Stylos 2 All Weather
INSTALLATION GUIDE (UK)
®
iseo.com
Non contractual document. Subject to change. Cod. 60000STY2CV01.5 - 08/05/2018
Stylos 2 Credential Reader All Weather Inst. guide (GB) - © 2017 Iseo Serrature S.p.a. - www.iseo.com
Iseo Serrature s.p.a
Via San Girolamo 13
25055 Pisogne (BS)
ITALY
Tel. +39 0364 8821
iseo@iseo.com
ELECTRONIC SUPPORT SERVICE
iseozero1.com
WARNINGS
Read this manual prior to use the device in order to ensure a safe and proper use.
Preserve this manual as future reference.
The installation of the device requires the intervention of qualified staff, adequately trained by ISEO.
The instructions should be carefully followed during installation. These instructions and any maintenance
instructions should be passed on by the installer to the user.
No modifications of any kind are permitted, except for those described in these instructions.
The product must be destined only for the use for which it is expressly designed and therefore as a
credential reader for civil and industrial locations. Any other use is considered improper and dangerous.
The electrical connection must be made according to the constructor's instructions and respecting the
regulations in force.
In the event of a failure and/or poor operation, remove the power supply using the main switch and do not
tamper with it. For all repairs, exclusively contact a technical assistance center authorized by the constructor.
Before performing any cleaning operation on the product, uncouple the appliance from the electrical power
supply network, by opening the system switch.
1. VERSIONS AND DIMENSIONS
Credential reader
(outdoor module)
C
A
B
A = 47,5mm
B = 17,5mm
C = 130mm
Control unit
(indoor module)
A = 45mm
B = 19,3mm
C = 113mm
Spacer for wall
installation
A = 40mm
B = 10mm
C = 125mm
This guide includes instruction to configure the Stylos as Stand-Alone gate or as
Reader/Validator, connected to Atlas. Refer to the proper section.
2. DISASSEMBLING INDOOR MODULE
PUSH
PUSH
PULL UP
PULL UP
1
2
Side view
Back view
3. STAND-ALONE GATE SETTING
Control Unit
Circuit View
J2.1J2.2J2.3J2.
4
JPS
JP6JP4JP2JP
0
S1
Only to set the Stylos 2 All Weather to be used as
Stand-Alone gate, you have to close, by a wire,
holes 2 and 3 of the green connector shown in the
picture.
1
2
3
Fit the wire when the
Stylos is OFF.
4
5
Stylos as Stand-Alone gate = Address 0 (Master)
3.1 STAND-ALONE GATE ELECTRICAL CONNECTIONS
Power supply: 8÷30 VDC 0.5A
Minimum/maximum cross-section
of the cables is:
(24÷15AWG).
Do not extend the cable supplied
with the external device (5 mt).
Install the internal module only in
a protected area.
LEGEND:
S1 = Programming button
JP 0/2/4/6 = Bus Address Jumpers
JP4JP2JP
BUS
ADDRESS
JP
0
6
ADDRESS 0 =
ADDRESS 2 =
ADDRESS 4 =
ADDRESS 6 =
MAX
mm²0.20÷1.5
FUNCTION
(Master)
(slave)
(slave)
(slave)
J2.1J2.2J2.3J2.
JP
JP4JP2JP
6
0
}
BUS
ADDRESS
LOCKBUS
POSITIVE (+) Power Supply
NEGATIVE (-) GND
4
JPS
GREEN + GREY + SHIELD (or black)
RED
WHITE
BROWN
YELLOW
PINK
BLUE
(Communication Channel)
1
2
3
4
5
S1
Control Unit
Circuit View
JP6JP4JP2JP
J2.1J2.2J2.3J2.
JPS
0
4
S1
4. READER/VALIDATOR SETTING
Control Unit
Circuit View
J2.1J2.2J2.3J2.
4
JPS
JP6JP4JP2JP
0
S1
For more information about Stylos and Atlas, refer to
the Atlas Installation Manual available at:
http://gamma.iseozero1.com/en/controllo-accessi/
Stylos as Reader/Validator = Address 1
4.1 READER/VALIDATOR ELECTRICAL CONNECTIONS
Power supply: 8÷30 VDC 0,5A MAX
Minimum/maximum cross-section of the
cables is: 0,20÷1,5 mm (24÷15 AWG).
Do not extend the cable supplied with the
external device (5 mt.).
Install the internal device only in a protected
area.
BUS
ADDRESS
ADDRESS 1 =
ADDRESS 2 =
ADDRESS 3 =
ADDRESS 4 =
ADDRESS 5 =
ADDRESS 6 =
ADDRESS 7 =
ADDRESS 8 =
JP 1
JP
JP4JP2JP
6
}
BUS
ADDRESS
LOCKBUS
POSITIVE (+) Power Supply
NEGATIVE (-) GND
J2.1J2.2J2.3J2.
4
JPS
0
GREEN + GREY + SHIELD (or black)
RED
WHITE
BROWN
YELLOW
PINK
BLUE
(Communication Channel)
1
2
3
4
5
JP6JP4JP2JP
S1
Control Unit
Circuit View
J2.1J2.2J2.3J2.
4
JPS
0
S1

5. ACTUATOR CONFIGURATION: LOCKBUS SELECTION
6. STAND-ALONE GATE: EXCHANGE OF CODED KEYS WITH ACTUATOR
(JUMPER SETTING)
Switch on the Actuator and check if red led
1
flashes:
1 time (Lockbus 1) = Reader/Validator.
2 times (Lockbus 2) = Stand-Alone gate.
Change the Lockbus type accordingly to your
GND
VCC
I/O 1
I/O 2
IN AN
L2L1P1 P2 LRL
configuration, following the next point.
Pow er supply
÷
24VDC 25W
8
J P2LC HJ P1LV O
Switch on the Actuator keeping pressed both
2
buttons simultaneously for 1 sec.
Switch on it again to check if now red led
V2 Output
V1 Output
OPEN
flashes 1 or 2 times.
If not repeat the procedure.
Red led flashing
6.1 STAND-ALONE GATE: EXCHANGE OF CODED KEYS WITH ACTUATOR
(EXCHANGE KEYS)
GND
LPW
V PWR +
GND
NO/NC
J P3
COM
EARTH
Set jumpers on Actuator and Stylos Control Unit as per pictures below. Note this configuration is
correct only in case of 1 Stylos (Master) and 1 Actuator (Slave).
For more information about
jumper setting with different
configuration, refer to the
Stylos User Manual available
at app.iseo.com.
GND
LV O
V1 Output
I/O 1
L2L1P1 P2 LRL
Power s upply
8
OPEN
V2 Output
I/O 2
IN AN
÷
24VDC 25W
J P2L CHJ P1
V PWR +
GND
COM
NO/NC
Control Unit
Circuit View
JP6JP4JP2JP
J2.1J2.2J2.3J2.
JPS
0
4
S1
J P3
LPW
GND
EARTH
VCC
Stylos Master
address 0
Actuator
address 1
7. INSTALLATION ON A METAL PROFILE
1
2
Switch on the Stylos Control
Unit keeping pressed the
button and wait for the acustic
and light signal, then release it
immediately.
S1
Switch on the actuator keeping pressed
one button for 3 sec.
VCC
GND
V2 Output
V1 Output
I/O 2
I/O 1
IN AN
L2L1P1 P2 LRL
Pow er supply
÷
24VDC 25W
8
J P2LC HJ P1LV O
OPEN
V PWR +
GND
LPW
NO/NC
GND
J P3
COM
EARTH
Control Unit
Circuit View
J2.1J2.2J2.3J2.
JPS
JP6JP4JP2JP
0
4
Actuator
address 1
Stylos Master
address 0
For more information regarding the exchange of keys, see the Tutorial Video available at
app.iseo.com.
8. INSTALLATION ON A WALL
Ø 3.2 mm
(max)
83
26
Ø 26 mm
Ø 3.2 mm
(max)
9. INSTALLATION WITHOUT THE SPACER
3.9 x 19 mm
Ø 5 mm
83
26
Ø 26 mm
Ø 5 mm
9.1 INSTALLATION WITH THE SPACER
3.9 x 30 mm
5 x 25 mm
Take care to not
damage the cables
while installing the
device.
Check the connections
on section 5 or 6
before powering the
device.
1
2
DRILLING TEMPLATE
Take care to not
damage the cables
while installing the
device.
Check the connections
on section 5 or 6
before powering the
device.
1
TOP
BOTTOM
2