Italray MOEBT03 OPERATOR MANUAL

OPERATOR MANUAL
Code MOEBT03
VIA DEL PARLAMENTO EUROPEO, 9D – I-50010 SCANDICCI (FI) - TEL. ++39-0557228511 - FAX ++39-0557228512
ELECTROMEDICAL RADIOLOGICAL EQUIPMENT
www.italray.it info@italray.it
BT
MOEBT03
MANUAL DATA
REVISIONE REVISION MOEBT03 - VALID STARTING FROM S/N 11-130-05
PREPARATO PREPARED RICCARDO SARTI
VERIFICATO CHECKED STEFANO BALDINI
APPROVATO APPROVED STEFANO BALDINI
DATA DI EMISSIONE ISSUE DATE 10/01/06
REVISION INDEX
MOEBT00
13/07/98 MOEBT01 – General revision
24/04/2003 MOEBT02 - New Italray’s telephone number
10/01/06 MOEBT03 – New revision of the device.
Part Number:
S/N.
TYPE CODE / PART NUMBER REVISION
FOLLOWING PRODUCT EQUIPMENT DOCUMENT
DOCUMENTATION ATTACHED TO THE MANUAL
OPERATOR MANUAL
Page 2 of
8
BT
MOEBT03
CAUTION !
Carefully read the contents of this manual before starting the equipment.
Although this equipment is designed and constructed respecting the most up-to-date safety standards, the X-ray source always constitutes a danger when the operator is not qualified or informed. Excessive exposure to X-rays causes bodily damage.
Therefore all precautions must be taken to avoid unauthorized and unqualified persons using this apparatus so constituting a danger to themselves and others.
Before carrying out any operation, the persons qualified and authorized to use this equipment must be informed about the protection measures established by the International Commis­sion on Radiological Protection and the relevant national standards.
The X-ray emission control point must be in a zone screened from radiation.
If it is necessary to move into the immediate equipment area during an exposure, put on X-ray protection garments.
The company refuses all liability for consequences following interventions made by unau­thorized personnel.
The equipment must not be used for any purposes other than those intended.
The company refuses all liability if authorized personnel do not adhere to the requirements contained in this manual during the performance of their tasks.
If abnormalities or malfunctions occur that cannot be resolved as indicated in this manual the authorized person is to consult the equipment manufacturer for the necessary relevant in­structions:
ITALRAY s.r.l.
Via del Parlamento Europeo 9/D – 50010 - Scandicci – Florence - ITALY Telephone +39 055 7228511 Fax +39 055 7228512 E-mail info@italray.it Website www.italray.it
OPERATOR MANUAL
Page 3 of
8
BT
MOEBT03
Index
1 INTRODUCTION ................................................................................................................................................................4
2 DESCRIPTION....................................................................................................................................................................4
3 TECHNICAL DATA............................................................................................................................................................4
4 INSTRUCTIONS FOR USE ..............................................................................................................................................6
5 CLEANING, ROUTINE AND NON-ROUTINE MAINTENANCE ................................................................................7
6 OVERALL DIMENSION ...............................................................................................................................................8
1 INTRODUCTION
This manual provides the user with instructions for correct equipment use.
The equipment must not be used for purposes other than those intended.
The user is responsible for fulfilling legal obligations regarding the installation and the
functioning of the equipment itself.
The manufacturer cannot be considered liable for any breakage, malfunction or bodily
damage if the equipment is not operated correctly, or is not suitably maintained.
2 DESCRIPTION
The extremely flat, particularly suitable for use with traumatized and disabled patients. The x-ray table, floating in all directions, can be released by a optical foot switch in the front of the bot­tom part.
is a horizontal bucky table with 75 cm hight from the floor patient table. X-ray table
BT
3 TECHNICAL DATA
The equipment meets the following directives :
Directive 93/42/EEC (Class I)
Directive 89/336/EEC and later amendments.
and the following technical standards:
IEC EN 60601-1 (Class I type B) and later amendments.
IEC EN 60601-1-2
IEC EN 60601-1-3
IEC EN 60601-2-32
The device meets the European Environmental Directives 2002/95/EC, 2002/96/EC and 2003/108/EC
OPERATOR MANUAL
Page 4 of
8
BT
Technical features Dimensions of the x-ray table 2200 x770 mm Height from floor 750 mm Longitudinal travel 1000 mm Transversal travel 130 + 130 mm Distance x-ray table - film 68 mm Longitudinal travel of potter 400 mm Maximum allowable weight 180 Kg Weight of the device 140 Kg Power supply 220Vac +/- 10% 50/60 Hz Absorption 1 A Al equivalence (stratified table standard) 0,85 mm aluminium Al equivalence (carbon fibre table top) (optional) 0,4-0,5 mm aluminium
Transport and storage conditions Temperature : -10° to +70° C Humidity : 20 to 80%
Operating environment conditions Temperature : +10° to +40° C Humidity : 30 to 75%
MOEBT03
Bucky
- Motorized grid movement (with variable speed in factory)
- Grid ratio 1:10 D.F.F. 120. Inch scales 103 standard grid, other type on request. Close to the unlock bucky bottom there is the greed specifications.
- Cassette holder, manual self-centring.
IDENTIFICATION An identification data plate is positioned above left indicating equipment code, serial number and other necessary information.
Via del P. Europeo 9/D - 50010 SCANDICCI (Firenze) ITALY tel.+39 055 7228511 fax.+39 055 7228512
e-mail: info@italray.it web: www.italray.it
Type B
EN60601-1
class I
Device name
Type
Serial n°
Power supply
Manuf. year
TRO+IR101/A-A
220Vac +/- 10% 50/60 Hz
BT
nn-nnn-nn
2006
When requesting maintenance or replacement parts it is always necessary to give this infor­mation.
OPERATOR MANUAL
Page 5 of
8
BT
MOEBT03
ACCESSORIES ON REQUEST
- Ionization chamber for automatic exposure meter.
- Grid to customer's specifications.
- “Potentiometer” kit for automatic Bucky tracking.
- Patient compression band.
DISPOSAL OF MATERIALS
- Packing:
Wood and bubble sheet 100% recyclable
- Assembly materials :
Carbon steel 100% recyclable Elastomers and plastic materials 100% recyclable Cables and other electrical materials
The equipment must not be disposed of as normal urban solid waste, it must be taken to an expert waste disposal centre and in conform with the local laws in force.
4 INSTRUCTIONS FOR USE
Bucky unlock switch,
push it to allow the
bucky movement. Push
again to brake the bucky
Optical unlock brake, introduce a foot in to the indicate space to unlock
all patient table brake.
Remove the foot to
brake it again
Fig 1
OPERATOR MANUAL
Page 6 of
8
BT
Fig 2
Operating sequence
Put an x-ray cassette charged In to the cassette holder (see fig 2)
Position the patient on the patient table.
MOEBT03
Cassette holder
Cassette clamp with automatic centring
Unlock the table brake with foot introduction in to the optical sensor zone
Move the patient and centre the interesting zone with the cassette under the table
Push the bucky switch to allows the bucky movement (push again after movement to
brake it)
Centre the x-ray source with the anatomical part of the patient and the film cassette
After all centre operation perform the X-ray exposure following all the Radiological Pro-
tection rules.
Remove the cassette after the exposition.
5 CLEANING, ROUTINE AND NON-ROUTINE MAINTENANCE
Only clean the table and the lateral cover surfaces using a slightly dampened cloth and
neutral detergent, dry with a dry cloth,
do not
etc.), corrosive and abrasive agents. Do not use acids to clean the floor.
The routine and non-routine maintenance must be carried out only by the manufacturer's
personnel or personnel authorized by them, and following the maintenance manual. Rou­tine maintenance is to be made annually.
The company refuses all liability following interventions by persons other than those de­scribed above.
use solvents (benzine, alcohol, acetone,
OPERATOR MANUAL
Page 7 of
8
BT
6 OVERALL DIMENSION
MOEBT03
Via Del Parlamento Europeo 9/D 50010 Scandicci Firenze
tel. +39/055/7228511 fax. +39/055/7228512
www.italray.it email info@italray.it
OPERATOR MANUAL
Page 8 of
8