Isotherm CR100, TB50, TB26, TB42, TB32 Installation And Operating Instructions Manual

...
Marine Refrigerators and Boxes
Installation and operating instructions
General
Specially designed to operate in tough marine environments, Isotherm fridges are outstanding in both performance and reliability. Fitted with a fully hermetic, leak-free compressor, they offer the lowest possible power consumption and noice level. All models are extremely simple to install. They can withstand an angle of heel up to 30°, for a short time even more. To ensure that your Isotherm fridge operates as efciently as possible, please follow these general guidelines:
• Unnecessary opening of the fridge door will increase power consumption.
• Good ventilation of the compressor and condenser unit will reduce power consumption.
• The electrical system should be in good condition. Inspect batteries and charging levels regularly. Always use a separate starter battery for the engine. Follow carefully the guidelines regarding electrical cable areas and fuse placements.
• Keep the inside of the fridge clean and dry. Remove any water that may collect on the shelf under the freezer compartment.
• Keep the door/lid slightly open to air the fridge when leaving the boat for any length of time. (Fig. 1 and 2)
Operation
Refrigerators and boxes with standard thermostat. See separate instructions for ASU versions.
Temperature setting
The fridges/boxes are tted with a manually operated, innitely-variable thermostat. This is turned clockwise to reduce temperature and anti­clockwise to both increase temperature and activate the on-off switch at the end position. A certain spring resistance is recognized at the off position. In most refrigerators, the thermostat knob is placed inside the refrigerator. The CR100 has the thermostat knob placed outside above the door. The build-in boxes and TB50 have the thermostat knob placed inside the refrigeration compartment. The TB26 and 42 boxes have the thermostat regulation placed outside and also have separate on-off switches. The TB32 has an electronic thermostat, see separate instructions.
Defrosting
Defrosting shall be made when the frost layer is more than 4 mm thick. Set the thermostat in OFF position. Store the foodstuff and the liqued as cold as possible during the defrosting process. Do not use sharp metal tools to remove frost or ice. Do not re-start until the fridge/box is completely defrosted, cleaned and dried. Empty also the drip tray below the freezer compartment.
Maintenance
The Isotherm refrigeration systems have a fully hermetic closed cooling system and do not require any maintenance or relling of refrigerant. The compressor is of domestic type and has a very high efency and an outstanding life-time. The fridge/box shall be left in the boat during the winter. (If the temperature is below freezing point, the compressor may not start). The maintenance is reduced to periodically, not less than a year, cleaning of the condenser from dust. Use a soft brush and no sharp tools. Keep the fridge/box inside clean. Use lukewarm water and a mild detergent for cleaning the inside. Put the door/lid, during not in operation periods, in its slightly open ventilation position. Release the catch on the door for this purpose with a coin or a small screwdriver. Take out the bulb from the internal light to avoid power consumption or switch off a main switch if there is one installed connected to the fridge power supply. (Fig. 1 and 2)
Battery voltage sensor
To protect the batteries from becoming completely discharged, a battery voltage sensor switches off the compressor automatically at the
following levels:
System voltage Cut-out Cut-in
12 9.6 10.9
24 21.3 22.7
Safety instructions
When connected to shore power, ensure that the power supply is equipped with an earth safety automatic switch. Danger! Never tough bare electrical wiring connected to the mains supply.
Danger!
Never connect battery charger direct to the refrigeration system. Battery charger must be connected to the battery. In addition to acid, a newly-charged battery contains explosive gas.
Danger!
Never cover the ventilation openings for the compressor unit. Refrigerant may never be let out in the air.
Installation instructions
Many boats have a space which is intended for a fridge. The Isotherm Cruise fridge has been designed to suit the general dimensions normally used for this purpose. The compressor should normally stand upright in the boat, but will operate at an angle of heel up to 30° and for short periods even more. The compressor on CR42 and 50 as well as on the BI40 is attached by its rear side. It can be removed so that it can be mounted by the side, from above or from below and is supplied with 1.5 m exible piping. The pipe must be carefully bended to avoid breaks or other damages. Installation can be made even simpler by using the mounting rails, that are available as accessories. The CR49, 65 and 195 have three side mounting frame mounted as standard which simplify the fastening of the dge. It should always stand on its feet and fastened from the front in the mounting frame. Three side mounting frames are also available as an option for other models. Build in boxes has to be well fastened and should be supported underneath. The compressor on BI41, 75 and 92 is attached by its bottom. It can be removed so that it can be mounted by the side or elsewere and is supplied with exible piping. The pipe must be carefully bended to avoid breaks or other damages. The fridge doors are hinged on the right hand side as standard. They can be re-hinged to the other side by taking off the door, moving the upper door hinge pin to the other side and also changing side of the lower door hinge pin ttings. The door locking is re-positoned to the other side of the door upper frame. It is fastened with three screws. See g. 3 & 4.
Ventilation
It is very important that the compressor/condenser unit is well ventilated and that cold air can enter at the bottom, pass behind the fridge and warm air can leave at the top in the area where it is mounted. The natural ow of air from below and upwards behind the fridge can be increased by arranging ventilation openings at the rear.