iqloo MWC8980, MWC8980-BLACK, MWC8980-PLATINUM, MWC499-BLACK Instruction Manual

INSTRUCTION MANUAL
WATER DISPENSER
Model Number : MWC8980/MWC8980-BLACK/
MWC8980-PLATINUM
BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES
AND OPERATING INSTRUCTIONS.
NAME AND STRUCTURE
1 Power indicator 9 Cold switch 2 Water shortage indicator 10 Hot switch 3 Heating indicator 11 Power switch 4 Cooling indicator 12 Condenser 5 Cold Water Button 13 Power cord 6 Hot Water Button 14 Drain valve 7 Drip tray 15 Water pump 8 Door
OPERATION
Ambient temperature
Temperature 0-35°C
Atmosphere 86-106 kpa
VOLTAGE:115V/60HZ
Position the water cooler on the horizontal, structurally sound ground. Leave an adequate open space (10-20 cm) behind the water cooler for good ventilation.
When using the bottles holding ultra-pure water, distilled water or space water with the so-called clever lid, tear off the hygienic labels on the lid.Place the bottles at the intake, then the core of water guard will automatically open the valve and seal it in the meantime, when moving the bottles, the valve will also seal automatically to avoid any possible oozing.
Push the hot water valves, bubbles are generated inside the bottle, indicating that water is flowing into hot water and cold water tanks,keep pressing the hot water valve until water flows out,dispensing cold water required need no particular adjustment.
Caution: Do no connect the electrical power plug,until water comes out of the hot water tap.
After water is flowing out from the hot tap; power can be on, the yellow LED indicator on the front light on.
Turn the heating switch on, the red LED indicator on the front lights on and the heating system starts working, when the hot water comes up (86-95°C) or so, the red light goes off, the heating system stops working is on a warm keeping status. When the hot water temperature is lower than 85°C, the heating system will resume working again automatically.
Turn on the cooling switch, the green LED indicator on the front lights on and the cooling system starts working when the cold water falls down to 5-15°C (for compressor-cooling)the green light goes off, the cooling system stops working and is on a cold keeping status.When the cold water temperature goes up to a set degree, the cooling system will resume working again atomically.
Since the temperature has already been adjusted before leaving the factory, it is unnecessary for customer to set the temperature.
Turn the heating, cooling water switch on.Then the heating and cooling processes start working, the heating indicator is red showing it is heating. When the hot water temperature reaches the set limit, the heating process starts working automatically. When cooling is lit green, the cold water starts working. The cooling indicator goes out as the temperature of the cold water and fridge get the set lower limit. The cooling process stops working,when the cold water temperature gets the set upper limit.The cooling indicator is lit and the process of cold water starts working again. Turn on either the cold water switch, the process can work separately.
Cold and hot water; the red indicator lights on, the heating system works. The red lights goes off, it is on a warm-keeping status ; the green indicator light on, the
cooling system works ; the green light goes off, it is on a cold keeping status.
Cold and hot water cooler (double color indicator); the heating system starts working, the indicator is red. When the heating system stops working is on a warm keeping status, the red indicator change into green. When the cooling system starts working, the indicator is green, when the cooling system stops working is on a cold keeping system, the green indicator change into yellow.
If device is not applied for a long time, after the hot water cools down, please remove the power plug and revolve the drain the rest water in the hot tank then tighten the cap open the cold water tap to drain the rest water in the cold tank.
If there is no water flowing from cooling tap, please shut down the cooling switch until there is water flowing out.
Steps of changing water:
1.Open the door gently to keep it in the suitable distance from the machine to be able to pull out the sucking device.
2. After pulling out the sucking device,you can hang it on the hook of inside.
3. Remove the cap of the bottle,put the sucking device in and press it tightly when changing the bottle.
4. Put the bottle into the body of the water dispenser.
5. The diameter of water bottle should be less than 270mm.
Instructions of water shortage indicator light:
1. When there is water in water shortage tank ,the water shortage indicator light is off.
2. When the water tank is over flowing,the water shortage indicator light is off and alarms for one minute.
3. When there is no water in the water shortage tank,water shortage indicator light flickers.
4. When there is water in storage tank but no water in bottle,the water shortage Indicator light in on& alarm for 30 seconds.
5. When the shortage water tank and bottle are both lack of water,the whole machine is locked,the water shortage indicator light flickers and alarms for 30 seconds.
6. When opening the door,the pump stops working,if the water leverl in the cold tank is higher than the water control leverl,the machine will still work normally.
7. When using a 5 gallon rectangular bottle,slide into place as shown below.
8. After changing water and closing the door,hot and cold tank have been full of water,then water leakage lamp will be off itself.
Loading...