IR-Tec DUOGUARD DP-550P Installation Instructions Manual

R
DUOGUARD
Pet Immune Dual Technology Detector
DP-550P Installation Instructions
GENERAL
INSTALLATION HINTS
The DP-550P may be either wall or corner mounted by applying different knockouts. Corner mount is usually recommended for optimum detection.
Do not install where the detector is in or facing direct/reflected sunlight, window onto main road to avoid
car head light.
Ensure that there are not any obstructions (plants, screens, furniture etc.) within the range which may block the detection.
The detector should not face to the ventilation of HVAC or any equipment that may produce strong temperature change.
Locate the detector at least 1 meter away from the nearest fluorescent light to avoid interference to MW sensor.
The tamper protection will be activated if the locking screw of front cover and bottom case is loosen. Ensure to fix the screw.
Avoid running the alarm cable along with AC mains
cables !!!
DESCRIPTION
PET IMMUNITY NOTICES
Important!!
To ensure optimum pet immunity of this detector, please read the following notices carefully.
1. This detector is immune one domestic pet up to 18 kg or 60 cm moving on the floor. If animal is slightly bigger or taller, mount the detector a bit higher may still maintain similar immunity.
2. If animal activity may take place above 1 meter high, pet immunity allowance will be significantly reduced. It is therefore recommended to select a mounting location where animal’s possible movements are not available within 1.8 m from the detector.
3.
This detector should be mounted on the wall or corner at 2.3 m high and perpendicular to the floor.
Min. 1m
Light
4. DO NOT USE any mounting bracket with swivel adjustment.
5. The weight of animal can only be used as a reference. Other factors such as height and color of fur could also affect the level of immunity.
TAM PER
6. DO NOT AIM the detector at the stairways that animal can climb or pass through.
7. It is vitally important to verify the pet immunity function after installation. If animal movement is detected, relocate the detector may be necessary.
MOUNTING & WIRING
1. Open the front cover and carefully remove the PCB from the bottom case. Select the adequate knockouts and mount the bottom case on.
2. Connect the cable to the correct terminals according to the following instructions. Replace and fix the PCB on the bottom case. Replace the front cover and then walk test can be conducted.
Wiring Diagram
+
ALARM TAM PER
-
Tamper output (NC)
A
larm output (NC/NO)
Power input (9 ~ 16 VDC
)
TAMPER: Connect to the tamper protection loop.
ALARM: Alarm output.
 – : Ground of DC power input.
+: Positive of DC power input.
WALK TEST
It is necessary to carry out a thorough walk test of the detector to ensure correct coverage. Also to ensure that both PIR & microwave sensors are detecting the same area.
1. Apply the DC power supply and give about 60 seconds for sensor to warm up. After the warm up time expires, walk across the detection zones at normal speed. The red LED will lit when it detects the motion.
2. If microwave sensor is over sensitive (green LED remains on), adjust of the thumb wheel of MW sensitivity trimmer in counterclockwise until ideal detection range is obtained.
Warning: Changes or modifications this nit not expressly approved by the party responsible for compliance could void the user’s authority to operate the eqipment.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
Including interference that may cause undesired
operation.
JUMPER SWITCH SETTING
A 6x2-pin jumper switch is available for various settings of the detector. Please refer the following instructions for setting options.
Code Description Placed (ON) Removed (OFF)
MW
MW sensor
detection
Enable MW LED
indication
Disable MW LED
indication
ALM
Alarm relay
output
Enable alarm LED
indication
Disable alarm LED
indication
O/P
Output format N.O. output N.C. output
PIR
PIR sensor
detection
Enable PIR LED
indication
Disable PIR LED
indication
Pulse count selection
Code Pulse count 1 Pulse count 2 Pulse count 3
SWA
ON OFF OFF
SWB
OFF ON OFF
DETECTION PATTERN
110°, 12 x 12m at 25°C Top View
110°
Side View
2.3m
2.5m 8m 12m
SPECIFICATIONS
Power supply ............ 9 ~ 16 VDC, 12 VDC typical
Current drain.............30 mA @ 12 VDC
Infrared sensor..........Dual element, pyroelectric
Microwave sensor.....DRO, patch antenna
MW Frequency .........10.525 GHz
MW output power .....6 mW E.I.R.P. peak
Alarm period .............1.5 ~ 2.5 seconds
Alarm output .............NC/NO, 30 VDC, 0.2A max.
Tamper protection ....NC, screw release activated
Mounting height........2.2~2.3 m
Pulse count...............2/3 selectable
Detectable speed......0.1~3.0 m/sec.
RFI immunity.............Av. 20 V/m (10~1,000 MHz)
Temperature .............-20°C~50°C (-4°F ~ 122°F)
Humidity....................95% RH max.
Dimensions ...............112 x 66 x 45 mm
Loading...