ISHIDA IGB Series, IGX Series, IGB-60, IGB-150, IGX-60 Operation Manual

...
Manual No. 0202A PN 86545
Platform Scale
IGX/IGB Series
Kg/Lb Specification
Operation Manual
IGX Series IGB Series
Do not carry out installation, operation, service, or
maintenance until thoroughly understanding the contents of this manual.
Keep this manual available at all times for installation, operation
, service, and maintenance.
IGX/IGB Series Operation Manual No. 0202A
PREFACE
Thank you for purchasing an Ishida IGX/IGB Series. The IGX/IGB Series is a high-performance Platform Scale that weighs items precisely. This manual explains the operation procedures, cautions for use, etc. of the IGX/IGB Series. Please read this manual fully so that you can use the IGX/IGB Series safely and effectively. Failure to follow the instructions in this manual may result in loss or serious injury, damage to the machine or faulty operation.
NOTE This product cannot be used for certifying weight transactions.
y No part of this manual may be reproduced in any form, by mimeograph or any other means,
without written permission of the publisher.
y Design and specifications are subject to change without notice.
y There may be cases where the contents of this manual may not conform to the actual operations
due to modifications to the machine or other reasons.
y Please convey your comments to your nearest Ishida dealer should you notice any errors or
discrepancies in the contents of this manual.
Copyright © 2003 by Ishida Co., Ltd. All Rights Reserved.
No part of this manual may be reproduced in any form, by mimeograph or any other means, without written permission of the publisher.
IGX/IGB Series Operation Manual No. 0202A page i
CONTENTS
Chapter 1 BEFORE OPERATING MACHINE................................................... 1
1.1 Caution for Handling............................................................................ 2
1.2 Name and Function of Each Part ........................................................ 4
1.3 Installation ........................................................................................... 5
1.4 Start and Stop of Operation ................................................................. 7
1.5 Daily Care............................................................................................ 8
Chapter 2 PRESET FUNCTION ........................................................................ 9
2.1 Presetting the Values......................................................................... 10
2.2 Calling Up the Preset Values............................................................. 14
Chapter 3 WEIGHING ..................................................................................... 15
3.1 Weighing Non-PLUs.......................................................................... 16
3.2 Weighing PLUs.................................................................................. 18
Chapter 4 SETTING MODE............................................................................. 21
4.1 Setting Method .................................................................................. 22
4.2 Set Values List................................................................................... 24
Chapter 5 BATTERY CHECK.......................................................................... 27
5.1 Checking Battery Voltage .................................................................. 28
Chapter 6 APPENDIX ..................................................................................... 31
6.1 Troubleshooting................................................................................. 32
6.2 Specifications .................................................................................... 33
IGX/IGB Series Operation Manual No. 0202A page 1
1
BEFORE OPERATING MACHINE
BEFORE
OPERATING
MACHINE
1
1.1 Caution for Handling
page 2 IGX/IGB Series Operation Manual No. 0202A
1.1 CAUTION FOR HANDLING
Safety Considerations
To ensure the safe operation of this machine, the general safety considerations below must be followed:
Grounding To avoid potential shock hazards, a protective grounding conductor for the machine must be securely connected.
Do not disassemble or modify the machine
Doing so may result in physical injury or damage to the machine.
Do not remove covers or housing
To avoid personal injury and shock, do not open or remove any covers or casing of the machine unless specified in this manual.
Do not perform unspecified maintenance
For your own personal safety, do not perform any maintenance procedures which are not specified in this manual.
Disconnect the power supply before servicing
To ensure your safety, disconnect the power supply before servicing.
Symbols Used in This Manual
This manual uses the following symbols to emphasize important information. Fully understanding the meaning of the symbols will facilitate the use of this manual.
Symbol Meaning
Indicates information that, if not heeded, could result in faulty operation, damage to the machine, or relatively serious injury.
Symbol Meaning
NOTE
Indicates additional information of particular importance. Indicates information to help your understanding of the related text. Indicates a page to refer to.
1.1 Caution for Handling
IGX/IGB Series Operation Manual No. 0202A page 3
1
BEFORE OPERATING MACHINE
Avoid Locating the Machine in the Following Places
A place subject to high temperature or high humidity.
A place exposed to direct sunlight or direct cold air.
A place where water or other liquids may be spilled on the machine.
A place subject to a lot of dust or dirt.
A place subject to strong wind.
A place where the floor or ground is not level or unstable.
Power Supply
Always operate the machine with the specified AC voltage.
1.2 Name and Function of Each Part
page 4 IGX/IGB Series Operation Manual No. 0202A
1.2 NAME AND FUNCTION OF EACH PART
Appearance
IGX Series IGB Series
Display Unit
IGX Series IGB Series
Used to turn the power on or off.
Used to set the scale weight to zero, or increase the value on the display.
Used to set the tare weight, or decrease the value on the display.
Used to move the digit position or finish a setting procedure.
Used to determine or call-up the setting.
1.3 Installation
IGX/IGB Series Operation Manual No. 0202A page 5
1
BEFORE OPERATING MACHINE
1.3 INSTALLATION
Assembling the Scale
1
Remove the two hex-headed bolts from the bottom of the display pole.
2
Carefully insert the bottom of the display pole into the base bracket while pulling out the slack in the cables.
CAUTION
If the cable insulation is damaged, water may penetrate into the cable and cause inaccurate weighing, or the core material may corrode, causing the scale to fail.
3
Tighten the two hex-headed bolts with an Allen wrench.
4
Bundle the excessive cables with a clamp so as to prevent cable damage.
1.3 Installation
page 6 IGX/IGB Series Operation Manual No. 0202A
5
Carefully carry and place the Weigh Platter over the Platter Support.
Leveling the Scale
Use the level adjuster until the air bubble inside the level is positioned in the center of the circle.
Adjusting the Display Unit Angle
After loosening the display unit tightening knob, adjust the unit to an easy-to see angle. Then re-tighten the knob.
1.4 Start and Stop of Operation
IGX/IGB Series Operation Manual No. 0202A page 7
1
BEFORE OPERATING MACHINE
1.4 START AND STOP OF OPERATION
This section explains how to start and stop the machine operation.
Starting Machine Operation
1
Make sure that nothing is placed on the weigh platter.
2
Press the ON/OFF key to turn on the power. Then, the self-diagnostic display appears and all display segments are lit.
IGX Series IGB Series
Ä
Make sure that the initial display appears and the “ZERO” indicator lights.
3
IGX Series IGB Series
NOTE If the “ZERO” indicator is not lit, press the ZERO key.
Stopping Machine Operation
1
Press the ON/OFF key to stop the machine operation.
IGX Series IGB Series
Ä
NOTE When the scale has not been used for a long time, the scale will be automatically turned off.
1.5 Daily Care
page 8 IGX/IGB Series Operation Manual No. 0202A
1.5 DAILY CARE
Daily care will ensure the long life of this machine, and can prevent potential trouble or failure. Also, cleaning the machine after operation is recommended.
CAUTION
To ensure your personal safety, disconnect the power plug from the outlet before any servicing or cleaning.
Clean the outer surface of the machine with a soft cloth soaked with a water-diluted neutral detergent. Then, wipe it with a soft and dry cloth.
`
CAUTION
Do not use thinner or chemicals other than a water-diluted neutral detergent.
IGX/IGB Series Operation Manual No. 0202A page 9
2
PRESET FUNCTION
PRESET
FUNCTION
2
2.1 Presetting the Values
page 10 IGX/IGB Series Operation Manual No. 0202A
2.1 PRESETTING THE VALUES
Selecting the PLU No.
When the power is turned OFF,
1
IGX Series IGB Series
press the ON/OFF key, then the self-diagnosis display appears.
IGX Series IGB Series
Ä
Immediately press the SET key while all display segments are lit. PLU 1 will be displayed.
2
IGX Series IGB Series
Ä
3
Repeat to press either the ZERO (+) or TARE (-) key until the desired PLU No. appears on the display.
[Example] Selecting PLU 2
IGX Series IGB Series
or
Ä
2.1 Presetting the Values
IGX/IGB Series Operation Manual No. 0202A page 11
2
PRESET FUNCTION
Setting the Tare Weight
4
Press the SET key to display the tare weight for the selected PLU.
IGX Series IGB Series
Ä
5
Move the flashing digit to the desired position by pressing the COLUMN key.
IGX Series IGB Series
Ä
6
Increase or decrease the numeric value by pressing the ZERO (+) or TARE (-) key. Then, press the COLUMN key to determine the value. Repeat this step until completing the entry.
[Example] Tare weight 250g
or
Ä
Ä
IGX Series IGB Series
Setting the Upper Limit Value
7
Press the SET key to determine the tare weight and move to the display for setting the upper limit value. Move the flashing digit to the desired position by pressing the COLUMN key.
IGX Series IGB Series
Ä
2.1 Presetting the Values
page 12 IGX/IGB Series Operation Manual No. 0202A
8
Increase or decrease the numeric value by pressing the ZERO (+) or TARE (-) key. Then, press the COLUMN key to determine the value. Repeat this step until completing the entry.
[Example] Upper limit value 1000g
or
Ä
Ä
IGX Series IGB Series
Setting the Lower Limit Value
9
Press the SET key to determine the upper limit value and move to the display for setting the lower limit value. Move the flashing digit to the desired position by pressing the COLUMN key.
NOTE If the lower limit value has already been preset, only a value equal to or larger than
this limit value can be set.
IGX Series IGB Series
Ä
2.1 Presetting the Values
IGX/IGB Series Operation Manual No. 0202A page 13
2
PRESET FUNCTION
10
Increase or decrease the numeric value by pressing the ZERO (+) or TARE (-) key. Then, press the COLUMN key to determine the value. Repeat this step until completing the entry.
[Example] Lower limit value 500g
or
Ä
Ä
IGX Series
IGB Series
Setting Values for Other PLUs
11
Press the SET key to determine the lower limit value. Repeat steps 3 through 10 above for setting the values for other PLUs.
NOTE If the upper limit value has already been preset, only a value equal to or less than this
limit value can be set.
Finishing the Setting Procedures
Press the COLUMN key to finish the setting procedure.
IGX Series IGB Series
12
Ä
2.2 Calling Up the Preset Values
page 14 IGX/IGB Series Operation Manual No. 0202A
2.2 CALLING UP THE PRESET VALUES
1
Press and hold the SET key for two seconds. “PLU 1” will be displayed.
IGX Series IGB Series
(2 sec.)
Ä
2
Press the ZERO (+) or TARE (-) key to select the desired PLU No.
IGX Series IGB Series
or
Ä
3
Press the SET key to display the tare weight, the upper limit value, and the lower limit value.
IGX Series IGB Series
Ä
b
b
b
b
NOTE If no tare weight has been set, or if neither the upper limit value nor the lower limit
value has been set, the values set before pressing the SET key will remain active.
IGX/IGB Series Operation Manual No. 0202A page 15
3
WEIGHING
WEIGHING
3
3.1 Weighing Non-PLUs
page 16 IGX/IGB Series Operation Manual No. 0202A
3.1 WEIGHING NON-PLUs
1
When the power is turned OFF,
IGX Series IGB Series
press the ON/OFF key to turn on the power, the self-diagnosis display will start, then stop at the initial display with “ZERO” indicator lit.
IGX Series IGB Series
Ä
NOTE If “ZERO” indicator is not lit, press the ZERO key to initialize the display.
2
Place a tare on the weigh platter, and press the TARE key to subtract the weight. The “NET” indicator will be lit.
[Example] Tare weight: 180g
IGX Series IGB Series
Ä
3
Place an item on the weigh platter. The display will show the net weight.
[Example] Net weight: 2,280g
Ä
IGX Series
IGB Series
3.1 Weighing Non-PLUs
IGX/IGB Series Operation Manual No. 0202A page 17
3
WEIGHING
4
When setting “kg” or “lb” select the desired weight unit by pressing the ZERO key and TARE key at the same time.
Ä
At the same time
IGX Series IGB Series
NOTE 1. Either “kg” or “lb” indicator will be lit.
2. This function is available only when nothing is placed on the platter.
3.2 Weighing PLUs
page 18 IGX/IGB Series Operation Manual No. 0202A
3.2 WEIGHING PLUs
1
When the power is turned OFF,
IGX Series IGB Series
press the ON/OFF key to turn on the power, the self-diagnosis display appears, then stop at the initial display with “ZERO” indicator lit.
IGX Series IGB Series
Ä
NOTE If “ZERO” indicator is not lit, press the ZERO key to initialize the display.
Press the SET key, then “PLU 1” appears on the display.
IGX Series IGB Series
2
Ä
If necessary, repeat to press either the ZERO (+) or TARE (-) key until the desired PLU No. appears on the display.
[Example] Selecting PLU 2
IGX Series IGB Series
or
Ä
3.2 Weighing PLUs
IGX/IGB Series Operation Manual No. 0202A page 19
3
WEIGHING
3
Press the SET key to display the tare weight, upper limit value, and lower limit value for the selected PLU.
[Example] Tare weight 250g Upper limit value 1000g Lower limit value 500g
IGX Series IGB Series
Ä
b b
b b
b
b
4
Place the item on the weigh platter. The display will show the net weight.
[Example] Net weight 5,970g
IGX Series IGB Series
Ä
NOTE y When the net weight exceeded the programmed upper weight limit, the “OVER”
indicator will light up.
y When the net weight did not reach the programmed lower weight limit, the
“UNDER” indicator will light up.
y When the net weight is between the upper and lower weight limits, the “ACCEPT”
indicator will light up.
3.2 Weighing PLUs
page 20 IGX/IGB Series Operation Manual No. 0202A
5
After determining the PLU item weight, remove it from the weigh platter.
6
When weighing the same PLU item again, repeat steps 4 and 5 above.
NOTE When weighing a different PLU item, repeat steps 2 through 5 above.
7
To confirm the preset tare, press the COLUMN key.
IGX/IGB Series Operation Manual No. 0202A page 21
4
SETTING MODE
SETTING
MODE
4
4.1 Setting Method
page 22 IGX/IGB Series Operation Manual No. 0202A
4.1 SETTING METHOD
When the power supply is turned OFF,
press the ON/OFF key to turn ON the power, then immediately press the COLUMN key while all display segments are lit. Then, the set value number of Setting No. 1 appears.
Ä
Ä
IGX Series
IGB Series
1
Change the set value by pressing the ZERO(+) key or TARE(-) key. When not changing the setting value, just press the SET key.
IGX Series IGB Series
2
or
Ä
3
Select the desired Setting No. by pressing the SET key. Return to step 2 above.
IGX Series IGB Series
Ä
4.1 Setting Method
IGX/IGB Series Operation Manual No. 0202A page 23
4
SETTING MODE
4
Press the COLUMN key to finish the setting procedure.
IGX Series IGB Series
Ä
For descriptions of the setting numbers and the setting conditions of the setting value numbers, refer to the Set Value List on the following page.
4.2 Set Value List
page 24 IGX/IGB Series Operation Manual No. 0202A
4.2 SET VALUE LIST
IGX Series
Setting
No.
Description of Setting
Setting
Value No.
Setting Condition
00 All key valid F01 Key selection
01 ON/OFF key invalid
(Always scale operation status when the power is turned ON)
00 No function F02 Automatic call of preset number
01 Preset No. 1 is automatically called when
power supply is turned ON.
F03 No function
F04 No function
F05 No function
F06 No function
F07 No function
F08 No function
F09 No function
F10 No function
F11 No function
F12 No function
F13 No function
F14 No function
F15 No function
00 During stable weighing outside limit
01 During stable weighing under "OK" condition
02 During stable weighing under "OVER"
condition
03 No buzzer sounds even when key input is
made.
04 Buzzer sounds when key input is made and
during stable weighing.
05 Buzzer sounds only when key input is made
F16 Buzzer sounding
(When the buzzer is installed)
06 Upper/lower limits discrimination function
(during stable/unstable weighing)
00 No function
01 10 minutes
02 20 minutes
03 30 minutes
04 40 minutes
05 50 minutes
F17 Automatic power-off time
06 60 minutes
NOTE Shaded areas are factory default settings.
4.2 Set Value List
IGX/IGB Series Operation Manual No. 0202A page 25
4
SETTING MODE
IGB Series
Setting
No.
Description of setting
Setting
value No.
Setting condition
F01 No function
00 No function provided F02 Function to automatically call preset
No.
01 Preset No. 1 is automatically called
when power supply is ON.
F03 No function
F04 No function
F05 No function
F06 No function
F07 No function
F08 No function
F09 No function
F10 No function
F11 No function
F12 No function
F13 No function
F14 No function
F15 No function
F16 No function
00 No function
01 10 minutes
02 20 minutes
03 30 minutes
04 40 minutes
05 50 minutes
F17 Setting automatic power-off time
06 60 minutes
NOTE Shaded areas are factory default settings.
page 26 IGX/IGB Series Operation Manual No. 0202A
MEMO
IGX/IGB Series Operation Manual No. 0202A page 27
5
BATTERY CHECK (For IGB Series Only)
For IGB Series Only
BATTER
Y
CHEC
K
5
5.1 Checking Battery Voltage
page 28 IGX/IGB Series Operation Manual No. 0202A
5.1 CHECKING BATTERY VOLTAGE
1
Press the ON/OFF key, then the self-diagnosis display appears.
Ä
2
Immediately press the TARE key. The battery check display will appear to check the remaining battery capacity.
Ä
[Example] Voltage (for reference) 2.8 V
NOTE Since rechargeable batteries have a normal voltage of 1.2 V (2.4V for two
batteries), their voltage cannot be indicated even when they are fully charged.
[Example] Voltage (for reference) 2.6 to 2.8 V
[Example] Voltage (for reference) 2.4 to 2.6 V
5.1 Checking Battery Voltage
IGX/IGB Series Operation Manual No. 0202A page 29
5
BATTERY CHECK (For IGB Series Only)
[Example] Voltage (for reference) 2.2 to 2.4 V
[Example] Voltage (for reference) 2.0 to 2.2 V
[Example] Voltage (for reference) less than 2.0 V
(when batteries have to be replaced)
Press any key other than the TARE key to cancel the battery check display.
3
Ä
NOTE When it is necessary to replace the batteries when in use, the battery-replacement
symbol will illuminate and the display indicating all numeric values will appear.
page 30 IGX/IGB Series Operation Manual No. 0202A
MEMO
IGX/IGB Series Operation Manual No. 0202A page 31
6
APPENDIX
A
PPENDI
X
6
6.1 Troubleshooting
page 32 IGX/IGB Series Operation Manual No. 0202A
6.1 TROUBLESHOOTING
If an error occurs while using the scale, take appropriate measures according to instructions in the following table. If you have any other problems, contact your nearest ISHIDA dealer.
Symptom Measures
The display unit does not indicate any value or symbol when the ON/OFF key is pressed.
y Check the power source.
“0” does not appear after finishing a display check.
y Place the scale on a stable flat surface. y Use the level adjuster to stabilize the scale. y Protect the scale from strong winds. y Don’t place the item close to the display pole.
The weight results are different.
y Place the scale on a stable flat surface or table. y Check that there is nothing on the scale. y Use the level adjuster to stabilize the scale. y Protect the scale from strong winds.
6.2 Specifications
IGX/IGB Series Operation Manual No. 0202A page 33
6
APPENDIX
6.2 SPECIFICATIONS
IGX Series
Item Contents
Model Name IGX-60 IGX-150
<OIML Approved>
Weighing Capacity 60 kg / 150 lb 150 kg / 300 lb
Graduation 0.02 kg / 0.05 lb 0.05 kg / 0.1 lb
Accuracy 1/3000
Weigh Platter 550mm (L) x 400mm (W)
Exterior Material
Display: ABS resins Display pole: Aluminum die-cast Weighing platter: Stainless (SUS304)
Display Angle Adjust
Angle adjustable from the horizon (0°) to the front, Knob locking method
Weight 16.8kg
Environmental Condition
Temperature from -5°C to +40°C, Relative humidity 80%RH (max.) without condensation
Power Source
The required transformer is provided for each 100VAC, 120VAC, 220VAC, or 240VAC.
Power Consumption
120VAC: 46 mA
Display
x VFD
Numerics: 5 + 1/2 digits, Height 29 mm Mark: Zero point, Now subtracting tare, Stable
x LED
Over, Under, Accept
Tare Subtraction
x Key-in tare x Preset tare
Preset Function
[Program Mode] 10 PLUs from PLU 1 to PLU 10
(Tare weight, Upper limit, Lower limit)
Upper Limit Range More than the lower limit, within 5 digits (99999)
Lower Limit Range Less than the upper limit (5 digits in case of the upper limit = 0)
Auto Power Off [Setup Mode] None/10min./ 20min./ 30min./ 40min./ 50min./ 60min.
Auto Preset Call-up
[Setup Mode] Function “Yes“ / “No“ selection
(PLU 1 is called up when the power is ON.)
Battery Check Mode No
Buzzer Yes
ON/OFF Switch
Option
6.2 Specifications
page 34 IGX/IGB Series Operation Manual No. 0202A
IGB Series
Item Contents
Model Name IGB-60 IGB-150
<OIML Approved>
Weighing Capacity 60 kg / 150 lb 150 kg / 300 lb
Graduation 0.02 kg / 0.05 lb 0.05 kg / 0.1 lb
Accuracy 1/3000
Weighing Platter 550 mm (L) x 400 mm (W)
Exterior Material
Display: ABS resins Display pole: Aluminum die-cast Weighing platter: Stainless (SUS304)
Display Angle Adjust
Angle adjustable from the horizon (0°) to the front, Knob locking method
Weight 16.0 kg (excluding batteries)
Environmental Condition
Temperature from -5°C to +40°C, Relative humidity 80%RH (max.) without condensation
Power Source
Two dray batteries (not attached to machine), or optional AC adapter
[Battery Life]
Conditions: No option, Temperature 20°, Relative humidity 60%RH Two “D” size alkaline batteries (Approx. 500H continuous use)
Power Consumption 2.4 to 6VDC: 25mA
Display
x LCD
Numerics: 6 digits, Height 25 mm Mark: Battery. Zero point, Now subtracting tare, Stable, Weight unit
(kglb), Over, Under, Accept
Tare Subtraction
x Key-in tare x Preset tare
Preset Function
[Program Mode] 10 PLUs from PLU 1 to PLU 10
(Tare weight, Upper limit, Lower limit)
Upper Limit Range More than the lower limit, within 5 digits (99999)
Lower Limit Range Less than the upper limit (5 digits in case of the upper limit = 0)
Auto Power Off [Setup Mode] None/10min./ 20min./ 30min./ 40min./ 50min./ 60min.
Auto Preset Call-up
[Setup Mode] Function “Yes”/”No” selection
(PLU 1 is called up when the power is ON.)
Battery Check Mode Yes
Buzzer No
ON/OFF Switch
Option AC adapter (Dealer option)
44 SANNO-CHO, SHOGOIN, SAKYO-KU KYOTO, 606-8392 JAPAN PHONE: 81-75-771-4141 FACSIMILE: 81-75-751-1634 URL: http://www.ishidajapan.com
Design and specifications are subject to change without notice.