MANUFACTURER'S EXTENDED WARRANTY
In addition to your statutory rights relating to this product it is also guaranteed by IQ (Europe) Limited ("IQ") for 12 months from the date of purchase against faulty materials or workmanship which affect its designed ability to detect or switch. During this period if the product has a defect of this nature it will be repaired or replaced free of charge by IQ with the same item, or a similar one of higher specification, ON CONDITION THAT:-
The buyer takes advantage of any 'return to store' scheme operated by the seller from whom it is bought.
If the product has a defect outside the period of any seller's 'return to store' scheme it should be returned to IQ (Europe) Limited at Sandbeck Lane, Wetherby, W. Yorks LS22 7TW, England at the expense of the buyer together with evidence of the date of purchase (it is the responsibility of the buyer to prove delivery to IQ).
The product has been bought by the user. The product has not been misused or handled carelessly, installed incorrectly, or used on a
voltage supply other than that shown on it. Repairs have not been attempted by anyone other than IQ's staff. The product has been used for domestic purposes only. The product has not been installed in any unusually exposed or harsh environmental conditions. If the buyer is resident in the EU the product or its replacement will be returned to the buyer at
the expense of IQ. This guarantee excludes liability for discolouration of paint or plastic, or any user replaceable
parts and in particular lamps, glass panels, or globes/lanterns. It does not confer any rights other than those expressly set out above and does not cover any claims for consequential loss or damage. This guarantee is offered as an additional benefit and does not affect your statutory rights as a consumer.
This contract is subject to the laws of England and Wales.
*** IMPORTANT ***
As of 1 January 2005, changes to the Building Regulations affect domestic electrical installations in
England and Wales. You don't need to be a qualified electrician to make changes to your home's electrical
system, but the work must be done in accordance with the Regulations.
Where you employ an electrician who is a member of a competent person self-certification scheme, they
will be able to certify the work complies with the Regulations.
If you decide to carry out the work yourself we recommend that you make yourself aware of the
Regulations before you begin and if you require any clarification you should contact your Local Authority
Building Control Department.
Details of the Building Regulations can be obtained on the internet via the government website
www.odpm.gov.uk/explanatory-booklet
SF-PTV180-150-T.qxd 13/04/2005 13:48 Page 2
SECTION ONE
GENERAL INFORMATION
The unit utilises passive infrared technology to detect heat radiation of moving human bodies. This transmitter must be used in conjunction with suitable receivers in the IQ Wirefree range. Upon detection, the transmitter will send a signal to its intended receiver (bought separately) and the receiver will react as programmed. An integral daylight sensor ensures night-only operation of the floodlight.
PLEASE NOTE:- PLEASE SEE THE SEPERATE INSTRUCTION MANUALS FOR THE RECEIVER PRODUCTS TO UNDERSTAND HOW TO PROGRAM AND ADJUST THAT SPECIFIC RECEIVER. THIS MANUAL COVERS THE INSTALLATION OF THISSPECIFIC PIR TRANSMITTER ONLY PARTS INCLUDED
- Luminaire c/w PIR Sensor unit.
- Instruction manual. Please keep safe for future reference.
- Accessory Pack.
- Tungsten halogen bulb
TOOLS & PARTS NEEDED
- Electric/hand-held drill & bits.
- Terminal or Electricians screwdriver
- Large slotted/philips screwdriver
- Wire cutters The Floodlight transmitter is for outdoor use only. Unit must be mounted on a non-flammable surface as a fixed luminaire, and is not suitable for portable use. The unit can get very hot during use. Ensure the unit has cooled before handling. Ensure adequate ventilation space is allowed between the unit and any object above, in front or to either side of the unit. Suggested space is 0.5m above, 0.3m to either side & 1.0m in front. If in any doubt, consult a qualified tradesperson or electrician.
SECTION TWO
FLOODLIGHT TRANSMITTER:-SELECTING THE LOCATION
For optimum performance, mount at 2.5m (8ft) high. The sensor can be pointed in any direction as long as it is within 100m of the receivers it is to be used with. The sensor can detect motion up to 12m within a 180 degree radius.
Avoid areas where pets or traffic may trigger the sensor. Avoid mounting where the Sensor aims at objects that change temperature rapidly, such as central heating vents, air conditioners or waving branches. Avoid reflective surfaces like conservatories or pools of water. Avoid any metal obstructions (support beams, chain link fences etc) that could block the path of radio signal transmission between Sensor and Receiver
The sensor moves up or down, left or right to change the coverage area. Keep in mind the sensor is most sensitive to movement across its field of vision. The motion detector has a number of detection zones, at various vertical and horizontal angles as shown (see diagram A). Amoving human body needs to cross/enter one of these zones to activate the sensor. The best all-round coverage is achieved with the unit mounted at the optimum height of 2.5m. Careful positioning of the sensor will be required to ensure optimum performance. See diagram Adetailing detection range and direction. The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS (see diagram B). Therefore position the unit so that the sensor looks ACROSS the likely approach path. Avoid positioning the sensor where there are any sources of heat in the detection area (extractor fans, tumble dryer exhausts etc.).
SF-PTV180-150-T.qxd 13/04/2005 13:48 Page 3
SECTION THREE
FLOODLIGHT TRANSMITTER:- INSTALLATION
After choosing a suitable location (see previous section) install the unit as follows: The unit is suitable for connection to a 240V 50Hz electricity supply. It is suggested that
3-core round flexible cable of 1mm² gauge is used. An internal switch should be installed to switch the power to the unit ON & OFF. This allows the sensor to be easily switched off when not required or for maintenance purposes.
Unfasten the screw on the top of the floodlight. Install the halogen bulb, making sure not to touch the bulb with bare hands. It is suggested that the bulb is handled using a dry cloth. Ensure the bulb is correctly fitted in the lampholder before use. Re-attach the floodlight front cover, do not overtighten the fixing screw.
This unit uses an integral wall fixing plate, detach the wall fixing plate by unscrewing the fixing screw on underside of the wall plate (diagram E).
The floodlight is located onto the wall plate by a lug which is inserted into the rectangular recess in the top of the wallplate. To remove, slide out the floodlight from the bottom edge (1) and lift upwards (2), the lug will lift out of the recess and seperate from the wall plate. See diagram F
Mark the position of the fixing holes. Ensure wall plate is correctly positioned. (diagram G). Note “TOP” engraving on inside of wall plate.
Drill the holes. Insert wallplugs into the holes.
PIERCE & PASS THE CABLE THROUGH THE GROMMET BEFORE SECURING WALL PLATE TO WALL.
It is recommended that the grommet is pierced with a screwdriver to ensure a better seal. Fix the wall plate to the wall (diagram G) This unit is supplied with a hanging attachment (tether) to aid installation. If it is not required, simply remove from the unit and discard. Ensure the tether is securely fixed into the slot before releasing the weight of the unit. The unit can now be suspended below the wall bracket. (Fig H)
*** IMPORTANT ***
Switch off the electricity at the fuse box by removing the relevant fuse or switching off
the circuit breaker before proceeding with the installation.
CONNECTION
Connect the cable to the terminal block on the unit as follows (see connection diagram):
NEUTRAL (Blue) N EARTH (Green/Yellow)
LIVE (Brown) L Ensure that the connections are secure. Fit the terminal block to the posts on the wall plate
Re-fit the floodlight to the wall plate by locating the lug onto into the recess on the top of the wall bracket, carefully rotate the floodlight so it fits over the wall plate (reverse diagram F) Fully tighten the fixing screw (fig E).
SF-PTV180-150-T.qxd 13/04/2005 13:48 Page 4