IR Energy Even-GLO GA301 Series Installation, Operation & Mainenance Manual

gas supplier.
Please retain these instructions for future reference.
perform service on these heaters.
23-428 Millen Road
SSeerriieess G
GAA330011
A PATIO HEATER LIKE NO OTHER
Manual for Installation, Operation & Maintenance
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
If you smell gas:
1. Shut off gas to appliance.
2. Extinguish any open flame.
3. If odor continues, immediately call your
Radiant Patio Heater
DANGER
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. A propane cylinder not connected for use shall not be stored in the vicinity of this or any appliance.
* FOR OUTDOOR USE ONLY
* The Even-GLO Patio heater has been approved for indoor use in non-residential
applications (See page 8 for details) for natural gas units ONLY
IMPORTANT: The installer must leave these instructions with
the owner. Only those who are certified to do so should
Stoney Creek ON L8E 3N9 Canada
www.irenergy.ca
Even-GLOTM Series GA301 Page 2 Rev. July/2012
Table of Contents
1 - CAUTION AND GENERAL SAFETY ...................................................................... 4
2 - PRE-INSTALLATION OVERVIEW ........................................................................ 5
WHAT YOU WILL RECEIVE ............................................................................................................ 5
MOUNTING PLATE HOLE PATTERN .................................................................................................. 6
WHAT YOU NEED TO SUPPLY ......................................................................................................... 7
3 - LOCATION PLANNING ...................................................................................... 8
GENERAL LOCATION LAYOUTS ........................................................................................................ 8
LOCATION REQUIREMENTS ............................................................................................................ 8
4 - CLEARANCE TO COMBUSTIBLE MATERIALS ...................................................... 9
CLEARANCE TO COMBUSTIBLES ...................................................................................................... 9
INSTALLATION / CODE REQUIREMENTS ............................................................................................ 9
5 - INSTALLATION INSTRUCTIONS ....................................................................... 10
EQUIPMENT DIMENSIONS ........................................................................................................... 10
5 - INSTALLATION INSTRUCTIONS ....................................................................... 11
POWER / GAS SPECIFICATION ...................................................................................................... 12
6 - ASSEMBLY ...................................................................................................... 13
FLOOR MOUNT ......................................................................................................................... 13
CEILING MOUNT ....................................................................................................................... 19
7 - WIRING .......................................................................................................... 26
WIRING DIAGRAMS ................................................................................................................... 27
INTERNAL WIRING ..................................................................................................................... 27
EXTERNAL WIRING OPTIONS........................................................................................................ 28
8 - LIGHTING & SHUTDOWN INSTRUCTIONS ....................................................... 29
LIGHTING ................................................................................................................................. 29
SHUT DOWN ............................................................................................................................ 29
9 - MAINTENANCE AND TROUBLE SHOOTING ..................................................... 30
MAINTENANCE ......................................................................................................................... 30
TROUBLE SHOOTING .................................................................................................................. 30
10 - PARTS LIST ................................................................................................... 31
12 - WARRANTY .................................................................................................. 33
Even-GLOTM Series GA301 Page 3 Rev. July/2012
CAUTION: FIRE OR BURN INJURY HAZARD
1 - Caution and General Safety
At all times maintain clearance to combustible materials as further specified in this
manual. Failure to do so can result in serious fire hazard.
Never operate heaters in atmosphere containing flammable vapours or combustible
dusts.
This heater is equipped with an electronic and automatic ignition device. Do not attempt
to light the burner by hand. Failure to comply can result in a serious fire and personal injury hazard.
Certain materials, when stored under this heater are subjected to radiant heat can soften,
distort or otherwise be damaged, special care should be taken of plastic materials
Appliance surfaces, other than the obvious flame and emitter surfaces, attain elevated
temperatures during operation. Do not touch the heater head during operation. Everyone should be alerted to this hazard to avoid burning.
Children should be strictly supervised when in the area of this heating appliance. Playing
or running around the structure should be strictly forbidden.
Clothing or other flammable materials should not be hung on or near this heater.
Even-GLOTM Series GA301 Page 4 Rev. July/2012
Top Reflector
Heater head Assembly
Pole Assembly
Hardware
What You Will Receive
2 - Pre-installation Overview
Even-GLOTM Series GA301 Page 5 Rev. July/2012
2 - Pre-installation Overview
Mounting Plate hole Pattern
6.30"
(Full size)
Even-GLOTM Series GA301 Page 6 Rev. July/2012
Ø0.42"
What You Need to Supply
1. Heater post anchoring hardware.
2. Materials necessary to construct a concrete base for floor mounting.
3. Gas supply line that is installed to the Gas and Electric Supply according to the: National Fuel Gas Code, ANSI Z.223.1 (NFPA 54) in the US and Natural Gas and Propane Installation Code, CSA B149.1 or Propane Storage and Handling Code, B149.2 in Canada.
4. Electrical supply rated at 24 Vac with two stage control.
2 - Pre-installation Overview
Even-GLOTM Series GA301 Page 7 Rev. July/2012
NOTE: Sprinkler head heat fuse link performance may alter with age.
WARNING!
3 - Location Planning
General Location Layouts
One Even-GLO heater, at high fire and in windless conditions, has a comfort radius of about twelve feet (24 ft. circle).
A series of heaters providing area heat should be placed about 14-20 feet apart. Wind protection has an important influence on the body’s ability to retain radiant heat. Use
natural or newly built wind barriers where possible, such as existing buildings, shrubbery or tree lines and fences
This heater is NOT approved for any indoor Residential application. If in doubt of your application consult with your local fire marshal or gas authority having jurisdiction. Indoor spaces include but are not limited to attached garages, solariums, living quarters etc.
A patio that has been almost entirely closed in with a roof and windbreak walls or a tent may be considered an indoor location by some code authorities. The Lynx Patio heater has been approved for indoor use in non residential applications (Natural Gas Models ONLY). Venting of the flue gases is accomplished by means of an interlocked fan. Refer to the National Fuel Gas Code, ANSI Z.223.1 (NFPA 54) in the US and CAN/CGA B149.1 and B149.2 Installation Codes in Canada.
Location Requirements
a. Never locate the heater directly below electrical lines, gas lines or sprinkler systems.
b. Do not locate heater too close to vinyl or plastic wall coverings. These materials may
discolour or soften well before they reach combustible limits.
c. Always allow room for removal of the top reflector and heater head for maintenance
purposes.
d. The heater aspirates air for combustion. Do not locate heater where there are severe
draft conditions or airflow restrictions to the heater head base.
Even-GLOTM Series GA301 Page 8 Rev. July/2012
BELOW
TOP
SIDE
CLEARANCE TO COMBUSTIBLES
22"
MODEL NO. TOP SIDES BELOW
33"18"
GA 301
22"
33"18"
GA 301 H
22"
33"18"
GA 301 T
4 - Clearance to Combustible Materials
Clearance to Combustible s
The following clearance data is based on a maximum limit of 90°F (50 °C) plus ambient temperature.
Note with an ambient temperat ur e of 70°F the surface temperatures at the clearance distances listed below could reach 160°F Care should be taken with placement of plastic or vinyl in the proximity of the heater as they tend to distort and soften at these temperatures.
The INSTALLER is responsible to ensure that building materials with a low heat tolerance which may degrade at higher temperatures are protected to prevent degradati on.
Installation / Code Requirements
Installation must comply with local building codes and/or, for the USA/National Fuel Gas Code, ANZI Z 223.1 (NFPA 54) and for Canada, CAN/CGA B149.1 and B149.2, National Gas and Propane Installation Code (latest editions).
Appliance must be electrically grounded in accordance with local codes or, in their absence; the National Electrical Code, ANSI/NFPA 70 in the USA, CSA C22.1 Canadian Electrical Code in Canada.
NOTE: Some materials deteriorate or soften at sustained temperatures below 160°F. Consult mat er ial manu fac tur er for re com me ndations
Even-GLOTM Series GA301 Page 9 Rev. July/2012
89.7"
5.1"
63.0"
39.5"
8"
101.7"
5.1"
39.5"
8"
Model GA 301 Model GA 301-T
75.0"
5 - Installation Instructions
Installation must comply with local building codes and/or, for the USA/National Fuel Gas Code, ANZI Z 223.1 (NFPA 54) and for Canada, CAN/CGA B149.1 and B149.2, National Gas and Propane Installation Code (latest editions).
Appliance must be electrically grounded in accordance with local codes or, in their absence; the National Electrical Code, ANSI/NFPA 70 in the USA, CSA C22.1 Canadian Electrical Code in Canada.
Equipment Dimensions
Floor mount models
Even-GLOTM Series GA301 Page 10 Rev. July/2012
Loading...
+ 23 hidden pages