Iseo Zero1 Stylos 2 Installation Manual

Stylos 2 All Weather
INSTALLATION GUIDE (UK)
®
iseo.com
Non contractual document. Subject to change. Cod. 60000STY2CV01.5 - 08/05/2018 Stylos 2 Credential Reader All Weather Inst. guide (GB) - © 2017 Iseo Serrature S.p.a. - www.iseo.com
Iseo Serrature s.p.a Via San Girolamo 13 25055 Pisogne (BS) ITALY Tel. +39 0364 8821 iseo@iseo.com
ELECTRONIC SUPPORT SERVICE
iseozero1.com
WARNINGS
Read this manual prior to use the device in order to ensure a safe and proper use.
Preserve this manual as future reference.
The installation of the device requires the intervention of qualified staff, adequately trained by ISEO.
The instructions should be carefully followed during installation. These instructions and any maintenance instructions should be passed on by the installer to the user.
The product must be destined only for the use for which it is expressly designed and therefore as a credential reader for civil and industrial locations. Any other use is considered improper and dangerous.
The electrical connection must be made according to the constructor's instructions and respecting the regulations in force.
In the event of a failure and/or poor operation, remove the power supply using the main switch and do not tamper with it. For all repairs, exclusively contact a technical assistance center authorized by the constructor.
Before performing any cleaning operation on the product, uncouple the appliance from the electrical power supply network, by opening the system switch.
1. VERSIONS AND DIMENSIONS
Credential reader (outdoor module)
C
A
B
A = 47,5mm B = 17,5mm C = 130mm
Control unit
(indoor module)
A = 45mm B = 19,3mm C = 113mm
Spacer for wall
installation
A = 40mm B = 10mm C = 125mm
This guide includes instruction to configure the Stylos as Stand-Alone gate or as Reader/Validator, connected to Atlas. Refer to the proper section.
2. DISASSEMBLING INDOOR MODULE
PUSH
PUSH
PULL UP
PULL UP
1
2
Side view
Back view
3. STAND-ALONE GATE SETTING
Control Unit Circuit View
J2.1J2.2J2.3J2.
4
JPS
JP6JP4JP2JP
0
S1
Only to set the Stylos 2 All Weather to be used as Stand-Alone gate, you have to close, by a wire, holes 2 and 3 of the green connector shown in the picture.
1
2
3
Fit the wire when the Stylos is OFF.
4
5
Stylos as Stand-Alone gate = Address 0 (Master)
3.1 STAND-ALONE GATE ELECTRICAL CONNECTIONS
Power supply: 8÷30 VDC 0.5A
Minimum/maximum cross-section of the cables is:
(24÷15AWG).
Do not extend the cable supplied with the external device (5 mt).
Install the internal module only in a protected area.
LEGEND:
S1 = Programming button JP 0/2/4/6 = Bus Address Jumpers
JP4JP2JP
BUS ADDRESS
JP
0
6
ADDRESS 0 =
ADDRESS 2 =
ADDRESS 4 =
ADDRESS 6 =
MAX
mm²0.20÷1.5
FUNCTION
(Master)
(slave)
(slave)
(slave)
J2.1J2.2J2.3J2.
JP
JP4JP2JP
6
0
}
BUS
ADDRESS
LOCKBUS
POSITIVE (+) Power Supply
NEGATIVE (-) GND
4
JPS
GREEN + GREY + SHIELD (or black) RED WHITE BROWN YELLOW PINK BLUE
(Communication Channel)
1
2
3
4
5
S1
Control Unit Circuit View
JP6JP4JP2JP
J2.1J2.2J2.3J2.
JPS
0
4
S1
4. READER/VALIDATOR SETTING
Control Unit Circuit View
J2.1J2.2J2.3J2.
4
JPS
JP6JP4JP2JP
0
S1
For more information about Stylos and Atlas, refer to the Atlas Installation Manual available at:
http://gamma.iseozero1.com/en/controllo-accessi/
Stylos as Reader/Validator = Address 1
4.1 READER/VALIDATOR ELECTRICAL CONNECTIONS
Power supply: 8÷30 VDC 0,5A MAX Minimum/maximum cross-section of the
cables is: 0,20÷1,5 mm (24÷15 AWG). Do not extend the cable supplied with the
external device (5 mt.).
Install the internal device only in a protected area.
BUS ADDRESS
ADDRESS 1 =
ADDRESS 2 =
ADDRESS 3 =
ADDRESS 4 =
ADDRESS 5 =
ADDRESS 6 =
ADDRESS 7 =
ADDRESS 8 =
JP 1
JP
JP4JP2JP
6
}
BUS
ADDRESS
LOCKBUS
POSITIVE (+) Power Supply
NEGATIVE (-) GND
J2.1J2.2J2.3J2.
4
JPS
0
GREEN + GREY + SHIELD (or black) RED WHITE BROWN YELLOW PINK BLUE
(Communication Channel)
1
2
3
4
5
JP6JP4JP2JP
S1
Control Unit Circuit View
J2.1J2.2J2.3J2.
4
JPS
0
S1
5. ACTUATOR CONFIGURATION: LOCKBUS SELECTION
6. STAND-ALONE GATE: EXCHANGE OF CODED KEYS WITH ACTUATOR
(JUMPER SETTING)
Switch on the Actuator and check if red led
1
flashes:
1 time (Lockbus 1) = Reader/Validator. 2 times (Lockbus 2) = Stand-Alone gate.
Change the Lockbus type accordingly to your
GND
VCC
I/O 1
I/O 2
IN AN
L2L1P1 P2 LRL
configuration, following the next point.
Pow er supply
÷
24VDC 25W
8
J P2LC HJ P1LV O
Switch on the Actuator keeping pressed both
2
buttons simultaneously for 1 sec. Switch on it again to check if now red led
V2 Output
V1 Output
OPEN
flashes 1 or 2 times. If not repeat the procedure.
Red led flashing
6.1 STAND-ALONE GATE: EXCHANGE OF CODED KEYS WITH ACTUATOR
(EXCHANGE KEYS)
GND
LPW
V PWR +
GND
NO/NC
J P3
COM
EARTH
Set jumpers on Actuator and Stylos Control Unit as per pictures below. Note this configuration is correct only in case of 1 Stylos (Master) and 1 Actuator (Slave).
For more information about jumper setting with different configuration, refer to the Stylos User Manual available at app.iseo.com.
GND
LV O
V1 Output
I/O 1
L2L1P1 P2 LRL
Power s upply 8
OPEN
V2 Output
I/O 2
IN AN
÷
24VDC 25W
J P2L CHJ P1
V PWR +
GND
COM
NO/NC
Control Unit Circuit View
JP6JP4JP2JP
J2.1J2.2J2.3J2.
JPS
0
4
S1
J P3
LPW
GND
EARTH
VCC
Stylos Master
address 0 Actuator address 1
7. INSTALLATION ON A METAL PROFILE
1
2
Switch on the Stylos Control Unit keeping pressed the button and wait for the acustic and light signal, then release it immediately.
S1
Switch on the actua­tor keeping pressed one button for 3 sec.
VCC
GND
V2 Output
V1 Output
I/O 2
I/O 1
IN AN
L2L1P1 P2 LRL
Pow er supply
÷
24VDC 25W
8
J P2LC HJ P1LV O
OPEN
V PWR +
GND
LPW
NO/NC
GND
J P3
COM
EARTH
Control Unit Circuit View
J2.1J2.2J2.3J2.
JPS
JP6JP4JP2JP
0
4
Actuator address 1
Stylos Master address 0
For more information regarding the exchange of keys, see the Tutorial Video available at
app.iseo.com.
8. INSTALLATION ON A WALL
Ø 3.2 mm
(max)
83
26
Ø 26 mm
Ø 3.2 mm
(max)
9. INSTALLATION WITHOUT THE SPACER
3.9 x 19 mm
Ø 5 mm
83
26
Ø 26 mm
Ø 5 mm
9.1 INSTALLATION WITH THE SPACER
3.9 x 30 mm
5 x 25 mm
Take care to not damage the cables while installing the device.
Check the connections on section 5 or 6 before powering the device.
1
2
DRILLING TEMPLATE
Take care to not damage the cables while installing the device.
Check the connections on section 5 or 6 before powering the device.
1
TOP
BOTTOM
2