itaia FM-1, Photometer FM-1 Operating Manual

Operating manual
Photometer: FM-1
Litostrojska cesta 44/d, SI-1000 Ljubljana T +386 (1) 514 18 00, F +386 (1) 514 18 04 info@itaia.si, www.itaia.si
ELECTRONICS
RESEARCH
DEVELOPMENT
Table of Contents
1. SAFETY INFORMATION AND CAUTION .......................................... 1
1. 1. G
ENERAL
.................................................................................................. 1
1. 2. F
IRE-EXTINGUISHING GEAR
...................................................................... 2
1. 3. S
AFETY PRECAUTIONS
.............................................................................. 2
2. GUIDELINE FOR CONNECTION AND USE OF PHOTOMETER .. 4
2. 1. F
IELD OF USE
............................................................................................ 4
2. 2. M
OUNTING AND PLACEMENT
.................................................................... 4
2. 3. C
ONNECTIONS
........................................................................................... 4
2. 4. O
NBOARD INDICATORS
............................................................................. 6
2. 4. 1. Use of 230 V AC Contactor Outputs .............................................................. 6
2. 4. 2. Use of U/I Analog Outputs ............................................................................. 7
2. 5. C
ALIBRATION
............................................................................................ 8
3. PC SOFTWARE »STREET LIGHT VISION« ........................................ 9
3. 1. S
ETTING UP PC COMMUNICATION
.......................................................... 10
3. 2. W
RITING DATA TO THE PHOTOMETER
.................................................... 10
3. 3. R
EADING DATA FROM THE PHOTOMETER
............................................... 11
4. MAINTENANCE ..................................................................................... 12
4. 1. C
HECKING AND MAINTENANCE
.............................................................. 12
4. 2. S
ERVICING
.............................................................................................. 12
4. 3. T
ROUBLESHOOTING
................................................................................ 13
4. 4. S
PARE PARTS
........................................................................................... 13
5. TECHNICAL SPECIFICATIONS ........................................................ 14
5. 2. T
RANSPORT AND STOCKING
.................................................................... 15
5. 3. D
ISPOSAL
................................................................................................ 15
6. CE DECLARATION OF CONFORMITY ........................................... 15
Operating manual: PHOTOMETER FM
-
1
1
1. Safety Information and Caution
1. 1. General
The device, connected and used in accordance with following instructions, is safe to use. All electrical parts are protected against water, dust and dirt by the relevant IP class. Housing prevents direct contact with any parts under voltage.
!
BEFORE MOUNTING AND CONNECTING THE DEVICE READ MANUAL CAREFULLY!
!
THE CONNECTING OF DEVICE MUST BE CARIED OUT BY QUALIFIED PERSONNEL!
!
WHEN CONNECTING, DISCONNECT ELECTRICAL POWER FIRST!
!
DO NOT BLOCK ACCESS TO ELECTRICAL PARTS USED FOR EMERGENCY STOP, CLEANING AND MAINTENANCE!
!
ALL METAL PARTS OF HOUSING MUST BE GROUNDED!
!
MAKE SURE THAT WATER DOES NOT GET IN TOUCH WITH PARTS UNDER VOLTAGE!
Connecting of the device must be done by qualified personnel and in accordance with local standards. After mounting and connection control measurements must be carried out to ensure safe and correct operation.
! CAUTION: For any injury resulting from improper use, the user takes full responsibility.
!
Operating manual: PHOTOMETER FM
-
1
2
1. 2. Fire-extinguishing Gear
In case of fire use CO2 based fire extinguisher and other equipment following procedures in accordance with fire-safety regulations.
1. 3. Safety Precautions
Safety precautions are meant to provide personal safety and long service life of device. Any person take part of mounting, connecting or maintenance of the device must follow this manual and local safety regulations. They have to be qualified for the job and use appropriate technical equipment.
Before starting:
Disconnect circuit breakers at input and output of the device and make
sure there is no voltage present.
Make sure power is disconnected during the time of mounting and
connecting.
Check the voltage presence with an instrument.
Check grounding connection.
Provide protection against touching the parts under voltage.
Qualified Personnel
Transport, mounting, connecting, commissioning and maintenance of the device can only be preformed by personnel:
with job qualification and experience,
familiar with up to date safety standards and
with knowledge of basic working principles of the device.
Responsibility
We take no responsibility for proper operation and any consequences resulting from use in discordance with this manual. Safety measures must be provided by user working with device.
In case of malfunction, please, provide us following information:
type of the device,
serial number,
errors detected,
overall time of operation,
environmental conditions and
application information.
Operating manual: PHOTOMETER FM
-
1
3
Our Technical Support
Litostrojska cesta 44/d, SI-1000 Ljubljana T +386 (1) 514 18 00, F +386 (1) 514 18 04
info@itaia.si, www.itaia.si
Declaration of Conformity
The device complies with relevant European directives (CE declaration of conformity):
– Electromagnetic compatibility (ULRS, no. 132/2006)
Directive 2004/108/EC and its amendments
– Low voltage Directive (ULRS, no. 27/04)
Directive 2006/95/EC and its amendments
Operating manual: PHOTOMETER FM
-
1
4
2. Guideline for Connection and Use of Photometer
2. 1. Field of Use
Photometer is designed for measuring and regulating illumination in traffic areas. Using it we can provide adequate road ilumination at any time and any light conditions. It's primary application is illumination control for tunnels and under passes based on L20 measurement according to CIE standard. Photometer FM-1 is provided with analogue U/I output for PLC or tunnel SCADA connection. For local illumination control 4-channel 230 V AC programmable outputs are available. Measuring range, output channel switching and time averaging interval are PC programmable using software provided.
2. 2. Mounting and Placement
Photometer comes with wall fixture. Pole fixture is also available
(optional)
. For light conditions measuring at the entrance of the tunnel, install the photometer at the stopping distance before the entrance portal. It should be mounted at height approx. 4,5 m and pointed directly to the entrance of the tunnel. When mounting on the pole, make shure, the pole has proper grounding! For in-tunnel light conditions measuring
(allways choose full stainless-steel-housing option)
, the photometer should be pointed to the spot one reach in 3 seconds at maximum allowed speed. In this case the driver’s view cannot be simulated very accurately due to mounting height versus distance, hence the measuring result must be adopted by multiplying with a constant
(usually between 1.05 and 1.20)
. Once mounted, undisturbed view field must be provided for the photometer. There should be no disturbing objects, either any light sources or light reflecting objects in it's view field vicinity. Any of these can considerably affect the measuring accuracy.
2. 3. Connections
Photometer is connected to the mains power supply 230 V AC and to the tunnel light controlling system. Cables with 3-7 leads at minimum 0.75 mm2 must be used for 230 V AC power supply and contactor outputs. For analogue U/I output and communication coaxial 2-3 lead data cable is recommended. Maximum connection distance is up to 400 metres. For parametric setup connect the photometer with personal computer and run software. Connection distance can be up to 20 metres for RS-232
(200 m for RS-485 –optional)
.
All necessary connectors are accessible by removing rear cover (
see Pictures 1, 2 and Table 1
). After final connection and successful commission tighten well all cable glands and place provided desiccant bag in the photometer housing pushing it towards front window. Make sure it is not touching any electrical part!
Operating manual: PHOTOMETER FM
-
1
5
Picture 1: Connectors behind the rear cover
pin port voltage description
1
L-
power
230 V AC
power
2
PWR
ground / grounding
3
N-
power
230 V AC
power
4 out F 230 V AC
contactor out. F
5 out E 230 V AC
contactor out. E
6
contactor
out D 230 V AC
contactor out. D
7
out
out C 230 V AC
contactor out. C
8 out B 230 V AC
contactor out. B
9 out A 230 V AC
contactor out. A
10
PC
GND 0 V DC
programming/controll
11
RS 232
RX
±
12 V DC
programming/controll
12
/485
TX
±
12 V DC
programming/controll
13
TTL
f
out
0-5 V DC
frequency output
14
analog
GND 0 V DC
15
analog
I
out
4-20 mA current output
16
analog
U
out
0-10 V DC voltage output
Table 1: Pin out and description
Green/Red
r.A r.B r.C r.D
r.E r.F
out A out B out C out D
out E out F
1
9
power
supply /
6 Ch 230 V AC
contactor
output
PC RS-232/485
connection
analog
U/I output
16
131012
Fuse F 2,5 A
Loading...