IPS IPS600-SIN-WM, IPS300-SIN-WM, IPS600-SIN-DC, IPS1000-SIN, IPS1000-SIN-DC User Manual

...
IPS home inverter manual
www.ips-ups.eu 4.09.2017 info@ips-ups.eu IPS-home-inverter-manual_ENG-R1
1
USER MANUAL
IPS home inverters with UPS function
Suitable for UPS:
- IPS300-SIN
- IPS300-SIN-WM
- IPS300-SIN-DC
- IPS600-SIN
- IPS600-SIN-WM
- IPS600-SIN-DC
- IPS1000-SIN
- IPS1000-SIN-DC
- IPS1600-SIN
- IPS1600-SIN-DC
- IPS2500-SIN
- IPS3500-SIN
IPS home inverter manual
www.ips-ups.eu 4.09.2017 info@ips-ups.eu IPS-home-inverter-manual_ENG-R1
2
Table of Contents
1 Safety Information .............................................................................................. 1
2 Product Overview ............................................................................................... 4
2.1 Specifications ............................................................................................... 4
2.2 Front panel features ..................................................................................... 6
2.3 Rear panel features ..................................................................................... 6
3 Installation Instructions ..................................................................................... 8
3.1 Unpacking Inspection.. ................................................................................. 8
3.2 Installation .................................................................................................... 8
4 Operations ......................................................................................................... 10
4.1 Turn the inverter On/Off ............................................................................. 10
4.2 Display interface ........................................................................................ 10
4.3 Settings ...................................................................................................... 10
4.4 Troubleshooting ......................................................................................... 13
IPS home inverter manual
www.ips-ups.eu 4.09.2017 info@ips-ups.eu IPS-home-inverter-manual_ENG-R1
3
Models quick description
IPS300-SIN
Standalone metal
case
IPS300-SIN-DC
Standalone metal case with DC output and PV
input
IPS600-SIN
IPS600-SIN-DC
IPS1000-SIN
IPS1000-SIN-DC
IPS1600-SIN
IPS1600-SIN-DC
IPS2500-SIN
IPS300-SIN-WM
Wall mounted metal case
IPS3500-SIN
IPS600-SIN-WM
1 Safety Information
CAUTION
Non-qualified electricians are forbidden to open the case due to hazard of electrical shock.
Consulting the dealer is required before using for below equipment. Its application, configuration, management and maintenance must be specially considered and designed.
Medical equipment which is directly related to patients’life Elevator and other equipment which may endanger personal safety
Safety and General Information
Read all safety information and operating instructions carefully before attempting to install, operate, service or maintain the
inverter.
Do not disassemble this inverter. Contact your local service center if maintenance or repair is needed. Disconnect all connection wiring before maintenance or cleaning to avoid the risk of electric shock. Do not use liquid extinguisher if there is a fire, a dry powder extinguisher is recommended. Do not dispose of the batteries with fire. The batteries may explode. Do not open or mutilate batteries. Released electrolyte inside is harmful to the skin and eyes, and maybe toxic. Do not connect the positive pole and negative pole directly, otherwise it will cause electric shocks or will be on fire.
IPS home inverter manual
www.ips-ups.eu 4.09.2017 info@ips-ups.eu IPS-home-inverter-manual_ENG-R1
4
2 Product Overview
2.1 Specifications
MODEL
300W
600W
1000W
1600W
2500W
3500W
DC Input (the inverter must be connected to batteries to work properly)
Nominal input voltage
12V
24V
DC input range
10 ~ 15V
20 ~ 30V
AC Input
Bypass input range
0 ~ 264Vac for 220Vac/230Vac/240Vac,
Mains input range
150 ~ 282Vac for 220Vac; 156 ~ 294Vac for 230Vac; 163 ~ 307Vac for 240Vac;
Input frequency range
50Hz / 60Hz (Auto-sense& Settable:5% ~15%,default 15%),
42.5 ~ 57.5Hz for 50Hz, 51 ~ 69Hz for 60Hz
Input range of the generator
99 ~ 282Vac for 220Vac; 104 ~ 294Vac for 230Vac; 108 ~ 307Vac for 240Vac; No AVR in generator mode
Input frequency range of the generator
40 ~ 70Hz
Input power matching of the generator
Rated power 10% ~ 150%,
regulating step 10%default 120%
Output
Inverter output range
220Vac / 230Vac / 240Vac ± 5% or
Bypass output range
0 ~ 264Vac for 220V/230V/240V,
Mains output range
174 ~ 242Vac for 220Vac; 182 ~ 253Vac for 230Vac; 190 ~ 264Vac for 240Vac;
Output frequency
50Hz / 60Hz ± 0.3 (Auto-sense & settable)
Output waveform
Pure sine wave
Output power
300W
600W
1000W
1600W
2500W
3500W
Putput sockets
2x schuko CEE 7/3
Block terminal
Efficiency
Max. 95% (Mains mode); Max. 80% (Inverter mode)
ECO mode
Settable, load<3%,enter in 80 s
No-load shutdown
Settable, time can be set (1 ~ 99 min), load can be set (3% ~ 50%)
Transfer time
≤ 10 ms
≤ 15 ms
Power factor
1.0
THDV
< 5% (linear load)
Inductive load
Yes
Motor load
Yes
Rectifier load
Yes
Overload capability
Mains mode: 110% 120 s; 125% 60 s; 150% 10 s (switch to bypass)
Inverter mode: 110% 60s; 125% 10 s; 150% 10s (shut down)
Battery
String battery q-ty
1 1 1 2 2
2
Charging current (selectable)
Default
10A
Default 20A, regulating step 1A (< 10A) / 5A (> 10A)
Max. 15A
Max. 30A
Max. 40A
Max. 40A
Max. 50A
Max. 60A
Equalizing charge voltage
Single battery 14.4Vdc (default), 13.6 ~ 15Vdc settable
Floating charge voltage
Single battery 13.7Vdc (default), 13.2 ~ 14.6Vdc settable
DOD
Single battery 10.8Vdc (default), 9.6 ~ 13Vdc settable
EOD
Single battery 10.2Vdc (default), 9.6 ~ 11.5Vdc settable
Reverse warning
Buzzer
Alarm
Switch on / off
Continuous beep 2 s
Low battery
Beep 0.2 s at interval of 0.4 s
Overload
Beep 2 s at interval of 2.5 s
Mains power abnormal
Beep 0.3 s at interval of 5 s
MPPT Modules (for –DC series only)
Model
40A
/
/
IPS home inverter manual
www.ips-ups.eu 4.09.2017 info@ips-ups.eu IPS-home-inverter-manual_ENG-R1
5
Max. PV input voltage(Voc)
40 V
60 V
/
/
PV optimum operating voltage(Vmp)
18 V ~ 32 V
29V ~ 48 V
/
/
Max.PV. power
120W / 240W / 360W / 480W
240W / 480W / 720W / 960W
/
DC Outputs (for –DC series only)
Model
5V (2A), 9V / 12V (1A), 15V / 24V (1A),
2pin socket: 12V (10A)
Other
1x PoE, 2x USB 5B (2A)
Others
Protections
Overload – short-circuit – overvoltage – undervoltage – overcharge –
overtemperature – excessive low battery – missing insert
Interface
LCD & BUZZER
Operating temperature
0℃ ~ 40
Operating humidity
Relative humidity ≤ 93%
Altitude
< 1000m, (above 1000m, derating 1% for each additional 100 m),
4000 m max.
Net weight (kg)
8.0/8.5/7.4
10.9/11.4/11
14.0/14.6
18.0/18.5
32.0
36.0
Gross weight (kg)
9.0/9.5/8.4
11.9/12.4/12
15.0/15.6
19.0/19.5
34.0
38.0
Dimensions (W×D×H)
mm
280×258×120 (w/o option) 293×280×160 (w/ option)
400×210×127 (Wall mounted)
293×280×160
302×479×209
Packaged dimensions (W×D×H) mm
330×352×200 (w/o option)
370×355×235 (w/ option) 490×290×195 (Wall
mounted)
370×355×235
353×582×287
Note: Specifications are subject to change without noticeMPPT modules and DC modules are optional.
Charging features
Charging process
Three-stage:
CC (constant current) CV (constant voltage) Float (floating charge)
Process diagram
Constant voltage charging time: 60 S