ISHTAA ITP Series User Manual

ITP- Series
Price Computing Scale
Scale Users Guide
ISHTAA SCALES INC., COIMBATORE, INDIA
www.ishtaascales.com
CONFIGURATION
CONFIG.
TO CHANGE THE CAPACITY, CHANGE THE DIGIT OF PERTICULAR
CAPACITY…
THEN SET 0 TO 30 KG (30.000) USING ACL & CL KEY.THEN PRESS SET KEY.IT WILL SHOW RESAL ON DISPLAY.
TO CHANGE THE RECAL USE ACL & CL KEY
THEN PRESS T/Z KEY .IT WILL SHOW AUTO-0.
TO CHANGE AUTO-0, YOU CAN PRESS UP TO 0 TO 9 USING KEY PAD.
PRESS SET KEY,IT WILL SHOW DP ON DISPLAY
TO CHANGE THE DP USE ACL & CL KEY FROM KEY PAD
PRESS SET KEY,IT WILL SHOW DG. OFF ON DISPLAY
TO CHANGE DG. OFF USE ACL & CL KEY FROM KEY PAD. (EITHER YES OR
NO).
PRESS SET KEY,IT WILL SHOW LST DG ON DISPLAY
TO CHANGE LST DIG PRESS ACL & CL KEY FROM KEY PAD (EITHER YES OR
NO).
PRESS SET KEY,IT WILL SHOW LETER ON DISPLAY
TO CHANGE LETER PRESS ACL & CL KEY FROM KEY PAD.
PRESS SET KEY.IT WILL SHOW LTER-U ON DISPLAY.
TO CHANGE LTER-U PRESS ACL & CL KEY FROM KEY PAD.
PRESS SET KEY,IT WILL SHOW LTER-DES ON DISPLAY & ASK FOR
PASSWARD.
TO SET THE PASSWARD USE KEY PAD TO ENTER 8756 AS DEFAULT
PASSWARD.
PRESS SET KEY,IT WILL SHOW DENSITY ON DIPLAY.
TO SET DENSITY,PRESS ACL & CL KEY FROM KEY PAD.THE DEFAULT
VALUE OF DENSITY IS 970.
PRESS SET KEY,IT WILL SHOW PIECE ON DISPLAY.
TO SET PIECE, PREE ACL & CL KEY FROM DISPLAY.
PRESS SET KEY.IT WILL SHOW L-LMIT(LOWER LIMIT) ON DISPLAY.
TO SET L-LMIT USE KEY PAD
PRESS SET KEY,IT WILL SHOW H-LMIT(HIGHER LIMIT) ON DISPLAY
TO SET H-LMIT USE KEY PAD.
PRESS SET KEY.
NOTE: AS YOU PRESS SET KEY, IT WILL AUTO SAVE YOUR ALL CONFIG SETTING.
FACTORY CALIBRATION
PRESS MODE & MT THEN SWITCH ON THE SCALE, THE DISPLAY WILL
SHOW PASS.
ENTER THE DEFAULT PASS WARD 8756 USING KEY PAD.
PRESS SET KEY, IT WILL SHOW SEG-1 ON DISPLAY.
TO CHANGE THE CAPACITY OF SEG-1,USE KEYPAD TO CHANGE THE
PERTICULAR DIGIT OF CAPACITY.THE DIGIT WILL START BLINKING AS YOU REACH ON PERTICULAR DIGIT.
THE PRESS SET KEY AFTER CHANGE THE SEG-1. IT WILL SHOW SEG-2 ON
DISPLAY.
TO CHANGE THE CAPACITY OF SEG-2,USE KEYPAD TO CHANGE THE
PERTICULAR DIGIT OF CAPACITY.THE DIGIT WILL START BLINKING AS YOU REACH ON PERTICULAR DIGIT.
THEN PRESS SET KEY,IT WILL SHOW LOAD ON YOUR DISPLAY.
FIRST PUT THE WEIGHT THAT YOU ENTER IN SEG-1 & PRESS SET.
THEN PUT THE WEIGHT THAT YOU ENTER IN SEG-2 & PRESS SET.
FIELD CALIBRATION
PRESS “LEFT ARROWKEY ”AND “UP ARROW KEY” & SWITCH ON THE
SCALE.THE DISPLAY WILL SHOW PASS.
ENTER THE DEFAULT PASS WARD 8756 USING KEY PAD.
PRESS SET KEY, IT WILL SHOW SEG-1 ON DISPLAY.
TO CHANGE THE CAPACITY OF SEG-1,USE KEYPAD TO CHANGE THE
PARTICULAR DIGIT OF CAPACITY.THE DIGIT WILL START BLINKING AS YOU REACH ON PERTICULAR DIGIT.
PRESS SET, THE DIPPLAY WILL SHOW LOAD.
PUT THE WEIGHT THAT YOU ENTER IN SEG-1 &PRESS SET KEY.
FOR MEMORY SETTING
PRESS * KEY ,IT WILL SHOW ‘0’ ON DISPLAY.
THEN PRESS M1,IT WILL SHOW ‘1’ ON DISPLAY.
PRESS SET KEY & SIMENTANIOUSLY PRESS * KEY.
IT WILL SHOW VALUE OF M1 ON DISPLAY. TO CHANGE THE VALUE OF M1,
PRESS CL KEY FROM KEYPAD & PRESS SET KEY
TO SET DIRECT VALUE
TO SET THE DIRECT VALUE,PRESS CL KEY & ENTER THE VALUE
PRESS SET KEY
TO INCREASE MEMORY WEIGHT
TO INCREASE MEMORY WEIGHT PRESS MT KEY & INSTALL THE MEMORY.
TO SEE THE TOTAL VALUE, PRESS MR KEY. & AGAIN PRESS MR KEY TO
CLOSE.
TO CLEAR THE MEMORY PRESS ACL KEY.
TO SEE VALUE OF 0 TO 99 MEMORY, PRESS *(STAR).
THE DISPLAY WILL SHOW 0 blank. ENTER ANY NUMBER BETWEEN 0 TO 99 and
PRESS *,WILL SHOW YOU THE VALUE OF MEMORY.