1. Introduct ion
ISysmart SGZB11C, an infrared motion On-Off light switch with the temperature sensor, acts as an End Device in ZigBee network. It does not perform permit-join function as a coordinator or a router for other devices to join the network. Users can assign specific ON/OFF task to the binding devices according to different command. When SGZB11C, for example, detects the movement and the surrounding light intensity is low, it reports a light-on message. It also reports temperature periodically, and the time interval is configurable.
What is ZigBee?
ZigBee is a short range wireless transmission technology based on IEEE802.15.4 standard and supports multiple network topologies such as point-to-point, point-to-multipoint, and mesh networks. It is defined for a general-purpose, cost-effective, low-power-consumption, low-data-rate, and easy-to-install wireless solution for industrial control, embedded sensing, medical data collection, smoke and intruder warning, building automation and home automation, etc.
2. Product Appearance
Indicator (Red/ Green)
Binding Key Auxiliary Key
Infrared Sensor
Light Sensitivity Adjustor Sensor Sensitivity Adjuster
Release Button
3
3. Specification
Fully IEEE 802.15.4 compliant (ZigBee Pro) Utilizes 2.4GHz ISM band; up to 16 channels Power supply: 2 x ER14505 3.6V AA batteries Operating consumption: ≤ 45mA Standby consumption: ≤ 100uA Temperature Sensing Range: 0~60Sensing angle- horizontal: 110°; vertical: 60°; rotation: 40° Build-in tamper alarmUp to 70 meters wireless transmission range in non-obstacle spaceEasy installation and configuration
4. Installat ion
A mounting height between 2 and 2.2 meters is recommended.
Do not aim the passive infrared sensor to a heat or cold source.
The sensor should not face open door/windows as sunlight will affect its operation.
The sensor must be mounted on a vibration-free surface.
IR coverage range:
The coverage area A- Distance: 12 meters; sensing angle: 30°.
The coverage area B- Distance: 8 meters; sensing angle: 60°.
The coverage area C- Distance: 5 meters; sensing angle: 110°.
4
5
6
Double-sided stickers tips:
1. Clean two surfaces to stick with.
2. Tear sticker on one side; stick to the position shown product base, and smoothly press it.
3. Rip the remaining side and stick to the clean side of the wall (the direction of arrow
shows up ) and press firmly around 20 seconds.
Double-sided stickers
7
5. Setting up SGZB11C
5-1. Turn On/Turn Off SGZB11C
Under the circumstances SGZB11C is first time used or after resetting, when it is powered on and cannot successfully search a network, SGZB11C will go into turn-off mode.
To manually turn on or turn off SGZB11C, please use the following instructions:
A. Tur n it on: Press the Binding Key once. The indicators will flash once, and the device is ready
to be used.
B. Turn it off: Press and hold the Binding Key for 15 seconds. The indicator will keep flashing.
Release the Binding Key, and the device would be turned off.
It is recommended that having a 5-second interval between turning on and turning off SGZB11C to avoid the interruption between inductors and capacitors or so.
5-2. Join the ZigBee Network
After SGZB11C is turned on, it will search for an existing ZigBee network and send a request to join the network automatically. While SGZB11C is under the coverage from a coordinator or a router whose permit-join feature is enabled, SGZB11C will be permitted to join the network.
Step1. Enable the permit-join function (valid for 60 seconds) of a coordinator or a router (please
refer to the user manual of the coordinator or the router to enable the permit-join feature). Step2. Turn on SGZB11C. It will start to search and join the network. Step3. The indicator will flash green once when it finds out a network to join. Step4. The indicator will flash green 5 times after it is joined successfully. Otherwise, the indicator
will not flash.
5.3. Enroll in the ZigBee Security System
SGZB11C is a Zone device in the ZigBee security system. Right after SGZB11C join the ZigBee network, it will automatically fi nd out a CIE ( Contro l and Ind icatin g Equi pment) dev ice (i.e . ISysmart Z201B) and send a registration request to the CIE device to enroll in the security system. The enrollment has these 3 situations:
A. There is no CIE device or no compatible CIE device in the network → the indicator flashes
green twice.
B. There is a compatible CIE device in the network, but it is failed to enroll → the indicator flashes
green 4 times.
C. The enrollment is completed → the indicator flashes green 6 times.
NOTE: Users had better NOT enroll multiple Zone devices at the same time to prevent registration failure.
5-4. Binding
To make SGZB11C work with the devices which support IAS ZONE/ On/Off/ Temperature measurement, users need to bind the two devices:
Step1. Enable the binding feature of SGZB11C.
Press the Binding Key once → to broadcast the binding request for IAS ZONE Press the Binding Key twice within 5 seconds → to broadcast the binding request for On/Off Press the Binding Key 3 times within 5 seconds → to broadcast the binding request for Temperature measurement The indicator flashes green while the Binding Key is pressed.
Step2. Enable the binding feature of the IAS ZONE/ On/Off/ Temperature measurement devices. Step3. The indicator flashes green 5 times after the binding is completed; otherwise, it flashes green
10 times.
5-5. Sleeping Mode
SGZB11C is designed to go to sleeping mode for power-saving in some situations:
A. While the device is in the network → the sleepin g period is 5 minutes; it will wake up
every 5 minutes to keep online. B. When it doesn’t find a network to join → SGZB11C will g o to sleeping mode . It will wake up
every 15 minutes to search a network to join. C. Once SGZB11C was joined to a network and by any chance the network is no longer existed
or the device is out of the network → SGZB11C will wake up every 15 minutes to find the
network it joined before.
It never keeps in sleeping mode and continues to find out a network every 15 minutes. This condition would consume up to 30 times power spending compared to normal-operating status. To prevent this unwanted power consumption, we recommend that users remove the batteries to power off the device.
5-6. Wake up SGZB11C
When users would like to setup or acquire data from the device which is in sleeping mode, we have to wake up the device as the following steps:
Step1. Press the Auxiliary Key. Step2. The indicator flashes green 5 times when SGZB11C is online. Step3. SGZB11C will broadcast the device data to the ZigBee network.
9
SGZB11C would be in active status for 2 minutes for communication.
5-7. Battery
SGZB11C will send a low-power report to the ZigBee network when the operating voltage is lower than
3.2V by default. The related data:
Power configuration cluster (ID:0x0001) Battery voltage attribute (ID:0x0020)
The reporting voltage can be adjusted. There are 4 voltages for choosing: 3.5V/ 3.4V/ 3.3V/
3.2V. It is recommended that the minimal reporting internal is longer than 3-minute.
5-8. Infrared Sensor Detection and Report
When infrared sensor detects a movement, SGZB11C1 will send the report to the CIE device and go to Occupied status. The indicator will flash red once. In Occupied condition, SGZB11C1 will detect the further movement after 84 seconds (120 * 70%) by default. Until no additional movement is detected within the period of 120 seconds, SGZB11C1 will go to Unoccupied condition and send the report to ZigBee network.
After SGZB11C1 joins the ZigBee network, the infrared sensor will not be active within 1 minute. Under the circumstances SGZB11C1 is not in a ZigBee network, it will start to join a network after
the SGZB11C1 detects a movement.
Users could change the detecting sensitivity by adjusting the Sensor Sensitivity
Adjuster. Clockwise adjustment → Higher sensitivity
This device supports “Voltage status” and “Occupancy status” report.
For “Voltage status” report: (1) If ZB11D does not bind any device (ClusterId: 0001), it will not send report. (2) After binding, ZB11D will send voltage status to bind device.
Default configuration: Min: 3600s, Max: 3600s, Report change:1
For “Occupancy status” report: (1) If ZB11D does not bind any device (ClusterId: 0406), it will not send report. (2) After binding, ZB11D will send voltage status to bind device.
Default configuration: Min: 0s, Max: 3600s, Report change:0
Note: it is recommended to set MinInterval as small as possible such like “0” for immediately
detection and avoid missing IR detection report.
5-9. Movement Detection and On/Off Control
When infrared sensor detects the movement and the surrounding light intensity is lo w, it sends a light-on message. In this condition, SGZB11C will detect the further movement after 84 seconds (120 * 70%) by default.
Until no additional movement is detected within the period of 120 seconds, SGZB11C will send a light­off message.
Users could change the light sensitivity by adjusting the Light Sensitivity
Adjuster. Clockwise adjustment → Brighter
5-10. Tamper Alarm
SGZB11C features tamper alarm. When the cover is opened, SGZB11C will notify the central security unit, CIE (Control and Indicating Equipment) device, to send a command to a Warning Device.
5-11. Restore to Factory Setting
To restore it to factory setting, please follow the steps:
Step1. Press and hold the Auxiliary Key for 10 seconds. Step2. After the indicator shows fast green flashes, release the button to complete the restore.
7. Important Maintenance Instructions
Please keep the device in a dry place. Precipitation, humidity, and all types of liquids or moisture can contain minerals that corrode electronic circuits. In cases of accidental liquid spills to a device, please leave the device dry properly before storing or using.
Do not use or store the device in dusty or dirty areas.
Do not use or store the device in extremely hot temperatures. High temperatures may damage the device or battery. Do not use or store the device in extremely cold temperatures. When the device warms to its normal temperature, moisture can form inside the device and damage the device or battery. Do not drop, knock, or shake the device. Rough handling would break it. Do not use strong chemicals or washing to clean the device.
Do not paint the device. Paint would cause improper operation.
Handle your device, battery, and accessories with care. The suggestions above help you keep your device operational. For damaged device, please contact the authorized service center in your area.
FCC Statement:
This device compl ies with part 15 of the FCC Rules. Operation is subject to the follow ing two conditions: (1) T his d evice may not cau se har mful in terference, a nd (2) this d evice must acc ept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions , may cause harmful interfere nce to radio communication s. However, there is no guarantee that i nt er f erence will not occur i n a pa rti cul ar i n sta ll ati on . If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equ ipment off and on , the user is encouraged to try to correct th e interference b y one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equi p ment in to an ou tl et on a circu it dif f eren t f ro m that to wh ich th e receiv er is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.