1 Introduction
1.1 General
1.2 Safety and precautions
1.3 Environmental markings
2 Installation instructions
2.1 Ventilation
2.2 Electrical connections
2.3 Wire dimensions
2.4 Door panel
3 Operation
3.1 Temperature setting
3.2 Defrosting
4 Maintenance
4.1 Battery voltage sensor
5 Technical data
6 Trouble shooting
7 Installation dimension drawings
1 Introduction
1.1 General
Isotherm refrigerators are specially designed to operate in tough marine environments. They are fi tted with a fully hermetic, leak-free compressor, they offer the lowest possible power consumption and noise level. All models are simple to install. They can withstand an angle of heel up to 30°, for a short time. To ensure that your Isotherm fridge operates as effi ciently as possible, please follow these general guidelines:
• Unnecessary opening of the fridge door will increase power consumption.
• Good ventilation of the compressor and condenser unit will reduce power consumption.
• The electrical system should be in good condition. Inspect batteries and charging levels regularly. Always use a separate starter battery for the engine. Follow carefully the guidelines regarding electrical able areas and fuse placements.
• Keep the inside of the fridge and freezer clean and dry. Remove any water from condensation that may have collected in the plastic baskets.
• Keep the door slightly open to air the refrigerator and freezer when leaving the boat for any length of time. (Fig. 1 and 2)
1.2 Safety and precautions
For your own and others safety, read this fi rst.
I.3 Environmental markings
The symbol on the product, or on the documents accompanying the product, indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for recycling of electrical and electronic equipment. Disposal must be carried out in accordance with local environmental regulations for waste disposal. For more detailed information about treatment, recovery and recycling of this product, please contact your local city offi ce, your household waste disposal service or the shop where you purchased the product.
Danger! Only connect the device to a 110 - 230 Volt power outlet installed according to regulations, being accordingly fused. When connected to mains power, ensure that the power supply is equipped with an earth safety automatic switch, a ”ground fault circuit interrupter”. Danger! Never touch bare electrical wiring connected to the AC power supply. Do not use the device if the connector cables show visible damage. Never connect battery charger direct to the refrigeration system. A battery charger must be connected to the battery, never direct to the refrigeration system. Danger! In addition to acid, a newly-charged battery contains explosive gas. Never cover the ventilation openings for the compressor unit. Refrigerant may never be let out in the air.
2 Installation instructions
Many boats have a space which is intended for a fridge. The Isotherm Cruise fridge has been designed to suit the general dimensions normally used for this purpose. The compressor should normally stand upright in the boat, but will operate at an angle of heel up to 30° and for short periods even more. The compressor on CR200 is attached by its rear side. The refrigerator/freezer unit has a three side mounting fl ange to fasten the unit in place. It must also be standing on its feet. See installation dimensions on fi g. 10. Avoid mounting close to a heat source, like gas ovens and heaters. Also avoid a position allowing direct sunshine on the refrigeration/freezer unit. The mounting position should be dry and protected from splashing water.
2.1 Ventilation
It is very important that the compressor/condenser unit is well ventilated and that cold air can enter at the bottom, pass behind the fridge and warm air can leave at the top in the area where it is mounted. The natural fl ow of air from below and upwards behind the fridge can be increased by arranging ventilation openings at the rear.
Make sure there is a free area of 23 - 28 sq.in. below and behind the refrigerator/freezer to allow ventilation air to pass behind from below. See fi g 5.
2.2 Electrical connections/wiring for power supply
CR200 is available in two versions, one is equipped with a Danfoss 12-24 VDC electronic unit and the other is equipped with a AC-DC electronic unit. It is important that following points are considered:
DC (12 or 24 volt)
The electronic unit must always be connected direct to the battery poles. Connect the positive/plus to + and the negative/ minus to - on the battery. Without proper positive/negative connections, the electronic unit will not work - it is protected against reverse battery connection. For protection of the installation, a fuse must be mounted in the positive cable as close to the battery as possible. A 15A fuse for a 12V power supply and a 7.5A fuse for a 24 volt circuit are recommended. If a breaker box connection is used, it should be rated to a minimum of 20A. Avoid extra junctions in the power supply system to prevent voltage drop from affecting the battery protection setting. The light is connected to battery power on the electronic unit and the bulb must be selected 12 or 24 volt. Both types are included in the delivery. See wiring diagram fi g. 8
AC (100-240 volt)
The live and neutral wires must be connected to the terminals marked L and N on the electronic unit. Nominal voltages from 100 to 240 VAC 50/60 Hz. Upper safety cut out limit is 270 VAC and lower limit is 80 VAC.Earth connection is to be placed on the compressor foot near the electronic unit. There is a hole drilled in the foot for this purpose, use a 5/32” screw and nut and a ring cable shoe on the wire. Connection of mains power plug must fulfi l valid electrical safety regulations and properly fused with 4A. Wire gauge, AWG18.