iQe CP017 Installation Instructions Manual

CP017
INSTALLATION INSTRUCTIONS
The CP017 single channel timeswitch offers up to three on/off periods a day with a one hour boost and instant advance facility.
Installation and connection should only be carried out by a suitably qualified person and in accordance with the current edition of the IEE wiring regulations.
1
Fitting the backplate
Once the backplate has been removed from the p a c k a g i n g p l e a s e ensure the timeswitch is re-sealed to prevent damage from dust and debris.
The backplate should be fitted with the wiring terminals located at the top and in a position that allows a total clearance at last 50mm around the unit.
Direct wall mounting
Offer the backplate to the wall in the position where the timeswitch is to be mounted, remembering that the backplate fits to the left hand end of the control. Mark the fixing positions through the slots on the backplate (fixing centres of 60.3mm), drill and plug the wall, then secure the backplate in position. The slots in the backplate will compensate for any misalignments of the fixings.
Wiring box mounting
The backplate may be fitted directly onto a single gang steel flush wiring box complying with BS4662, using two M3.5 screws. The CP017 is suitable for mounting on a flat surface only; they must not be positioned on a surface mounted wall box or on unearthed metal surfaces.
N L
1 2 3 4
100mm
50mm
50mm
50mm
2
Electrical connections
All necessary electrical connections should now be made. Flush wiring can enter from the rear through the aperture in the backplate. Surface wiring can only enter from beneath the timeswitch and must be securely clamped. The mains supply terminals are intended to be connected to the supply by means of fixed wiring. Recommended cable sizes are 1.0 or 1.5mm2
The CP017 is double insulated and does not require an earth connection but an earth connection is provided on the backplate for terminating cable earth connectors. Earth continuity must be maintained and all bare earth connectors must be sleeved. Ensure no earth conductors are left protruding outside the central space enclosed by the backplate.
Internal wiring diagram - CP017
New Installations
Example circuit diagrams for some typical installations are shown on pages 4, 5 and 6. These diagrams are schematic and should be used as a guide only.
Please ensure that all installations comply with current IEE regulations.
3
The CP017 has voltage free contacts. A link L - 2 is required for mains voltage applications
N
L
1
2
3
4
230V 50Hz
OFF ON
COMM
For reasons of space and clarity not every system has been included and the diagrams have been simplified - for example some Earth connections have been omitted.
Other control components shown in the diagrams, i.e. Valves, Room Stats etc are general representations only. However the wiring detail can be applied to the corresponding models of most manufacturers.
Cylinder and Room Thermostat key; C = Common; CALL = Call for heat or break on rise; SAT = satisfied on rise; N = neutral.
1. Typical combination boiler installation
N
L
1 2
3
4
MAINS SUPPLY
E
N L
FOR PRECISE TERMINAL CONNECTION INFORMATION PLEASE RFFER TO BOILER MANUAL, INSTRUCTIONS.
COMBINATION BOILER TERMINALS
E N
L
REMOVE LINK IF FITTED
BOILER LIVE OUT
TERMINALS-L2 SHOULD NOT BE LINKED
SWITCHED LIVE
TO BOILER
4