The RT322 is a wireless electronic battery powered room thermostat that uses interoperable two-way RF mesh networking technology to provide optimum comfort with close control of the energy used to heat the home without the need for additional wiring or unsightly cable runs.
The RT322 will only operate when 2 x AAA batteries have been fitted and the thermostat is installed and communicating with the receiver unit.
INSTALLATION AND CONNECTION OF THE RT322 SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON.
1
2
3
User Instructions
The RT322 thermostat uses the latest control technology to provide extremely accurate temperature control which will help to keep your energy usage as low as possible without affecting your comfort levels. In fact comfort levels may well be improved as the control accuracy should ensure that the room does not ‘overheat’ before switching off.
The display will show the required temperature setting and can be adjusted in increments of 1°C.
To adjust the required temperature setting turn the dial anti clockwise to decrease it and clockwise to increase it.
Pressing the temperature setting dial will allow the user to check the current actual measured room temperature which will be displayed for approx 7 seconds before returning to the set temperature.
When the thermostat is in the ‘call for heat’ condition a flame symbol will appear in the display.
The aerial symbol complete with radio wave symbols in the display of the RT322 thermostat indicates that it is communicating satisfactorily with the receiver.
A flashing radio wave indicates a loss of communication. This may be temporary and can often be restored by turning the thermostat dial and increasing or decreasing the temperature to make the thermostat switch. If this has no effect please see Z-Wave pairing instructions on page 10.
A radio mast symbol with no radio waves indicates that the RT322 has not been signed on to enable it to communicate with the receiver. In this case you may wish to contact the Installer as the indication is that the product has not been commissioned when the installation took place. Alternatively see the Z-Wave pairing instructions on page 10.
Battery replacement
The RT322 runs on 2 x type AAA (Alkaline) non rechargeable batteries and is designed to give a battery life of approximately two years.
When the batteries are nearing the end of their life a low battery symbol will appear in the display and the batteries should be changed within a few days. If the batteries are not changed at this point eventually a ‘LO’ battery message flashes intermittently in the display and if this happens the batteries should be changed immediately.
To change the batteries it is necessary to remove the thermostat from the wall. To do this first undo the two captive screws at the base of the thermostat and swing the thermostat up and away from the wall plate.
Remove the old batteries and replace them with two new AAA size alkaline batteries ensuring that they are fitted correctly as indicated by the terminal markings in the battery compartments.
Once the batteries are fitted, re-fit the thermostat to the wall plate by engaging with the lugs at the top of the wall plate and push the thermostat into position. Locate it over the captive screws at the base of the wall plate and tighten so that the thermostat is locked into position.
Check the temperature setting is correct and adjust if necessary.
Please dispose off the batteries responsibly.
Receiver unit
The receiver unit receives the Z-Wave radio signals from the room thermostat. In the unlikely event of a communication failure it is possible to override the system and switch On and Off using the On/Off buttons on the receiver as a local override.
If the override is used to override the thermostat when it is functioning correctly then the override will be cancelled by the next switching operation of the thermostat and normal operation will be resumed. In any case, with no further intervention, normal operation will be restored within one hour of the override being operated.
4
Batteries should be changed immediately
Low battery symbol appears first when the batteries are nearing the end of their life