Via Madonna di Campagna 123 - 06083 Bastia Umbra PG - Italy
T. +39 075 801 71 - F. +39 075 800 09 00 - E. customerservice@isaitaly.com
www.isaitaly.com
USE AND MAINTENANCE MANUAL
1
1.NOTES / WARNINGS4
2.MANUFACTURER10
3.WARRANTY TERMS AND CONDITIONS10
4.EQUIPMENT IDENTIFICATION10
5.USE11
5.1COMPOSITION11
6.SAFETY12
6.1SAFETY DEVICES PRESENT12
6.2FIXED GUARDS12
6.3ISOLATING THE ELECTRIC POWER SUPPLY12
6.4RESIDUAL RISKS12
6.5RISK OF CONTACT WITH LIVE PARTS12
6.6FIRE12
6.7EXPLOSIVE ATMOSPHERE13
6.8SLIPPING13
6.9TRIPPING13
6.10CIRCUIT FAULTS13
6.11WARNING SIGNS (IF ANY)13
6.12FALLING OBJECTS13
6.13COOLING13
6.14FOOD SAFETY (PACKAGED PRODUCTS)13
7.DISPOSAL OF WASTE MATERIAL14
8.INSTALLATION15
8.1STORAGE AND UNPACKING15
8.2ENVIRONMENTAL CONDITIONS15
8.3ELECTRICAL CONNECTION15
8.4WALL MOUNTING/LEVELLING16
8.5POSITIONING / MOVING17
9.MAINTENANCE18
10.FAULTS - TECHNICAL AFTER-SALES ASSISTANCE19
10.1ALARMS LIST (WHERE PRESENT)20
11.TECHNICAL SPECIFICATIONS21
11.1TECHNICAL PLANS22
11.2LIGHTING23
11.3WEIGHTS ON SHELF23
11.4GLASS FRONT OPENING23
11.5OPERATOR SIDE OPENING / CLOSING24
12.CONTROL PANEL25
12.1USER INTERFACE EW974 LVD27
12.2USER INTERFACE XR44CH28
13.CLEANING 31
13.1INTERNAL31
13.2CONDENSING UNIT32
13.2.1FILTER (IF PRESENT)32
13.3DEFROST WATER COLLECTION TRAY (IF PRESENT)32
14.PROLONGED APPLIANCE SWITCH-OFF 33
428000467237 MILLENNIUM
EN
USE AND MAINTENANCE MANUAL
2
ATTACHMENTS
1WIRING DIAGRAM - 41210054010034
2WIRING DIAGRAM - 41210054110036
3WIRING DIAGRAM - 41210061700038
4WIRING DIAGRAM - 41210061800040
5WIRING DIAGRAM - 41210061900042
6WIRING DIAGRAM - 41210062100044
7WIRING DIAGRAM - 41210062200046
8WIRING DIAGRAM - 41210062300048
9WIRING DIAGRAM - 41210062400050
10WIRING DIAGRAM - 41210062000052
11WIRING DIAGRAM - 41210075230054
12WIRING DIAGRAM - 41210087910056
13WIRING DIAGRAM - 41210090000058
The manual contains symbols to attract the reader's attention and highlight particularly
important aspects. The table below illustrates the meaning of the various symbols used.
Read the manualUse of protective clothing
DANGER
Live electrical parts
ATTENTION / DANGERImportant information
Information
Eye checkNotes/Important Notes
DANGER
Slipping
DANGER
Tripping
Earthing
Maintenance requirement or operations that
must be completed by qualied personnel or
technical assistance centre
Operations that must be performed by two
persons
Waste disposal
Recyclable Material
428000467237 MILLENNIUM
EN
USE AND MAINTENANCE MANUAL
3
1. NOTES / WARNINGS
NOTE
The content of this manual is of technical nature and is owned by ISA.
It is forbidden to reproduce, circulate or modify all or part of its content
without written consent. Any infringement will be legally pursued.
The manual and the conformity certicate are an integral part of the equipment
and should always accompany the product in the event of a transfer to a new
location or to a new owner. The user is responsible for the integrity of these
documents, for their consultation and during the whole life cycle of the equipment
itself. Keep this manual in a safe place.It should be available for consultation
near the equipment at all times. If lost or destroyed, you can request a copy of
the manual from ISA by specifying the exact model, serial number and year of
manufacture. The manual reects the manufacturing technology at the time of
supply.The manufacturer reserves the right to modify its products in any way it
deems necessary, with no obligation to update manuals and machines relating to
previous manufacturing batches.
The equipment can be used by children no younger than 8 and by persons
with reduced physical, sensory or mental capabilities, or lacking experience or
necessary knowledge, as long as supervised or after having received training
regarding safe use of the equipment and have an understanding of the inherent
risks involved. Do not allow children to play with the device. The cleaning and
maintenance that the user will carry out must not be undertaken by children
without supervision.
Always refer to this manual before going ahead with any operation. Before doing
any type of work, disconnect the equipment from the power supply. Any work on
electric and electronic parts or cooling system components should only be carried
out by trained personnel in compliance with current laws.
The Manufacturer cannot be held liable for any damage to persons, animals or to
the product in the following cases:
• improper use of the equipment or use of the appliance by unqualied or
unauthorised personnel;
• failure to comply with current legislation
• incorrect installation and/or power supply faults
• failure to observe the instructions contained in this Manual
• failure to follow the maintenance programme.
• unauthorised modications
• installation of non-original spare parts in the equipment
• installation and use of the equipment for purposes other than those for which
the appliance was designed and sold;
• Tampering with or damage to the power supply cable.
428000467237 MILLENNIUM
EN
USE AND MAINTENANCE MANUAL
4
1. NOTES / WARNINGS
Liability for applying the safety instructions contained in this manual is held by
the technical personnel responsible for the intended use of the equipment, who
should ensure that authorised personnel:
• Are qualied to carry out the requested activity;
• is aware of and carefully complies with the instructions contained in this
document
• are aware of, and apply, the general safety standards applicable to the
equipment.
The buyer is responsible for training personnel using the appliance on the risks,
safety devices and general health and safety rules required by the laws of the
country where the appliance is installed.Users/operators should be aware of the
position of all the controls and how they work, as well as of the features of the
appliance.
They should also read this manual in its entirely. Maintenance work should be
conducted by qualied personnel after the appliance has been prepared adequately.
DANGER
Unauthorised tampering with or replacement of one or more parts
of the appliance, use of accessories that modify the use of the same
and use of spare parts different to those recommended, can become
the cause of injury.
DANGER
Any work conducted on the on the appliance must involve
disconnection from the power socket and in any case, none of the
protective elements (grid, casing) should be removed by non-qualied
staff.The appliance should not be operated when these protective
elements have been removed.
NOTE
In order not to compromise functionality and safety of the appliance,
the particularly complex installation and maintenance activities are
not documented in this manual and are performed by the writing
company.
Never use electric devices inside this appliance. Do not use mechanical
devices or other means to accelerate the defrosting process, other than those
recommended by the manufacturer. Keep the air vents in the casing of the
appliance or in the structure built into the wall free of obstructions. Do not
damage the refrigeration circuit.
RISK OF EXPLOSION
Do not store products containing ammable propellants or explosives.
428000467237 MILLENNIUM
EN
USE AND MAINTENANCE MANUAL
5
1. NOTES / WARNINGS
STAFF TRAINING
The buyer is responsible for ensuring personnel who will use the appliance
and maintenance technical staff are instructed and trained adequately. The
manufacturer is available for advice, clarications, etc. so that the operator
and technical staff can use the appliance correctly. To ensure operator safety,
appliance devices should be kept in constant working order. This manual is
intended to illustrate the use and maintenance of the appliance.The operator has
a responsibility and duty to carefully observe the instructions contained within it.
Failure to comply with safety standards may result in injury to personnel and
damage to the equipment components and control unit.
The user can contact the dealer to request additional information not contained
in this document, or suggest improvements, at any time.
Before the product is delivered to the customer, it is essential that
a trained technical member of staff checks that the appliance is
operating correctly in order to achieve maximum performance.
INTRODUCTION
ISA employs materials of the best quality and as they enter the company,
we constantly monitor their storage and the use as part of the manufacturing
process to prevent damage, deterioration and failure. All manufacturing elements
has been designed and manufactured in order to guarantee reliability and high
safety standards. All appliances are subjected to a strict testing procedure before
delivery.However, please bear in mind that product performance over time depends
on correct use and adequate maintenance. This manual contains the necessary
instructions to maintain the appliance’s initial appearance and functions over
time.
The use and maintenance manual contains the information required to understand
the operating modes of the appliance and for its correct use, in particular: the
technical description of the various functional groups, accessories and safety
systems, operation, use of instrumentation and interpretation of any diagnostic
warnings, main procedures and information relating to the ordinary maintenance
operations. For correct use of the appliance, the working environment should
comply with current health and safety standards.
The safety requirements, indications, standards and notes illustrated in the
various chapters of the manual are aimed at establishing a code of conduct and
a series of obligations to be observed when performing the various activities, in
order to create safe conditions for personnel, the equipment and the surrounding
environment.
428000467237 MILLENNIUM
EN
USE AND MAINTENANCE MANUAL
6
1. NOTES / WARNINGS
The safety standards reported in this document are intended for trained, authorised
personnel responsible for:
• Transport
• Installation
• Operation
• Management
• Maintenance
• Cleaning
• Putting out of order
• Disposal
ATTENTION
Reading this manual, albeit in full, is no substitute for adequate user
experience. therefore it should only be considered a useful reminder
of the technical features and the main operations to perform.
WARNING
Installers and users must read
and understand all instructions herein before
carrying out any operation on the equipment.
428000467237 MILLENNIUM
EN
USE AND MAINTENANCE MANUAL
7
1. NOTES / WARNINGS
R744 - REFRIGERANT (WHERE APPLICABLE)
R744 The refrigerant R744 is a gas that is compatible with the environment.
Pay close attention during transport, installation and that the
destruction not to damage the refrigerant pipelines.
IN THE EVENT OF DAMAGE:
Keep ames or sources of ignition away from the appliance. Properly ventilate
the premises for a few minutes. Turn the unit off, pull the plug. Notify the
customer service department.
ATTENTION
The refrigerant system is High Pressure.
Do not tamper with the system, but call a specialised and qualied technician
before disassembly.
ATTENTION
Maintenance must be performed by qualied personnel that has been
to work with ammable refrigerants.
R290 - REFRIGERANT (WHERE APPLICABLE)
The refrigerant R290 is a gas that is compatible with the environment,
but is highly ammable. Pay close attention during transport,
installation and dismantling not to damage the refrigerant pipelines.
IN THE EVENT OF DAMAGE:
Keep ames or sources of ignition away from the appliance. Properly ventilate the
premises for a few minutes. Turn the unit off, pull the plug. Notify the customer
service department. The more refrigerant containing an appliance, the greater
must be the environment in which there is the unit. In areas too small, in the
event of leakage can form a ammable mixture of air and gas. The volume of
the room where the appliance is installed must be at least 19 m³ for each
cooling system present in the room.
428000467237 MILLENNIUM
EN
ATTENTION
Maintenance must be performed by qualied technical personnel
with appropriate training and authorisation to work with inammable
refrigerants.
USE AND MAINTENANCE MANUAL
8
1. NOTES / WARNINGS
R600a - REFRIGERANT (WHERE APPLICABLE)
The refrigerant R600a is a gas that is compatible with the
environment, but highly ammable. Pay close attention during
transport, installation and dismantling not to damage the refrigerant
pipelines.
IN THE EVENT OF DAMAGE:
Keep ames or sources of ignition away from the appliance. Properly ventilate the
premises for a few minutes. Turn the unit off, pull the plug. Notify the customer
service department. The more refrigerant containing an appliance, the greater
must be the environment in which there is the unit. In areas too small, in the
event of leakage can form a ammable mixture of air and gas. The volume of
the room where the appliance is installed must be at least 17 m³ for each
cooling system present in the room.
ATTENTION
Maintenance must be performed by qualied technical personnel
with appropriate training and authorisation to work with inammable
refrigerants.
428000467237 MILLENNIUM
EN
USE AND MAINTENANCE MANUAL
9
2. MANUFACTURER
ISA S.p.A.
Via Madonna di Campagna 123
06083 Bastia Umbra PG
Italy
T. +39 075 801 71
F. +39 075 800 09 00
E. customerservice@isaitaly.com
www.isaitaly.com
3. WARRANTY TERMS AND CONDITIONS
The seller's warranty on the equipment is valid for 12 (TWELVE) months from the date of delivery.
The warranty includes repairs or replacements of any faulty parts due to manufacturing processes or installation after
written communication has been received, stating the appliance serial number and date of installation.
Not included in the warranty:
• Incorrect use of the appliance
• Incorrect connection to the power grid
• Normal component wear (e.g. compressor failure, neon/LED lights, etc.) where not caused by manufacturing defects.
• Installation, technical instruction, regulation and condenser cleaning call-outs.
If the seller's technical staff detect any tampering, unauthorised repairs or inappropriate use of appliance the warranty
will be invalidated.
Shipment of components covered by the warranty is freight collect only.
Any damage to the appliance detected at the time of delivery due to transport must be reported on the same shipping
note to claim compensation from the carrier.
The seller cannot be held liable in the event of damage to accepted products due to appliance faults.
4. EQUIPMENT IDENTIFICATION
• Find the label afxed to the machine in order to read technical data.
• Check the machine model and the power supply voltage before you perform any operation.
• If you nd discrepancies, contact the manufacturer or the company that supplied the machine immediately.
1
IDENTIFICATION OF THE COMPANY RESPONSIBLE FOR THE PRODUCT
2SYMBOLS OF COMPLIANCE
3TYPE
4MODEL NAME
5ARTICLE
6PRODUCTION DATE
7PRODUCTION ORDER
8CUSTOMER ORDER
9PRODUCT CLASS
10SERIAL NO.
11OWNER REGISTRATION NUMBER
12SUPPLY VOLTAGE
13SUPPLY VOLTAGE
14FUSE VALUE
15LAMP POWER
16ELECTRICAL RESISTANCE ABSORPTION
17NOMINAL POWER (NORMAL OPERATION)
18POWER (DEFROSTING)
19MINIMUM PRESSURE
20
MAXIMUM PRESSURE
21SAFETY CLASS
22NOMINAL CURRENT
23CURRENT DURING DEFROSTING
24SHELF LOAD
25TANK LOAD
26TYPE OF COOLANT
27WEIGHT OF COOLANT
28GROSS VOLUME
29EXPANDING ISOLATION AGENT
WEEE MARK
30
428000467237 MILLENNIUM
EN
USE AND MAINTENANCE MANUAL
10
5. USE
This appliance is exclusively intended to:
DISPLAYING AND SALE OF SPREADABLE ICE CREAM
The manufacturer is not liable for injury to persons or damage to property or the appliance itself caused by
the displaying of products other than those described above.
It is fundamental not to exceedthe load limits indicated in order not to alter the correct air circulation
and thus prevent a higher product temperature. The limits indicated refer to a static and evenly distributed
load. Therefore dynamic overloads due to violent loading operations are excluded, which must be
prevented for safety reasons.
5.1 COMPOSITION
The appliance is made up from a unique cabinet, onto which all devices necessary to make it a professional and efcient
product for its declared use, are installed.
The appliance is composed of:
Ventilated refrigeration unit
On board or remote condensing units
Electrical system
Electronic command panel
Insulated monolithic structure in ecological polyurethane
Internal LED lighting
Closure on operator side with manual self-winding / sliding blind
Front glass opened manuallyLX
Front glass tilted manuallyST - JX
Swivel casters with brakes
Height adjustable feet
428000467237 MILLENNIUM
EN
USE AND MAINTENANCE MANUAL
11
6. SAFETY
The appliance is equipped with safety devices. The buyer is responsible for training personnel using the appliance on the
risks, safety devices and general health and safety rules required by the laws of the country where the appliance is installed. Users/operators should be aware of the position of all the controls and how they work, as well as of the features
of the appliance. They must also have read this manual in its entirety.
6.1 SAFETY DEVICES PRESENT
Devices whose operation prevents the occurrence of risk situations in operating conditions (e.g. fuses, pressure
switches, protections, magnet circuit breakers, etc.).
6.2 FIXED PROTECTIONS
Fixed protective devices consist of xed perimeter shields, which are used to prevent external parts from entering the
equipment.
DANGER
The appliance must not be restarted following maintenance until all protective panels have been replaced.
VISUAL OBSERVATION
You should check the integrity of xed panels and corresponding xings to the frame, focussing in
particular on the protective panels.
6.3 ISOLATING THE ELECTRIC POWER SUPPLY
Before conducting any maintenance work on the equipment or part of it, it is necessary to section the power supply that
powers it.
DANGER
In the event of maintenance operations in which the operator cannot prevent accidental closure of the
circuit by others, disconnect the appliance from the mains electricity entirely.
6.4 RESIDUAL RISKS
During design the manufacturer examined all the areas or parts at risk.Therefore, all necessary precautions have been
taken to prevent risks to persons and damage to the appliance.
ATTENTION
• Periodically check that all safety devices are operating correctly.
• Do not remove the xed guards.
• Do not introduce objects or tools into the work area.
Although the appliance is tted with the safety devices prepared, there are still some risks that cannot be eliminated,
Below is a summary of the remaining risks associated with the appliance during:
• Normal operation
• Adjustments and ne tuning
• Maintenance
• Cleaning
but reduced via corrective action by the nal integrator and correct operational procedures.
6.5 RISKS OF CONTACT WITH LIVE PARTS
following a short circuit.
Before connecting the electricity supply, make sure there is no ongoing maintenance work.
Risk of breaking or damaging the electrical components of the appliance, with a possible reduction in safety levels
6.6 FIRE
428000467237 MILLENNIUM
EN
ATTENTION
Before making the connection, check that the d.c. current in the installation point does not exceed that
indicated on the protections switches present in the electric control board.If this is not the case, the user
must envision the relevant limiting devices. It is strictly forbidden to conduct any electrical modication, in
order to prevent additional unforeseen hazards and risks.
DANGER
In the event of a re, immediately disconnect the master switch from the main power supply line.
USE AND MAINTENANCE MANUAL
12
6.7 EXPLOSIVE ATMOSPHERE
The equipment must not be located in an area classied as an explosion risk
as per 199/92/EC such as:
Zone 0
An area in which there is a permanent, long-lasting or frequently explosive atmosphere made up of a mixture of air and
ammable substances in the form of gases, fumes or steam.
Zone 1
An area in which the formation of an explosive atmosphere, made up of a mixture of air and ammable substances in
the form of gases, fumes or steam is occasionally probable during normal activities.
Zone 20
An area in which there is a permanent, long-lasting or frequently explosive atmosphere in the form of clouds of
combustible dust in the air.
Zone 21
An area in which the formation of an explosive atmosphere in the form of clouds of combustible dust is occasionally
probable during normal activities.
6.8 SLIPPING
DANGER
Any leaks in the areas surrounding the appliance may cause personnel to slip. Check that there are
no leaks and keep these areas clean at all times.
6.9 TRIPPING
DANGER
Generally untidy deposits of material may constitute a trip hazard and a total or partial obstruction
of emergency exit routes. You should ensure that operating and transit areas and escape routes are
free from obstacles in compliance with current law.
6.10 CIRCUIT FAULTS
Owing to potential faults, safety circuits may become less effective, which results in lower safety levels. You should
check the operational condition of the appliance devices regularly.
6.11 WARNING SIGNS(IF ANY)
The appliance is tted with warning danger, warning and obligation signs dened in agreement with the Standard relative to
the graphical signs to be used on equipment. These signs are located where they are clearly visible.
ATTENTION
Any warning plates on the appliance must not be removed.
The user is responsible for replacing warning signs that, owing to wear, become unreadable.
6.12 FALLING OBJECTS
The positioning of the cabinet display parts (where present) of the equipment (i.e. counters, rods and hooks, etc.),
as well as the arrangement of the products inside the cabinet can be the source of potential hazards if not properly
performed. Follow the positioning instructions described in this Manual before you place products inside the cabinet,
check that the counters are properly fastened, as also the hooks, etc. Do not exceed the maximum load limit. Do not
exceed the maximum load limit. Do not position tilted product on the counters if they are not held in place by their
stoppers.
6.13 COLD
During different operations to perform on the counter, such as cleaning or loading goods, it is necessary to handle
products and/or counter parts at a low temperature with the risk of “cold injury” for the operators and/or accidental
slipping hazard. Follow the safety regulations in the place where the cabinet is installed; more specically, be sure to
always use correct PPE (especially gloves).
6.14 FOODSTUFFS SAFETY(PACKAGED PRODUCTS)
The refrigerator cabinet described herein is meant to be used to display packaged products. As such, it is not designed
for direct contact between the foodstuffs and display surfaces. If the foodstuffs do accidentally make contact with the
surfaces and for a rather long time, the product may be contaminated. Follow the guidelines on how to use the cabinet.
If a product package breaks, remove it from the cabinet and clean, if necessary.
428000467237 MILLENNIUM
EN
USE AND MAINTENANCE MANUAL
13
7. DISPOSAL OF WASTE MATERIAL
During normal operation, the appliance does not generate any environmental contamination. At the end of its life cycle,
or if it is necessary to carry out permanent decommissioning, we recommend the following procedures:
DISPOSAL (USER)
The symbol, applied to either the product or its packaging, indicates that the product should not be
considered as normal domestic waste, but should be taken to a waste collection point for the recycling
of electrical and electronic appliances. The correct disposal of this product contributes to preventing
potential negative consequences that might derive from an inadequate disposal of the product. For detailed
information about recycling this product, contact your council, your local waste collection service or the
store where you purchased the product.
PROCEDURE FOR DISPOSAL and RECYCLING AT THE END OF APPLIANCE LIFE SPAN
OF THE EQUIPMENT (AUTHORISED BODIES)
• Switch off the equipment and unplug the power supply cable.
• Remove the lamps (if installed).These should be disposed of separately.
• Remove the power units and the electronic cards.These should be disposed of separately.
• Remove all the independent parts (grids, casings, proles, etc.) and group them according to shared features in
order to access the heat exchangers, pipes, cables, etc. and be careful not to damage the cooling circuit.
• Remove all mobile parts (doors, sliding doors, glass parts, etc.) and group the various materials according to their
features.
• Check the type of refrigerant on the plate positioned inside the counter; extract the refrigerant and dispose of it
through authorised services.
• Disconnect the evaporator, condenser, compressor, pipes and fans. These are made of copper, aluminium, steel and
plastic and should therefore disposed of separately.
• On removal of all guards and the various components from the frame, separate the different types of material
making up the appliance (plastic, sheet steel, polyurethane, copper, etc.) and collect them separately.
All recyclable materials and waste should be processed and recycled by professionals, in compliance
with the laws in the country in question. The company responsible for recycling the materials should be
registered and certied as a waste disposal service in accordance with the country in question.
ATTENTION
Illegal disposal of the product by the owner will result in administrative sanctions
as required by current laws. Disposal of the product should comply with current laws on the disposal of coolant liquids and mineral oils.
IMPORTANT
If the crossed wheelie bin sign is not present on the appliance, it means that the disposal of the product is
not the manufacturer's responsibility. In these cases, current waste disposal regulations apply. Refer to the
local authorities, waste disposal services or the store from where the product was purchased.
ADDITIONAL INFORMATION
Further information on the disposal of liquid coolant, oils and other substances is available on the safety
data sheet corresponding to the substance itself. In order to dispose of foamed assemblies, remember that
the polyurethane foams used are CFC, HFC and HCFC free.
428000467237 MILLENNIUM
EN
USE AND MAINTENANCE MANUAL
14
8. INSTALLATION
This manual supplies the information necessary for correct unpacking, procedures for
positioning and connection to mains electricity.
8.1 STORAGE and UNPACKING
The appliance, with or without the packaging, should be carefully stored inside warehouses or in areas away from the
elements and direct sunlight, at a temperature between 0 and +40 °C.
MAX
MIN
The movement of the apparatus should only be carried out using a pump or forked truck
of a sufcient capacity for the weight, and moved by qualied personnel: during such operations,
the apparatus must be positioned on the pallet supplied.
8.2 ENVIRONMENTAL CONDITIONS
All packaging materials are recyclable and should be disposed of in accordance with local regulations. All packaging
materials are recyclable and should be disposed of in accordance with local regulations.Please destroy "plastic" bags to
prevent them from becoming hazardous to children (suffocation).
ATTENTION
A dry room that can be ventilated is the suitable location for the appliance's installation. There should be
a good air ow around the compressor/condensing unit.Therefore the area around the unit should not be
obstructed by boxes or other objects. Place the equipment away from sources of heat (radiators, heaters
of any kind, etc.)and far from the inuence of continuous air movement (caused by fans, air conditioning
units, etc.). If it is unavoidable to install near a heat source, use a suitable insulating plate. Also avoid
exposure to direct sunlight; all of this causes the temperature inside the refrigerated compartment to rise
with negative consequences on operation and energy consumption. The apparatus must not be used outside
nor be exposed to rain.
8.3 ELECTRICAL CONNECTION
ATTENTION
Check that the network voltage matches the one displayed on the identication
plate of the appliance, and that the power is adequate. Check on the socket that the power supply voltage
provides rated voltage (±10%) when you start up the compressor. The plug should be directly connected to
the electrical socket.It is forbidden to connect the plug to the socket by means of multiple socket extensions
or adaptors. The plant power supply socket must be tted with a disconnection device from the mains
electricity (dimensioned to the load and in compliance with Standards in force), which guarantees complete
disconnection in category III (3) over-voltage conditions and therefore protects the circuits against earth
faults, overloads and short circuits. Do not route the electricity cable in passageways.
ATTENTION
428000467237 MILLENNIUM
EN
Earthing is necessary and mandatory by law.
USE AND MAINTENANCE MANUAL
15
8.4 WALL MOUNTING/LEVELLING
ATTENTION
It is fundamental to respect the distances indicated (mm) for correct installation of the appliance.
428000467237 MILLENNIUM
EN
USE AND MAINTENANCE MANUAL
16
8.5 POSITIONING / HANDLING
ATTENTION
ADJUSTABLE FEET
The equipment is tted with height-adjustable feet for stabilisation on the ground.
After positioning it is necessary to level the appliance manually on the ground.
ATTENTION
SWIVEL CASTERS (OPTIONAL)
The appliance can be equipped with swivel casters with brakes to facilitate handling.
After positioning it, the appliance must be stabilised on the ground by acting on the specic height
adjustable feet as indicated so that the weight does not weigh on the wheels.
428000467237 MILLENNIUM
EN
USE AND MAINTENANCE MANUAL
17
9. MAINTENANCE
The Staff in charge of the appliance must control and respect the expiry dates for maintenance, given in the table
below, contacting the authorised Technical After-sales assistance when indicated.
OPERATIONFREQUENCY
Depending on the
Use and Necessity
Monthly
Every 6 months
CLEANING THE EXTERNAL SURFACES
CLEANING THE ACCESSIBLE INTERNAL PARTS
(without the use of tools)
CONTROL POWER SUPPLY CABLE,
PLUGS AND / OR ELECTRICAL SOCKETS
INTEGRITY CONTROL SEAL
FILTER CLEANING CONDENSING UNIT
(whenever present)
CLEANING THE DEFROSTING WATER COLLECTION TRAY
CONDENSER CLEANING
CHECK COMPRESSOR OIL LEVEL
(whenever present)
XX
XX
XX
XX
XX
XX
XXX
Annual
PERSONNEL
AUTHORISED
ORDINARY
EXTRAORDINARY
USER
TECHNICAL
ASSISTANCE
X
AIR TANK DRAINING
(whenever present)
CONTROL PNEUMATIC CONNECTIONS
(whenever present)
INTEGRITY CONTROL PIPE COOLING SYSTEM
INSPECTION OF CABLES
INTERNAL CONNECTIONS AND POWER
CLEANING CONDENSATE DRYING SPONGES
(whenever present)
LAMP / LED REPLACEMENT
(whenever present)
CONTROL PANEL REPLACING
(electronic control unit - thermostat - etc.)
REPLACEMENT POWER SUPPLY CABLE, PLUGS AND / OR ELECTRICAL SOCKETS
ATTENTION
After all maintenance it is mandatory to perform all electrical safety tests in accordance with
the IEC EN 50106 Standard.
XX
XX
XX
XX
XX
X
X
X
428000467237 MILLENNIUM
EN
USE AND MAINTENANCE MANUAL
18
Loading...
+ 42 hidden pages
You need points to download manuals.
1 point = 1 manual.