ISA Multiview 250 RV TN, Multiview 100 RV TN, Multiview 190 RV TN, Multiview 130 RV TN, Multiview SGD 100 RV TN User manual

...
MULTIVIEW MULTIVIEW
SGD
428000364237 MULTIVIEW
EN
100 130 190 250
Via del Lavoro 5 - 06083 Bastia Umbra PG - Italy
T. +39 075 801 71 - F. +39 075 800 09 00 - E. customerservice@isaitaly.com
www.isaitaly.com
USE AND MAINTENANCE MANUAL
1
1. NOTES / WARNINGS 4
2. MANUFACTURER 10
3. WARRANTY TERMS AND CONDITIONS 10
4. EQUIPMENT IDENTIFICATION 10
5. USE 11
5.1 COMPOSITION 11
6. SAFETY 12
6.1 SAFETY DEVICES PRESENT 12
6.2 FIXED GUARDS 12
6.3 ISOLATING THE ELECTRIC POWER SUPPLY 12
6.4 RESIDUAL RISKS 12
6.5 RISK OF CONTACT WITH LIVE PARTS 12
6.6 FIRE 12
6.7 EXPLOSIVE ATMOSPHERE 13
6.8 SLIPPING 13
6.9 TRIPPING 13
6.10 CIRCUIT FAULTS 13
6.11 WARNING SIGNS (IF ANY) 13
6.12 FALLING OBJECTS 13
6.13 COOLING 13
6.14 FOOD SAFETY (PACKAGED PRODUCTS) 13
7. DISPOSAL OF WASTE MATERIAL 14
8. INSTALLATION 15
8.1 STORAGE AND UNPACKING 15
8.2 ENVIRONMENTAL CONDITIONS 15
8.3 WALL MOUNTING 15
8.4 POSITIONING / MOVING 16
8.5 ELECTRICAL CONNECTION 16
9. MAINTENANCE 17
10. FAULTS - TECHNICAL AFTER-SALES ASSISTANCE 18
10.1 ALARMS LIST (WHERE PRESENT) 19
11. TECHNICAL SPECIFICATIONS 20
11.1 OPEN / CLOSE SELF-ROLLING CURTAIN (MULTIVIEW) 21
11.2 LIGHTING 21
11.3 DISPLAY SHELVES 22
11.4 DISPLAY SHELVES MAX. LOAD 22
12. CONTROL PANEL 23
12.1 USER INTERFACE 24
13. CLEANING 25
13.1 INTERNAL 25
13.2 CONDENSER UNIT (REMOVABLE) 26
13.3 DEFROST WATER COLLECTION TRAY (IF PRESENT) 26
14. PROLONGED APPLIANCE SWITCH-OFF 27
428000364237 MULTIVIEW
EN
USE AND MAINTENANCE MANUAL
2
ATTACHMENTS 1 WIRING DIAGRAM - 412100302000 28 2 WIRING DIAGRAM - 412100303000 29 3 WIRING DIAGRAM - 412100304000 30 4 WIRING DIAGRAM - 412100305100 31 5 WIRING DIAGRAM - 412100306100 32 6 WIRING DIAGRAM - 412100307100 33
The manual contains symbols to attract the reader's attention and highlight particularly important aspects. The table below illustrates the meaning of the various symbols used.
Read the manual Use of protective clothing
DANGER Live electrical parts
ATTENTION / DANGER Important information
Information
Eye check Notes/Important Notes
On-board Condensing unit Remote Condensing unit
DANGER Slipping
DANGER Tripping
Maintenance requirement or operations that must be completed by qualifi ed personnel or technical assistance centre
Operations that must be performed by two persons
Waste disposal
Recyclable Material
Earthing
428000364237 MULTIVIEW
EN
USE AND MAINTENANCE MANUAL
3
1. NOTES / WARNINGS
NOTE
The content of this manual is of technical nature and is owned by ISA. It is forbidden to reproduce, circulate or modify all or part of its content without written consent. Any infringement will be legally pursued.
The manual and the conformity certifi cate are an integral part of the equipment and should always accompany the product in the event of a transfer to a new location or to a new owner. The user is responsible for the integrity of these documents, for their consultation and during the whole life cycle of the equipment itself. Keep this manual in a safe place.It should be available for consultation near the equipment at all times. If lost or destroyed, you can request a copy of the manual from ISA by specifying the exact model, serial number and year of manufacture. The manual refl ects the manufacturing technology at the time of supply.The manufacturer reserves the right to modify its products in any way it deems necessary, with no obligation to update manuals and machines relating to previous manufacturing batches.
The equipment can be used by children no younger than 8 and by persons with reduced physical, sensorial or mental capabilities, or lacking experience or necessary knowledge, as long as supervised or after having received training regarding safe use of the equipment and have an understanding of the inherent risks involved. Do not allow children to play with the device. The cleaning and maintenance that the user will carry out must not be undertaken by children without supervision.
Always refer to this manual before going ahead with any operation. Before doing any type of work, disconnect the equipment from the power supply. Any work on electric and electronic parts or cooling system components should only be carried out by trained personnel in compliance with current laws.
The Manufacturer cannot be held liable for any damage to persons, animals or to the product in the following cases:
• improper use of the equipment or use of the appliance by unqualifi ed or unauthorised personnel;
• failure to comply with current legislation
• incorrect installation and/or power supply faults
• failure to observe the instructions contained in this Manual
• failure to follow the maintenance programme
• unauthorised modifi cations
• installation of non-original spare parts in the equipment
• installation and use of the equipment for purposes other than those for which the appliance was designed and sold;
• Tampering with or damage to the power supply cable.
428000364237 MULTIVIEW
EN
USE AND MAINTENANCE MANUAL
4
1. NOTES / WARNINGS
Liability for applying the safety instructions contained in this manual is held by the technical personnel responsible for the intended use of the equipment, who should ensure that authorised personnel:
• Are qualifi ed to carry out the requested activity;
• is aware of and carefully complies with the instructions contained in this document
• are aware of, and apply, the general safety standards applicable to the equipment.
The buyer is responsible for training personnel using the appliance on the risks, safety devices and general health and safety rules required by the laws of the country where the appliance is installed.Users/operators should be aware of the position of all the controls and how they work, as well as of the features of the appliance. They should also read this manual in its entirely. Maintenance work should be conducted by qualifi ed personnel after the appliance has been prepared adequately.
DANGER
Unauthorised tampering with or replacement of one or more parts of the appliance, use of accessories that modify the use of the same and use of spare parts different to those recommended, can become the cause of injury.
DANGER
Any work conducted on the on the appliance must involve disconnection from the power socket and in any case, none of the protective elements (grid, casing) should be removed by non-qualifi ed staff.The appliance should not be operated when these protective elements have been removed.
NOTE
In order not to compromise functionality and safety of the appliance, the particularly complex installation and maintenance activities are not documented in this manual and are performed by specialised ISA S.r.l. division TASSELLI.
Never use electric devices inside this appliance. Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer. Keep the air vents in the casing of the appliance or in the structure built into the wall free of obstructions. Do not damage the refrigeration circuit.
RISK OF EXPLOSION
Do not store products containing fl ammable propellants or explosives.
428000364237 MULTIVIEW
EN
USE AND MAINTENANCE MANUAL
5
1. NOTES / WARNINGS
STAFF TRAINING
The buyer is responsible for ensuring personnel who will use the appliance and maintenance technical staff are instructed and trained adequately. The manufacturer is available for advice, clarifi cations, etc. so that the operator and technical staff can use the appliance correctly. To ensure operator safety, appliance devices should be kept in constant working order. This manual is intended to illustrate the use and maintenance of the appliance.The operator has a responsibility and duty to carefully observe the instructions contained within it.
Failure to comply with safety standards may result in injury to personnel and damage to the equipment components and control unit. The user can contact the dealer to request additional information not contained in this document, or suggest improvements, at any time.
Before the product is delivered to the customer, it is essential that a trained technical member of staff checks that the appliance is operating correctly in order to achieve maximum performance.
INTRODUCTION ISA employs materials of the best quality and as they enter the company,
we constantly monitor their storage and the use as part of the manufacturing process to prevent damage, deterioration and failure. All manufacturing elements has been designed and manufactured in order to guarantee reliability and high safety standards. All appliances are subjected to a strict testing procedure before delivery .However , please bear in mind that product performance over time depends on correct use and adequate maintenance. This manual contains the necessary instructions to maintain the appliance’s initial appearance and functions over time.
The use and maintenance manual contains the information required to understand the operating modes of the appliance and for its correct use, in particular: the technical description of the various functional groups, accessories and safety systems, operation, use of instrumentation and interpretation of any diagnostic warnings, main procedures and information relating to the ordinary maintenance operations. For correct use of the appliance, the working environment should comply with current health and safety standards.
The safety requirements, indications, standards and notes illustrated in the various chapters of the manual are aimed at establishing a code of conduct and a series of obligations to be observed when performing the various activities, in order to create safe conditions for personnel, the equipment and the surrounding environment.
428000364237 MULTIVIEW
EN
USE AND MAINTENANCE MANUAL
6
1. NOTES / WARNINGS
The safety standards reported in this document are intended for trained, authorised personnel responsible for:
• Transport
• Installation
• Operation
• Management
• Maintenance
• Cleaning
• Putting out of order
• Disposal
ATTENTION
Reading this manual, albeit in full, is no substitute for adequate user experience. therefore it should only be considered a useful reminder of the technical features and the main operations to perform.
WARNING
Installers and users must read and understand all instructions herein before carrying out any operation on the equipment.
428000364237 MULTIVIEW
EN
USE AND MAINTENANCE MANUAL
7
1. NOTES / WARNINGS
R744 - REFRIGERANT (WHERE APPLICABLE)
R744 The refrigerant R744 is a gas that is compatible with the environment.
Pay close attention during transport, installation and that the destruction not to damage the refrigerant pipelines.
IN THE EVENT OF DAMAGE:
Keep fl ames or sources of ignition away from the appliance. Properly ventilate the premises for a few minutes. Turn the unit off, pull the plug. Notify the customer service department.
ATTENTION
The refrigerant system is High Pressure.
Do not tamper with the system, but call a specialised and qualifi ed technician before disassembly.
ATTENTION
Maintenance must be performed by qualifi ed personnel that has been to work with fl ammable refrigerants.
R290 - REFRIGERANT (WHERE APPLICABLE)
The refrigerant R290 is a gas that is compatible with the environment, but is highly in ammable. Pay close attention during transport, installation and dismantling not to damage the refrigerant pipelines.
IN THE EVENT OF DAMAGE:
Keep fl ames or sources of ignition away from the appliance. Properly ventilate the premises for a few minutes. Turn the unit off, pull the plug. Notify the customer service department. The more refrigerant containing an appliance, the greater must be the environment in which there is the unit. In areas too small, in the event of leakage can form a fl ammable mixture of air and gas. The volume of
the room where the appliance is installed must be at least 19 m³ for each cooling system present in the room.
428000364237 MULTIVIEW
EN
ATTENTION
Maintenance must be performed by qualifi ed technical personnel with ap- propriate training and authorisation to work with infl ammable refrigerants.
USE AND MAINTENANCE MANUAL
8
1. NOTES / WARNINGS
R600a - REFRIGERANT (WHERE APPLICABLE)
The refrigerant R600a is a gas that is compatible with the environment, but highly ammable. Pay close attention during transport, installation and dismantling not to damage the refrigerant pipelines.
IN THE EVENT OF DAMAGE:
Keep fl ames or sources of ignition away from the appliance. Properly ventilate the premises for a few minutes. Turn the unit off, pull the plug. Notify the customer service department. The more refrigerant containing an appliance, the greater must be the environment in which there is the unit. In areas too small, in the event of leakage can form a fl ammable mixture of air and gas. The volume of
the room where the appliance is installed must be at least 17 m³ for each cooling system present in the room.
ATTENTION
Maintenance must be performed by qualifi ed technical personnel with ap- propriate training and authorisation to work with infl ammable refrigerants.
428000364237 MULTIVIEW
EN
USE AND MAINTENANCE MANUAL
9
2. MANUFACTURER
ISA
Bastia Umbra - Perugia - Italy
www.isaitaly.com
Tel. +39 075 80171 Fax ++39 075 8000900
3. WARRANTY TERMS AND CONDITIONS
The seller's warranty on the equipment is valid for 12 (TWELVE) months from the date of delivery. The warranty includes repairs or replacements of any faulty parts due to manufacturing processes or installation after written communication has been received, stating the appliance serial number and date of installation. Not included in the warranty:
• Incorrect use of the appliance
• Incorrect connection to the power grid
• Normal component wear (e.g. compressor failure, neon/LED lights, etc.) where not caused by manufacturing defects.
• Installation, technical instruction, regulation and condenser cleaning call-outs. If the seller's technical staff detect any tampering, unauthorised repairs or inappropriate use of appliance the warranty
will be invalidated. Shipment of components covered by the warranty is freight collect only. Any damage to the appliance detected at the time of delivery due to transport must be reported on the same shipping note to claim compensation from the carrier. The seller cannot be held liable in the event of damage to accepted products due to appliance faults.
4. EQUIPMENT IDENTIFICATION
• Find the label affi xed to the machine in order to read technical data.
• Check the machine model and the power supply voltage before you perform any operation.
• If you fi nd discrepancies, contact the manufacturer or the company that supplied the machine immediately.
1
IDENTIFICATION OF THE COMPANY RESPONSIBLE FOR THE PRODUCT 2 SYMBOLS OF COMPLIANCE 3 TYPE 4 MODEL NAME 5 ARTICLE 6 PRODUCTION DATE 7 PRODUCTION ORDER 8 CUSTOMER ORDER 9 PRODUCT CLASS 10 SERIAL NO. 11 OWNER REGISTRATION NUMBER 12 SUPPLY VOLTAGE 13 SUPPLY VOLTAGE 14 FUSE VALUE 15 LAMP POWER 16 ELECTRICAL RESISTANCE ABSORPTION 17 NOMINAL POWER (NORMAL OPERATION) 18 POWER (DEFROSTING) 19 MINIMUM PRESSURE 20 MAXIMUM PRESSURE 21 SAFETY CLASS 22 NOMINAL CURRENT 23 CURRENT DURING DEFROSTING 24 SHELF LOAD 25 TANK LOAD 26 TYPE OF COOLANT 27 WEIGHT OF COOLANT 28 GROSS VOLUME 29 EXPANDING ISOLATION AGENT 30 WEEE MARK
428000364237 MULTIVIEW
EN
USE AND MAINTENANCE MANUAL
10
5. USE
This appliance is exclusively intended to:
DISPLAY OF FRESH PRE-PACKAGED, DAIRY AND DRINK PRODUCTS
The manufacturer is not liable for injury to persons or damage to property or the appliance itself caused by the displaying of products other than those described above.
THE APPLIANCE IS INTENDED FOR PROFESSIONAL USE.
Not suitable for:
• Food preservation.
Displaying and/or preserving non-food products (chemicals, pharmaceuticals, etc...).
ATTENTION
LOAD LIMITS
It is fundamental not to exceed the load limits indicated in order not to alter the correct air circulation and thus prevent a higher product temperature. The limits indicated refer to a static and evenly distributed load. Therefore dynamic overloads due to violent loading operations are excluded, which must be prevented for safety reasons.
5.1 COMPOSITION
The appliance is made up from a unique cabinet, onto which all devices necessary to make it a professional and effi cient product for its declared use, are installed.
The appliance is composed of:
Ventilated refrigeration unit (VR) Condensing unit on board (UCB) or remote (UCR) Electrical system Electronic controller Insulated monolithic structure in ecological polyurethane Height-adjustable feet Internal LED illumination Height-adjustable display shelves Front closing with manual self-rolling cover MULTIVIEW Front closing with single glass doors MULTIVIEW SGD Automatic condensed water evaporation Only UCA models
428000364237 MULTIVIEW
EN
USE AND MAINTENANCE MANUAL
11
Loading...
+ 23 hidden pages