ITC TQ-40, T-6707, TS-234, T-319 Operation Manual

Page 1
Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.
CAR AMPLIFIER
TQ-40
OPERATION MANUALOPERATION MANUAL
PUBLIC ADDRESS SYSTEM
Page 2
1. SAFETY PRECAUTIONS .......................................................................................3
2. FEATURES ...............................................................................................................5
3. NOMENCLATURE AND FUNCTIONS
3.1 Front Panel ............................................................................................................ 6
3.2 Rear Panel..............................................................................................................7
4. APPLICATIONS .......................................................................................................8
6. SPECIFICATIONS ................................................................................................10
5. CONNECTIONS .......................................................................................................9
2
Page 3
Be sure to read the instructions in this section carefully before use. Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded as very important precautions are included. We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling. Before operating your product, read this manual first and understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage.
When Installing the Unit
Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the power supply cord. In addition, avoid using the power cord in close proximity to heaters, and never place heavy objects -- including the unit itself -- on the power cord, as doing so may result in fire or electric shock.
Be sure to replace the unit's terminal cover after connection completion. Because high voltage is applied to the speaker terminals, never touch these terminals to avoid electric shock.
Be sure to ground to the safety ground (earth) terminal to avoid electric shock. Never ground to a gas pipe as a catastrophic disaster may result.
Avoid installing or mounting the unit in unstable locations, such as on a rickety table or a slanted surface. Doing so may result in the unit falling down, causing personal injury and/or property damage.
When the Unit is in Use
Should the following irregularity be found during use, immediately switch off the power, disconnect the power supply plug from the AC outlet and contact your nearest dealer. Make no further attempt to operate the unit in this condition as this may cause fire or electric shock. If you detect smoke or a strange smell coming from the unit. If water or any metallic object gets into the unit If the unit falls, or the unit case breaks If the power supply cord is damaged (exposure of the core, disconnection, etc.) If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor remove the unit case as there are high voltage components inside the unit. Refer all servicing to your nearest dealer.
ITC
ITC
Do not place cups, bowls, or other containers of liquid or metallic objects on top of the unit. If they accidentally spill into the unit, this may cause a fire or electric shock.
Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit's cover, as this may result in fire or electric shock.
1. SAFETY PRECAUTIONS
3
Page 4
An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in the electrical installation of the building.
When Installing the Unit
Never plug in nor remove the power supply plug with wet hands, as doing so may cause electric shock.
When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord itself. Operating the unit with a damaged power supply cord may cause a fire or electric shock.
When moving the unit, be sure to remove its power supply cord from the wall outlet. Moving the unit with the power cord connected to the outlet may cause damage to the power cord, resulting in fire or electric shock. When removing the power cord, be sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover. Doing so may cause heat to build up inside the unit and result in fire.
Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the heaters, or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and/or property damage. In addition, the object itself may fall off and cause injury and/or damage.
Make sure that the volume control is set to minimum position before power is switched on. Loud noise produced at high volume when power is switched on can impair hearing.
Do not operate the unit for an extended period of time with the sound distorting. This is an indication of a malfunction, which in turn can cause heat to generate and result in a fire.
Contact your dealer as to the cleaning. If dust is allowed to accumulate in the unit over a long period of time, a fire or damage to the unit may result.
ITC
If dust accumulates on the power supply plug or in the wall AC outlet, a fire may result. Clean it periodically. In addition, insert the plug in the wall outlet securely.
Switch off the power, and unplug the power supply plug from the AC outlet for safety purposes when cleaning or leaving the unit unused for 10 days or more. Doing otherwise may cause a fire or electric shock.
SAFETY PRECAUTIONS
4
Page 5
2. FEATURES
5
1. 2*20W mini car amplifier.
2. Two microphone inputs MIC1, MIC2 and one AUX input.
3. The sensitivity of MIC1, MIC2 is 5mV and can be connected by dynamic MIC; AUX sensitivity is 350mV that can be connected by CD, FM and other sources.
4. MIC1, MIC2 volume can be adjusted independently .
5. 12-16V DC power supply is powered directly from the battery with power on indicator.
6. The power output :4 / 2*20W.
7. With overload, overheating protection function automatically .
8. Nice appearance, novel structure, convenient installation.
Page 6
3.1 FRONT PANEL
1.
2.
3.
4.
AUX input MIC1 input MIC2 input MIC1 volume potentiometer
3. NOMENCLATURE AND FUNCTIONS
2
6
1
3
4
5 6
5. .
7.
MIC2 volume potentiometer
6 Power Indicator
Power Switch
MIC 1MIC 1
MIC 2MIC 2AUX
TQ-40
CAR AMPLIFIER
POWER
OFF ON
0 10 0 10
7
Page 7
7
3. NOMENCLATURE AND FUNCTIONS
3.2 REAR PANEL
8.
9. 12V
Fuse DC input terminal
10. Speaker output terminal
11. Handheld MIC
DC 12V
T8AL 250V
OUT 1(4 ) OUT 2(4 )
8 9 10
11
Page 8
4. APPLICATIONS
8
Page 9
5. CONNECTIONS
9
MIC 1MIC 1
MIC 2MIC 2AUX
TQ-40
CAR AMPLIFIER
POWER
OFF ON
0 10 0 10
DC 12V
T8AL 250V
OUT 1(4 ) OUT 2(4 )
CD/FM MUSIC OUTPUT
Page 10
6. SPECIFICATIONS
Model
MIXER PRE-AMPLIFIERMIXER PRE-AMPLIFIER
TQ-40
Working temperature
Audio sources
Frequency Response
THD
S/N Ratio
AUX input sensitivity
MIC input sensitivity(unbalanced)
Speaker inpedance & rated power
CD, FM and MIC etc.
80Hz~16KHz (+1dB/-3dB)
1%
>70dB
350mV Industry standard pressure line terminals
5mV
4 ,2x20W(two channel) Industry standard pressure line terminals
540
DC Power
Dimensions
Weight
DC 12~16V
Power Consumption
Working humidity
20% 80% relative humidity, without condensation
1.5Kg(include Handheld MIC )
179x144x50mm
45W
10
Page 11
PUBLIC ADDRESS SYSTEM
VersionV0.1
Loading...