ISIC DuraPanel Series, DuraPanel 7"", DuraPanel 12 User Manual

User Manual
DuraPanel Series
DuraPanel 7”
DuraPanel 12”
Disclaimer
ISIC A/S makes no representation or warranties with respect to the contents or use of this manual, and specifically disclaims any express or implied warranties of merchantab ility or fitness for any particular purpose. Further, ISIC A/S reserves the right to revise this publication and to make changes to its content at any time, without obligat ion to notify any person or entity of such revisions or changes. Image sticking : If the monitor is operated with static images (logo’s etc) it will inevitably lead to images sticking on the display (like on old CRT’s). This is not a permanently situation and can be removed by operating the monitor with a completely black scre en.
FCC Warning
Computing devices and peripherals generate and radiate radio frequency energy, and if not installed and used in accordance with the instructions advised by ISIC A/S, it may cause interference to radio communication.
The DuraPanel series, ma n u fa ct u red by ISIC A/S, is designed to comply with the emerging generic EEC standards, that cover applications in marit ime environment.
Classification
The monitor is classified as “protected from the weather” according to IEC 60945 ed.4 (former class b).
Approvals
Approval according to IACS E10 ed. 6 and IEC 60945 ed. 4, Maritime navigation and radio communication equipment and systems – General requirements.
ISIC A/S is complying with the WEEE directive within the European Union, stating that electronic and electric products must be collected separately. Products are marked according to the directive.
Copyright 2015 ISIC A/S ISIC PN: 07353-000 rev. B
ISIC A/S Edwin Rahrsvej 54 DK-8220 Brabrand Denmark
Phone: +45 70 20 70 77 Fax: +45 70 20 79 76 Web: http://www.isic-systems.com
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 2
Table of Contents
1 FEATURES ............................................................................................................. 4
2 GENERAL CONSID ERATIONS ON INS TALLATION AND OPERATION ....................... 4
3 DURAPANEL CONNECTIONS .................................................................................. 5
4 CONNECTOR PIN-OUT ........................................................................................... 6
5 TECHNICAL SPECIFICAT ION DURAPANEL 7 .......................................................... 8
6 TECHNICAL SPECIFICAT ION DURAPANEL 12 ........................................................ 9
7 MECHANICAL OUTLINE DURAPANEL 7 – DROP IN ............................................... 10
8 MECHANICAL OUTLINE DURAPANEL 7 – FLUSH MOUNT ...................................... 11
9 MECHANICAL OUTLINE DURAPANEL 7 – RETROFIT ............................................. 12
10 MECHANICAL OUTLINE DURAPANEL 7 – SIMULATION ........................................ 13
11 MECHANICAL OUTLINE DURAPANEL 7 – OPTIONAL FAN ..................................... 14
12 MECHANICAL OUTLINE DURAPANEL 12 INCH - FLUSH ........................................ 15
13 MECHANICAL OUTLINE DURAPANEL 12 INCH - RETROFIT .................................. 16
14 MECHANICAL OUTLINE DURAPANEL 12 INCH – DROP IN .................................... 17
15 DURA COMMUNICATION PROTOCOL ................................................................... 18
16 BACKLIGHT, COLOR … ETC SETTINGS ................................................................. 22
17 COMPASS SAFE DISTANCE .................................................................................. 23
18 POWER CONSUMPTION ....................................................................................... 23
19 IN RUSH CURRENT .............................................................................................. 23
20 TROUBLESHOOTING ............................................................................................ 23
21 SERVICING THE UNI T ......................................................................................... 23
22 ISIC INFO / SUPPORT ......................................................................................... 24
23 REVISION HISTORY ............................................................................................ 25
24 APPENDIX A: PIXEL POLICY ................................................................................ 26
25 APPENDIX B: CERTIFICATE OF CONFORMITY ...................................................... 29
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 3
1 Features
Congratulations on your purchase of a DuraPanel. This short form manual is designed to get you started working with your new DuraPanel.
The DuraPanel series of Panel Computers are all designed for the demanding operating conditions at sea.
The DuraPanel series are tested for full compliance to marine-standards IACS E10 and IEC
60945. The DuraPanel comes with excellent brightness and contrast levels that, together with wide
viewing angles, ensure a good readability thus making it very eye-friendly. For the best picture quality, always use a double shielded DVI or VGA cable with ferrites on external monitor.
2 General considerations on Installation and
Operation
The DuraPanel is designed to work at conditions according to IEC 60945. However, keeping the temperature and vibration level at a minimum will extend the life time of the pro d uct. ISIC recommend operating this product at normal room temper ature (20-25 °C), with the lowest level of vibration and humidity.
Installation of the DuraPanel
In order to obtain the best possible operating conditions, please note the following precautions.
- Room for cooling. When designing the cabinet/console for the DuraPanel, please ensure that air can flow freely around the cabinet, in order to avoid any unnecessary rise in temperature. If it is not possible to have an adequate natural airflow, use a fan to force the airflow to be higher.
- Mounting positions The DuraPanel is designed for both horizontal and vertical installation.
- Sunlight Avoid direct sunlight to keep temperature low by that improve lifetime.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 4
3 DuraPanel connections
Below is a view of connections to the DuraPanel.
3.1 DuraPANEL7” connections
* Optional fa n output.
3.2 DuraPANEL12” connections
* FAN
PWR
4 x USB
4 x LAN
Serial
DVI-I
2 x PWR
DC
RESET
CHASSIS
*FAN
PWR
2 x USB
4 x LAN
Serial
2 x PWR
DC
RESET
DVI-I
CHASSIS
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 5
Pin1
4 Connector pin-out
Mating part: SUB-D 9 pole female, Norcomp 172-E09-20201 or equivalent.
4.1 DuraPANEL7” Serial
COM port used for external communication
COM2
COM port used for internal communication
COM1
Pin
RS-232
RS-422
RS-485
1
DCD
Tx-
D-
2
RxD
Tx+
D+
3
TxD
Rx+
4
DTR
Rx-
5
GND
6
DSR
7
RTS
8
CTS
9
RI
COM2 settings RS232/422/485 is set in BIOS
4.1 DuraPANEL12” Serial
COM port used for external communication
COM1
COM port used for internal communication
COM2
Pin
RS-232
RS-422
RS-485
1
DCD
Rx+
D+
2
RxD
Rx-
D-
3
TxD
Tx+
4
DTR
Tx-
5
GND
6
DSR
7
RTS
8
CTS
9
RI
COM1 needs to be specified when DuraPANEL12 is ordered. RS485 flow control is set in BIOS
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 6
Pin1
Pin1
4.2 Power input
The nominal input power voltage is 24V (18-36VDC). There are two independent galvanic isolated power inputs.
Mating part number: Weidmüller BLZP5.08HC/02/180F
Pin
Power in
1
0VDC
2
24VDC
4.3 Fan output
Mating part: JST XHP-2 (housi ng), SXH-001T-P0.6 (terminal)
Pin
FAN out
1
12VDC
2
0VDC
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 7
5 Technical specification DuraPanel 7
DuraPANEL - General
CPU:
Intel® Celeron® Processor J1900, 2.42 GHz (4 Cores / 4 Threads)
Chipset: Intel® processor Cor e, Gr a phics and Memory Controller in a single system-on-chip (S OC )
solution
Memory: 1 x SODIMM sockets with 1x 4GB DDR3L 1600MHz mounted
Up to 8GB DDR3L SODIMM
Hard Disk Drive: 80GB Intel® S3500 SSD SATA
Optional sizes 120GB / 160GB / 240GB / 300GB … 800GB SSD SATA III
Video:
External Video out:
Intel® HD Graphics controll er on-CPU
DirectX* 11 and OpenGL 4.0 compl i ant Dual Independent display capable
1 x DVI-I video outp ut c on ne ct or
Audio:
Built-in Buzzer (75-85 dB(A) / 1m)
Ethernet: 4 x 10/100/1000 Mbits/s Ethernet LAN on-board, (RJ45) with auto-negotiate
2 x Intel and 2 x Realtek
USB:
2 x USB 2.0 (max 0,5 Amp per USB, max 5 Watt total)
COM:
1 x RS232/422/485 (BIOS configurable)
OS:
Windows 7, Windows 8, Linux
DuraPANEL - Front
Display size:
7 inch LCD (TFT), IPS technology
Resolution:
800 x 480
Active area:
152 x 91 mm
View angle:
89° (T/B), 89° (L/R) (typi cal)
Luminance: 450 Cd/m2 (typical)
Optional Ambient light sensor
Contrast ratio:
Touch:
800:1 (typical)
10 finger PCAP touch (internal USB interface)
Front glass:
Anti Reflection
Protection: IP56 (from front, when mounted)
IP22 (from rear)
DuraPANEL - Power
Standard: 18-34VDC Galvanic isolated
Optional Dual input DC power, Galvanic isolated
Power Consumption:
P
typ
= 10 Watt, P
max
= 15 Watt
DuraPANEL - Environmental
Operating Temperature:
-15 to +55 °C
Storage Temperature:
-25 to +70 °C
Relative Humidity:
8 to 95 % (non-condensing)
DuraPANEL - Approvals
CE Mark:
EN61000-6-2
Marine:
IACS E10 Rev. 5 & IEC 60945 Ed. 4
Shock:
±5G, 10ms in accordance with IEC 60068-2-27
Certificates:
MR certificate
DuraPANEL - Dimensions
Size:
218 (W) x 147mm (H) x 59mm (Depth behi nd b ezel )
Weight: App. 2 kg.
Optional Bracket:
Desk/ceiling-and wall-bracket (VESA 75x75mm)
Optional Accessories: External fan for VESA mounting
2 page flyer rev. 11.02.2016. Technical specifications are subject to change without prior notice. For drawing
and full technical specifications please consult the users ma nual.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 8
6 Technical specification DuraPanel 12
DuraPANEL - General
CPU:
Intel® Celeron® Processor 2980U (2M Cache, 1.60 GHz) (2 Cores / 2 Threa ds )
Chipset: Intel® processor Cor e, Gr a phics and Memory Controller in a single system-on-chip (S OC )
solution
Memory: 2 x SODIMM sockets with 1x 4GB DDR3L 1600MHz mounted
Up to 16GB DDR3L SODIMM
Primary Disk Drive: 80GB Intel® S3500 SSD SATA
Optional sizes 120GB / 160GB / 240GB / 300GB … 800GB SSD SATA
Optional Secondary Disk Drive (Removable): 80GB Intel® S3500 SSD SATA (optional)
Optional sizes 120GB / 160GB / 240GB / 300GB … 800GB SSD SATA
Video:
External Video out:
Intel® HD Graphics controller on-CPU
DirectX* 11 and OpenGL 4.0 compl i ant Dual Independent display capable
1 x DVI-I video outp ut c on ne ct or
Audio:
Built-in Buzzer (75-85 dB(A) / 1m)
Ethernet: 4 x 10/100/1000 Mbits/s Ethernet LAN on-board, (RJ45) with auto-negotiate
1 x Intel® I218 and 3 x Intel® I210AT
USB:
COM:
OS:
4 x USB 3.0 (max 0,5 Amp per USB, max 5 Watt total) 1 x RS232/422/485 (configurable, choose when place order)
Windows 7, Windows 8, Linux
DuraPANEL - Front
Display size:
12,1 inch 16:10 LCD (TFT), MVA technology
Resolution:
1280 x 800
Active area:
261 x 163 mm
View angle:
88° (T/B), 88° (L/R) (typi cal)
Luminance: 400 Cd/m2 (typical)
Optional Ambient light sensor
Contrast ratio:
Touch:
1000:1 (typical)
10 finger PCAP touch (internal USB interface)
Front glass:
Anti Reflection
Protection: IP56 (from front, when mounted)
IP22 (from rear)
DuraPANEL - Power
Standard: 18-34VDC Galvanic isolated
Optional Dual input DC power, Galvanic isolated
Power Consumption:
P
typ
= 20 Watt, P
max
= 25 Watt
DuraPANEL - Environmental
Operating Temperature:
-15 to +55 °C
Storage Temperature:
-25 to +70 °C
Relative Humidity:
8 to 95 % (non-condensing)
DuraPANEL - Approvals
CE Mark:
EN61000-6-2
Marine:
IACS E10 Rev. 5 & IEC 60945 Ed. 4
Shock:
±5G, 10ms in accordance with IEC 60068-2-27
Certificates:
MR certificate
DuraPANEL - Dimensions
Size:
396 mm (W) x 256 mm (H) x 63.5 mm (Depth behind bezel) – Drop-in retrofit 13.3” version
Weight: App. 4 kg.
Optional Bracket:
Desk/ceiling-and wall-bracket (VESA 75x75mm)
2 page flyer rev. 24.06.2015. Technical specifications are subject to change without prior notice. For drawing
and full technical specifications please consult the users manual.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 9
7 Mechanical outline DuraPanel 7 – Drop in
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
A A
B B
C C
D D
E E
F F
G G
H H
218
147
4x R0,5
0
3,5
52,1 58,1
65,1
VESA 75
VESA 75
VESA 4x M4x0.7 x 6 deep
32
136
213
2,5
2,5
5,55,5
10
6
214
195
137
126
134,4
204
4x Ø6,3
62,6
Approved by
Projection method:
Drawing size:
Units: mm
Designed by
KSC
25-08-2015
Mechanical outline DuraPanel 7" Drop in
NJS 25-08-2015
General tolerances: `0,2 Hole position:
`
0,1
Angle, straightness and flatness: DS/ISO 2768-H
Scale:
Drawing no.
Replaces:
07376-001 A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077. Web: www.isic.dk
This docoment contains proprietary information and is not to be used or reproduced without the written permission of ISIC A/S
ECO
Material:
Surface: Sheet: 1 of 1
A1
1:1
Recommended panel cut out
134,4
204
4x M3 x max 3 deep
4x M3 x 12
2
n
6
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 10
8 Mechanical outline DuraPanel 7 – Flush mount
Approved by
Projection method:
Drawing size:
Units: mm
Designed by
KSC
25-08-2015
Mechanical outline DuraPanel 7" Flush
NJS 25-08-2015
General tolerances: `0,2 Hole position:
`
0,1
Angle, straightness and flatness: DS/ISO 2768-H
Scale:
Drawing no.
Replaces:
07376-004 A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077. Web: www.isic.dk
This docoment contains proprietary information and is not to be used or reproduced without the written permission of ISIC A/S
ECO
Material:
Surface: Sheet: 1 of 1
A1
1:1
VESA 4x M4x0.7 x 6 deep
57,6
0
5
56,6 63,6
4,5
228
157
97
6x n4,5 THRU
4x R0,5
233
162
147
218
4x R8
VESA 75
VESA 75
39,5
7,5
7,5
7,5
7,5
148
219
Recommended panel cut out
228
157
97
6x M4 or Ø4,5
4x R1
213
136
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
A A
B B
C C
D D
E E
F F
G G
H H
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 11
9 Mechanical outline DuraPanel 7 – Retrofit
0
7,1
54,5 61,5
237
154
19
4x R1
VESA 75
VESA 75
42
136
15,515,5
213
18,5
18,5
4x M5
250
167
154
237
143
215
4x Ø5,5
Recommended panel cut out
Approved by
Projection method:
Drawing size:
Units: mm
Designed by
KSC
25-08-2015
Mechanical outline DuraPanel 7" Retrofit
NJS 25-08-2015
General tolerances: `0,2 Hole position: `0,1 Angle, straightness and flatness: DS/ISO 2768-H
Scale:
Drawing no.
Replaces:
07376-002 A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077. Web: www.isic.dk
This docoment contains proprietary information and is not to be used or reproduced without the written permission of ISIC A/S
ECO
Material:
Surface: Sheet: 1 of 1
A1
1:1
VESA 4x M4x0.7 x 6 deep
55,5
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
A A
B B
C C
D D
E E
F F
G G
H H
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 12
10 Mechanical outline DuraPanel 7 – Simulation
140
266
4x M4 or Ø4,5
Approved by
Projection method:
Drawing size:
Units: mm
Designed by
KSC
25-08-2015
Mechanical outline DuraPanel 7" Simulator
NJS 25-08-2015
General tolerances: `0,2 Hole position: `0,1 Angle, straightness and flatness: DS/ISO 2768-H
Scale:
Drawing no.
Replaces:
07376-003 A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077. Web: www.isic.dk
This docoment contains proprietary information and is not to be used or reproduced without the written permission of ISIC A/S
ECO
Material:
Surface: Sheet: 1 of 1
A1
1:1
VESA 4x M4x0.7 x 6 deep
60,5
286
176
213
36,5
36,5
0
2,15
59,5 66,5
286
176
100
266
4x n4,5 -8 DEEP
w n
9 X 90°
136 20
20
VESA 75
VESA 75
46,5
R6
Recommended panel cut out
215
143
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
A A
B
B
C C
D
D
E
E
F
F
G G
H H
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 13
11 Mechanical outline DuraPanel 7 – Optional fan
Approved by
Projection method:
Drawing size:
Units: mm
Designed by
KSC
24-9-2015
Mechanical outline Optional fan for
DuraPanel 7"
NHL
24-9-2015
General tolerances: `0,2 Hole position: `0,1
Angle, straightness and flatness: DS/ISO 2768-H
Scale:
Drawing no.
Replaces:
07386-000
A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: + 45 70207077. Web: www.isic.dk
This docoment contains proprietary information and is not to be used or reproduced without the written permission of ISIC A/S
ECO
.
Material:
Surface: Sheet: 1 of 1
A2
1:1
76,2
72
17
60
85
60
85
12VDC Plup for fan.
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A A
B B
C C
D D
E E
F F
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 14
12 Mechanical outline DuraPanel 12 inch - Flush
218
314
Recommended panel cut out
323
227
130
8x M4 or Ø4,5
4x R1
Approved by
Projection method:
Drawing size:
Units: mm
Designed by
KSC 28-08-2015
Mechanical outline DuraPanel 12,1" Flush
NJS
28-08-2015
General tolerances: `0,2 Hole position: `0,1 Angle, straightness and flatness: DS/ISO 2768-H
Scale:
Drawing no.
Replaces:
07377-002
A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077. Web: www.isic.dk
This docoment contains proprietary information and is not to be used or reproduced without the written permission of ISIC A/S
Material:
Surface: Sheet: 1 of 1
A0
1:1
0
64,5 71,5
4,5
304,6
25
88,5
VESA 4x M4x0.7 x 6 deep
VESA 75
VESA 75
150
96
12,5
12,1
36
313
217
237
333
130
150
8x Ø4,5
R2,5
R13
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
A A
B B
C C
D D
E E
F F
G G
H H
I I
J J
K K
L L
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 15
13 Mechanical outline DuraPanel 12 inch - Retrofit
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
A A
B B
C C
D D
E E
F F
G G
H H
I I
J J
K K
L L
215
364
212
308
4x Ø5,5
Recommended panel cut out
Approved by
Projection method:
Drawing size:
Units: mm
Designed by
KSC 25-08-2015
Mechanical outline DuraPanel 12,1" Retrofit
NJS
25-08-2015
General tolerances: `0,2 Hole position:
`
0,1
Angle, straightness and flatness: DS/ISO 2768-H
Scale:
Drawing no.
Replaces:
07377-001
A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077. Web: www.isic.dk
This docoment contains proprietary information and is not to be used or reproduced without the written permission of ISIC A/S
Material:
Surface: Sheet: 1 of 1
A0
1:1
4x M5
18,5
0
7
62 69
304,6
44,4
46,5
396
256
4x R0,5
207
24,5
24,5
25
98
VESA 75
VESA 75
364
215
63
VESA 4x M4x0.7 x 6 deep
12,5
9,6
96
24,5
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 16
14 Mechanical outline DuraPanel 12 inch – Drop In
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
A A
B B
C C
D D
E E
F F
G G
H H
I I
J J
K K
L L
304
289
208
193
203
299
4x Ø7,3
Approved by
Projection method:
Drawing size:
Units: mm
Designed by
KSC 28-08-2015
Mechanical outline DuraPanel 12,1" Drop in
NJS
28-08-2015
General tolerances: `0,2 Hole position:
`
0,1
Angle, straightness and flatness: DS/ISO 2768-H
Scale:
Drawing no.
Replaces:
07377-004
A
Rev.
Subject:
ISIC A/S, Edwin Rahrs Vej 54, DK-8220 Brabrand. Tlf.: +45 70207077. Web: www.isic.dk
This docoment contains proprietary information and is not to be used or reproduced without the written permission of ISIC A/S
Material:
Surface: Sheet: 1 of 1
A0
1:1
Recommended panel cut out
303,3
207,3
VESA 75
VESA 75
29,9
78,5
313
217
4x R0,5
0
4
65 72
4,85
4,85
4,85
4,9
70
VESA 4x M4x0.7 x 6 deep
10
8
8
10
96
12,5
24,5
12,6
4x M4 x 12
203
299
n
7
2
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 17
15 Dura Communication protocol
15.1 Message Format
The interface board supports a data rate of 19200 bits per second. Data shall be transmitted with no p a r ity, one start bit, and one stop bit. The basic message format is shown below:
ATTN
ADDR
CMD LEN
IHCHK
DATA
IDCHK
The minimu m message len gth is 7 bytes .
15.1.1 Attention (ATTN)
This byte identifies the start of a message. The following three values are defined:
ATTN Description
0x07 Command 0x06 Acknowledge 0x15 Negative Acknowledge
A remote master initiates a command using the 0x07 attention code. The interface board will reply with an acknowledge (ACK) code if the command was received successfully, or a negative acknowledge (NACK) if the command contained errors. Note that the interface board will acknowledge messages, even if it fails to execute the actions contained within. NACKs are only issued when t he message format is corr upted, e. g. invalid checksums.
15.1.2 Address (ADDR)
This byte is used to identify and add ress individual interface boards. In a multi -slave configuration, the master can target each interface board individually, in which case the addressed interface board will reply with either an ACK or a NACK. The remote master can address all interface boards simultaneously using the broadcast address. In this case the interface boards will not reply.
ADDR Description
0x00:0xFE Individual address space
0xFF Broadcast address
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 18
15.2 Command (CMD)
The following commands are defined for the interface board:
CMD Description
MAN Manufacturer ID
BZZ Buzzer Control Command FAN Fan Control Command ETC Elapsed Time Co unter TMP Temperature Sensor
LIS Light Sensor
15.2.1 Data Length (LEN)
This byte contains the length of the DATA field. The minimum value is 0 bytes. No messages have been defined with a length of mor e than 35 byt es.
15.2.2 Inverse Header Checksum (IHCHK)
This is a simple 8 bit checksum. The checksum byte is initialized to 0. A bit-wise inversion of bytes 0 to 5 is performed. The 8 bit sum (without carry) of inverted bytes 0 to 5 and byte 6 shall be 0xFF. If a message fails the checksum, the interface board will reply with a NACK message with zero data. This requirement does not apply to broadcasted messages.
15.2.3 Data Sent (DS)
The DS field is only transmitted as a mirr or of the sent data.
15.2.4 Data Field (DATA)
The data field is only transmitted if LEN is greater than 0. The field carries additional data depending of the message command.
15.2.5 Inverse Data Checksum (IDCHK)
The inverse data checksum is only transmitted if LEN is greater than zero. The checksum is initialized to 0. A bit-wise inversion of DATA field(s) is performed. The 8 bit sum (without carry) of the inverted bytes and the IDCHK shall be 0xFF. The interface board will reply with a NACK to all messages with invalid chec ksums. This requirement does not ap ply to broadcasted messages.
15.2.6 No Operation (NOP)
This is empty data ‘0x00’ and only used as a filler between detection bytes for the reset command.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 19
15.3 Message Command
15.3.1 Manufacturer ID (MAN)
This command shall be sent to the interface board to request Manufacturer ID Code. No data shall be sent with the command The interface board will reply to this command with an ACK attention co de. The DATA field will be set to an ASCII string with the value “ISIC”.
Example: Ask for the Manufacturer ID:
ATTN
ADDR
CMD
LEN
IHCHK
0x07
0x00
0x4D
0x41
0x4E
0x00
0x1C
Reply from interface board (“ISIC”):
ATTN
ADDR
CMD
LEN
IHCHK
DATA
IDCHK
0x06
0x00
0x4D
0x41
0x4E
0x04
0x19
0x49
0x53
0x49
0x43
0xD7
15.3.2 Monitor Firmware Version (VER)
This command is sent to the monitor to request the Firmware Version of the embedded code. No data shall be sent with the command. The monitor will reply to this command with an ACK attention code. The DATA field will be set to an ASCII string with the ISIC P/N and revision. Maximum length is 20 characters.
Example: Ask for the Monitor Firmware Version:
ATTN
ADDR
CMD
LEN
IHCHK
0x07
0x00
0x56
0x45
0x52
0x00
0x0B
Reply from mo nitor (“07050-000-B”):
ATTN
ADDR
CMD
LEN
IHCHK
DATA
0x06
0x00
0x56
0x45
0x52
0x0B
0x01
0x30
0x37
0x30
0x35
0x30
0x2D
DATA (cont.)
IDCHK
0x30
0x30
0x30
0x2D
0x42
0xD7
15.3.3 Buzzer Control Command (BZZ)
This command will change the state of the buzzer on interface boards with a buzzer integrated. The value placed in the DATA field selects the state of the buzzer as listed below:
DATA State
0x00 Turn the buzzer off (DEFAULT)
0xFF Turn the buzzer on
If the checksum is valid and the command completes successfully, the interface board will reply with an ACK message with the current buzzer state in the DATA field. If the checksum was invalid, the interface board will reply with an ACK message.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 20
Example: Turn the buzzer on:
ATTN
ADDR
CMD
LEN
IHCHK
DATA
IDCHK
0x07
0x00
0x42
0x5A
0x5A
0x01
0x01
0xFF
0x00
Reply from Interface board:
ATTN
ADDR
CMD
LEN
IHCHK
DATA
IDCHK
0x06
0x00
0x42
0x5A
0x5A
0x01
0x02
0xFF
0x00
15.3.4 Fan Control Command (FAN)
This command will change the state o f the fan on mo nitors with a fan integra ted. The value placed in the DATA field selects the state of the fan as listed below:
DATA State
0x00 Turn the fan off
0x01
Switches the fan to temperature
controlled (DEFAULT)
0xFF Turn the fan on
If the checksum is valid and the command completes successfully, the monitor will reply with an ACK message with the current fan state in the DAT A field. If the checksum was invalid, the monito r will reply with a NACK message.
Example: Turn the fan on:
ATTN
ADDR
CMD
LEN
IHCHK
DATA
IDCHK
0x07
0x00
0x46
0x41
0x4E
0x01
0x22
0xFF
0x00
Reply from Monitor:
ATTN
ADDR
CMD
LEN
IHCHK
DATA
IDCHK
0x06
0x00
0x46
0x41
0x4E
0x01
0x23
0xFF
0x00
15.3.5 Temperature Sensor (TMP)
Query the interface board for the current temperature. The reply will contain a 1 byte mirror ‘DS’ and 3 byte ASCII string ranging from -55 to 125 °C.
Example: Query for current temperature:
ATTN
ADDR
CMD
LEN
IHCHK
DATA
IDCHK
0x07
0x00
0x54
0x4D
0x50
0x01
0x06
0x52
0xAD
Reply from interface board (“025” for 25 °C)
ATTN
ADDR
CMD
LEN
IHCHK
DS
DATA
IDCHK
0x06
0x00
0x54
0x4D
0x50
0x04
0x04
0x52
0x30
0x32
0x35
0x16
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 21
15.3.6 Light Sensor (LIS)
Query the interface board for the surrounding light. The reply will contain a 5 byte ASCII ranging from 00000 to
65535.
Example: Query the Light Sensor for the current value:
ATTN
ADDR
CMD
LEN
IHCHK
0x07
0x00
0x4C
0x49
0x53
0x00
0x10
Reply from interface board (“00100”):
ATTN
ADDR
CMD
LEN
IHCHK
DATA
IDCHK
0x06
0x00
0x4C
0x49
0x53
0x05
0x0C
0x30
0x30
0x31
0x30
0x30
0x0E
16 Backlight, color … etc settings
The monitor of DuraPANEL7 & 12 are detected as a Display Port monitor. DuraPANEL7 & 12 support DDC/CI commands for display settings like bri ghtness, contrast, color luminance, color temperature.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 22
17 Compass safe distance
Test object / condition
Minimum Compass safe
distance [cm]
(5.4°/H deviation or a
horizontal magnetic flux of
0.094µT)
Minimum Compass safe
distance [cm]
(18°/H deviation or a
horizontal magnetic flux of
0.313µT)
DuraPanel 7
45 cm
30 cm
DuraPanel 12
75 cm
55 cm
18 Power Consumption
Test object / condition
Ptyp [W]
Pmax [W]
DuraPanel 7
10W
15W
DuraPanel 12
20W
25W
19 In rush current
Test object / condition
[A] @24VDC
DuraPanel 7
~ 85
DuraPanel 12
~ 85
20 Troubleshooting
Problem
Cause
Solutions
No picture on display
No power connected
Apply power
Touch has an offset
No grounding of the chassis
Connect ground cable to chassis screw
No calibration of touch
Calibrate touch
21 Servicing the unit
In case that the unit still fails after following the troubleshooting send the unit to ISIC for repair via our RM A s e rvice on our web.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 23
22 ISIC info / Support
In case you have inquiries or problems with your DuraPanel, you have a number of possibilities to get support.
Company name:
ISIC A/S
Head office:
Edwin Rahrs Vej 54
DK-8220 Brabrand
Denmark
Shipping address:
Holmstrupgaardvej 5
DK-8220 Brabrand
Denmark
Telephone:
+45 70 20 70 77
Fax:
+45 70 20 79 76
Mail:
mail@isic-systems.com
www:
www.isic-systems.com
VAT number:
DK 16 70 45 39
Bank Name/Address:
Handelsbanken A/S
Havneholmen 29 DK-1561 København V
Denmark
Bank Code:
0892
SWIFT:
HANDDKKK
IBAN for DKK:
DK53 0892 0001 0159 69
IBAN for EUR:
DK48 0892 0003 0026 19
IBAN for USD:
DK26 0892 0003 0026 27 Contacts:
RFQ’s:
By fax to +45 70 20 79 76
By mail to sales@isic-systems.com
Orders:
By fax to +45 70 20 79 76
By mail to orders@isic-systems.com
Support:
Via homepage www.isic-systems.com under aftersales
By mail to service@isic-systems.com
During office-hours (Mo-Fr: CET 0800 - 1600) at +45 70 20 70 77
Service:
Before shipment for service Request Return Material Authorization number at homepage www.isic-systems.com under RMA
By mail to service@isic-systems.com
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 24
23 Revision history
Rev A
June 2015
First release
Rev B
February 2016
Chapter 1: No cable is supplied with the panel PC’s
Chapter 3: new DuraPANEL7” drawing in updated and RS232 changed to serial. Chapter 4: RS422/485 information added in, serial table updated with correct pin out. DuraPANEL12 swapped COM1 & COM2.
Chapter 15: added DDC/CI information.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 25
24 Appendix A: Pixel policy
ISO 9241-307:2008 guidelines for LCD pixel defects
Introduction
TFT displays consist of a set number of pixels. Each pixel consists of 3 sub-pixels also called dots (one red, one blue and one green) . Every sub-pixe l is addressed b y its own transistor. As a result, the manufacturing of glass substrate is very comple x. Due to the nature of this manufacturing process, occasional defects can occur. Pixel defects or failures cannot be fixed or repaired and may occur at any stage during the service life of the TFT display. To regulate the acceptability of defects and protect the end user, ISIC A/S complies with the ISO 9241-307:2008 standard. This standard recommends how many defects are considered acceptable in a display, before it should be replaced within the terms of the warranty.
Monitor classification
ISO 9241-307:2008
Allowed defects per type per million pixels
Defect classes
Pixel defects Cluster defect
Type 1 Type 2
Type 3 total
(2xN
3a
+ N3b)
Type 1 Type 2 Type 3
Class: 0 0 0 0 0 0 0 Class: I 1 1 5 0 0 0
Class: II 2 2 10 0 0 1
Class: III 5 15 100 0 0 5
ISIC TFT monitors comply with ISO 9241-307:2008 Class II. Special agreements about other classifications can be made between ISIC A/S and the customer.
Measurement method/mon itor ing cond ition s for pixel defects
In compliance with the ISO-9241-307:2008 standard, the following conditions are observed:
Final check for pixel fault undertake n right after burn-in, i.e. with pre-heating of the display.
Surrounding temperature 25ºC ± 5ºC
Relative air humidity 40–70%
Pixel definition
Every pixel consists of t hree sub-pixels/dots (red, blue, green). Every sub-pixel has its own transistor. The three sub-pixels/dots must be considered as one unit.
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 26
Pixel
Pixel defect type 1 Pixel constantly lit Pixel defect type 2 Pixel constantly dark
Pixel defect type 3a Pixel defect type 3b
Sub-pixel/dot
(red, blue, green) consta ntly lit Sub-pixel/dot (red, blue, green) constantly dark
Cluster
A cluster consists of 5 x 5 pixels.
Cluster pixel defect type 1 Cluster pixel defect type 2
Pixels in a cluster area constantly lit Pixels in a cluster area constantly dark
Cluster pixel defect type 3a Cluster pixel defect type 3b Sub-pixels/dots in a cluster area constantly lit Sub-pixel s/dots in a cluster area constantly dark
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 27
Pixel faults accepted by ISIC A/S
The maximum number of pixel faults that is considered acceptable at different screen resolutions is shown in the table below. Thi s i s the native resolution and not the resolution as adjusted by user.
Class II
Allowable number of pixel faults in monitor applications
Screen
type
Native
resolution
Number of
pixels
Pixel defect
type 1
Pixel defect
type 2
Pixel defect
Type 3 total
(2xN
3a
+ N3b)
Cluster
defect type
1 and 2
Cluster
defect type 3
WVGA
800x480
384,000 0 0
3
0
0
XGA 1024x768 768,432 1 1 7
0
0
WXGA 1280x800 1,024,000 2 2 10
0
1
SXGA 1280x1024 1,310,720 2 2 13
0
1
UXGA 1600x1200 1,920,000 3 3 19
0
1
FHD 1920x1080 2,073,600 4 4 20
0
2
WUXGA 1920x1200 2,304,000 4 4 23
0
2
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 28
25 Appendix B: Certificate of Conformity
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 29
Edwin Rahrs Vej 54
DK-8220 Brabrand
Denmark
Web: http://www.isic-systems.com
Email: service@isic-systems.com
User Reference Manual – DuraPanel series
PN: 07353-000 Rev B Page 30
Loading...