Single 1 In, 8 Out / Dual 1 In, 4 Out 3G/HD/SD/ASI Reclocking/Non-Reclocking Distribution Amplifier
User Manual
IRT Electr
onics
Pty Ltd | www.irtelectr
Page 1 of 21
onics.co
m
Revision 01
DDA-4010
Single 1 In, 8 Out / Dual 1 In, 4 Out 3G/HD/SD/ASI Reclocking/Non-Reclocking Distribution Amplifier
Revision History:
Revision Date By Change Description Applicable to:
00 03/01/2013 AL Original Issue.
01 03/06/2013 AL DIP switch designators changed to SW1 and SW2,
links LK1 and LK2 added for rear assembly alarm
output NO/NC operation, front panel monitor BNC
outputs slew rate matches that of individual inputs
as opposed to current output.
Issue 3 PCB units
fitted with
firmware version ≥ 2.1
Issue 4 PCB units
fitted with
firmware version ≥ 2.1
IRT Electr
onics
Pty Ltd | www.irtelectr
Page 2 of 21
onics.co
m
Revision 01
USER MANUAL
Table of Contents:
This instruction book applies to Issue 4 PCB units fitted with firmware version ≥ 2.1
DDA-4010
Section Page
Revision History 2
Operational Safety 4
General Description 5
Technical Specifications 6
Configuration 7
DDA-4010 DIP Switch Settings 7
DDA-4010 Alarm Link Settings 8
Single 1 In, 8 Out Quick Set-up Guide 8
Dual 1 In, 4 Out Quick Set-up Guide 9
Installation 10
Signal Inputs & Outputs 10
Alarm Outputs 11
Front and Rear Layouts 12
Operation 13
Single 1 In, 8 Out Mode 13
ChAx8: Input A to all 8 Outputs 13
ChBx8: Input B to all 8 Outputs 13
Automatic Changeover Mode 13
Non-Reclocking Mode 14
Front Panel Monitor Outputs 14
Relay Bypass Option 14
Dual 1 In, 4 Out Mode 15
Input A to 4 Output A, and Input B to 4 x Output B 15
Automatic Changeover Mode 15
Non-Reclocking Mode 16
Front Panel Monitor Outputs 16
Relay Bypass Option 16
Operation of electronic equipment involves the use of voltages and currents that
may be dangerous to human life. Note that under certain conditions dangerous
potentials may exist in some circuits when power controls are in the OFF position.
Maintenance personnel should observe all safety regulations.
Do not make any adjustments inside equipment with power ON unless proper
precautions are observed. All internal adjustments should only be made by suitably
qualified personnel. All operational adjustments are available externally without
the need for removing covers or use of extender cards.
DDA-4010
WARNING
IRT Electr
onics
Pty Ltd | www.irtelectr
Page 4 of 21
onics.co
m
Revision 01
GENERAL DESCRIPTION
DDA-4010
BLOCK DIAGRAM DDA-4010 SIGNAL PATH
ALARM A
MON A
OUT 1A
SINGLE / DUAL MODE
IN A
IN B
Optional Relay Bypass on loss of power
In Dual 1 In, 4 Out mode:
IN 1 & IN 2 independently either 3G/HD/SD-SDI or ASI
EQUALISER
EQUALISER
RECLOCKER
SNMP
DATA RATE
RECLOCK / NON-RECLOCK I/P INVERT (x2)
AUTO CHANGEOVER
OUT 2A
OUT 3A
OUT 4A
OUT 4B
OUT 3B
OUT 2B
OUT 1B
MON B
ALARM B
The DDAof distribution and monitoring functions fo
T
wo
settings
Where
The DDAfixed to op
of signal
4010 ser
quad outpu
allo
non-
4010 w
ial digital data distribution amplifi
t reclocking /
w either of the
reclocking is re
ill automaticall
non-
inputs to feed all outputs to
quired, on-board switch settings select between reclocking
y reclock to match the
erate at any one of these rates. Bot
types to be use
d.
r 3G
reclocking
er provides the user with a
/HD/ SD-SD
I or ASI sig
distribution amplifiers a
create a one in, eight out
inpu
t at either 3G
h sides of the DDA-
4010 can be run
singl
e m
odul
e to cover a wide range
nals.
re provided on the one card. On
distribution amplifier.
-SD
I,
HD-SD
and non-
I,
independ
reclocking modes.
SD-SD
I or ASI rates, or can be
ently
allowing a mixtu
board switch
re
The DDA-4010 is also configurable for Automatic Changeover from one input to the other on loss of input signal
allowing for an input Main/Standby scenario.
Due to the nature of ASI signals being phase sensitive, signal inversion is also possible for situations where an
inverted ASI signal needs to be corrected.
Fro
nt
panel LEDs indi
An o
ptional
relay by
event of a power
Simpl
e Network M
ala
rm states when used in an IRT frame fitted with S
The DDAsuitabl
4010 is designed to fit IRT’s 4000 series 3RU frame for use with IRT’s SNMP system as well as being
e with IRT’s 1000 series 1RU Eurocard frames
cate when
pass
failure.
ana
gement Protocol (SNMP)
input signals a
rear
assembly is availabl
re present
is available fo
and wheth
e t
o switch th
NMP c
er the outputs are locked to the
e I
nputs to one of th
r remote setup
apability.
and may be used alongside any oth
inputs.
eir respective Outputs in the
and
m
onitoring of input s
er of IRT’s Eurocar
tat
ds.
us and
Standard features:
•
Switch selectable for 1 in, 8 out single distribution ampli
fier
operation.
•
In-phase
•
Selectable for either 3G/HD/SD-SDI or ASI
•
Automa
•
Front panel monitoring outputs.
•
Front panel indicators provide monitoring of presence of inputs and lock status.
•
Automatic changeover to second input on loss of primary input (selectable).
•
Opti
•
SNMP monitoring and control.
reclocke
tic
d / non
-reclocke
d outputs on each ampli
output muting on no input.
onal relay bypass on loss of po
IRT Electr
onics
Pty Ltd | www.irtelectr
applications
wer.
Page 5 of 21
fier.
.
onics.co
m
Revision 01
DDA-4010
TECHNICAL SPECIFICATIONS
Data Inputs:
Number 2
Impedance 75 Ω, BNC.
Type 3G-SDI, HD-SDI, SD-SDI or ASI (to SMPTE 424M, 292M and 259M-C standards; and
DVB-ASI standard).
Return loss 15dB 5 MHz to 1.485 GHz,
10dB from 1.485 GHz to2.97 GHz1.
Equalisation Automatic 100 m at 3G-SDI rate with Belden 1694A2;
200 m at HD-SDI rate with Belden 1694
400 m at SD-SDI/ASI rate with Belden 16943, 300 m with Belden 8281
Data Outputs:
Number 8 (1 in, 8 out; or (2x) 1 in, 4 out), plus 2 front panel monitoring.
Type Reclocked or non-reclocked, switch selectable.
Level 800 mV ± 10%.
Impedance 75 Ω, BNC.
Return loss 15dB 5 MHz to 1.485 GHz,
10dB from 1.485 GHz to 2.97 GHz1.
Performance:
Reclocking Automatic or selectable for 3G-SDI, HD-SDI or SD-SDI / ASI operation.
Rise Time 3G/HD < 135 ps at 2.97 Gb/s and 1.485 Gb/s;
SD > 0.4 ns and < 1.5 ns at 270 Mb/s.
Intrinsic Jitter < 0.3 UI at 2.97 Gb/s reclocked;
< 0.2 UI at 1.485 Gb/s reclocked;
< 0.1 UI at 270 Mb/s reclocked.
Indicators:
DC LED (green) for module power.
INPUT A LED (green) when signal present on channel A input (LED flashes if present but not active5).
INPUT B LED (green) when signal present on channel B input (LED flashes if present but not active5).
SD LED (green) x2 when SD-SDI or ASI signal present and locked to selected input on
either A or B outputs.
HDLED (green) x2 when HD-SDI signal present and locked to selected input on either A or
B outputs.
3G LED (green) x2 when 3G-SDI signal present and locked to selected input on either A or
B outputs.
Alarm Outputs:
Alarm A A alarm switches to either open circuit or ground (link selectable) via MOSFET relays
on either loss of signal or incorrect signal rate on I/P A.
Alarm B B alarm switches to either open circuit or ground (link selectable) via MOSFET relays
on either loss of signal or incorrect signal rate on I/P B.
Power requirement:
Voltage 28 Vac CT (14-0-14) or ±16 Vdc.
Power consumption < 6 VA.
Other:
Temperature 0 - 50°C ambient.
Mechanical Suitable for mounting in IRT 19" rack chassis with input, output and power
connections on the rear panel.
FinishFront panelGrey background, black lettering & red IRT logo. Rear assemblyDetachable silk-screened PCB with direct mount connectors to Eurocard and external signals.
Dimensions 6 HP x 3 U x 220 mm IRT Eurocard.
Standard Rear connector assembly with matching connector for alarm output.
Optional ZDA-4010RL relay bypass rear assembly suitable for 3G-SDI1, HD-SDI and SD-SDI/ASI signals.
NOTE:1Return loss reduced by a couple of dB at 3G rate with optional bypass relay.
2Reduces to ~ 50m with optional bypass relay rear assembly.
3If two inputs are being inputted, cable equalisation is limited to that of the higher rate.
4Reduces to ~ 70m when SW1-4 (I/P A), SW2-4 (I/P B) is ON.
5When automatic change-over function has been set.
2,3
, 120 m with Belden 8281
2,3
;
3,4
.
Due to our policy of continuing development, these specifications are subject to change without notice.
IRT Electr
onics
Pty Ltd | www.irtelectr
Page 6 of 21
onics.co
m
Revision 01
DDA-4010
CONFIGURATION
The DDA-4010 may be configured as a Dual 1 In, 4 Out or a Single 1 In, 8 Out distribution amplifier either locally via
on board DIP switch settings, or remotely via SNMP.
To configure DDA-4010 via SNMP, DIP switch Sw2-7 must be set to ON.
DDA-4010 DIP Switch Settings:
Input A signal type (rate set) SW1-1 SW1-2
Auto Detect (3G/HD/SD/ASI rates) OFF OFF
SD-SDI / ASI only ON OFF
HD-SDI only OFF ON
3G-SDI only ON ON
SW1-3OFF Reclocking mode. DA behaves as a Reclocking DA. ON Non-Reclocking mode (Reclocker bypassed). DA behaves as a Non-Reclocking DA.
SW1-4OFF I/P A Normal cable equalisation. ON I/P A Reduced cable equalisation to ~ 70m for shorter cable for use in a noisy environment.
SW1-5OFF Single 1 In, 8 Out DA mode.
ON Dual 1 In, 4 Out DA mode (IN A → ‘A’ Outputs (OUT 1A, OUT 2A, OUT 3A & OUT 4A);
(IN B → ‘B’ Outputs (OUT 1B, OUT 2B, OUT 3B & OUT 4B).
SW1-6OFF Non-invert I/P A (Default position).
ON Invert6 I/P A.
SW1-7OFF Auto Changeover Function disabled.
ON Auto Changeover Function enabled.
SW1-8Not Used.
Input B signal type (rate set) SW2-1 SW2-2
Auto Detect (3G/HD/SD/ASI rates) OFF OFF
SD-SDI / ASI only ON OFF
HD-SDI only OFF ON
3G-SDI only ON ON
SW2-3OFF I/P B Reclocking mode. DA behaves as a Reclocking DA. ON I/P B Non-Reclocking mode (Reclocker bypassed). DA behaves as a Non-Reclocking DA.
SW2-4OFF I/P B Normal cable equalisation. ON I/P B Reduced cable equalisation to ~ 70m for shorter cable for use in a noisy environment.
SW2-5OFF I/P A primary I/P of single 1 in, 8 out DA (IN A → All 8 Outputs).
ON I/P B primary I/P of single 1 in, 8 out DA (IN B → All 8 Outputs).
SW2-6OFF Non-invert I/P B (Default position).
ON Invert6 I/P B.
SW2-7OFF DIP Switch control. Settings as per DIP switch settings.
ON SNMP control. Settings as per SNMP settings.
SW2-8OFF Enable major and minor SNMP alarms to the frame Agent (CDM card)7.
ON Disable major and minor SNMP alarms to the frame Agent (CDM card)7.
NOTE:6Due to the nature of ASI signals being phase sensitive, signal inversion is possible with this
switch for situations where an inverted ASI signal needs to be corrected.
7 When using TRAPS via SNMP, depending on how system is set up, in order to avoid double
reporting of alarms via the DDA-4010 card itself and the CDM card (SNMP Agent) of the
frame, major and minor SNMP alarms that are reported to the CDM card of the frame can be
disabled.
Not applicable to Dual mode.
IRT Electr
onics
Pty Ltd | www.irtelectr
Page 7 of 21
onics.co
m
Revision 01