ISOCOM MOC3012, MOC3011, MOC3010X, MOC3009, MOC3009X Datasheet

...
8/8/01
MOC3009X, MOC3010X, MOC3011X, MOC3012X MOC3009, MOC3010, MOC3011, MOC3012
OPTICALLY COUPLED BILATERAL SWITCH NON-ZERO CROSSING
TRIAC
l UL recognised, File No. E91231
'X' SPECIFICATION APPROVALS
ll VDE 0884 in 2 available lead forms : -
- STD
- G form
DESCRIPTION
The MOC3009,301_ series are optically
coupled isolators consisting of a Gallium Arsenide infrared emitting diode coupled with a light activated silicon bilateral switch perform­ing the functions of a triac mounted in a standard 6 pin dual-in-line package.
FEATURE
l Options :-
10mm lead spread - add G after part no. Surface mount - add SM after part no. Tape&reel - add SMT&R after part no.
l High Isolation Voltage (5.3kV l 250V Peak Blocking Voltage l All electrical parameters 100% tested l Custom electrical selections available
RMS
,7.5kV
PK
APPLICATIONS
l CRTs l Power Triac Driver l Motors l Consumer appliances l Printers
OPTION SM
SURFACE MOUNT
OPTION G
7.62
Dimensions in
1 2 5
3
7.62
0.5
0.26
1.2
3.0
0.5
7.62
6.62
2.54
7.0
6.0
4.0
3.0
3.35
ABSOLUTE MAXIMUM RATINGS (25 °C unless otherwise noted)
Storage Temperature -400C - +1500C Operating Temperature -400C - +1000C Lead Soldering Temperature 2600C (1.6mm from case for 10 seconds) Input-to-output Isolation Voltage (Pk) 7500 Vac (60 Hz , 1sec. duration)
)
INPUT DIODE
Forward Current 50mA Reverse Voltage 6V Power Dissipation 70mW (derate linearly 0.93mW/0C above 250C)
OUTPUT PHOTO TRIAC
Off-State Output Terminal Voltage 250V RMS Forward Current 100mA Forward Current (Peak) 1A Power Dissipation 300mW (derate linearly 4.0mW/0C above 250C)
6
4
13° Max
0.6
0.1
10.46
9.86
1.25
0.75
0.26
10.16
ISOCOM COMPONENTS LTD
Unit 25B, Park View Road West,
Park View Industrial Estate, Brenda Road
Hartlepool, TS25 1YD England Tel: (01429)863609
Fax : (01429) 863581 e-mail sales@isocom.co.uk
http://www.isocom.com
POWER DISSIPATION
Total Power Dissipation 330mW (derate linearly 4.4mW/0C above 250C)
ISOCOM INC
1024 S. Greenville Ave, Suite 240,
Allen, TX 75002 USA
Tel: (214) 495-0755 Fax: (214) 495-0901
e-mail info@isocom.com
http://www.isocom.com
DB90040mAAS/A2
8/8/01
ELECTRICAL CHARACTERISTICS ( TA = 25°C Unless otherwise noted )
PARAMETER MIN TYP MAX UNITS TEST CONDITION
Input Forward Voltage (VF) 1.2 1.5 V IF = 10mA
Reverse Current (IR) 100 µA VR = 6V
Output Peak Off-state Current ( I
Peak Blocking Voltage ( V On-state Voltage ( V
Critical rate of rise of off-state
) 100 nA V
DRM
) 250 V I
DRM
) 1.5 3.0 V ITM = 100mA ( peak )
TM
Voltage ( dv/dt ) ( note 1 ) 10 V/µs Critical rate of rise of commutating Voltage ( dv/dt ) ( note 1 ) 0.1 0.2 V/µs I load = 15mA,
Coupled Input Current to Trigger ( IFT )(note 2 )
MOC3009 30 mA VD = 3V ( note 2 ) MOC3010 15 mA
MOC3011 10 mA MOC3012 5 mA
Holding Current , either direction ( IH ) 100 µA
Input to Output Isolation Voltage V
5300 V
ISO
7500 V
RMS PK
Note 1. Test voltage must be applied within dv/dt rating. Note 2. Guaranteed to trigger at an IF value less than or equal to max. I
between Rated I
Note 3. Measured with input leads shorted together and output leads shorted together.
and absolute max. I
FT
FT
.
, recommended IF lies
FT
= 250V (note 1 )
DRM
= 100nA
DRM
VIN = 30V ( fig 1. )
See note 3 See note 3
COMMUTATING dv/dt
+5v V
CC
STATIC dv/dt
0v
FIGURE 1
V
CC
+
-
R
IN
120
1
2
3
6
V
IN
5
R
4
L
~
2k
DB90040m-AAS/A2