IOT-Smart Solutions KBD-5820 User Manual

1
KBD-5820
Intelligent Keyboard Controller
User Manual
Content
1. Keyboard introduction ...............................................................................................................2
1.1 Keyboard main features ......................................................................................................2
1.2 Keyboard layout..................................................................................................................2
1.3 T echnical data......................................................................................................................3
2. Keyboard installation.................................................................................................................5
2.1 The back view .....................................................................................................................5
2.2 Installation...........................................................................................................................5
3. Keyboard Setting........................................................................................................................7
3.1 General Introduction ...........................................................................................................7
3.2 Keyboard Setting log-in...................................................................................................... 7
3.3 Keyboard Setting.................................................................................................................7
4. Direct Control............................................................................................................................14
4.1 Direct control Log-in.........................................................................................................14
4.2 Direct control menu...........................................................................................................14
4.3 switch camera....................................................................................................................14
4.4 Direct Cam Control...........................................................................................................15
5. Standalone DVR Control.........................................................................................................18
5.1 log onto DVR....................................................................................................................18
5.2 DVR Control Window.......................................................................................................18
1
Intelligent keyboard Controller Installation user manual
1. Keyboard introduction
Intelligent network keyboard is designed to directly control high speed / low speed dome cameraPTZ camera, standalone DVR and matrix switcher.
1.1 Keyboard main features
3-Axis joystick, position exactly Meticulous LCD, operate help information plentiful and real-time
Silica gel keystroke back light subarea display, durable for using. Support self-inspection of joystick/keyboard/LCD/port
1.2 Keyboard layout
figure 1-1 keyboard layout
LCD Main board
Orange Backlight
【0】…【9】: Figure 【F1】…【F5】:Shortcut button 【CANCEL】: Cancel 【ENTER】: Confirmation key 【PREV】: Switch to last dome; move the cursor upward on menu 【NEXT】: Switch to next dome; move the cursor downward on menu 【PRESET】: Function key for preset position 【LOCK】: Lock 【SITE】: Choose a device 【MACRO】: Macro function key
2
Two wires of RS-485 port can control multi-domes.
【ALARM】: Disalarm function key 【ARM】: Arm/Disarm function key 【PGM】: Program key 【SHIFT】: Combination key 【MON】: Monitor switching key 【CAM】: Camera switching key
Lens control key
AIris close B: Iris open CFocus near DFocus far EZoom out F: Zoom in
Three -dimensional Joystick
figure 1-2 Lens control keys
1.3 Technical data
operating temperature: -10~50 operating humidity <90% operating voltage DC12V power consumption 5W Ethernet port: 10Base-T UDP
dimensionsmm): 345×175×98(length × width× height)
3
【figure 1-3 keyboard dimension】
4
2. Keyboard installation
2.1 The back view
figure 2-1 keyboard back panel
MINI USB :Program upgrade USB RS -485: Two lines of RS-485 control, for connecting PTZ and DVR Dip switch :Reserved for further use RS -232:Reserved for further use Network conne ction: for connecting matrix switcher Power input :DC12V/1000mA Power switch
2.2 Installation
5
2.2.1 PTZ Control
Connect RS-485 port on the keyboard with RS-485 port on camera. (two equipment A/B/G separately connect) ,connect and power on keyboard. In log-in menu, select direct control, input keyboard ID and password, and it’s done. Before log-in, user needs to add direct control device to keyboard in keyboard setting menu, .
Quick guidance:
1. Enter keyboard setting menu, input keyboard ID and password
defaultpassword“000000” add direct control device to keyboard and also set the
correct protocol and baud rate.
2. In log-in menu, select direct control and input keyboard ID (default 1) and password
(default 000000) to enter direct control window.
3. In direct control window, input camera ID, press【CAM】to confirm or change the
current ID.
4. Use joystick and lens control keys to control the up, down, left, right and zoom of
speed dome camera.
2.2.3 Standalone DVR Control
Intelligent keyboard controller can control popular standalone DVR. Connect DVR to
RS-485port on keyboard. Power on keyboard and switch on it. After keyboard screen displays log-in menu, select DVR device, input keyboard ID and password. Before log-in, user needs to add DVR to keyboard through keyboard setting menu. Also user needs to set the keyboard ID for controlling DVR in keyboard setting menu.
Quick guidance:
1. Enter keyboard setting menu, in keyboard attribute, add DVR to keyboard, set
keyboard ID for controlling DVR.
2. Enter keyboard log-in menu, select DVR ID number, input keyboard ID(default 1) and
password (default 000000)to enter DVR control menu.
3. In DVR control menu, user can control DVR. PressIris Offto switch to PT Z control
mode. In PTZ control mode, user can control PTZ camera. Press【CANCEL】to go
back to DVR control mode.
6
3. Keyboard Setting
3.1 General Introduction
If this is the first time that you use intelligent keyboard controller, please read this
chapter carefully. This chapter will guide you to set the network attribute, control device attribute, hardware function and complete hardware testing.
The soft keys on keyboard screen corresponds with shortcut key buttons on keyboard F1】~【F5. Press shortcut button to use soft key function. < > represents soft key in this manual.
3.2 Keyboard Setting log-in
Power on keyboard while holding 【PGM】,keyboard will enter its setting window. Input
user ID and password to log in. This keyboard support 4 user IDuser ID are 1、2、3、 4),password is six digits, default password000000.
Keyboard setting
user 1 password ******
figure 3-1 keyboard setting log-in
3.3 Keyboard Setting
In keyboard setting window, user can modify network parameters such as keyboard IP address and subnet mask code, as well as relevant attributes of control device, adjust backlight and key tone, test key buttons and joystick.
network device kbd test exit
Keyboard function setting
figure 3-2 keyboard function setting
3.3.1 Network Attributes Setting
Press soft key <network> to enter network attributes setting. Set keyboard IP address,
subnet mask code, network gate and MAC address.
7
figure 3-3 keyboard network attributes setting
Press corresponding soft key to enter modification. Input numbers to change 按 values.
Press【PREV】to move forward, press【NEXT】、【ENTER】to move backward. Press <exit> to return.
figure 3-4 set keyboard network attributes
After modification, press<save>keyboard pops up a hint. Press【ENTER】<exit>to
return.
figure 3-5 save keyboard network attributes
3.3.2 Device Attributes Setting
In keyboard function setting menu (see figure 3-2), press<device> to enter device
attributes setting.
Each keyboard supports 10 devices at the maximumdevice ID is 1-10. Devices are
divided into four types:“no device”、“matrix”、“direct control”“DVR”.
Input ID number in Device, press【ENTER】to confirm.
Network attributes setting
IP mask gate MAC exit
Network attributes setting
IP address 10 .10 .10 .80 save exit
Network attributes setting
save exit
Save success
Device 1 type no device exit
Device attributes setting
8
figure 3-6 Device attributes setting In type selection box, press【PREV】、【NEXT】to select control devices,press ENTERto confirm, then it enters the device attribute setting menu for the selected device.
figure 3-7 select device type
After select matrix, it enters matrix attribute setting menu. Set matrix IP address, and
press <save> to save setting.
figure 3-8 set matrix network attribute
After select direct control, it enters pan/tilt attribute setting menu.需要 Set
communication protocol and baud rate. Press【PREV】、【NEXT】to select communication protocol and baud rate. Press【ENTER】to move cursor to baud rate selection box. Press CANCELto move cursor to communication protocol selection box. Press <save> to
save settings. Communication protocol for selection: TPELCOPrelates to PelcoP)、TPELCOD relates to PelcoD. Baud rate for selection: 2400bps、4800bps、9600bps、19200bps.
figure 3-9 set pan/tilt direct control attribute
After select DVR, it enters DVR attributes setting menu. Set an keyboard ID for
controlling DVRrange 1-16. Press <save> to save settings.
Device attributes setting DVR port RS485 DVR KBD ID 1
save exit
Device attributes setting Direct control port RS485 Protocol TPELCOP baud rate 9600
save exit
Device 1 Type matrix exit
Device attributes setting Matrix IP address 10 .10 .10 .50
save exit
Device attributes setting
figure 3-10 set DVR keyboard ID
9
After select “no device”, press 【ENTER】to confirm. After saving setting, the current ID is
set to be occupied by no device.
figure 3-11 device type set to be “no device”
3.3.3 Keyboard Attributes Setting
In keyboard function setting menu(see figure 3-2),press <keyboard> to enter keyboard
attribute setting menu.
figure 3-12 keyboard attribute setting
Modify user password Press<password> to enter keyboard user password modification menu.
Input user ID(keyboard supports 4 user ID,range 1-4),press ENTER】to 键将 move
cursor to password input box. Input original password, after verification, input new password twice.
exit
Password modification
user 1 password new password confirm eixt
keyboard attribute setting
password delay hardware language exit
Save complete
Device attributes setting
figure 3-13 Password modification
Backlight delay, lock delay
Press soft key <delay> to enter. Backlight delay: delay time 1-60 minutesset 0 to remain on. Lock delay: keyboard will be locked after a period if no operation is executed. Delay
time 1-60 minutesset 0 to remain unlocked. No password is needed to unlock the keyboard.
Press <save> to save settings.
10
figure 3-14 Delay function setting
LCD contras, key tone Press <hardware> to enter hardware setting menu.
Keyboard LCD contrast range 1-7. Key tone can be turned on or off by pressing NEXT】、【PREV】. Press <save> to save settings.
figure 3-15 keyboard hardware setting
Language Selection
Press <language> to enter language selection menu. Keyboard support two languages: Chinese and English, press【NEXT】、【PREV】to choose language. Press <save> to save settings.
figure 3-16 Language selection
3.3.4 Keyboard Testing Function
In keyboard function setting menusee figure 3-2),press<test> to enter keyboard function testing menu.
Keyboard function testing
key joystick exit
Language selection
language English save exit
Hardware setting
LCD contrast 4 Key tone off save exit
backlight 5 lock 5 save exit
Delay function setting
figure 3-17 keyboard function testing
11
Key button testing Press <key> to enter key button testing menu.
In key button testing menu, press key buttons on keyboard, the corresponding 在 name
will be shown in the box. This is to test the function of key buttons.
figure 3-18 keyboard testing
Joystick Calibration
Press <joystick> to enter joystick testing menu.
figure 3-19 joystick testing
Center value: enter joystick center value setting menu, release joystick to let it
resume to center position, press <set> to set the center value.
figure 3-20 Joystick center value setting
Max valueEnter max value setting menu, move joystick up, down, left and right to
its maximum on after another, meanwhile, press <set> to set the max value for this direction.
Joystick max value setting
571 511 723 731 591 set 559 exit
Joystick center value setting
498 504 491 set exit
Joystick testing
center max blind exit
Key test(SHIFT+CANCEL exit)
SHIFT through(SHIFT+1)to test
Key button testing
figure 3-21 Joystick max value setting
Blind area: Enter joystick blind area setting menu, input blind area value range
20-60. Default blind area is suggested to be around 25. As time go on, accuracy of components will change, user may increase blind area accordingly.
12
figure 3-22 Joystick blind area setting
Please make sure to calibrate the center value before setting max values. Otherwise, the max value will not be correct.
3.3.5 Setting complete
After the completion of keyboard function setting, user needs to reboot the keyboard.
Keyboard function setting
network 设备 测试 exit
Setting complete, please reboot
Joystick blind area setting
Blind area range(20-60) Blind area 25 set exit
figure 3-23 keyboard reboot
13
4. Direct Control
In order to control RS-485 PTZuser needs to add direct control device in keyboard setting menu—device attributes, and set the correct communication protocol and baud rate.
4.1 Direct control Log-in
System control keyboard
device01 direct control
figure 5-1 keyboard log-in device menu
After power on, it displays log-in menu. Input device ID, press 【ENTER】to enter the following menu:
System control keyboard
Device 01 direct control
User 01 password
figure 5-2 keyboard log-in to direct control
Input keyboard ID, press【ENTER】,input correct password and press enter to 输 enter
direct control menu.
notedefault keyboard password: 000000.
4.2 Direct control menu
Number input
Direct control device 1 user 1
Cam 1 TPELCOP/9600 12345 scan track tour menu close
Description for current device Current cam No. protocol and baud rate Info tips Soft keys
figure 5-3 direct control menu
4.3 switch camera
Keyboard supports three ways of switching.camera address range 1-256):
1、 Input camera ID,press【CAM】 2、 Input camera ID,press【ENTER】
14
3、 pressPREV/NEXTto switch back and forth.
4.4 Direct Cam Control
Intelligent keyboard controller is able to execute the main functions of speed dome/
PTZ receiver.
1、 PTZ control: move joystick up and down, left and right, to control the
movements of pan/tilt. Speed is divided into 063 stepsLCD screen will display the value of movements. Use the lens keys to control zoom, focus and zoom.
2、 Preset operation: select camera ID, press any number, and press【PRESET
to call the preset position, preset number range 1255. press any number and pressSHIFT】+【PRESETto edit the preset position.
Aux switch: open/close the aux switch of the PTZ receiver, each receiver
supports 8 aux switch, needs special protocol.
Stoppress any number, pressSHIFT】+<shut>.
3、 Auto scan operation: press any number, press <scan> to call it. Total 8 auto
scannumber 1-8). Press <scan> to enter auto scan settings.
figure 5-4 Auto scan setting
Modify auto scan NO. press number, and press【ENTER】 Set left limitmove speed dome to the position, press <left limit> Set right limitmove speed dome to the position, press <right limit> Set scan speed press number, press <speed>range 1-30.
4、 Auto Scan OperationPress number buttons first ,and then<Scan> button to
call. 8 pcs of auto scanSeries number 1-8 are supported, and press <Scan> button to enter the auto scan setup menu.
Fig 5-4 Auto Scan Setup Change auto scan series number Press number button firstand then ENTER】。
Set auto scan left boundaryMove the joy stick to control speed dome to the
positionand press <left boundary> button
Set auto scan right boundaryMove the joy stick to control speed dome to the
Auto scan setting
scan 1
left limit right limit speed exit
Auto scan setting
scan 1
left limit right limit speed exit
15
positionand press <right boundary> button Set auto scan speed Press number button firstand then<Speed> button
Value 1-30)。
5、 Auto cruising operation:press number first,and then <Cruising> button to call.
8 cruising (Series Number 1-8 are supportedPress <Crusing> button to enter auto cruising setup menu
Fig 5-5 Auto Cruising Setup Change auto Cruising number Press number button and then【ENTER】 button Set cruising point interval: Press number button,and then <Interval> button Value 1-60)。 Add cruising pointPress <Add> button to enter the cruising point add menu
Fig 5-6 Add Cruising point
In the cruising point menuinput preset point number for each cruising point by sequence(Number 1-255)。Press【NEXT】/【ENTER】 button to move the arrow focus to next cruising pointand press【PREV】 to move the arrow to the previous cruising point. Press <Setup> button after setting all the cruising pointsand the sequence information will be save in the speed dome camera.
6、 Pattern Tour Operation: First press number key then press <tour> can be call.
It supports 8 tracks pattern tour. Push <tour> to the setting screen of pattern tour.
Pattern tour setting
tour 1
Begin Finish Exit
Add cruising point
. . . . . .
. . . . . .
set exit
Auto Cruising Setup cruise 1
add interval exit
5-7 Pattern tour setting
Change the number of pattern tour: First press number key then press ENTER
Setup pattern tour: press <start> enable pattern tour record then operate
joystick in order to let speed dome work with excepting tour that can be
16
memorized automatically . After finish setting, please release joystick and press < finish > close setting of pattern tour.
7、 Open OSD Menu Operation
Press <Menu> to open speed dome setup menu
8、 Re-log Operation:
Press 【SHIFT】+【CANCEL】to exit main interface of camera direct control.
Note: Auto scan, auto cruising, pattern tour, and open OSD menu need special protocol support.
17
5. Standalone DVR Control
In order to control standalone DVR, user needs to add DVR to keyboard through setting menu, and register a keyboard ID for controlling DVR. Connect power to the keyboard, press 【PGM】, and switch on the keyboard while holding 【PGM】, the keyboard will log into setting menu. In the setting menu, add the DVR ID into the keyboard and set a keyboard ID for controlling DVR. After the completion of above settings, please shut down the keyboard and power on again. After logging in, choose device 3 to enter DVR control mode. In the DVR control mode, please press 【SITE】, and input the DVR ID. After that, user will be able to control DVR through keyboard.for the functions of DVR, please refer to DVR user’s manual).
5.1 log onto DVR
System control keyboard
Device 01 DVR
Picture 6-1 log onto DVR
Power on the keyboard, input ID and password in log-in window, press【ENTER】to enter the following window
System control keyboard
Device 01 DVR
User 01 password
Picture 6-2 keyboard log-in DVR window
Input keyboard user ID and press【ENTER】, then input password and press【ENTER】
to enter DVR control window.
NoteDefault in-factory password for keyboard is 000000.
5.2 DVR Control Window
DVR keyboard 1 device 1 user 1
NO. 1 MODE DVR KEY1 F1 F2 play record shut
Description for current device, device NO. DVR camera NO. Current control mode Key tips Soft key
Picture 6-3 DVR control mode window
18
DVR keyboard 1 device 1 user 1
NO. 1 MODE DVRPTZ KEY1 F1 F2 auto preset shut
Description for current device, device NO.
Soft key
Key tips
DVR camera NO. Current control mode
Picture 6-4 Pan/Tilt control mode window
5.2.1 DVR Control After keyboard loging into DVR, it enters DVR control mode (it displays MODE
DVR ), and is able to set and control DVR menu and functions. Under DVR control mode, press 【iris off】, it will switch to pan/tilt control mode. Input password(password for logging into keyboardand press【ENTER】to enter pan/tilt control modeit displays MODE DVRPTZ. Under pan/tilt control mode, keyboard is able to control PTZ movements. PressCANCEL】to go back to DVR control mode.
Function description for keys on keyboardFunction keys on keyboard that are related to DVR control are basically the same with those on DVR front panel, some keys are soft keys.
【0】~【9】: Number keys 【F1】: Lighting control key 【F2】: aux device control key 【F3】 DVR mode:<play>key; pan/tilt control mode:<auto>key 【F4】 DVR mode:<record>key; pan/tilt control mode:<preset>key 【F5】 shut down 【CANCEL】: cancel 【ENTER】: confirm 【PREV】: multi-screen key:1、switch to multi-screen in preview window;2、
switch from menu mode to preview window
【NEXT】: Undefined 【PRESET】: DVR mode:<record>key; pan/tilt control mode:<preset>key 【LOCK】: Lock/unlock 【SITE】: DVR device selection key, able to control multi DVRs 【MACRO】: Undefined 【ALARM】: Undefined 【ARM】: Undefined 【PGM】: Menu key 【SHIFT】: Combination key 【MON】: Undefined 【CAM】: Undefined 【zoom in】: DVR mode:system information key;pan/tilt control mode:Zoom in 【zoom out】: DVR mode:talk key;pan/tilt control mode:Zoom out 【focus in】: DVR mode:input method key;pan/tilt control mode:Focus in 【focus out】: DVR mode:multi-screen key;pan/tilt control mode:Focus out 【iris on】: DVR mode:edit key;pan/tilt control mode:Lens iris on 【iris off】: DVR mode:pan/tilt control key;pan/tilt control mode:Lens iris off
19
5.2.2 DVR Device Switching Under DVR control mode,press【SITE】 ,NO. box background turns black,then input
可以 DVR number ID that you want to switch to(range 116),press【ENTERto confirm.
F1 F2 play record shut
DVR keyboard 1 device 1 user 1
NO. 1 MODE DVR
Picture 6-5 DVR switching window
5.2.3 Exit DVR Control Mode Press【SHIFT】+【CANCEL】 to exit DVR control mode and return to log-in window.
20
*Revised
12.23.16
Loading...