![](/html/0d/0d02/0d02056e40e9a329f1b79855eb479ec4e0ad578b5fe86ae5a3c8117027a051b8/bg1.png)
IsoLux llc, 1045 Collier Center Way, Naples, Florida USA 34110 phone: 239 514 7475 fax: 239 514 7476
email: info@isoluxllc.com web: www.isoluxllc.com
2.0 Operating Instructions
2.1 Charging the Battery
1. Plug the charger’s male connector into the
receptacle on the Battery Pack.
2. Plug the AC connection into a 100-240 VAC
source.
3. The charger indicator light will illuminate red
while charging and turn green when charging is
complete (approximately 3.6 hours).
4. An 85% partial charge may be performed in 2
hours.
5. Disconnect the charger from the AC source and
unplug the charger from the control unit.
2.2 Illuminator and Headband Operation
1. Plug the Cable Assembly into the illuminator
unit receptacle. There are red orientation dots
that must be aligned.
2. The cable should be routed and snapped into
place through a set of two cable clips. For dual
ratchet headsets one is located on the top on
the crown and one on the rear of the headband.
The user has the choice of using the set on the
left or the right.
3. For softband/Velcro headsets, the cable should
be routed through two clips along the
circumference.
4. The illumination spot size may be adjusted by
turning the grooved dial on the headlight.
5. The linkage assembly on the headband allows
for personal positioning control. The joystick is
used to further adjust the position of the light
beam.
2.3 Control Unit / Battery Pack Operation
1. Assure the Cable Assembly is plugged into the
illuminator unit receptacle. There are red
orientation dots that must be aligned.
2. Plug the other end of the Cable Assembly into
the Control Unit/ Battery Pack receptacle, once
again aligning the red dots.
3. Clip the control unit where desired or place in a
pocket.
4. Turn the ON/OFF and intensity control knob
clockwise to turn unit On (switch will close).
This knob also controls the intensity.
5. To turn unit Off, turn control knob counter-
clockwise until switch opens.
6. When battery has discharged to a level too low
to maintain operation, the Illuminator will dim
IsoLED Plus
HEADLIGHT
User’s Guide
1.0 Purpose and Features of the product
1.1 Purpose
The headlight is used for examination, diagnostics
and surgical operations for multifarious uses
including microsurgery.
1.2 Features
• 50,000 hours of LED life provides for a
maintenance free device with an end life of
approximately 20 years.
• The unit has infinite mobility, not confined by
access to power sockets, and its charge will last
more than 3 1/2 hours at full intensity.
• Its light beam is extremely homogeneous and
free of imperfections.
• Its high CRI rating of 96 is very desirable in
color-critical applications such as neonatal care,
medicine and surgery, as it shows the true
colors of tissues and skin, thereby reducing the
time to diagnosis and surgery.
• The light-weight battery packs have a retention
clip to be used on the user’s belt or pocket.
• The wall mounted Battery Charger comes with a
Charge Monitor that alerts the operator when
the Battery is fully charged.
• The unit comes with two (2) Battery Packs,
allowing for “Hot Swap” and the extension of its
operating time to > 7 hours.
![](/html/0d/0d02/0d02056e40e9a329f1b79855eb479ec4e0ad578b5fe86ae5a3c8117027a051b8/bg2.png)
IsoLux llc, 1045 Collier Center Way, Naples, Florida USA 34110 phone: 239 514 7475 fax: 239 514 7476
email: info@isoluxllc.com web: www.isoluxllc.com
or flicker and the green LED on the control
panel will turn off.
7. The unit’s operational time could be extended
from 3½ hours at full intensity to greater than 7
hours by using the illuminator at half intensity.
3.0 SPECIFICATIONS
4.0 Battery use and care
The capacity of Li-ion rechargeable batteries will be
changed by its’ environmental temperature. The
appropriate temperature is (10 ℃~40 ℃) range. Do not
expose the battery to extreme temperatures, if the
battery is used in high or low temperatures, the battery
capacity will be reduced.
Dispose of worn battery safely.
5.0 Care and Maintenance
5.1 Headlight, Headgear and Cable
Exterior surfaces of headlight, headgear and cable
can be wiped clean with 10% bleach, 70% isopropyl
alcohol or Mild soap.
Headbands and headlight modules cannot be
immersed into disinfecting liquids or sterilizers.
Keep ends of cable clean by wiping with a damp cloth.
Allow to dry before use.
Clean the optics only with lens tissue available at any
camera store. Follow the instructions on the
package.
To insure long life for the headgear, cable and power
source, store them in a cool dry environment.
5.2 Joystick
Joystick can be sterilized after unscrewing from
headlight.
DO NOT AUTOCLAVE ANY OTHER PARTS OF
THE HEADLIGHT SYSTEM !
6.0 Warnings and Cautions
6.1 Warnings
Users of this headlight should be trained in the
appropriate surgical procedures.
They should read and understand the owner’s manuals
for this Headlight and all equipment used in conjunction
with it.
Warning: This product must not be used in the
presence of flammable gases.
Warning: This product should not be immersed in
fluids.
Warning: Do not shine the light directly into the
patient’s eyes.
9.0 List of Spare Components
2 1 Headlight Illuminator
3 1 Headlight Cable Ass’y
4 1 Sweatbands (pack of 4 sets)
7 1 Replacement Head Gear
Color Rendition
Index (CRI)
10 to 100 mm @ 400 mm
working distance
>3.5 hours typical at
maximum intensity
2 hours, for 3 hours of
maximum intensity
Universal: 100 to 264 VAC,
50 to 60 Hz.,8.4 VDC @ 1.3 A
Size (control
unit/battery pack)