ISOCOM IS221, IS220, IS223, IS222 Datasheet

IS220, IS221, IS222, IS223
OPTICALL Y COUPLED BILATERAL SWITCH LIGHT ACTIVA TED ZERO VOLTAGE CROSSING TRIAC
APPROVALS
l UL recognised, File No. E91231
DESCRIPTION
The IS22_ Series are optically coupled
isolators consisting of a Gallium Arsenide infrared emitting diode coupled with a mono­lithic silicon detector performing the functions of a zero crossing bilateral triac mounted in a standard 6 pin dual-in-line package.
FEATURES
l Options :-
10mm lead spread - add G after part no. Surface mount - add SM after part no. Tape&reel - add SMT&R after part no.
l High Isolation Voltage (5.3kV l Zero Voltage Crossing l 200V Peak Blocking V oltage l All electrical parameters 100% tested l Custom electrical selections available
RMS
,7.5kV
PK
Dimensions in mm
1
25
34
0.5
1.2
3.0
0.5
7.62
6.62
2.54
7.0
6.0
4.0
3.0
3.35
ABSOLUTE MAXIMUM RATINGS (25 °C unless otherwise noted)
Storage Temperature -400C - +1500C
)
Operating Temperature -400C - +1000C Lead Soldering Temperature 2600C (1.6mm from case for 10 seconds) Input-to-output Isolation Voltage (Pk) 7500 Vac (60 Hz , 1sec. duration)
6
7.62
13° Max
0.26
APPLICATIONS
l CRTs l Power Triac Driver l Motors l Consumer appliances l Printers
OPTION SM
SURFACE MOUNT
1.2
0.6
10.2
9.5
1.4
0.9
OPTION G
7.62
0.26
10.16
ISOCOM COMPONENTS LTD
Unit 25B, Park View Road West,
Park View Industrial Estate, Brenda Road
Hartlepool, Cleveland, TS25 1YD
Tel: (01429) 863609 Fax :(01429) 863581
INPUT DIODE
Forward Current 50mA Reverse Voltage 6V Power Dissipation 120mW (derate linearly 1.41mW/0C above 250C)
OUTPUT PHOTO TRIAC
Off-State Output T erminal V oltage 200V RMS Forward Current 100mA Forward Current (Peak) 1.2A Power Dissipation 150mW (derate linearly 1.76mW/0C above 250C)
POWER DISSIPATION
Total Power Dissipation 250mW (derate linearly 2.94mW/0C above 250C)
ISOCOM INC
720 E., Park Boulevard, Suite 104,
Plano, TX 75074 USA
Fax: (972) 422-4549
28/7/98
DB92609-AAS/A2
ELECTRICAL CHARACTERISTICS ( TA = 25°C Unless otherwise noted )
PARAMETER MIN TYP MAX UNITS TEST CONDITION
Input Forward Voltage (VF) 1.2 1.5 V IF = 30mA
Reverse Current (IR) 100 µAV
= 6V
R
Output Peak Off-state Current ( I
Peak Blocking V oltage ( V On-state V oltage ( V
TM
) 300 nA V
DRM
) 200 V I
DRM
= 200V (note 1 )
DRM
= 300nA
DRM
) 1.8 3.0 V ITM = 100mA ( peak )
Critical rate of rise of off-state Voltage ( dv/dt ) 100 V/µs
Coupled Input Current to Trigger ( IFT )(note 2 )
IS220 30 mA VTM = 3V ( note 2 ) IS221 15 mA IS222 10 mA IS223 7 mA
Holding Current , either direction ( IH ) 100 µA Input to Output Isolation Voltage V
Zero Inhibit V oltage ( VIH )35VI
Crossing MT1-MT2 V oltage
5300 V
ISO
7500 V
RMS PK
= Rated I
F
See note 3 See note 3
FT
Charact- above which device
-eristic will not trigger Leakage in Inhibited State ( IS ) 500 µAI
= Rated I
F
V
= 200V off-state
DRM
FT
Note 1. Test voltage must be applied within dv/dt rating. Note 2. Guaranteed to trigger at an IF value less than or equal to max. I
between Rated I
Note 3. Measured with input leads shorted together and output leads shorted together.
and absolute max. I
FT
FT
.
, recommended IF lies
FT
28/7/98