@itcworld.de
Service
Online Store - store.itcworld.de
Technische Daten
Operating Unit
Display Size: 3,5“ (9cm) TFT Colour Display Resolution: VGA (640x480 Pixel) Operating System: Realtime operating System, with On-Screen-Menu User Interface: Direct Action Keys, Function-Keys, Arrow-Keys Languages: Englisch, French, Spanish, Italian, German Video interface: Composite Video-out Power Supply, primary: changable Li-Ion-Battery (Charger is provided) Power Supply, secondary: 12V Adapter
Measurement
Method Comparative Measurement Function
Documentation
Video Format: AVI (.avi) Image Format: BMP (.bmp) Storage: SD-HC-Memory Card up to 32GB (FAT32)
Camera Control
Image Sensor: High-Resolution Color SUPER HAD
TM
CCD Camera Control / Exposure: Integration modes: Automatic, Short, Long, Manuell White Balance: yes, factory default or user defined AGC-Level: yes, adjustable Gamma: yes, adjustable
Image Control
Zoom: x3.5 (Digital) Invert: horizontal and vertical Image Inversion Brightness, Contrast, Colour: yes, adjustable Text Annotation: Built-in full screen text overlay generator
44
Technische Daten
Illumination
Type: High-Power Whitelight-LED´s with fiber optic light guides Illumination Control: yes, 3-steps Colour Temperature: ca. 6500k Average Lamp Lifetime: ca. 5000h
Probe
Diameter: 4.0mm 6.0mm 8.0mm Working Length: 4.9 - 13.1ft (1.5 - 4.0m) 4.9 -13.1ft (1.5 - 7.5m) 4.9 - 13.1ft (1.5 - 7.5m) Articulation: 4-way (Control Levers) 4-way (Control Levers) 4-way (Control Levers) Articulation Angle* L/R | U/D: 100°/100° | 100°/100° 100°/100° | 160°/130° 100°/100° | 160°/130° Integrated Objective Lens: x - ­Interchangeable Objective Lens: - x x Side View Tip Adapter: o
(only with Int. Objective Lens) x x
Braid: Tungsten Braid on PU-Jacket
Construction
Ergonomics: ± 90° rotatable Display Unit, alt. ±90° rotatable Scope Handle System Weight: 2.97lb (1.35kg) Operating Unit Dimensions: 370mm x 175mm x 75mm Housing: rugged PU, with integrated rubber shock caps Frame: Alloy Protection Class: IP53
Operating Environment
Tip Operating Temperature: +14°F to 176°F (-10°C to +80°C) System Operating Temperature: -13°F to 115°F (-25°C to +45°C) Storage Temperature: -13°F to 115°F (-25°C to +45°C) Relative Humidity: 95% max. - non condensing Waterproof: Probe and distal end up to 14,7 psi (1 bar- 10,2 m H
2
O)
Hazardous Environments: Not rated for use in hazardous environments
Interchangeable Objective Lenses & SVTA
Probe DOV FOV DOF CODE ART. NR.
4,0mm 60° 7-50mm ­4,0mm 60° 4-10mm SD ­4,0mm 90° 15mm-∞ ­4,0mm 90° 10-30mm SD ­4,0mm** 90° 60° 5-45mm SVTA 930-00100-0005 6,0mm 60° 5mm-∞ BLACK 930-00100-0002 6,0mm 90° 5mm-∞ RED 930-00200-0006 6,0mm** 90° 60° 5-15mm SVTA-CF 930-00100-0002 6,0mm** 90° 60° 15-50mm SVTA-FF 930-00100-0003 8,0mm 28° 25mm-∞ BLUE 930-00200-0004 8,0mm 60° 8mm-∞ YELLOW-B 930-00200-0009 8,0mm 60° 10mm-∞ BLACK 930-00200-0003 8,0mm 90° 5mm-∞ SILVER-B 930-00200-0002 8,0mm 90° 5mm-∞ RED 930-00100-0001 8,0mm** 90° 60° 5mm-∞ SVTA 930-00100-????
DOV = Direction of View CF = Close Focus FOV = Field of View FF = Far Focus DOF = Depth of Focus B = Bright objective lens SVTA = Side View Tip Adapter ** Compatible to FOV60 °
!
Online Store - store.itcworld.de
45
CE Konformitätserklärung
We declare of our own responsibility that this product (iRis 360° DVR Art.Nr.: 900-03001-0002) complies with the following directive or normative documents:
EN61326-1 (2006) Emission and Immunity, according to directive 2004/108/EG Electromagnetic Compatibility (see image).
Lahnau, 2011-04-13
Online Store - store.itcworld.de
46
Notizen
47
48
© 2011 IT Concepts GmbH. All rights reserved. This Operation Manual corresponds to the status at the time of going to print. IT Concepts accepts no liability for any printing errors contained herein. Design subject to change. We reserve the right of making technical changes at any time. No sections of this Operation Manual may be reprinted, photo-mechanically, mechanically or digitally copied or reproduced without the express approval of IT Concepts GmbH.
IT Concepts GmbH
Gewerbestr. 17
D-35633 Lahnau
Fon: + 49 6441 679299 - 0
Fax: + 49 6441 679299 - 99
www.itcworld.de
info@itcworld.de
Version: itc-iRis dvr - operation - manual - om - 2011 05 05 – 01
Loading...