For those familiar with the Ishida SR-2000a Touch Screen scale, this document may be used as
a quick reference guide. Simply refer to the Table of Contents below and go to the appropriate
page for instructions. It may also be used as a source of detailed step-by-step instructions to
setup and configure the scale.
I. Check and Update Firmware...............................................................................................................2
II. Clear Memory: Standard and Special.................................................................................................4
III. Install RF card.....................................................................................................................................7
IV. Configure IP Address, Subnet Mask, etc............................................................................................8
V. Load i-View Backup File....................................................................................................................11
VI. Setting Up Label Cassette(s)............................................................................................................13
VII. Setting Up Label Specifications ........................................................................................................14
VIII. Enable Ad (Display) Messages:........................................................................................................16
IX. Load PLU File Via ScaleLink Pro......................................................................................................17
X. Create Keyboards: Categories, Presets, and Function Keys............................................................18
A. Importing Key Images into ScaleLink Pro...................................................................................18
B. Assigning Images to Keys ..........................................................................................................18
C. Assig ning Category Keys............................................................................................................19
D. Assigning Function Keys ............................................................................................................19
XI. Appendix............................................................................................................................................21
The SR-2000a uses Compact Flash (CF) memory cards to store both the firmware and images.
All dealers doing any work with the SR-2000a are going to need at least a CF card adapter.
The adapter accepts the CF card and is then inserted into a PCMCIA slot on a notebook
computer. The computer sees the device as another storage drive on the PC allowing the
transfer of files. Rice Lake has two part numbers for these options:
6. Insert Adapter with CF memory card into PCMCIA slot of a notebook computer.
Note: any CF card adaptor may also be used such as an external USB device or CF card
This procedure is for the Special RAM Clear.
If only a standard Memory Clear is required follow steps 1, 2, 13, and 14 only.
Special Memory Clear is only necessary when upgrading from firmware B0485 to B0499B or
later.
1. Press MENU button (Supervisor).
2. Enter TestMenu: 495344 Æ TEST MODE.
3. Select MEMORY DATA MODIFY Æ SRAM DATA MODIFY.
4. Press ASC button to change display to ASCII code from Hex.
5. Enter "10000100" and touch "∨" (DOWN ARROW) button.
6. Display shows "SRAM CLEAR END ???" (16 characters).
7. Key in "0" and touch the [???] position Æ changes to [ _ ].
See Screen 1.
8. Press MENU two times.
9. Skip to step 13if working with an original 1 Meg SR-2000a. Note: Any SR-2000a with serial number 5031600 or higher has 2 Meg of memory.
10. Select MEMORY CLEAR.
11. Perform the
a. Press CLEAR Æ press EXECUTE Æ "Normal" is displayed.
b. Note the memory has decreased from approx 2 Meg to 1 Meg.
See Screen 2.
c. Press MENU.
12. Reinitialize the memory to full capacity.
a. Enter 495344, press MEMORY DATA MODIFY.
b. Press SRAM FORMAT.
c. Press MAX Æ press EXECUTE Æ "Normal" is displayed and "All Memory" has
increased from approx 1 Meg to 2 Meg.
See Screen 3.
d. Press MENU two times.
13. Select MEMORY CLEAR.
14. Perform three standard clears: SRAM Clear, System Initialize, and Test Data Set.
See Screen 2.
a. Press CLEAR Æ press EXECUTE Æ "Normal" is displayed.
b. Press INITIALIZE Æ press EXECUTE Æ "Normal" is displayed.
c. Press SET Æ press EXECUTE Æ "Normal" is displayed.
d. Press MENU.
only the first memory clear: SRAM Clear.
Rev 1, September 2006 4 / 21 SR-2000a Quick Setup
Page 5
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
15. After Special RAM Clear, it is necessary to set and adjust the following.
a. Calibrate Touch Panel
i. From Test Menu select KEY CHECKÆTOUCH PANEL ADJUST
ii. Follow screen directions: [three "+" marks]
Note:
iii. Press MENU two times.
b. Initialize Printer
i. From Test Menu select PRINTER ADJUSTMENT.
ii. Press EXECUTE {MEMORY INITIALIZE (red box)} Æ "Normal" is displayed.
iii. Press MENU two times.
c. Set Date & Time
i. Enter Programming Menu
ii. Enter Date and Time values in formats noted on display.
iii. Press MENU.
16. Power OFF, Power ON.
do not follow the final step to Initialize, this will reset the calibration.
See Screen 4.
Screen 1. Setting Special RAM Clear Flag
Rev 1, September 2006 5 / 21 SR-2000a Quick Setup
Page 6
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
Screen 2. Memory Cleared
Screen 3. SRAM -- Formatted to Max Memory (2 Meg)
Rev 1, September 2006 6 / 21 SR-2000a Quick Setup
Page 7
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
Screen 4. Printer Memory Initialized
III. Install RF card
If the SR-2000a will be part of a wireless communication network the Symbol RF PCMCIA card
must be installed.
p/n 88313 Symbol PCMCIA RF card (LA-4121)
1. With the SR-2000a in OFF position remove left side white access panel.
2. Remove the small PCMCIA card bronze access cover by removing one Phillips screws.
3. Insert the Symbol PCMCIA card into the upper slot ("Slot 2").
See Figure 3.
Note: the RF card can be inserted into either slot but only the lower slot can be used for
some special functions.
4. Power Scale ON.
5. Confirm the green LED on the Symbol RF card begins to flash after 15 seconds.
Note: If the green LED does not flash, turn OFF power and fully reseat the card.
6. Replace the outer white access panel.
Rev 1, September 2006 7 / 21 SR-2000a Quick Setup
Page 8
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
Figure 3. Symbol PCMCIA RF card (LA-4121)
IV. Configure IP Address, Subnet Mask, etc.
This section covers setting the scale's IP Address, Subnet Mask, etc. Instructions are also
included for wireless configuration when the SR-2000a is equipped with the Symbol PCMCIA
Wireless card.
1. Press MENU button (Supervisor).
2. Enter SystemMenu: 495344ÆPLU key.
3. Select OPTION SET
4. Select ETHERNET CARD
5. Select RF LAN
6. Set Computer IP Address (labeled as "Host IP Address" in early versions)
See Screen 5.
7. Set Scale IP Address (labeled as "Target IP Address" in early versions)
8. Set Subnet Mask
Example: 255.255.255.0
9. Set Gateway = 0.0.0.0
Note: If the scale will be on a WAN, your customer will provide the Gateway IP Address.
10. Press FIX key to save settings Æ press EXECUTE
11. The SR-2000a will automatically reboot.
NOTE: The Ethernet setup is complete if using a wired LAN connection - proceed to the next
section.
Rev 1, September 2006 8 / 21 SR-2000a Quick Setup
Page 9
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
12. After scale reboots reenter LAN setting page (steps 1 -- 5 above).
13. Press PAGE to set wireless data.
See Screen 6.
14. Set Comm Mode =
15. Set WEP Encryption mode
• Set
• Set
INVALID if no encryption is used Æ skip to step 18.
40 BIT or 128 BIT based on the key size if encryption will be used.
16. Press ASC key to select
• Encryption keys must be the following length:
o 40-bit ASCII = 5 characters
o 128-bit ASCII = 13 characters
o 40-bit Hex = 10 characters
o 128-bit Hex = 26 characters
Notes - The customer should provide the WEP Encryption key value to be used.
- If this is an initial installation use a unique, random key value.
17. Use the touch screen to enter the WEP Key value, press WEP KEY 0 area.
Example (40-bit, Hex format): "fd494a69bc"
18. Press HEX key to select ASC (use ASCII characters for the Network Name).
19. Use green button to switch between upper and lower case letters and symbols.
20. Enter the Network Name (SSID) of the store's Access Point(s) Æ press ESS-ID
Example: "WaveLAN Network"
Note: The ESS-ID is case sensitive.
21. Press FIX key to save settings.
22. On the next page check for connection:
See Screen 7.
23. Press PING to confirm connection with Computer Æ should receive 2 response packets.
24. Press MENU, MENU, MENU and return to Operation mode.
INFRASTRUCTURE
Hexadecimal or ASCII encryption key format.
Comm. Quality = 15 - 30, not 0
Rev 1, September 2006 9 / 21 SR-2000a Quick Setup
Page 10
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
Screen 5. Ethernet Setting Data
Rev 1, September 2006 10 / 21 SR-2000a Quick Setup
Screen 6. RF Setting Data
Page 11
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
Screen 7. RF Signal Checking and Ping Test
V. Load i-View Backup File
If available, load an i-View backup file.
1. Open i-View (version 1.24 or later).
2. Add the SR-2000a if necessary.
a. From the Setup Menu select Scale Comms.
b. Select ADD.
c. Select SR-2000a.
d. Enter the scale's
e. Add an identifying name to the
f. Select OK, CLOSE.
3. Select the Backup & Restore tab.
4. Highlight the SR-2000a in the left-side window.
5. In the Restore box (lower, right-side) select SELECT.
6. Navigate to the desired backup file, select OPEN.
7. Select Restore Scale.
8. Select "Standard Restore or Scale to Scale Copy".
See Screen 8.
9. Select the Scale Configuration box, select OK Æ data transfer begins.
IP Address, select OK.
Link Name field such as "Meat #1".
Rev 1, September 2006 11 / 21 SR-2000a Quick Setup
Page 12
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
IMPORTANT - The items listed below are not included in the i-View back and must be set
separately. Refer to the following sections for details to make these settings.
Rev 1, September 2006 12 / 21 SR-2000a Quick Setup
Page 13
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
VI. Setting Up Label Cassette(s)
Although the Label Formats are restored by i-View, the Label Cassette settings are not.
1. Press MENU button (Supervisor).
2. Enter SystemMenu: 495344ÆPLU key.
3. Select CASSETTE SET.
See Screen 9.
4. Enter format number:
Note: See the Appendix at the end of this document for the label formats included in the
SR-2000a demo file.
5. Set
6. Set
7. Press PAGE.
8. Set
9. Set
10. Press PAGE.
11. Enable
12. Press PAGE.
13. Set
14. Press MENU, MENU and return to Operation mode.
LABEL SPEC as needed -- see section VII, "Setting Up Label Specifications" for details.
INDIV W/BACK based on department.
MANUAL/AUTO based on department.
CONTINUOUS/DIE-CUT as needed.
SHOP/ADDRESS and FIELD TITLE printing as needed.
OVER LEN FLAG = 1 "Print to Max".
Rev 1, September 2006 13 / 21 SR-2000a Quick Setup
Screen 9. Label Cassette Settings
Page 14
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
VII. Setting Up Label Specifications
Two labels: 64x47mm and Continuous, require special settings to print properly. All other labels
should be set to use the default Label Spec "01".
1. Press MENU button (Supervisor).
2. Enter SystemMenu: 495344ÆPLU key.
3. Select LABEL SET.
4. For Continuous labels
a. Set
b. Set
Label Spec. = 02
Label Gap = 10.0 mm
5. For 64x47mm labels
a. Set
b. Set
c. Set
d. Set
Label Spec. = 03
Label Gap = 2.5 mm
Preprint Feed = 8.5 mm
Back Feed = Yes
6. Press MENU, MENU and return to Operation mode.
perform the following. See Screen 10.
perform the following. See Screen 11.
Screen 10. Label Specification for Continuous Label
Rev 1, September 2006 14 / 21 SR-2000a Quick Setup
Page 15
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
Screen 11. Label Specification for 64x47mm Label
Rev 1, September 2006 15 / 21 SR-2000a Quick Setup
Page 16
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
VIII. Enable Ad (Display) Messages:
Although the Advertising (Scrolling) Message are restored by i-View, the settings for which
messages to display and when are not.
1. Press MENU button (Supervisor).
2. Enter ProgrammingMenu: PROGRAMMING button. Note: The password 9000 may be required.
3. Select AD MSG.
See Screen 12.
4. Enter 1, press left most blank yellow button.
5. Set the
6. Set the
7. Set number of times to
8. Repeat for additional message numbers using the next available yellow button.
9. Press MENU, MENU and return to Operation mode.
Note: The message text can be edited as needed:
a. Enter the Message numberÆ press the SCROLL No button (top, left)
b. Press the green EDIT button.
c. Edit the text as needed Æ press RETURN.
Display Method: FLASH or SCROLL.
Display Speed: FAST, MID, or SLOW.
Repeat (for flashing messages).
Screen 12. Advertising Message Setup - set to display message 1~7
Rev 1, September 2006 16 / 21 SR-2000a Quick Setup
Page 17
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
IX. Load PLU File Via ScaleLink Pro
Although the PLU file may have been downloaded using i-View, a more current PLU file may be
available in ScaleLink Pro. This procedure can be used to update any files such as Messages,
Keyboards, etc.
1. Open ScaleLink Pro (version 3.24c or later).
2. Add the SR-2000a if necessary.
a. From the Setup Menu select Comms (On Line).
b. Select ADD.
c. Select SR-2000a.
d. Enter the scale's
e. Add an identifying name to the
f. Select OK, CLOSE.
3. From the Comms Menu select Show Comms Status.
4. Verify the SR-2000a
5. Select the Send/Receive tab.
See Screen 13.
6. From the
7. From the
Scale drop down menu select the SR-2000a .
Send/Receive Data drop down menu select PLU Æ Select Send to Scale.
8. Repeat for other data files as needed.
IP Address, select OK.
Link Name field such as "Meat #1".
Status is "Connected".
Screen 13. ScaleLink Pro Communication Center
Rev 1, September 2006 17 / 21 SR-2000a Quick Setup
Page 18
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
X. Create Keyboards: Categories, Presets, and Function Keys
As noted in section V. "Load i-View Backup File" above, key images are not saved in an i-View
backup file. If images are to be used they should be imported into ScaleLink Pro before
creating the Category, Function Key, and PLU Preset pages.
See screens 14, 15, and 16 for samples Category, Function Key, and PLU Preset pages.
A. Importing Key Images into ScaleLink Pro
The desired key images are loaded one at a time from within the ScaleLink Pro program. The
library of key images must be available in the computer or on a CD.
1. Open ScaleLink Pro (version 3.24c or later).
2. Add the SR-2000a if necessary.
Note: See section IX. "Load PLU File Via ScaleLink Pro" for details to add an SR-2000a.
4. From the Scales menu select SR-2000a Images.
5. Select Add.
6. Navigate in Windows
7. Repeat adding images as needed.
®
as usual to select an image from the library.
B. Assigning Images to Keys
1. From the Scales menu select Memo/SR-2000a Presets.
2. If prompted, select the desired scale.
3. Select a page from the left hand box.
4. Double click the desired key.
5. Set the
Key Size (the library contains images for large and mediums size keys).
6. Use the "Image ID" pull down list to select an image.
Note: Only images for the selected key's size are listed.
7. Select the desired
8. Enter the
9. Enter the
Key Data to specify the item.
Key Text as needed.
Key Type from the pull down menu.
Notes: If an image is added to a key only one line of text can be entered. The text size is
fixed.
10. After a key has been configured, select OK. Note: When the full keyboard is displayed, the highlighted key's image is not shown.
11. Repeat for additional keys.
12. Select SAVE. If the keyboard is not saved all changes will be lost.
Rev 1, September 2006 18 / 21 SR-2000a Quick Setup
Page 19
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
C. Assigning Category Keys
Setting up Category keys is a two step process. First, Category keys are created on the
Category Key Page then one Group key is assigned to each Preset Key Page to complete the
link.
1. From the Scales menu select Memo/SR-2000a Presets.
2. If prompted, select the desired scale.
3. Select the
4. Double click the desired key.
5. Set the
6. In the
7. Repeat for additional Categories.
Note: Do not duplicate the Category numbers. This is possible in early versions of
8. Select a
9. Double click the desired key.
10. Set the
11. In the
12. Repeat for additional Preset Key Pages.
Note: Assign only one Group key per Preset Key Page.
13. Select SAVE. If the keyboard is not saved all changes will be lost.
Category Key Page.
Key Type as Category.
Key Data, enter a unique number.
ScaleLink Pro.
Preset Key Page.
Key Type as Group.
Key Data drop down menu select the appropriate Category.
D. Assigning Function Keys
The Function Key page is displayed after a PLU has been selected. Function keys allow
temporary changes such as tares, date changes, discounts, etc.
1. From the Scales menu select Memo/SR-2000a Presets.
2. If prompted, select the desired scale.
3. Select the
Function Key Page.
4. Double click the desired key.
5. Set the
6. In the
Key Type as desired.
Key Data, enter a numeric value as needed.
7. Repeat for additional Function Keys.
8. Select SAVE. If the keyboard is not saved all changes will be lost.
Rev 1, September 2006 19 / 21 SR-2000a Quick Setup
Page 20
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
Screen 14. Sample Category Screen with Categories and PLU Presets
Screen 15. Sample Function Key Screen
Rev 1, September 2006 20 / 21 SR-2000a Quick Setup
Page 21
Ishida SR-2000a Touch Screen Scale and Printer
Quick Setup Instructions
Screen 16. Sample PLU Preset Screen - "Pies" Category
XI. Appendix
1. Label sizes
SR-2000a Demo Program Label Formats:
21: 64x145mm - Bakery with Nutrition, landscape
22: 64x59mm - COOL label
23: 64mm - Continuous with Reduced Safe Handling
24: 64x73mm - Safe Handling with Logo
Revised SR-2000a Demo Program Label Formats - continuous strip:
2: 64x47mm - Standard UPC
6: 64x145mm - Bakery with Nutrition (with TransFat), landscape
22: 64x59mm - COOL label
23: 64mm - Continuous with Reduced Safe Handling
31: 64x73mm - Safe Handling with Logo
32: 64x83mm - Safe Handling with Lot No. & COOL
Rev 1, September 2006 21 / 21 SR-2000a Quick Setup