Integrated Silicon Solution, Inc. — 1-800-379-4774
3
Rev. I
01/26/00
IS62LV256 ISSI
®
OPERATING RANGE
Range Ambient Temperature VCC
Commercial 0°C to +70°C 3.3V ± 5%
Industrial –40°C to +85°C 3.3V ± 5%
POWER SUPPLY CHARACTERISTICS
(1)
(Over Operating Range)
-45 ns -70 ns
Symbol Parameter Test Conditions Min. Max. Min. Max. Unit
ICC1 Vcc Operating VCC = Max., CE = VIL Com. — 20 — 20 mA
Supply Current IOUT = 0 mA, f = 0 Ind. — 30 — 30
ICC2 Vcc Dynamic Operating VCC = Max., CE = VIL Com. — 35 — 30 mA
Supply Current IOUT = 0 mA, f = fMAX Ind. — 45 — 40
ISB1 TTL Standby Current VCC = Max., Com. — 2 — 2mA
(TTL Inputs) VIN = VIH or VIL Ind. — 5 — 5
CE ≥ VIH, f = 0
ISB2 CMOS Standby VCC = Max., Com. — 90 — 90 µA
Current (CMOS Inputs) CE ≥ VCC – 0.2V, Ind. — 200 — 200
VIN ≥ VCC – 0.2V, or
VIN ≤ 0.2V, f = 0
Notes:
1. At f = f
MAX, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.
DC ELECTRICAL CHARACTERISTICS (Over Operating Range)
Symbol Parameter Test Conditions Min. Max. Unit
VOH Output HIGH Voltage VCC = Min., IOH = –1.0 mA 2.4 — V
VOL Output LOW Voltage VCC = Min., IOL = 2.1 mA — 0.4 V
VIH Input HIGH Voltage 2.2 VCC + 0.3 V
VIL Input LOW Voltage
(1)
–0.3 0.8 V
I
LI Input Leakage GND ≤ VIN ≤ VCC Com. –22µA
Ind. –55
ILO Output Leakage GND ≤ VOUT ≤ VCC, Outputs Disabled Com. –22µA
Ind. –55
Notes:
1. VIL = –3.0V for pulse width less than 10 ns.