iPower SUA12000ED User Manual

OWNER'S MANUAL & OPERATION INSTRUCTION
DUAL-FUEL GENERATOR SERIES
12000 10800
SAVE THIS MANUAL: This manual contains important information regarding safety,operation,
maintnance and storage of this product. Before use, read carefully and understand all cautions, warnings, instructions and product labels. Failure to do so could result in serious personal injury and/or property damage.
Starting watts
Starting watts
/
9000
/
8100
Running watts
Running watts
SUA12000ED
CALIFORNIA PROP65 WARNING
A-iPower Corp. - Fontana, CA 92337 USA www.a-ipower.com 1-855-888-3598 or support@a-ipower.com.
TABLE OF CONTENTS
17 For Gasoline 20 For LPG
A-iPower Corp. - Fontana, CA 92337 USA www.a-ipower.com 1-855-888-3598 or support@a-ipower.com.
3
TABLE OF CONTENTS
Operation
Using Electric Power AC Application
Stopping the Generator
Stopping the Generator Oil Sensor
Maintenance
Transporting
4
Storage
28
Warranty
29
A-iPower Corp. - Fontana, CA 92337 USA www.a-ipower.com 1-855-888-3598 or support@a-ipower.com.
INTRODUCTION
Attention: Read through the complete manual prior to the initial use of your generator.
Using the Operator’s manual
The operating manual is an important part of your generator. It should be read thoroughly before initial use, and referred to often to make sure adequate safety and service concerns are being addressed.
Reading the owner’s manual thoroughly will help avoid any personal injury or damage to your machine. By knowing how best to operate this machine you will be better positioned to show others who may also operate the unit.
This manual is written to take you from the safety requirements to the operating functions of your machine. You can refer back to the manual at any time to help troubleshoot any specific operating functions, so store it with the machine at all times.
A-iPower Corp. - Fontana, CA 92337 USA www.a-ipower.com 1-855-888-3598 or support@a-ipower.com.
5
SAFETY
Save these Instructions
Safety Rules
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
The safety alert symbol ( ) is used with a signal word (DANGER, CAUTION, WARNING), a symbol and/or a safety message to alert you to hazards.
DANGER indicates a hazard which, if not avoided, will result in death or serious injury.
WARNING indicates a hazard which, if not avoided, could result in death or serious injury.
CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury.
NOTICE indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.
TOXIC FUMES
6
Hazard Symbols and Meanings
EXPLOSION
A-iPower Corp. - Fontana, CA 92337 USA www.a-ipower.com 1-855-888-3598 or support@a-ipower.com.
FIRE ELECTRIC SHOCK
KICKBACK READ MANUAL
SAFETY
WARNING
Generator exhaust contains carbon monoxide, a poisonous gas that can kill you.
You CANNOT smell or see this gas.
Use the generator outdoors, away from open windows, vents, or doors that could allow the carbon monoxide gas to come indoors. Keep the generator at least 1 meter (3 feet) away from any structure or building during use.
NEVER use a generator indoors, including in homes, garages, basements, crawl spaces, and other enclosed or partiallyenclosed areas, even with ventilation. Opening doors and windows or using fans will not prevent carbon monoxide buildup in the home.
NEVER use a generator in enclosed or partially-enclosed spaces. Generators can produce high levels of carbon monoxide very quickly. When you use a portable generator, remember that you cannot smell or see carbon monoxide. Even if you can’t smell exhaust fumes, you may still be exposed to carbon monoxide.
NEVER operate the generator in an explosive atmosphere, near combustible materials or where ventilation is not sufficient to carry away exhaust fumes. Exhaust fumes can cause serious injury or death.
If you start to feel sick, dizzy, or weak while using a generator, get to fresh air RIGHT AWAY. DO NOT DELAY. The carbon monoxide from generators can rapidly lead to full incapacitation and death.
If you experience serious symptoms, get medical attention immediately. Inform medical staff that carbon monoxide poisoning is suspected. If you experienced symptoms while indoors, have someone call the fire department to determine when it is safe to re-enter the building.
A-iPower Corp. - Fontana, CA 92337 USA www.a-ipower.com 1-855-888-3598 or support@a-ipower.com.
7
SAFETY
WARNING
Starter cord kickback (rapid retraction) will pull hand and arm toward engine faster than you can let go which could cause broken bones, fractures, bruises, or sprains resulting in serious injury.
When starting the engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in and turned on.
WARNING
Fuel and its vapors are extremely flammable and explosive.
Fire or explosion can cause severe burns or death.
When Adding or Draining Fuel
Observe all safety regulations for the safe handling of fuel. Handle fuel in safety containers. If the container does not have a spout, use a funnel. Do not overfill the fuel tank, leave room for the fuel to expand.
Do not refill fuel tank while the engine is running. Before
refueling the generator, turn it off and let it cool down. Gasoline spilled on hot engine parts could ignite. Fill the tank only on an area of bare ground. While fueling the
tank, keep heat, sparks and open flame away. Carefully clean up any spilled fuel before starting engine. Always fill fuel tank in an area with plenty of ventilation to avoid
inhaling dangerous fumes. NEVER store fuel for your generator in the home. Gasoline,
propane, kerosene, and other flammable liquids should be stored outside of living areas in properly-labeled, non-glass safety containers. Do not store them near a fuel-burning appliance, such as a natural gas water heater in a garage. If the fuel is spilled or the container is not sealed properly, invisible vapors from the fuel can travel along the ground and can be ignited by the appliance’s pilot light or by arcing from electric switches in the appliance.
8
A-iPower Corp. - Fontana, CA 92337 USA www.a-ipower.com 1-855-888-3598 or support@a-ipower.com.
SAFETY
This product has been designed with internal grounding or floating bonded neutral. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.
DANGER
Improper grounding can result in a risk of electrocution. Check with a qualified electrician for your local requirements if you are in doubt as to whether the unit is properly grounded.
This generator is equipped with a grounding terminal for added protection. Using the ground path from the generator to an external ground source as instructed in the section labeled “Grounding Instructions” in the Preparation section of this manual can be necessary. Please consult a qualified electrician for local regulations. The generator is a potential source of electrical shock if not
kept dry. Keep the generator dry and do not use in rain or wet conditions.
To protect from moisture, operate it on a dry surface under an open, canopy-like structure. Dry your hands if wet before touching the generator. Plug appliances directly into the generator. Or, use a heavy duty,
outdoor-rated extension cord that is rated (in watts or amps) at least equal to the sum of the connected appliance loads. Check that the entire cord is free of cuts or tears and that the plug has all three prongs,especially a grounding pin. NEVER try to power the house wiring by plugging the generator
into a wall outlet, a practice known as “back feeding”. This is an extremely dangerous practice that presents an electrocution risk to utility workers and neighbors served by the same utility transformer. It also bypasses some of the built-in household circuit protection devices. If you must connect the generator to the house wiring to power appliances, have a qualified electrician install the appropriate equipment in accordance with local electrical codes.
A-iPower Corp. - Fontana, CA 92337 USA www.a-ipower.com 1-855-888-3598 or support@a-ipower.com.
9
SAFETY
Important Safety Instructions
WARNING
To reduce the risk of injury, read this operator’s manual completely before using.
When using this product, the following basic precautions should always be followed.
Do not enclose the generator or cover it. The generator may become overheated if it is enclosed. If generator has been covered to protect if from the weather during non use, be sure to remove it and keep it well away from the area during generator use. Operate the generator on a level surface. It is not necessary to
prepare a special foundation for the generator. However, the generator will vibrate on an irregular surface, so choose a level place. If the generator is tilted or moved during operation, fuel may spill and/or the generator may tip over, causing a hazardous situation. Proper lubrication cannot be expected if the generator is operated on a steep incline or slope. In such a case, piston seizure may occur even if the oil is above the upper level. Pay attention to the wiring or extension cords from the generator
to the connected device. If the wire is under the generator or in contact with vibrating part, it may break and possibly cause a fire, generator burnout, or electric shock hazard. Replace damaged or worn cords immediately. Do not operate in rain, in wet or damp conditions, or with wet
hands. The operator may suffer severe electric shock if the generator is wet due to rain or snow. If wet, wipe and dry it well before starting. Do not pour water directly over the generator, nor wash it with water. Be extremely careful that all necessary electrical grounding
procedures are followed during each and every use. Failure to do so can be fatal. DO NOT smoke while charging a battery. The battery emits
flammable hydrogen gas, which can explode if exposed to electric arcing or open flame. Keep the area well ventilated and keep open flames / sparks away when charging a battery. The engine becomes extremely hot during and for some time after
operation. Keep combustible materials well away from generator area. Be very careful not to touch any parts of the hot engine especially the muffler area or serious burns may result.
10
A-iPower Corp. - Fontana, CA 92337 USA www.a-ipower.com 1-855-888-3598 or support@a-ipower.com.
SAFETY
Keep children and all bystanders at a safe distance from work area. It is absolutely essential that you know the safe and proper use of
the power tool or appliance that you intend to use. All operators must read, understand and follow the tool / appliance owners manual. Tool and appliance applications and limitations must be understood. Follow all directions given on labels and warnings. Keep all instruction manuals and literature in a safe place for future reference. Always switch off generator’s AC circuit breaker and disconnect
tools or appliances when not in use, before servicing, adjusting, or installing accessories and attachments. Make sure the engine is stopped before starting any maintenance,
servicing or repair.
NOTE:
Ensure maintenance and repair of the generator are performed by
properly trained personnel only.
SAVE THESE INSTRUCTIONS
A-iPower Corp. - Fontana, CA 92337 USA www.a-ipower.com 1-855-888-3598 or support@a-ipower.com.
11
Loading...